{"title":"Biohoods\/Clean Benches","description":"","products":[{"product_id":"baker-edgegard-eg-6320-6-1615-cl-bench","title":"Baker Edgegard EG6320 clean bench","description":"\u003ch2\u003e\u003cstrong\u003eBaker Edgegard EG6320 laminar flow clean bench\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBaker Edgegard clean benches are always in demand. The Baker Edgegard EG6320 assures product protection and is used in pharmaceutical production, research laboratories, manufacturing facilities, aerospace, bioscience, food processing, hospitals, and other research and production environments.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBaker Edgegard EG6320 laminar flow clean bench features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass 100, ISO Class 5 air cleanliness standard\u003c\/li\u003e\n\u003cli\u003e6’ wide (74” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli\u003eLaminar flow clean bench\u003c\/li\u003e\n\u003cli\u003eIncludes HEPA filter\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eClean benches assure product protection by ensuring that work done on the bench is exposed only to HEPA filtered air. The Baker EG6320s motor draws air through the lower front panel and sidewall section slots.\u003c\/p\u003e\n\u003cp\u003eThe pre-filter traps dust and large particles, after which the air travels through a HEPA filter at an average velocity of 100 fpm before being directed horizontally across the work surface. We provide filters for all our clean benches, including this Baker EG6320.\u003c\/p\u003e\n\u003cp\u003eThe Baker Edgegard EG6320 is very similar to the EG6252 model, with one significant difference: more vertical working room. The Baker EG6320 model offers an additional 6” of clearance in the working area.\u003c\/p\u003e\n\u003ch3\u003e\n\u003ca href=\"https:\/\/youtu.be\/5oI_MkR75bI\" style=\"font-style: italic; font-weight: bold;\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e to see the Baker Edgegard EG6320 on the American Instrument Exchange YouTube channel.\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/5oI_MkR75bI\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eTesting\u003c\/h3\u003e\n\u003cp\u003eThis Baker Edgegard EG6320 clean bench is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. ITheir services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003ePictures\u003c\/h3\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003eBaker Edgegard EG6320 clean bench specifications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior\u003c\/td\u003e\n\u003ctd\u003e74.25\"W x 42\"D x 70\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior work surface\u003c\/td\u003e\n\u003ctd\u003e70.5”W x 28.5\"D x 34.25\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox 850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 18.52 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/baker-edgegard-eg6320\/\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to read a review of the Baker Edgegard EG6320 clean bench on our blog!\u003c\/p\u003e","brand":"Baker","offers":[{"title":"Default Title","offer_id":28870110838832,"sku":"1615 CL BENCH","price":3950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/Contrast2_847b89a6-3040-4790-9169-351a585bf4e9.jpg?v=1695407851"},{"product_id":"baker-sg-603tx-sterilgard-iii-0887-bio-cab","title":"Baker Sg-603TX Sterilgard III biosafety cabinet","description":"\u003ch2\u003e6' Baker SterilGARD III Advance SG-603TX B2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp\u003eThe 6' Baker SterilGARD III Advance SG-603TX B2 is a Class II Type B2 total exhaust biosafety cabinet designed for applications where chemical effluent is present, and clean air is essential. Widely used in toxicology laboratories, this cabinet ensures 100% air exhaust by pulling contaminated air through a dedicated exhaust duct and into the facility’s exhaust system. Unlike standard biosafety cabinets, it functions similarly to a chemical fume hood, preventing air recirculation.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type B2\u003c\/li\u003e\n\u003cli\u003e6’ wide (78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli\u003e100% total exhaust biological safety cabinet\u003c\/li\u003e\n\u003cli\u003eIncludes new supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.youtube.com\/watch?v=EKmHAyUHo_Y\u0026amp;feature=youtu.be\" target=\"_blank\" rel=\"noopener\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to see the Baker SterilGARD SG-603TX on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/EKmHAyUHo_Y\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eThis updated version of the classic Baker SterilGARD series features an adaptive ergonomic design and an efficient airflow management system, enhancing both safety and comfort. Because it does not recirculate air, the Baker SterilGARD III Advance SG-603TX is suitable for handling agents treated with volatile toxic chemicals, ensuring a safer laboratory environment.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Baker SG-403TX is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or immediately after delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eUnless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment. Our testing procedures for B2 biosafety cabinets are limited, as we cannot replicate the same conditions as being hard ducted to the outside.\u003c\/p\u003e\n\u003cp\u003e We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n\u003cp\u003eBaker SG-603TX - Additional Specifications\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"80%\" style=\"height: 142.375px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003eExterior WxHxD (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003e78” x 64” x 30”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003eInterior work surface WxHxD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003e70” x 19” x 22”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003eWeight (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003eApprox 715 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 35.5938px;\"\u003e\n\u003cp\u003e115V, 60Hz, 15 Amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp\u003ePlease call or email us today for pricing and additional information regarding the Baker SterilGARD III Advance 603TX total exhaust bio safety cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/baker-sterilchemgard-iii-advance-sg603tx-total-exhaust-bio-safety-cabinet\/\" target=\"_blank\" rel=\"noopener\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to read a review of this product on our blog!\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$7500.00","offer_id":28870123061296,"sku":"0887 BIO CAB","price":8900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0887_BIO_CAB.jpg?v=1560350970"},{"product_id":"baker-sg-403tx-sterilgard-iii-0887a-bio-cab","title":"Baker SG-403TX Sterilgard III biosafety cabinet","description":"\u003ch2\u003e4'\u003cstrong\u003e \u003c\/strong\u003eBaker SterilGARD III Advance SG-403TX B2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp\u003eThe 4' Baker SterilGARD III Advance SG-403TX B2 is a Class II Type B2 total exhaust biosafety cabinet designed for applications where chemical effluent is present, and clean air is essential. Widely used in toxicology laboratories, this cabinet ensures 100% air exhaust by pulling contaminated air through a dedicated exhaust duct and into the facility’s exhaust system. Unlike standard biosafety cabinets, it functions similarly to a chemical fume hood, preventing air recirculation.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type B2\u003c\/li\u003e\n\u003cli\u003e4’ wide (54” exterior, 46” work surface)\u003c\/li\u003e\n\u003cli\u003e100% total exhaust biological safety cabinet\u003c\/li\u003e\n\u003cli\u003eIncludes new supply and exhaust HEPA filters (installed)\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eThis updated version of the classic Baker SterilGARD series features an adaptive ergonomic design and an efficient airflow management system, enhancing both safety and comfort. Because it does not recirculate air, the Baker SterilGARD III Advance SG-403TX is suitable for handling agents treated with volatile toxic chemicals, ensuring a safer laboratory environment.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Baker SG-403TX is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eUnless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment. Our testing procedures for B2 biosafety cabinets are limited, as we cannot replicate the same conditions as being hard ducted to the outside.\u003c\/p\u003e\n\u003cp\u003e We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n\u003ch2\u003eBaker 403TX - Additional Specifications\u003c\/h2\u003e\n\u003ctable width=\"80%\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eExterior WxHxD (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e54” x 64.5” x 30.5”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterior work surface WxHxD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e46” x 27.25” x 23.5”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApprox 800 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e115V, 60Hz, 9.0 Amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp\u003ePlease call or email us today for pricing and additional information regarding the Baker SterilGARD III Advance 403TX total exhaust bio safety cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca style=\"color: #3875b5;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/0887A-BIO-CAB.pdf?1738\" rel=\"noopener\" target=\"_blank\"\u003eView Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$7900.00","offer_id":28870132203568,"sku":"0887A BIO CAB","price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0887A_BIO_CAB.jpg?v=1560351154"},{"product_id":"thermo-1300-series-a2-6-0870x-bio-cab","title":"Thermo Scientific 1387 biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1387 6' A2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1387 biosafety cabinets incorporate advanced brushless DC motor technology, significantly improving energy efficiency, safety, and reliability. These DC motors not only reduce energy costs but also enhance overall system dependability while lowering air conditioning expenses. Additionally, they optimize environmental protection, making them a sustainable choice for your laboratory.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTo further increase energy efficiency, the cabinets include a night-set-back mode that maintains a clean workspace while conserving energy. When the front sash is closed, the intelligent speed control system automatically decreases the blower speed to 30%.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis feature extends the life of the HEPA filter and ensures a sterile work environment even during downtime. Compared to similar models, this reduced flow mode is 75% more energy efficient, offering unmatched performance and operational cost savings.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1387 6' Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide (74.8” exterior)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eSmartCoat chamber\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.youtube.com\/watch?v=AYZ4ycG5h8w\u0026amp;feature=youtu.be\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e to see the Thermo Scientific biosafety cabinet on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/AYZ4ycG5h8w\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1307 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 1300 Series A2 biosafety cabinets elevate safety and containment through an innovative airflow system. Independent supply and exhaust blowers automatically balance downflow and inflow\/exhaust velocities, ensuring consistently safe working conditions. This advanced design provides reliable protection for both users and samples.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor added comfort, the Thermo 1307 biosafety cabinet features a 10° front slope that minimizes operator fatigue during extended use. The reduced noise level creates a focused work environment free from distractions, while the spacious, unobstructed work surface enhances both productivity and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAdditionally, the flat, single-piece stainless steel work tray simplifies cleaning, saving time and effort. Thoughtfully designed armrests sit above the intake grill, enabling users to reach further into the cabinet while maintaining safe airflow, ensuring both comfort and protection.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1387 6' Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1387 – Additional Specifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e74.8”W x 31.75”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorkspace dimensions (height is back\/front)\u003c\/td\u003e\n\u003ctd\u003e70.5”W x 17.5”D x 30.7”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash opening\u003c\/td\u003e\n\u003ctd\u003e10”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e115 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1387 6' Biosafety Cabinet - Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1387 6' A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca rel=\"noopener noreferrer\" href=\"http:\/\/americaninstrument.info\/thermo-scientific-1300-series-bio-safety-cabinet\/\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003eto read a review of this product on our blog!\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific model 1387 biosafety cabinet frequently asked questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eWhat is the difference between all the 6’ wide Thermo Scientific 1300 series biosafety cabinets? For example, model 1387 vs model 1377?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAll of the Thermo 1300 series biosafety offer the same basic function and construction, namely two HEPA filters and a blower motor that provide protection for personnel, products, and the lab environment. Different model numbers signal small variations in specifications such as operating sash height, stainless steel interior walls vs. painted walls, interior fixtures or access ports, etc. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eI need multiple biosafety cabinets for my new lab. Are you able to supply several matching cabinets?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes, we frequently outfit new labs with multiple pieces of equipment. We encourage you to check out some of the \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/biotech-start-up-equipment-packages\"\u003elab equipment start up packages\u003c\/a\u003e from American Instrument Exchange. These include not only biosafety cabinets but incubators, centrifuges, microscopes, and more. We offer easy customization to match your specific budget, brand preferences, and research requirements.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eI purchased a Thermo 1387 from another vendor. Are you available to certify and\/or repair it? \u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAbsolutely. The team at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e can repair and certify biosafety cabinets for customers throughout New England, regardless of where the unit was purchased. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"$7000.00 \/ 08-28-2023","offer_id":28870175424560,"sku":"0870X BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0870X_BIO_CAB.jpg?v=1560351552"},{"product_id":"baker-eg8252-1620a-cl-bench","title":"Baker EdgeGARD EG8252","description":"\u003ch2 class=\"MsoNormal\"\u003eBaker EdgeGARD EG8252 16' Laminar Flow Clean Bench\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker Edgegard EG8252 16' Laminar Flow Clean Bench provides reliable product protection, making it essential for pharmaceutical production, research labs, and manufacturing facilities. It is also widely used in aerospace, bioscience, food processing, hospitals, and other research and production settings.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eClean benches like the Edgegard EG8252 ensure product safety by delivering HEPA-filtered air to the work area. This design guarantees that all work on the bench remains free from contaminants.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e16’ Baker EdgeGARD EG8252 – Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass 100, ISO Class 5 air cleanliness standard\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e16’ wide (197.75” exterior, 193.25” work surface)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eLaminar flow clean bench\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eBaker EdgeGARD EG8252 – Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker EG8252 operates efficiently by drawing air through the lower front panel and sidewall section slots. The motor directs the air through a pre-filter, which traps dust and large particles, ensuring cleaner airflow. Next, the air passes through a HEPA filter at an average velocity of 100 fpm before flowing horizontally across the work surface.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWe provide filters for all our clean benches, including the Baker EG8252, to maintain peak performance. This EG8252 model is comprised of two 8-foot clean benches that connect to create a seamless 16-foot workstation. To ensure proper airflow integrity, these units must be connected and operated together.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis 16’ Baker EdgeGARD EG8252 is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e16’ EdgeGARD EG8252 - Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"80%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eExterior (combined)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e197.75”W x 34\"D x 69.37\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior work surface (each)\u003c\/td\u003e\n\u003ctd\u003e193.25”W x 20\"D x 26.25\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (each)\u003c\/td\u003e\n\u003ctd\u003eApprox 850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements (each)\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 23.4 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eHowever, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 11.0pt; line-height: 107%; font-family: 'Aptos',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003eFor inquiries about the Baker Edgegard EG8252 16' Laminar Flow Clean Bench, call us at 978-521-2221 or fill out the form on this page.\u003c\/span\u003e\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$7500.00","offer_id":28870179061808,"sku":"1620A CL BENCH","price":4900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/PXL_20240531_154854150.jpg?v=1717172723"},{"product_id":"nuaire-labgard-nu440-600-biosafety-cabinet-0880g-bio-cab","title":"Nuaire NU440-600 biosafety hood","description":"\u003ch2\u003eNuaire LabGard NU440-600 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp\u003eThe Nuaire LabGard NU440-600 Biosafety Cabinet is designed with ergonomic features that enhance user comfort and efficiency. By providing more knee space, improved armrest support, and better visibility, this cabinet ensures a more comfortable working experience. Its thoughtful design reduces strain during extended use, making it ideal for laboratories that require precision and safety.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type A\/B3 or Type A2\u003c\/li\u003e\n\u003cli\u003e6’ wide model (78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli\u003eMicroprocessor controller\u003c\/li\u003e\n\u003cli\u003eIncludes new HEPA filters\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003eWant to view a video of this unit? \u003c\/strong\u003e\u003c\/em\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=RCUKL2Stghs\u0026amp;feature=youtu.be\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003eClick Here\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/youtu.be\/M84klUg312w\" style=\"box-sizing: border-box; color: #337ab7; text-decoration-line: none;\"\u003e \u003c\/a\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003eto see the Nuaire NU440-600 bio safety cabinet on the American Instrument Exchange YouTube channel. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/RCUKL2Stghs\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp data-start=\"393\" data-end=\"785\"\u003eBuilt for reliability, the NU440-600 features a unique sealed construction and a True Laminar Airflow HEPA filtration system. This advanced system maintains a clean and contaminant-free environment, ensuring the highest level of protection for both users and samples. The Electronic Airflow Control System offers precise, programmable settings, guaranteeing a safe and controlled workspace.\u003c\/p\u003e\n\u003cp data-start=\"787\" data-end=\"1058\" data-is-last-node=\"\"\u003eFor added convenience, the NU440-600 continuously monitors and displays airflow levels in real-time. The LED panel on the canopy control provides a clear and accurate reading of the average feet per minute, allowing users to verify optimal airflow conditions at a glance.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Nuaire NU440-600 is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eLabGard NU440-600 - Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 266px;\"\u003e\n\u003cp\u003eExterior WxHxD (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e78” x 63” x 33”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 266px;\"\u003e\n\u003cp\u003eInterior work surface WxHxD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e70” x 28.5” x 23.5”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 266px;\"\u003e\n\u003cp\u003eWeight (unpacked)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e~600 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 266px;\"\u003e\n\u003cp\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e115V, 60Hz, 15 Amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Nuaire LabGard NU440-600 Biosafety Cabinet, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$6500.00","offer_id":28870217367600,"sku":"0880G BIO CAB","price":6500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0880G_BIO_CAB.jpg?v=1560352053"},{"product_id":"baker-sg-403a-sterilgard-iii-0877c-bio-cab","title":"Baker SG-403A SterilGARD III","description":"\u003ch2\u003e4' Baker SterilGARD III Advance SG-403A Biosafety Cabinet\u003c\/h2\u003e\n\u003cp\u003eThe 4' Baker SterilGARD III Advance SG-403A Biosafety Cabinet is a Class II Type A2 cabinet designed to protect both users and the product inside from airborne contaminants and environmental hazards. This advanced model improves upon the classic Baker SG600 series by incorporating an adaptive ergonomic design and an efficient airflow management system, enhancing both safety and usability.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type A2\u003c\/li\u003e\n\u003cli\u003e4’ wide\u003c\/li\u003e\n\u003cli\u003eVertical laminar flow hood\u003c\/li\u003e\n\u003cli\u003eIncludes supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli\u003e90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/6i4cogHcgNg\" style=\"font-style: italic; font-weight: bold;\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e \u003cem\u003e\u003cstrong\u003eto see the Baker SG-403 Bio Safety Cabinet on the American Instrument Exchange YouTube channel. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/6i4cogHcgNg\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis cabinet features Baker Company’s momentum air curtain, which creates a strong protective air barrier. High-velocity air slots further enhance protection by preventing contamination of both the user and the product. The SterilGARD III Advance SG403A is ideal for research, clinical diagnostic work, tissue culture applications, and IV drug preparations. UV lights may be available upon request—contact us by phone or email for more details.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting and Certification \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eBaker SG-403 - Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"80%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eExterior\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e53”W x 30”D x 58”H(not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterior work surface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e46”W x 25”D x 27.5”H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e525lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e115V, 60Hz, 12.4 amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePictures\u003c\/h2\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp\u003ePlease call or email us today for pricing and additional information regarding the Baker SterilGARD III Advance SG403 biosafety cabinet.\u003cem\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/baker-sterilgard-iii-sg403-and-sg603-biosafety-cabinets\/\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003eto read a review of this product on our blog!\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$8900.00","offer_id":28870225723440,"sku":"0877C BIO CAB","price":8900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0877c-1.jpg?v=1643651123"},{"product_id":"thermo-scientific-1385-4-biosafety-cabinet-0870zz-bio-cab","title":"Thermo Scientific 1385 4' Biosafety Cabinet","description":"\u003ch1 class=\"MsoNormal\"\u003eThermo Scientific 1385 4' Class II, Type A2 Biosafety Cabinet\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1385 biosafety cabinet features advanced propriety airflow in a highly efficient design. This four-foot cabinet is extremely comfortable to use with its sloping design, bright workspace and low noise level.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1385 Biosafety Cabinet\u003cb\u003e \u003c\/b\u003e- Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eBright interior and quiet operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eEnergy efficient\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eReal-time airflow adjustments\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes stand and new filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThe 1385 4' Biosafety Cabinet\u003cb\u003e \u003c\/b\u003e– Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow adjustments in the Thermo Scientific 1385 are made in real time resulting in steady inflow and downflow velocities which includes adjustments resulting from changes in filter resistance. Brushless DC motor technology improves efficiency and reliability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eClosing the front sash reduces blower speed up to 30% resulting in up to 75% less energy usage. “Night Set Back” mode saves even more energy while maintaining a clean and safe work area. Two double outlets are installed to power equipment inside the work area. The sash has a working opening of 10 inches.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1385 4' Biological Safety Cabinet\u003cb\u003e \u003c\/b\u003e- Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Thermo Scientific 1385 4' Bio Safety Cabinet\u003cb\u003e \u003c\/b\u003eis used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOur testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1385 4' Biological Safety Cabinet\u003cb\u003e \u003c\/b\u003e- Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions\u003c\/td\u003e\n\u003ctd\u003e51”W x 31.5”D x 61.5”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownflow velocity\u003c\/td\u003e\n\u003ctd\u003e58 to 68 LFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120 V, 50\/60Hz, 8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1385 4' Biosafety Cabinet\u003cb\u003e \u003c\/b\u003e- Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment  stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eHowever, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1385 4' Bio Safety Cabinet, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cem\u003e\u003cstrong\u003eRead more about the \u003c\/strong\u003e\u003c\/em\u003eThermo Scientific 1385 4' Biosafety Cabinet\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"http:\/\/americaninstrument.info\/thermo-scientific-1300-series-bio-safety-cabinet\/\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003eto read a review of this product on our blog!\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"$7000.00 \/ 09-23-2024","offer_id":40721252745264,"sku":"0870ZZ BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0870ZZ_BIO_HOOD.jpg?v=1560352289"},{"product_id":"baker-sterilgard-iii-advance-sg-603a-0886e-bio-cab","title":"Baker Sterilgard III SG603A","description":"\u003ch2\u003e6' Baker SterilGARD III Advance SG-603A Biosafety Cabinet\u003c\/h2\u003e\n\u003cp\u003eThe 4' Baker SterilGARD III Advance SG-603A Biosafety Cabinet is a Class II Type A2 cabinet designed to protect both users and the product inside from airborne contaminants and environmental hazards. This advanced model improves upon the classic Baker SG600 series by incorporating an adaptive ergonomic design and an efficient airflow management system, enhancing both safety and usability.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type A2\u003c\/li\u003e\n\u003cli\u003e6’ wide (78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli\u003eIncludes supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli\u003eStand included\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWant to view a video of this unit? \u003c\/strong\u003e\u003c\/em\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/youtu.be\/V3qt5k4PrpE\" target=\"_blank\"\u003e\u003cem\u003e\u003cstrong\u003eClick Here\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e \u003cem\u003e\u003cstrong\u003eto see the Baker Sterilgard III SG603A on the American Instrument Exchange YouTube channel. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/V3qt5k4PrpE\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis cabinet features Baker Company’s momentum air curtain, which creates a strong protective air barrier. High-velocity air slots further enhance protection by preventing contamination of both the user and the product. The SterilGARD III Advance SG603A is ideal for research, clinical diagnostic work, tissue culture applications, and IV drug preparations. UV lights may be available upon request—contact us by phone or email for more details.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting and Certification \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eBaker SG603A - Additional Specifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eExterior WxHxD (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e78” x 64” x 30”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterior work surface WxHxD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e70” x 19” x 22”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApprox 715 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e115V, 60Hz, 15 Amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePictures\u003c\/h2\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp\u003ePlease call or email us today for pricing and additional information regarding the Baker SterilGARD III Advance SG603A biosafety cabinet.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca rel=\"noopener noreferrer\" href=\"http:\/\/americaninstrument.info\/baker-sterilgard-iii-sg403-and-sg603-biosafety-cabinets\/\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to read a review of this product on our blog!\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$8900.00 \/ 09-07-2023","offer_id":28870547013680,"sku":"0886E BIO CAB","price":8900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/0886E-1_35e1249b-7b8d-4ab0-9415-cabd0dc3928a.jpg?v=1693929132"},{"product_id":"nuaire-labgard-es-nu629-500-0880p-bio-cab","title":"Nuaire NU-629-500 biosafety","description":"\u003ch2 class=\"MsoNormal\"\u003e5’ Nuaire LabGard ES NU629-500 A2 Biological Safety Cabinet with Hydraulic Stand\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 5’ Nuaire LabGard ES NU629-500 is tailor-made for work in a vivarium by integrating an NSF-listed 12” (305mm) work access opening for cage access, castors and pull bars for mobility, and height adjustability for user ergonomics. This design also rises to the unique challenges of controlling airflow in a particulate-heavy environment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn vivariums, a standard biosafety cabinet's HEPA filters can saturate quickly due to hair and dander accumulation. However, adapting the cabinet with a pre-filter efficiently addresses this issue. By capturing larger particles, the pre-filter allows HEPA filters to handle finer particulate, extending their lifespan. Conveniently located on the back wall, the pre-filter is easy to remove and maintain.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU629-500 – Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes hydraulic stand\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=DRXxaPD2NmI\u0026amp;feature=youtu.be\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=YpO8UUT0BJc\u0026amp;feature=youtu.be\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to see the Nuaire NU-629-500 bio safety cabinet on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/qQPXmQ9Mnic\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU629-500 – Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIts ultra-efficient DC ECM motor ensures quiet operation, reduces energy consumption, and compensates for filter loading, extending HEPA filter life. The stainless-steel work zone is easy to clean and highly durable.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Aeromax control system enhances user confidence by displaying airflow conditions with multicolored lights. Audible and visual alarms alert users to deviations, ensuring optimal performance and safety. Adjustable height settings and an ergonomic design make the NU629-500 a dependable, user-friendly choice for demanding lab environments.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Nuaire NU629-500 is fully reconditioned and ready for use. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or immediately after delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the 5’ Nuaire LabGard ES NU629-500 A2 Biological Safety Cabinet with Hydraulic Stand, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$7200.00","offer_id":28870662389808,"sku":"0880P BIO CAB","price":7200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0880P_BIO_CAB.jpg?v=1560354450"},{"product_id":"nuaire-nu-425-400-a2-biosafety-cabinet-0875l-bio-cab","title":"Nuaire LabGard NU-425-400 A2 Biosafety Cabinet","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eNuaire LabGard NU-425-400 biological safety cabinet\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Nuaire LabGard NU-425-400 biosafety cabinet protects personnel, products, and the environment in tissue culture labs and other biological research or chemical containment areas.\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\n\u003cspan\u003eNuaire LabGard NU-425-400 \u003c\/span\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e4’ wide model\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eClass II, Type A2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eIncludes stand and new HEPA filters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eEnergy saving efficient motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eUV light may be available, please call or email us for details.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e90-day warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eNuaire LabGard NU-425-400 Features\u003c\/h2\u003e\n\u003cp\u003eThe Nuaire LabGard NU-425-400 operates as a Class II Type A2 biosafety cabinet. Specifically, it manages airflow by exhausting 30% of the air while recirculating 70% at a 100 FPM intake. Therefore, you can either recirculate the air into the room or exhaust it outdoors through a separately sold canopy exhaust connection; please call or email us for availability.\u003c\/p\u003e\n\u003cp\u003eIn addition, this model comes equipped with fluorescent lighting, a Magnehelic gauge, internal electrical outlets, and vacuum and gas valves. Notably, all controls are conveniently mounted in an integrated control module at eye level, while the large work opening allows easy access to the work zone, all while maintaining effective particulate control.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eNuaire LabGard NU-425-400 biological safety cabinet features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eMoreover, the Nuaire NU-425-400 offers enhanced visibility and reach with Class II Type A2 bio-hazard containment. It achieves this through a 100 LFPM air barrier, along with uni-directional laminar airflow that minimizes air turbulence and cross-contamination.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the HEPEX plenum inflates to deliver quiet, uniform air without transferring vibration. Importantly, the design incorporates positive pressure chambers and ducts surrounded by negative pressure, effectively eliminating potential leaks.\u003c\/p\u003e\n\u003cp\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=X44kv3aKDKY\u0026amp;feature=youtu.be\" target=\"_blank\"\u003eClick here\u003c\/a\u003e to see the Nuaire NU425-400 on the American Instrument Exchange YouTube channel. Video incorrectly states the model as the 5' NU425-500.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/X44kv3aKDKY\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eTesting and Certification\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eNuaire LabGard NU-425-400 Photos\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, Cantarell, 'Open Sans', 'Helvetica Neue', sans-serif;\"\u003ephotos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, Cantarell, 'Open Sans', 'Helvetica Neue', sans-serif;\"\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cspan lang=\"FR\" style=\"mso-ansi-language: FR;\"\u003eNuaire NU425-400 biosafety cabinet FAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eQ: Why do you install new HEPA filters in Nuaire NU-425-400 biosafety cabinets?\u003c\/i\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA: \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eNew filters for the Nuaire NU-425-400 plus the cost of installation can cost anywhere from $2,000 to $3,500 or more. We install new HEPA filters in every biosafety cabinet and clean bench prior to shipment. If you’re purchasing a used biosafety cabinet without filters, there’s no way to know for sure that it works properly. If you’re buying a used biosafety cabinet with old filters, you may not be able to determine the age of the filters or safe operating time remaining, plus there are concerns of contamination. Installing new filters is the best way for us to guarantee that each biosafety cabinet works to specification and is fully decontaminated.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eQ: Is the Nuaire NU-425-400 biosafety cabinet a reliable option for my lab?\u003c\/i\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Nuaire has been a trusted name in the industry for almost 50 years and their BSCs are durable, safe, and generally have long lifespans.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eQ:\u003c\/i\u003e \u003ci\u003eDo you certify these biosafety cabinets?\u003c\/i\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of an NSF-accredited certification in order to ensure that the unit will pass certification once it is at your site. However, every biosafety cabinet should be certified \u003ci\u003eafter\u003c\/i\u003e delivery to ensure that the unit is working properly to protect personnel and the lab environment. Please consult with a local certification company, such \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, for more information.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eQ: Is this unit still supported by the manufacturer?\u003c\/i\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Depending on the date of manufacture the Nuaire NU-425-400 may or may not still be supported. We are often able to source non-OEM parts to use in repairing\/refurbishing biosafety cabinets.\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$7200.00 \/ 09-19-2024","offer_id":28870838059056,"sku":"0875L BIO CAB","price":7100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/Nuaire_NU-425-400_A2_Biosafety_Cabinet.jpg?v=1723052936"},{"product_id":"baker-sterilgard-e3-sg604-0877k-bio-cab","title":"Baker SterilGARD e3 SG604 Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG604 Biosafety Cabinet\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD e3 SG604 is the most energy efficient biosafety cabinet available today. The newly redesigned airflow management system saves energy and improves both user comfort and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SG604 achieves maximum user protection through six technologies working in concert. Momentum air curtain, high-velocity return air slots, aerodynamically designed airfoil, optimized downflow, and unique air bypass armrest.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe energy saving features provide up to 60% increased energy efficiency when compared to similar biosafety cabinets and extend HEPA filter lifespan by up to 30%.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG604 Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0in;\"\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide (78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eVertical laminar flow hood\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=IUaVelx0zvg\u0026amp;feature=youtu.be\" target=\"_blank\"\u003e\u003cb\u003e\u003ci\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=IUaVelx0zvg\u0026amp;feature=youtu.be\" target=\"_blank\"\u003e\u003cem\u003e\u003cstrong\u003eClick Here\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e to see the Baker SG604 on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/IUaVelx0zvg\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG604 Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD e3 SG604 features the new trademarked ReadySAFE mode. A unique padded armrest allows the cabinet to maintain A2 conditions with the viewscreen in the close position. When the sash is lifted, the cabinet is instantly safe upon resuming standard operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe versatile ReadySAFE mode is designed to be used during breaks (even extended breaks such as overnight) to maintain safe conditions and save energy.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe audible and visual alarms alert the operator of some unsafe conditions including power\/processor fault alarm, viewscreen alarm, and double viewscreen position sensor fault alarm.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach SG604 cabinet has one cable port located in the right sidewall. This provides a safe means of introducing power cables, tubing or other similar items into the work area. It is designed with flexible neoprene seals allowing multiple cables and\/or tubing totaling up to 1 inch in diameter.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe operator controls and indicators are arranged in a single, easily cleaned membrane switch assembly on the front of the cabinet. There are pushbuttons for blower, fluorescent light, outlets, optional ultraviolet light and alarm mute.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe motor and blower are built as a single assembly and balanced to minimize vibration. The motor control automatically compensates for increased pressure drop across the filters without significantly reducing the total air flow rate. The air flow capacity of the cabinet is measured by the ability to provide a nearly constant volume of air as the filter resistance to airflow increases.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SG604 Testing\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG604 – Additional Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" border=\"1\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions (not including stand)\u003c\/td\u003e\n\u003ctd\u003e77.75”W x 31”D x 61.75”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior work surface dimensions\u003c\/td\u003e\n\u003ctd\u003e70”W x 24.5”D x 27.5”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (not including stand)\u003c\/td\u003e\n\u003ctd\u003eApprox 775 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements (call or email to confirm)\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 20 amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SG604 Pictures\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003ci\u003e\u003ca rel=\"noopener\" href=\"https:\/\/americaninstrument.info\/products-we-like-review-of-the-baker-sg604-biosafety-cabinet\/\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/i\u003e\u003c\/b\u003e to read a review of this product on our blog!\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/0877K-BIO-CAB.pdf?1743\" target=\"_blank\"\u003e\u003cb\u003e\u003ci\u003eView Manual\u003c\/i\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD e3 SG604 Biosafety Cabinet FAQs\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: What are some of the features that make the Baker SterilGard SG604 a good investment? \u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Because of the improvements in efficiency annual operating costs for the SG604 can be up to 70% lower than compared to the Baker SG603 models. A lot of this reduction can be attributed to the new StediFLOW variable frequency drive motor, which can accommodate increases in pressure drops of up to 300% across the filter with almost no reduction in total air delivery.  \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOne of our favorite features is the fold up front panel that allows for frontloading filters. For most biosafety cabinets, including older Baker units, removing the front panel is a time and labor-intensive activity. With the SG604, however, the front panel is hinged and swings up, similar to the hood of a car, allowing for quicker and easier HEPA filter replacement.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhile this sounds like a small improvement, but if you work with biosafety cabinets as frequently as we do you will quickly begin to appreciate how great this design is.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: Are the Baker Sterilgard SG604 units as durable as the older SG600 models?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Time will tell, although all indications are that these units will have some serious longevity. As of this writing we still see some Baker SG600 models in the field – every now and then our certifiers will come across a unit that is older than they are.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWill the Sterilgard 604s last this long? They are certainly quality built, as are all Baker products, with quality materials and a good design. We’re looking forward to working with these units for many years to come.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: Why do you install new HEPA filters in the Baker SG604 before shipping to customers? \u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: New filters for a Baker SterilGard SG604, plus the cost of installation, can total anywhere from $2,000 to $3,500 or more, depending on your location and what your certifier charges for installation. We install new HEPA filters in every biosafety cabinet and clean bench prior to shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you’re purchasing a used biosafety cabinet without filters, there’s no way to know for sure that it works properly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you’re buying a used biosafety cabinet with old filters, you may not be able to determine the age of the filters or safe operating time remaining, plus there are concerns of contamination.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstalling new filters is the best way for us to guarantee that each biosafety cabinet works to specification and is fully decontaminated.\u003c\/p\u003e","brand":"Baker","offers":[{"title":"Default Title","offer_id":40821376155696,"sku":"0877K BIO CAB","price":8100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/Baker_SterilGARD_e3_SG604_biosafety_cabinet.jpg?v=1726764016"},{"product_id":"nuaire-labgard-nu-425-600-0880k-bio-cab","title":"Nuaire NU425-600","description":"\u003ch2 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-600 6’ Biological Safety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-425-600 6’ biosafety cabinet protects personnel, products, and the environment in tissue culture labs and other biological research or chemical containment areas.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU-425-600 Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide model (approx 80” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA Filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-425-600 operates as a Class II Type A2 biosafety cabinet. Specifically, it manages airflow by exhausting 30% of the air while recirculating 70% at a 100 FPM intake. However, you can either recirculate the air into the room or exhaust it outdoors through a separately sold canopy exhaust connection; please call or email us for availability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn addition, this model comes equipped with fluorescent lighting, a Magnehelic gauge, internal electrical outlets, and a gas valve. \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=0BOfNtitYaQ\u0026amp;feature=youtu.be\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003eClick Here\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/youtu.be\/M84klUg312w\" style=\"box-sizing: border-box; color: #337ab7; text-decoration-line: none;\"\u003e \u003c\/a\u003eto see the Nuaire NU425-600 on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/0BOfNtitYaQ\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting and Certification\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Nuaire NU-425-600 is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment. We often stock multiple units of each model. We may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Nuaire LabGard NU-425-600 6’ Biological Safety Cabinet, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire NU425-600 biosafety cabinet FAQs\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eQ: Why do you install new HEPA filters in Nuaire NU-425-600 biosafety cabinets?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eNew filters for the Nuaire NU-425-600 plus the cost of installation can cost anywhere from $2,000 to $3,500 or more. We install new HEPA filters in every biosafety cabinet and clean bench prior to shipment. If you’re purchasing a used biosafety cabinet without filters, there’s no way to know for sure that it works properly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you’re buying a used biosafety cabinet with old filters, you may not be able to determine the age of the filters or safe operating time remaining, plus there are concerns of contamination. Installing new filters is the best way for us to guarantee that each biosafety cabinet works to specification and is fully decontaminated.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eQ: Is the Nuaire NU-425-600 biosafety cabinet a reliable option for my lab?\u003c\/i\u003e \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Nuaire has been a trusted name in the industry for almost 50 years and their BSCs are durable, safe, and generally have long lifespans. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eQ:\u003c\/i\u003e \u003ci\u003eDo you certify these biosafety cabinets?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of an NSF-accredited certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eHowever, every biosafety cabinet should be certified \u003ci\u003eafter\u003c\/i\u003e delivery to ensure that the unit is working properly to protect personnel and the lab environment. Please consult with a local certification company, such \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, for more information. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: Is this unit still supported by the manufacturer?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Depending on the date of manufacture the Nuaire NU-425-600 may or may not still be supported. We are often able to source non-OEM parts to use in repairing\/refurbishing biosafety cabinets. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$6900.00","offer_id":28870848086064,"sku":"0880K BIO CAB","price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/DSC_0406_36ba190c-00b4-4cf7-a660-fc46f674debb.jpg?v=1656006298"},{"product_id":"thermo-1305-biosafety-cabinet-0870vv-bio-cab","title":"Thermo Scientific 1305 biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1305 4' Class II, Type A2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1305 biosafety cabinet features advanced propriety airflow in a highly efficient design. This four-foot cabinet is extremely comfortable to use with its sloping design, bright workspace and low noise level.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1305 Biosafety Cabinet\u003cb\u003e \u003c\/b\u003e- Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eBright interior and quiet operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eEnergy efficient\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eReal-time airflow adjustments\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes stand and new filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThe 1305 4' Biosafety Cabinet\u003cb\u003e \u003c\/b\u003e– Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow adjustments in the Thermo Scientific 1305 are made in real time resulting in steady inflow and downflow velocities which includes adjustments resulting from changes in filter resistance. Brushless DC motor technology improves efficiency and reliability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eClosing the front sash reduces blower speed up to 30% resulting in up to 75% less energy usage. “Night Set Back” mode saves even more energy while maintaining a clean and safe work area. Two double outlets are installed to power equipment inside the work area. The sash has a working opening of 8 inches and maximum opening of 21 inches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=CntDr06oVE4\u0026amp;feature=youtu.be\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e to see the Thermo Scientific biosafety cabinet on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/CntDr06oVE4\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1305 4' Biological Safety Cabinet\u003cb\u003e \u003c\/b\u003e- Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Thermo Scientific 1305 4' Bio Safety Cabinet\u003cb\u003e \u003c\/b\u003eis used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOur testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1305 4' Biological Safety Cabinet\u003cb\u003e \u003c\/b\u003e- Additional Specifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions\u003c\/td\u003e\n\u003ctd\u003e51”W x 31.5”D x 61.5”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownflow velocity\u003c\/td\u003e\n\u003ctd\u003e58 to 68 LFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120 V, 50\/60Hz, 8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1305 4' Biosafety Cabinet\u003cb\u003e \u003c\/b\u003e- Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent the equipment currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eHowever, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1305 4' Bio Safety Cabinet, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cem\u003e\u003cstrong\u003eRead more about the \u003c\/strong\u003e\u003c\/em\u003eThermo Scientific 1305 4' Biosafety Cabinet\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/thermo-scientific-1300-series-bio-safety-cabinet\/\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003eto read a review of this product on our blog!\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific 1305 biosafety cabinet frequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eI’m trying to decide between a 6’ wide biosafety cabinet and a 4’ wide biosafety cabinet. Do you have any suggestions?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you have the space and budget, and all other factors being equal, we generally recommend going with the largest biosafety cabinet you can fit in your lab. This will provide your lab personnel with flexibility and space to work. Operating costs between a 6’ and 4’ model of the same brand\/vintage are minimal, as are replacement filters.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eWhy do you install new HEPA filters in the Thermo 1305 before shipping to customers?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eNew filters for a Thermo 1305, plus the cost of installation, can total anywhere from $2,000 to $3,500 or more, depending on your location and what your certifier charges for installation. We install new HEPA filters in every biosafety cabinet and clean bench prior to shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you purchase a used biosafety cabinet without filters, there’s no way to know for sure that it works properly because it can’t be fully tested\/certified.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you’re buying a used biosafety cabinet with old filters, you may not be able to determine the age of the filters or safe operating time remaining, plus there are concerns of contamination.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstalling new filters is the best way for us to guarantee that each biosafety cabinet works to specification and is fully decontaminated.\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"Default Title","offer_id":28870919290928,"sku":"0870VV BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/0870yy-1_36664c6a-4bb0-4504-87c0-64d396e00ad6.jpg?v=1766141839"},{"product_id":"thermo-1337-biosafety-cabinet-0870b-bio-cab","title":"Thermo Scientific 1337 6' Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1337 6' A2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1337 biosafety cabinets incorporate advanced brushless DC motor technology, significantly improving energy efficiency, safety, and reliability. These DC motors not only reduce energy costs but also enhance overall system dependability while lowering air conditioning expenses. Additionally, they optimize environmental protection, making them a sustainable choice for your laboratory.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTo further increase energy efficiency, the cabinets include a night-set-back mode that maintains a clean workspace while conserving energy. When the front sash is closed, the intelligent speed control system automatically decreases the blower speed to 30%.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis feature extends the life of the HEPA filter and ensures a sterile work environment even during downtime. Compared to similar models, this reduced flow mode is 75% more energy efficient, offering unmatched performance and operational cost savings.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1337 6' Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide (74.8” exterior)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStainless-steel chamber\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca title=\"Link to YouTube\" href=\"https:\/\/youtu.be\/qGFQrj4ige8\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003eto see the Thermo Scientific 6' 1300 Series A2 biosafety cabinet on our YouTube channel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/qGFQrj4ige8?si=LrpSyuIRgfKz3cEJ\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1337 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 1300 Series A2 biosafety cabinets elevate safety and containment through an innovative airflow system. Independent supply and exhaust blowers automatically balance downflow and inflow\/exhaust velocities, ensuring consistently safe working conditions. This advanced design provides reliable protection for both users and samples.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor added comfort, the Thermo 1337 biosafety cabinet features a 10° front slope that minimizes operator fatigue during extended use. The reduced noise level creates a focused work environment free from distractions, while the spacious, unobstructed work surface enhances both productivity and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAdditionally, the flat, single-piece stainless steel work tray simplifies cleaning, saving time and effort. Thoughtfully designed armrests sit above the intake grill, enabling users to reach further into the cabinet while maintaining safe airflow, ensuring both comfort and protection.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1337 6' Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1337 – Additional Specifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e74.8”W x 31.75”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork area dimensions\u003c\/td\u003e\n\u003ctd\u003e70.5”W x 17.5”D x 30.7\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash height\u003c\/td\u003e\n\u003ctd\u003e10”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1337 6' Biosafety Cabinet - Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1337 6' A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific model 1337 biosafety cabinet frequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eDo you sell parts for the Thermo 1337 biosafety cabinet, like sashes or HEPA filters?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eWe typically do not sell parts for these units but prefer to keep any spare parts to help refurbished additional models that come our way. We may be able to assist in sourcing parts for you, depending on the circumstances. Please contact us regarding with specifics for more information.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWe install new filters in every biosafety cabinet we sell, but we purchase these directly from the manufacturer or other non-OEM source. If you are looking for new HEPA filters we suggest contacting the manufacturer directly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRemember that biosafety cabinets also need to be decontaminated with chlorine dioxide to prevent contamination before opening the filter housing. If you’re in New England, our team at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\" target=\"_blank\" rel=\"noopener\"\u003eAIE Laboratory Services\u003c\/a\u003e is available for HEPA filter replacement and certifications.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eI purchased a Thermo 1337 from another vendor. Are you available to certify and\/or repair it? \u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAbsolutely. The team at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e can repair and certify biosafety cabinets for customers throughout New England, regardless of where the unit was purchased.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eI need multiple biosafety cabinets for my new lab. Are you able to supply several matching cabinets?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes, we frequently outfit new labs with multiple pieces of equipment. We encourage you to check out some of the \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/biotech-start-up-equipment-packages\"\u003elab equipment start up packages\u003c\/a\u003e from American Instrument Exchange. These include not only biosafety cabinets but incubators, centrifuges, microscopes, and more. We offer easy customization to match your specific budget, brand preferences, and research requirements.\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"Default Title","offer_id":41541074616368,"sku":"0870B BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0783copy_78a39b6b-632e-41f1-bf73-8bfaea449376.jpg?v=1718999012"},{"product_id":"nuaire-nu425-600-bio-cab-0880a-bio-cab","title":"Nuaire NU425-600 bio cab","description":"\u003c!-- x-tinymce\/html --\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU425-600Biological Safety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire NU425-600 6’ biosafety cabinet protects personnel, products, and the environment in tissue culture labs and other biological research or chemical containment areas.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU425-600 - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide model (approx 78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A\/B3\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA Filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e \u003ca data-cke-saved-href=\"https:\/\/www.youtube.com\/watch?v=zHRNjcHIMDM\u0026amp;feature=youtu.be\" href=\"https:\/\/www.youtube.com\/watch?v=zHRNjcHIMDM\u0026amp;feature=youtu.be\" rel=\"noopener\" target=\"_blank\"\u003eClick here\u003c\/a\u003e to see the Nuaire NU425-600 on the American Instrument Exchange YouTube channel. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/zHRNjcHIMDM\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNU425-600 Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire NU425-600 operates as a Class II Type A\/B3 biosafety cabinet. Specifically, it manages airflow by exhausting 30% of the air while recirculating 70% at a 100 FPM intake. However, you can either recirculate the air into the room or exhaust it outdoors through a separately sold canopy exhaust connection; please call or email us for availability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn addition, this model comes equipped with fluorescent lighting, a Magnehelic gauge, internal electrical outlets, and a gas valve.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting and Certification\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Nuaire NU425-600 is used and reconditioned. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU425-600 - Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions (not including stand)\u003c\/td\u003e\n\u003ctd\u003e78”W x 33”D x 60”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior work surface dimensions\u003c\/td\u003e\n\u003ctd\u003e70”W x 23”D x 28.5”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (unpacked)\u003c\/td\u003e\n\u003ctd\u003eapprox 630 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements (call to confirm)\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 14 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Nuaire NU425-600 6’ Biological Safety Cabinet, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$6500.00","offer_id":28979950846000,"sku":"0880A BIO CAB","price":6500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0880A-1.jpg?v=1643651823"},{"product_id":"baker-sterilgard-iii-advance-sg603a-he-0886f-bio-cab","title":"Baker Sterilgard SG603-HE","description":"\u003ch2\u003e6' Baker SterilGARD III Advance SG603A-HE Biosafety Cabinet\u003c\/h2\u003e\n\u003cp\u003eBaker SterilGARD III Advance SG603A-HE was the top of the line, premier biosafety cabinet of its time, brought to you by the company that invented the laminar flow biological safety cabinet. \u003c\/p\u003e\n\u003cp\u003eThe Baker SG603A-HE is a Class II Type A2 biosafety cabinet designed to protect people using the cabinet and the product inside the cabinet from airborne contaminants and the environment. This cabinet was an updated version of the classic Baker SG600 series and boasts an adaptive ergonomic design and efficient airflow management system.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type A2\u003c\/li\u003e\n\u003cli\u003e6’ wide (78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli\u003eIncludes new supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli\u003eHydraulic stand may be available\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=Jhlozfg88Cs\u0026amp;feature=youtu.be\" target=\"_blank\" rel=\"noopener\"\u003e\u003cem\u003e\u003cstrong\u003eClick Here\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=06rJ_NLPwRA\" target=\"_blank\" rel=\"noopener\"\u003e \u003c\/a\u003e to see the Baker SterilGARD III SG603A-HE on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Jhlozfg88Cs\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eThe ergonomic design helps prevent repetitive motion injury, reduces fatigue, and enhances productivity. The Baker SG603A-HE features a new airflow management system called StediFLOW. This technology includes a self-adjusting motor that uses less energy AND extends the life of HEPA filters for a double whammy of saving your lab money, all without sacrificing the safety of operators.\u003c\/p\u003e\n\u003cp\u003eThe press release from Baker announcing the SterilGARD III Advance SG603A-HE states, “With the optimum balance of performance and energy efficiency, our biological safety cabinets protect personnel, product and the environment, all while increasing lab productivity and user comfort. Each cabinet is backed by years of research [and] customer feedback.”\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eBaker SG603A-HE - Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"80%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eExterior dimensions (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e78”W x 31”D x 62”H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterior work surface dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e70”W x 25”D x 28”H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApprox 750lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e115V, 60Hz, 20 Amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Baker SG603A-HE, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/baker-sterilgard-iii-sg403-and-sg603-biosafety-cabinets\/\" target=\"_blank\" rel=\"noopener\"\u003eClick Here\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003eto read a review of this product on our blog!\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$11000.00 \/ 09-07-2023","offer_id":28979951271984,"sku":"0886F BIO CAB","price":11000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/DSC_1021_41e5d583-5496-48b1-a377-4814b20481a5.jpg?v=1650556971"},{"product_id":"baker-sterilgard-iii-sg404-bsc-0877j-bio-cab","title":"Baker SterilGARD e3 SG404 biosafety cabinet","description":"\u003ch2\u003e\u003cstrong\u003eBaker SterilGARD e3 SG404 biosafety cabinet\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Baker SterilGARD e3 SG404 biosafety cabinet is the most energy efficient biosafety cabinet available today. The newly redesigned airflow management system saves energy and improves both user comfort and safety. The energy saving features not only provide up to 60% increased energy efficiency when compared to similar biosafety cabinets. This also extend HEPA filter lifespan by up to 30%.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBaker SG404 biosafety cabinet specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"Different types of biosafety cabinets\" href=\"https:\/\/blog.americaninstrument.com\/a-guide-to-understanding-biosafety-cabinets\/\"\u003eClass II Type A2\u003c\/a\u003e, 4’ wide (53” exterior, 46” work surface)\u003c\/li\u003e\n\u003cli\u003eIncludes new supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli\u003eIncludes stand\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Warranty and ordering information\" href=\"https:\/\/www.americaninstrument.com\/pages\/ordering-information\"\u003e90-day warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBaker SG404 biosafety cabinet features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Baker SterilGARD e3 SG404 also features the new trademarked ReadySAFE mode. A unique padded armrest allows the cabinet to continue operation and maintain A2 conditions.\u003c\/p\u003e\n\u003cp\u003eWhen the sash is lifted, the cabinet is instantly safe upon resuming standard operation. The versatile ReadySAFE mode is designed to be used during breaks (even extended breaks such as overnight) to maintain safe conditions and save energy.\u003c\/p\u003e\n\u003cp\u003eThe Baker e3 SG404 cabinet has audible and visual alarms to alert the operator of some unsafe conditions including power\/processor fault alarm, viewscreen alarm, and double viewscreen position sensor fault alarm.\u003c\/p\u003e\n\u003cp\u003eEach SG404 cabinet has one cable port located in the right sidewall. This provides a safe means of introducing power cables, vacuum aspiration tubing or other similar items into the work area. It is designed with flexible neoprene seals allowing multiple cables and\/or tubing totaling up to 1 inch in diameter.\u003c\/p\u003e\n\u003cp\u003eThe operator controls and indicators are arranged in a single, easily cleaned membrane switch assembly on the front of the cabinet. There are pushbuttons for blower, fluorescent light, outlets, optional ultraviolet light and alarm mute.\u003c\/p\u003e\n\u003cp\u003eThe motor and blower are built as a single assembly and balanced to minimize vibration. The motor control automatically compensates for an increase in pressure drop across the filters without reducing the total air flow rate by more than 10%. The air flow capacity of the cabinet is measured by the ability to provide a nearly constant volume of air as the filter resistance to airflow increases.\u003c\/p\u003e\n\u003ch2\u003eBiosafety cabinet testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians \u003ca title=\"Biosafety cabinet testing\" href=\"https:\/\/aielaboratoryservices.com\/testingcertification\/\"\u003etest each biosafety cabinet \u003c\/a\u003eand clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our affiliate company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e. We can schedule your certification to align with delivery of the BSC. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBaker SterilGARD e3 SG404 Additional Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 337px;\"\u003e\n\u003cp\u003eExterior dimensions (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 246px;\"\u003e\n\u003cp\u003e53.75”W x 30.5”D x 61.75”H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 337px;\"\u003e\n\u003cp\u003eInterior work surface dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 246px;\"\u003e\n\u003cp\u003e46”W x 24.5”D x 27.5”H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 337px;\"\u003e\n\u003cp\u003eWeight (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 246px;\"\u003e\n\u003cp\u003eApprox 585 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 337px;\"\u003e\n\u003cp\u003eElectrical Requirements (call or email to confirm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 246px;\"\u003e\n\u003cp\u003e115V, 60Hz, 15 amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePlease call or email us today for pricing and additional information regarding the Baker SterilGARD e3 SG404 biosafety cabinet.\u003c\/p\u003e\n\u003ch3\u003ePictures\u003c\/h3\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have \u003ca title=\"Refurbished biosafety cabinets for sale\" href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003emultiple units\u003c\/a\u003e of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003ch3\u003eBaker SterilGARD SG404 frequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: What are some of the features that make the Baker SterilGard SG404 a good investment? \u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Because of the improvements in efficiency annual operating costs for the SG404 can be up to 70% lower than compared to the Baker SG403 models.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA lot of this reduction can be attributed to the new StediFLOW variable frequency drive motor, which can accommodate increases in pressure drops of up to 300% across the filter with almost no reduction in total air delivery.  One of our favorite features is the fold up front panel that allows for frontloading filters.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor most biosafety cabinets, including older Baker units, removing the front panel is a time and labor-intensive activity. With the SG404, however, the hinged front panel swings up, similar to the hood of a car, allowing for quicker and easier HEPA filter replacement.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis sounds like a small improvement, but if you work with biosafety cabinets as frequently as we do you will quickly begin to appreciate how great this design is.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: Are the Baker Sterilgard SG404 units as durable as the older SG400 models?\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: Time will tell, although all indications are that these units will have some serious longevity. As of this writing we still see some Baker SG400 models in the field – every now and then our certifiers will come across a unit that is older than they are.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWill the Sterilgard 404s last this long? They are certainly quality built, as are all Baker products, with quality materials and a good design. We’re looking forward to working with these units for many years to come.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eQ: Why do you install new HEPA filters in the Baker SG404 before shipping to customers? \u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA: New filters for a Baker SterilGard SG404, plus the cost of installation, can total anywhere from $2,000 to $3,500 or more, depending on your location and what your certifier charges for installation. We install new HEPA filters in every biosafety cabinet and clean bench prior to shipment. If you’re purchasing a used biosafety cabinet without filters, there’s no way to know for sure that it works properly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you’re buying a used biosafety cabinet with old filters, you may not be able to determine the age of the filters or safe operating time remaining, plus there are concerns of contamination. Installing new filters is the best way for us to guarantee that each biosafety cabinet works to specification and completely decontaminated.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Baker","offers":[{"title":"Default Title","offer_id":40833382940720,"sku":"0877J BIO CAB","price":6900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0877J-1.jpg?v=1697033258"},{"product_id":"thermo-scientific-1300-series-biosafety-cabinet-0870w-bio-cab","title":"Thermo Scientific 1377 Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1377 A2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1377 biosafety cabinets incorporate advanced brushless DC motor technology, significantly improving energy efficiency, safety, and reliability. These DC motors not only reduce energy costs but also enhance overall system dependability while lowering air conditioning expenses. Additionally, they optimize environmental protection, making them a sustainable choice for your laboratory.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTo further increase energy efficiency, the cabinets include a night-set-back mode that maintains a clean workspace while conserving energy. When the front sash is closed, the intelligent speed control system automatically decreases the blower speed to 30%.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis feature extends the life of the HEPA filter and ensures a sterile work environment even during downtime. Compared to similar models, this reduced flow mode is 75% more energy efficient, offering unmatched performance and operational cost savings.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1377 6' Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide (74.8” exterior)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStainless-steel chamber\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003e \u003ca href=\"https:\/\/www.youtube.com\/watch?v=BC-IVub6uIE\u0026amp;feature=youtu.be\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003ca style=\"box-sizing: border-box; color: #337ab7; text-decoration-line: none;\" href=\"https:\/\/youtu.be\/M84klUg312w\"\u003e \u003c\/a\u003e\u003cem style=\"box-sizing: border-box;\"\u003e\u003cstrong style=\"box-sizing: border-box;\"\u003eto see the Thermo 1377 bio safety cabinet on the American Instrument Exchange YouTube channel.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/BC-IVub6uIE\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1377 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 1300 Series A2 biosafety cabinets elevate safety and containment through an innovative airflow system. Independent supply and exhaust blowers automatically balance downflow and inflow\/exhaust velocities, ensuring consistently safe working conditions. This advanced design provides reliable protection for both users and samples.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor added comfort, the Thermo 1377 biosafety cabinet features a 10° front slope that minimizes operator fatigue during extended use. The reduced noise level creates a focused work environment free from distractions, while the spacious, unobstructed work surface enhances both productivity and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAdditionally, the flat, single-piece stainless steel work tray simplifies cleaning, saving time and effort. Thoughtfully designed armrests sit above the intake grill, enabling users to reach further into the cabinet while maintaining safe airflow, ensuring both comfort and protection.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1377 6' Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca rel=\"noopener\" href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1377 – Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e74.8”W x 31.75”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorkspace dimensions (height is back\/front)\u003c\/td\u003e\n\u003ctd\u003e70.5”W x 17.5”D x 30.7”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash opening\u003c\/td\u003e\n\u003ctd\u003e10”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e115 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eThermo 1377 6' Biosafety Cabinet - Pictures\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1377 6' A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific model 1377 biosafety cabinet frequently asked questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eCan I come and see the Themo 1377 in operation before I purchase it?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eCustomers are welcome to make an appointment to come to our shop and warehouse in Haverhill, MA, to see equipment in person prior to purchase. Given our workload and the \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/lab-equipment-repair-services\"\u003ebusy schedule our techs maintain\u003c\/a\u003e we may not be able to set up every piece of equipment for operation, but rest assured that we do \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/ordering-information\"\u003etest and warranty\u003c\/a\u003e all equipment. Please \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/contact-us\"\u003econtact\u003c\/a\u003e our sales team for more information. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eDo you sell filters for the Thermo 1300 series BSCs?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eWe install new filters in every biosafety cabinet we sell, but we purchase these directly from the manufacturer or other non-OEM source. If you are looking for new HEPA filters we suggest contacting the manufacturer directly. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRemember that biosafety cabinets also need to be decontaminated with chlorine dioxide to prevent contamination before opening the filter housing. If you’re in New England, our team at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\" target=\"_blank\" rel=\"noopener\"\u003eAIE Laboratory Services\u003c\/a\u003e is available for HEPA filter replacement and certifications.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eCan you install a Thermo 1385 biosafety cabinet in my lab? We can’t lift it onto the stand.\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eFor customers in New England our movers can bring biosafety cabinets into the lab and set the units in place on the stands, after which \u003ca href=\"https:\/\/aielaboratoryservices.com\/testingcertification\/\"\u003eour certifiers\u003c\/a\u003e are able to make sure the unit is fully functional and operating to specification. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you are outside of New England please contact our sales team – we may be able to offer a recommendation on a local moving company or other provider to assist you with installation of the BSC. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eDo you sell parts for the Thermo 1300 series biosafety cabinets?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eWe typically do not sell parts for these units but prefer to keep any spare parts to help refurbished additional models that come our way. We may be able to assist in sourcing parts for you, depending on the circumstances. Please contact us regarding with specifics for more information. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"Default Title","offer_id":40739750576176,"sku":"0870W BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0784_9d148843-d2b6-41be-a57b-9794c660b466.jpg?v=1704811424"},{"product_id":"thermo-scientific-1335-0870yy-bio-cab","title":"Thermo Scientific 1335 4' Biosafety Cabinet","description":"\u003ch2\u003eThermo Scientific 1335 biosafety cabinet\u003c\/h2\u003e\n\u003cp\u003eThe 4' Thermo Scientific 1335 biosafety cabinets feature advancements in brushless DC motor technology for dramatically improved energy efficiency, safety performance and reliability. These DC motors improvements result in reduced energy costs for your lab, increased reliability, reduced air conditioning costs, and optimized environmental protection.\u003c\/p\u003e\n\u003cp\u003eFurthermore the night-set-back mode saves energy while maintaining a clean work area. When the front sash is closed, the intelligent speed control automatically reduces blower speed to 30%. This extends HEPA filter life and ensuring a sterile working environment even when the cabinet is not in use. This reduced flow mode is 75% more energy efficient than similar features on other biological safety cabinets.\u003c\/p\u003e\n\u003ch2\u003eThermo Scientific 1335 biosafety cabinet features\u003c\/h2\u003e\n\u003cul style=\"box-sizing: border-box; margin-top: 0px; margin-bottom: 10px;\"\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e4’ wide (51.2” exterior)\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eStand included\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1300 Series A2 bio cabs employ a unique airflow system that raises safety and containment to a new level. Independent supply and exhaust blowers automate balancing of downflow and inflow\/exhaust velocities to ensure continuous safe working conditions. The Thermo 1335 bio safety cabinet also features a front slope of 10° for enhanced comfort and reduced operator fatigue.\u003c\/p\u003e\n\u003cp\u003eReduced noise level enhances the attention and allows user to focus on work without distraction. The large, unobstructed work surface increases productivity and safety. The flat, single-piece stainless steel work tray supports ease of cleaning. Comfortable Armrest Armrests sit just above the intake grill to enable farther reach inside the cabinet while maintaining safe airflows.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cem\u003e\u003cstrong\u003e \u003ca title=\"Link to YouTube\" href=\"https:\/\/youtu.be\/mmLapFH_5qo\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003e to see the Thermo 1300 Series 4' A2 biosafety cabinet on our YouTube channel\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/mmLapFH_5qo?si=x_D5dLyxFLyhN1bu\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eTesting\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003ePictures\u003c\/h3\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThermo Scientific 1335 4' biosafety cabinet - Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"80%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51.2”W x 31.5”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior dimensions\u003c\/td\u003e\n\u003ctd\u003e47.2”W x 30.7”D x 24.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight of sash\u003c\/td\u003e\n\u003ctd\u003e8\"-10\" (working), 21\" (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003eFor inquiries about the Thermo 1335, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThermo Scientific 1335 Biosafety Cabinet – Frequently Asked Questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eWhat type of biosafety cabinet is the Thermo Scientific 1335?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe Thermo Scientific 1335 is a Class II, Type A2 biosafety cabinet designed to protect personnel, the product, and the environment during microbiological work.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eClass II A2 cabinets use a combination of HEPA-filtered laminar airflow and inward air movement to prevent contamination and safely contain biological materials used in research and clinical laboratories. These cabinets are commonly used for:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eCell culture and tissue culture work\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eMicrobiology applications\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePharmaceutical research\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eClinical laboratory procedures\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHandling low- to moderate-risk biological agents\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eHow energy efficient is the Thermo Scientific 1335?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe 1335 biosafety cabinet uses energy-efficient DC motors, which can reduce operating costs by up to 75% compared with traditional AC motor cabinets.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eAdditional energy-saving features include:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eNight-setback mode, which lowers airflow when the sash is closed\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eReduced HVAC load in laboratory spaces\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eExtended HEPA filter life due to controlled airflow speeds \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThese design improvements help reduce total cost of ownership over the cabinet’s lifetime.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eWhat types of laboratories use the Thermo Scientific 1335?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis biosafety cabinet is commonly used in:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eBiomedical research laboratories\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003ePharmaceutical development labs\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eClinical diagnostic laboratories\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eAcademic research facilities\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eBiotechnology companies\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eIts Class II A2 containment design makes it suitable for handling biological agents up to Biosafety Level 2 and certain BSL-3 procedures with proper precautions.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"11-20-2024","offer_id":32680139063344,"sku":"0870YY BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0870yy-3.jpg?v=1611331461"},{"product_id":"thermo-1375-classii-typea2-0870z-bio-cab","title":"Thermo Scientific 1375 model biosafety cabinet","description":"\u003ch2\u003eThermo Scientific 1375 biosafety cabinet\u003c\/h2\u003e\n\u003cp\u003eThermo Scientific 1375 biosafety cabinets feature advancements in brushless DC motor technology for dramatically improved energy efficiency, safety performance and reliability. These DC motors improvements result in reduced energy costs for your lab, increased reliability, reduced air conditioning costs, and optimized environmental protection.\u003c\/p\u003e\n\u003cp\u003eFurthermore the night-set-back mode saves energy while maintaining a clean work area. When the front sash is closed, the intelligent speed control automatically reduces blower speed to 30%. This extends HEPA filter life and ensuring a sterile working environment even when the cabinet is not in use. This reduced flow mode is 75% more energy efficient than similar features on other biological safety cabinets.\u003c\/p\u003e\n\u003ch2\u003eThermo Scientific 1375 biosafety cabinet features\u003c\/h2\u003e\n\u003cul style=\"box-sizing: border-box; margin-top: 0px; margin-bottom: 10px;\" helvetica=\"\" font-size:=\"\"\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e4’ wide (51.2” exterior)\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eStand included\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1300 Series A2 bio cabs employ a unique airflow system that raises safety and containment to a new level. Independent supply and exhaust blowers automate balancing of downflow and inflow\/exhaust velocities to ensure continuous safe working conditions. The Thermo 1375 bio safety cabinet also features a front slope of 10° for enhanced comfort and reduced operator fatigue.\u003c\/p\u003e\n\u003cp\u003eReduced noise level enhances the attention and allows user to focus on work without distraction. The large, unobstructed work surface increases productivity and safety. The flat, single-piece stainless steel work tray supports ease of cleaning. Comfortable Armrest Armrests sit just above the intake grill to enable farther reach inside the cabinet while maintaining safe airflows.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cem\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/youtu.be\/mmLapFH_5qo\" title=\"Link to YouTube\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003e to see the Thermo 1300 Series 4' A2 biosafety cabinet on our YouTube channel\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/mmLapFH_5qo?si=x_D5dLyxFLyhN1bu\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eTesting\u003c\/h3\u003e\n\u003cp\u003eOur technicians test each bio safety cabinet to ensure that the controls and blower motor work properly. Unless otherwise specified all bio safety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment. Our testing procedure includes all the elements of a bio safety cabinet certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003ch3\u003ePictures\u003c\/h3\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThermo Scientific 1375' biosafety cabinet - Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable width=\"80%\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51.2”W x 31.5”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior dimensions\u003c\/td\u003e\n\u003ctd\u003e47.2”W x 30.7”D x 24.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight of sash\u003c\/td\u003e\n\u003ctd\u003e10\" (working), 21\" (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003eFor inquiries about the Thermo 1375, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThermo Scientific 1375 Biosafety Cabinet FAQs\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h2\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat is the Thermo Scientific 1375 biosafety cabinet used for?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe Thermo Scientific 1375 is a Class II Type A2 biosafety cabinet designed to provide personnel, product, and environmental protection in laboratory settings.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eIt is commonly used for:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l6 level1 lfo1; tab-stops: list .5in;\"\u003eCell culture and microbiology research \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l6 level1 lfo1; tab-stops: list .5in;\"\u003eClinical diagnostics and pharmaceutical workflows \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l6 level1 lfo1; tab-stops: list .5in;\"\u003eSterile compounding (non-volatile applications) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l6 level1 lfo1; tab-stops: list .5in;\"\u003eBiosafety Level 1–3 (BSL-1 to BSL-3) procedures \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eLike all Class II cabinets, it creates a HEPA-filtered sterile work zone while preventing contamination exposure. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eHow does airflow work in the Thermo 1375?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe cabinet uses a dual HEPA filtration system with laminar airflow:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l8 level1 lfo3; tab-stops: list .5in;\"\u003eRoom air enters through the front opening \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l8 level1 lfo3; tab-stops: list .5in;\"\u003eAir mixes with recirculated HEPA-filtered air \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l8 level1 lfo3; tab-stops: list .5in;\"\u003eClean air flows downward across the work surface \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l8 level1 lfo3; tab-stops: list .5in;\"\u003eContaminated air is captured and filtered again \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l8 level1 lfo3; tab-stops: list .5in;\"\u003eAir is either recirculated or safely exhausted \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis system ensures:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l7 level1 lfo4; tab-stops: list .5in;\"\u003eSterility of samples \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l7 level1 lfo4; tab-stops: list .5in;\"\u003eOperator protection \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l7 level1 lfo4; tab-stops: list .5in;\"\u003eEnvironmental containment\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat size is the Thermo Scientific 1375 cabinet?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe Thermo 1375 is a 4-foot biosafety cabinet, ideal for standard lab workflows.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eTypical dimensions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo2; tab-stops: list .5in;\"\u003eExterior: ~51.2\" W × 31.5\" D × 61.8\" H \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo2; tab-stops: list .5in;\"\u003eInterior workspace: ~47.2\" W × ~24.8–30.7\" D \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo2; tab-stops: list .5in;\"\u003eWorking sash opening: ~10\" (max ~21\") \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis size provides a compact footprint with ample working space, making it ideal for single users or smaller labs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eIs the Thermo 1375 energy efficient?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eYes. The 1300 Series is engineered for low energy consumption and reduced operating costs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eEfficiency benefits:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo5; tab-stops: list .5in;\"\u003eElectronically controlled motors that adjust airflow automatically \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo5; tab-stops: list .5in;\"\u003eReduced need for manual balancing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo5; tab-stops: list .5in;\"\u003eLower HVAC impact compared to ducted cabinets \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThese features make the 1375 a cost-effective long-term solution for labs running continuously.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eCan the Thermo 1375 be used with chemicals or hazardous drugs?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe Thermo 1375 is not recommended for volatile toxic chemicals.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eBecause it recirculates air:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo6; tab-stops: list .5in;\"\u003eChemical vapors may remain the cabinet \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo6; tab-stops: list .5in;\"\u003eIt is best suited for biological applications only \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eFor hazardous drugs or volatile chemicals, a \u003ca href=\"https:\/\/www.americaninstrument.com\/products\/thermo-1510-biosafety-cabinet-0870cc-bio-cab?_pos=1\u0026amp;_sid=53bbc7132\u0026amp;_ss=r\"\u003eClass II Type B2 cabinet\u003c\/a\u003e is recommended instead.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eIs a refurbished Thermo 1375 biosafety cabinet reliable?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eYes—when refurbished by a qualified vendor like American Instrument Exchange.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003eEach unit undergoes:\u003c\/a\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l9 level1 lfo7; tab-stops: list .5in;\"\u003eFull decontamination and cleaning \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l9 level1 lfo7; tab-stops: list .5in;\"\u003eHEPA filter integrity (PAO\/DOP) testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l9 level1 lfo7; tab-stops: list .5in;\"\u003eAirflow velocity and smoke pattern testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l9 level1 lfo7; tab-stops: list .5in;\"\u003eElectrical and alarm system verification \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l9 level1 lfo7; tab-stops: list .5in;\"\u003eComponent repair or replacement as needed \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThese processes ensure the cabinet meets NSF\/ANSI 49 performance standards for safety and containment.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat certifications are required before use?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eBefore operation, the cabinet must be certified on-site.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eCertification includes:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo8; tab-stops: list .5in;\"\u003eHEPA filter leak testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo8; tab-stops: list .5in;\"\u003eAirflow velocity verification \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo8; tab-stops: list .5in;\"\u003eContainment testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe manufacturer specifies that cabinets must be certified before first use and annually thereafter. For more information on certifications, please contact our technicians at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhy choose a refurbished Thermo 1375 instead of new?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eRefurbished units offer:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo9; tab-stops: list .5in;\"\u003eSignificant cost savings (often 40–70% less than new) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo9; tab-stops: list .5in;\"\u003eVerified performance after testing and certification \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo9; tab-stops: list .5in;\"\u003eSustainable reuse of lab equipment \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo9; tab-stops: list .5in;\"\u003eWarranty and service support \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eFor most labs, refurbished cabinets deliver like-new performance at a much lower cost.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhy buy from American Instrument Exchange?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eAmerican Instrument Exchange offers:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo10; tab-stops: list .5in;\"\u003eThorough refurbishment and \u003ca href=\"https:\/\/aielaboratoryservices.com\/testingcertification\/\"\u003eNSF-compliant testing\u003c\/a\u003e \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo10; tab-stops: list .5in;\"\u003eNew or verified HEPA filters \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo10; tab-stops: list .5in;\"\u003eCompetitive pricing and fast shipping \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo10; tab-stops: list .5in;\"\u003eDecades of experience in lab equipment \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eTheir process ensures you receive a certification-ready biosafety cabinet that performs reliably—without the cost of new equipment.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"Default Title","offer_id":40739765485616,"sku":"0870Z BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/0870yy-1.jpg?v=1717097232"},{"product_id":"thermo-1371-biosafety-cabinet-0870aa-bio-cab","title":"Thermo Scientific 1371 5' Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1371 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 5' Thermo Scientific 1371 biosafety cabinet features advancements in brushless DC motor technology for dramatically improved energy efficiency, safety performance and reliability. These DC motors improvements result in reduced energy costs for your lab, increased reliability, reduced air conditioning costs, and optimized protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFurthermore, the night-set-back mode saves energy while maintaining a clean work area. When the front sash is closed, the intelligent speed control automatically reduces blower speed to 30%. This extends HEPA filter life and ensuring a sterile working environment even when the cabinet is not in use. This reduced flow mode is 75% more energy efficient than similar features on other biological safety cabinets.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1371 biosafety cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e5’ wide (51.2” exterior)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/-iRdkvuQM5o\" title=\"Link to YouTube\"\u003e\u003cem\u003e\u003cstrong\u003eCLICK HERE\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/youtu.be\/-iRdkvuQM5o\" title=\"Link to YouTube\"\u003e \u003c\/a\u003eto see the Thermo Scientific 1371 5' A2 biosafety cabinet on our YouTube channel\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/-iRdkvuQM5o?si=idWF2RblgXLHNC5J\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eThermo 1371 5' Biosafety Cabinet - Features\u003c\/h2\u003e\n\u003cp\u003eThe 1300 Series A2 bio cabs employ a unique airflow system that raises safety and containment to a new level. Independent supply and exhaust blowers automate balancing of downflow and inflow\/exhaust velocities to ensure continuous safe working conditions.\u003c\/p\u003e\n\u003cp\u003eThe Thermo 1371 bio safety cabinet also features a front slope of 10° for enhanced comfort and reduced operator fatigue. Reduced noise level (65 dB) enhances the attention and allows user to focus on work without distraction while the large, unobstructed work surface increases productivity and safety.\u003c\/p\u003e\n\u003cp\u003eThe flat, single-piece stainless steel work tray supports ease of cleaning. Comfortable Armrest Armrests sit just above the intake grill to enable farther reach inside the cabinet while maintaining safe airflows.\u003c\/p\u003e\n\u003cp\u003eThe LCD display clearly displays real-time performance data, including inflow and downflow velocities and hours of operation. The control panel has a SmartFlow indicator that visually demonstrates power and capacity to maintain protection. Additionally, it has audible and visual alarms that indicate whether the sash is in the correct working position and when airflow is out of tolerance.\u003c\/p\u003e\n\u003cp\u003eIt also has an indicator for the Night Set-Back function that displays reduced speed operation when the sash is closed.\u003c\/p\u003e\n\u003ch2\u003eTesting and Certification\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eThermo 1371 – Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63”W x 31.75”D x 60”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork area dimensions\u003c\/td\u003e\n\u003ctd\u003e59”W x 17.5”D x 31.5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash height\u003c\/td\u003e\n\u003ctd\u003e10”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e573 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePictures\u003c\/h2\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have multiple units of each model in stock so we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp\u003eFor inquiries about the Thermo Scientific 1371, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThermo Scientific 1371 Biosafety Cabinet – Frequently Asked Questions\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eWhat are some of the applications for the Thermo 1371 biosafety cabinet? \u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe Thermo Scientific 1371 is a Class II, Type A2 biosafety cabinet. Typical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eCell and tissue culture\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eMicrobiology research\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePharmaceutical and biotechnology workflows\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eClinical laboratory testing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eMolecular biology procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eWhat filtration system does the Thermo 1371 use?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe cabinet uses dual H14 HEPA filters with 99.995% efficiency at the most penetrating particle size (MPPS).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis filtration system:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRemoves airborne contaminants from incoming air\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eMaintains clean laminar airflow across the work surface\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003ePrevents hazardous biological particles from escaping the cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eHow energy efficient is the Thermo Scientific 1371 cabinet?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe 1371 cabinet uses high-efficiency DC blower motors, which can reduce energy consumption by up to 75% compared with traditional AC motor biosafety cabinets, and help lower the ongoing costs of operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eEnergy-saving features include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eReduced electrical consumption\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eLower laboratory HVAC demand\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eExtended HEPA filter life due to stable airflow control\u003cb style=\"font-size: 0.875rem;\"\u003e \u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003cb\u003eHow quiet is the Thermo Scientific 1371?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe cabinet typically operates at approximately 65 dBA, which is considered a low noise level for a biosafety cabinet of this size. While it is impossible for a biosafety cabinet to be completely silent during operation, this unit is relatively quiet.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e \u003c\/p\u003e","brand":"Thermo","offers":[{"title":"$7000","offer_id":40261610307632,"sku":"0870AA BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/DSC_0224.jpg?v=1654282534"},{"product_id":"labconco-purifier-logic-class-ii-type-a2-0883aaa-bio-cab","title":"Labconco Purifier Logic+ Class II\/Type A2","description":"\u003ch2\u003e\u003cstrong\u003eLabconco Purifier Logic+ Biosafety Cabinet\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Labconco Purifier Logic+ Class II\/Type A2 biosafety cabinet uses the Constant Airflow Profile (CAP) to maintain a precise volume of air as the filters load. In addition, the cabinet will continuously display the HEPA filter life remaining and cabinet status. These features combine to provide unparalleled safety.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eLabconco Purifier Logic+ features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCat. No. 302619101\u003c\/li\u003e\n\u003cli\u003e6’ Wide\u003c\/li\u003e\n\u003cli\u003eIncludes stand\u003c\/li\u003e\n\u003cli\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLogic+ Biosafety Cabinets excel in user comfort and functionality. Decades of industry leading advances in ergonomic design have shaped the Inclination Technology Suite that includes the following: 10° angled sash, patented curved air grille with built in armrest, fully accessible controls and eye-level mounted color display with MyLogic operating system.\u003c\/p\u003e\n\u003cp\u003eMyLogic provides intuitive programming, color coded menus, status messages and alarms with diagnostic troubleshooting - all using full sentences. It includes UV light, service fixture, pass through, and sealed duplex receptacle (115V).\u003c\/p\u003e\n\u003ch3\u003e\n\u003cem\u003e\u003cstrong\u003e\u003ca title=\"Link to YouTube\" href=\"https:\/\/youtu.be\/xUQ1kb6mlZE\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003eto see the Labconco Purifier Logic+ on our YouTube channel\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/xUQ1kb6mlZE\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eTesting\u003c\/h3\u003e\n\u003cp\u003eThis Labconco Purifier Logic+ Class II\/Type A2 biosafety cabinet is used and reconditioned.\u003c\/p\u003e\n\u003cp\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003ePictures\u003c\/h3\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment.\u003c\/p\u003e\n\u003cp\u003eWe often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after testing and cleaning.\u003c\/p\u003e\n\u003ch2\u003eLabconco Purifier Logic+ Class II\/Type A2\u003cb\u003e biosafety cabinet\u003c\/b\u003e \u003cstrong\u003e– Specifications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e78.25”W x 31.2”D x 63.4”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorkspace dimensions (height is back\/front)\u003c\/td\u003e\n\u003ctd\u003e72.5”W x 20.5D x 25”\/28.25”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash opening\u003c\/td\u003e\n\u003ctd\u003e10”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e902 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e115 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFor inquiries about the Labconco Purifier Logic+ Class II, Type A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e","brand":"Labconco","offers":[{"title":"Default Title","offer_id":40692858716208,"sku":"0883AAA BIO CAB","price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/DSC_0939_68a4292d-bb92-4811-8a6f-ca97b5cffa75.jpg?v=1671736855"},{"product_id":"thermo-scientific-1345-4-type-a2-biosafety-cabinet-w-stand-0870ee-bio-cab","title":"Thermo Scientific 1345 biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1345 4’ A2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1345 biosafety cabinets incorporate advanced brushless DC motor technology, significantly improving energy efficiency, safety, and reliability. These DC motors not only reduce energy costs but also enhance overall system dependability while lowering air conditioning expenses. Additionally, they optimize environmental protection, making them a sustainable choice for your laboratory.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTo further increase energy efficiency, the cabinets include a night-set-back mode that maintains a clean workspace while conserving energy. When the front sash is closed, the intelligent speed control system automatically decreases the blower speed to 30%.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis feature extends the life of the HEPA filter and ensures a sterile work environment even during downtime. Compared to similar models, this reduced flow mode is 75% more energy efficient, offering unmatched performance and operational cost savings.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1345 4’ Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e4’ wide (74.8” exterior)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStainless-steel chamber\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/youtu.be\/mmLapFH_5qo\" title=\"Link to YouTube\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003e to see the Thermo 1300 Series 4' A2 biosafety cabinet on our YouTube channel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/mmLapFH_5qo?si=x_D5dLyxFLyhN1bu\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1345 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 1300 Series A2 biosafety cabinets elevate safety and containment through an innovative airflow system. Independent supply and exhaust blowers automatically balance downflow and inflow\/exhaust velocities, ensuring consistently safe working conditions. This advanced design provides reliable protection for both users and samples.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor added comfort, the Thermo 1345 biosafety cabinet features a 10° front slope that minimizes operator fatigue during extended use. The reduced noise level creates a focused work environment free from distractions, while the spacious, unobstructed work surface enhances both productivity and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAdditionally, the flat, single-piece stainless steel work tray simplifies cleaning, saving time and effort. Thoughtfully designed armrests sit above the intake grill, enabling users to reach further into the cabinet while maintaining safe airflow, ensuring both comfort and protection.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1345 4’ Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific 1345 – Additional Specifications\u003c\/h3\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51.2”W x 31.75”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork area dimensions\u003c\/td\u003e\n\u003ctd\u003e47.2”W x 24.8”D x 30.7”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash height\u003c\/td\u003e\n\u003ctd\u003e10”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e441 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e Thermo 1345 4’ Biosafety Cabinet - Pictures\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1345 4’ A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific 1345 biosafety cabinet frequently asked questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eCan you provide more pictures of the Thermo 1345? I want to see the exact unit I’m purchasing. \u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAbsolutely. The pictures on our website are representative and all of our equipment comes fully cleaned – we want the equipment to look it’s best when installed in your lab. We’re happy to send pictures of a specific unit so that you can see the condition prior to purchase\/shipping. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eI’m trying to decide between a 6’ wide biosafety cabinet and a 4’ wide biosafety cabinet. Do you have any suggestions?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you have the space and budget, and all other factors being equal, we generally recommend going with the largest biosafety cabinet you can fit in your lab. This will provide your lab personnel with flexibility and space to work. Operating costs between a 6’ and 4’ model of the same brand\/vintage are minimal, as are replacement filters. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eDo you offer white glove delivery service for biosafety cabinets like the Thermo 1345? \u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor customers in New England our movers can bring biosafety cabinets into the lab and set the units in place on the stands, after which \u003ca href=\"https:\/\/aielaboratoryservices.com\/testingcertification\/\" target=\"_blank\" rel=\"noopener\"\u003eour certifiers\u003c\/a\u003e are able to make sure the unit is fully functional and operating to specification.  \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you are outside of New England please contact our sales team – we may be able to offer a recommendation on a local moving company or other provider to assist you with installation of the BSC. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":40892083503152,"sku":"0870EE BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/0870yy-1_6129e1ce-175c-42f6-a20a-715a6814bf32.jpg?v=1695837112"},{"product_id":"thermo-1307-6-biosafety-cabinet-0870f-bio-cab","title":"Thermo Scientific 1307 biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1307 6' A2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1307 biosafety cabinets incorporate advanced brushless DC motor technology, significantly improving energy efficiency, safety, and reliability. These DC motors not only reduce energy costs but also enhance overall system dependability while lowering air conditioning expenses. Additionally, they optimize environmental protection, making them a sustainable choice for your laboratory.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTo further increase energy efficiency, the cabinets include a night-set-back mode that maintains a clean workspace while conserving energy. When the front sash is closed, the intelligent speed control system automatically decreases the blower speed to 30%.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis feature extends the life of the HEPA filter and ensures a sterile work environment even during downtime. Compared to similar models, this reduced flow mode is 75% more energy efficient, offering unmatched performance and operational cost savings.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1307 6' Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ wide (74.8” exterior)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStainless-steel chamber\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/youtu.be\/qGFQrj4ige8\" title=\"Link to YouTube\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003eto see the Thermo Scientific 6' 1300 Series A2 biosafety cabinet on our YouTube channel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/qGFQrj4ige8?si=LrpSyuIRgfKz3cEJ\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1307 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 1300 Series A2 biosafety cabinets elevate safety and containment through an innovative airflow system. Independent supply and exhaust blowers automatically balance downflow and inflow\/exhaust velocities, ensuring consistently safe working conditions. This advanced design provides reliable protection for both users and samples.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor added comfort, the Thermo 1307 biosafety cabinet features a 10° front slope that minimizes operator fatigue during extended use. The reduced noise level creates a focused work environment free from distractions, while the spacious, unobstructed work surface enhances both productivity and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAdditionally, the flat, single-piece stainless steel work tray simplifies cleaning, saving time and effort. Thoughtfully designed armrests sit above the intake grill, enabling users to reach further into the cabinet while maintaining safe airflow, ensuring both comfort and protection.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1307 6' Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1307 – Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e74.8”W x 31.75”D x 61.8”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork area dimensions\u003c\/td\u003e\n\u003ctd\u003e70.5”W x 17.5”D x 30.7\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash height\u003c\/td\u003e\n\u003ctd\u003e8”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1307 6' Biosafety Cabinet - Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1307 6' A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/thermo-scientific-1300-series-bio-safety-cabinet\/\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003eto read a review of this product on our blog!\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo Scientific model 1307 biosafety cabinet frequently asked questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003ci\u003eI’m seeing a “CAL” error or other malfunction on my Thermo 1307 biosafety cabinet. Do you offer technical support?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eOur \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/lab-equipment-repair-services\"\u003etechnicians\u003c\/a\u003e and \u003ca href=\"https:\/\/aielaboratoryservices.com\/testingcertification\/\" target=\"_blank\" rel=\"noopener\"\u003ecertifiers\u003c\/a\u003e are available for repair assistance, but technical support by phone is not recommended. We strongly encourage you to contact your local certifiers or the team at AIE Laboratory Services for on site diagnosis and repair.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eDo you sell parts for the Thermo 1307 biosafety cabinet, like sashes or HEPA filters?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eWe typically do not sell parts for these units but prefer to keep any spare parts to help refurbished additional models that come our way. We may be able to assist in sourcing parts for you, depending on the circumstances. Please contact us regarding with specifics for more information.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWe install new filters in every biosafety cabinet we sell, but we purchase these directly from the manufacturer or other non-OEM source. If you are looking for new HEPA filters we suggest contacting the manufacturer directly.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRemember that biosafety cabinets also need to be decontaminated with chlorine dioxide to prevent contamination before opening the filter housing. If you’re in New England, our team at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\" target=\"_blank\" rel=\"noopener\"\u003eAIE Laboratory Services\u003c\/a\u003e is available for HEPA filter replacement and certifications.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\n\u003ci\u003eI need multiple biosafety cabinets for my new lab. Are you able to supply several matching Thermo 1307 cabinets?\u003c\/i\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes, we frequently outfit new labs with multiple pieces of equipment. We encourage you to check out some of the \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/biotech-start-up-equipment-packages\"\u003elab equipment start up packages\u003c\/a\u003e from American Instrument Exchange. These include not only biosafety cabinets but incubators, centrifuges, microscopes, and more. We offer easy customization to match your specific budget, brand preferences, and research requirements.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"$7000 \/ 11-20-2024","offer_id":40941469007920,"sku":"0870F BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0782_108c548a-8ce6-4736-a46c-3c03c2e1afc8.jpg?v=1704811462"},{"product_id":"baker-sterilgard-e3-sg504-biosafety-cabinet","title":"Baker SterilGARD e3 SG504 Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG504 Biosafety Cabinet\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD e3 SG504 is the most energy efficient biosafety cabinet available today. The newly redesigned airflow management system saves energy and improves both user comfort and safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SG504 achieves maximum user protection through six technologies working in concert. Momentum air curtain, high-velocity return air slots, aerodynamically designed airfoil, optimized downflow, and unique air bypass armrest.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe energy saving features provide up to 60% increased energy efficiency when compared to similar biosafety cabinets and extend HEPA filter lifespan by up to 30%.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG504 Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type A2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e5’ wide (65.75” exterior, 58” work surface)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eVertical laminar flow hood\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes new supply and exhaust HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG504 Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD e3 SG504 features the new trademarked ReadySAFE mode. A unique padded armrest allows the cabinet to maintain A2 conditions with the viewscreen in the close position. When the sash is lifted, the cabinet is instantly safe upon resuming standard operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe versatile ReadySAFE mode is designed to be used during breaks (even extended breaks such as overnight) to maintain safe conditions and save energy.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe audible and visual alarms alert the operator of some unsafe conditions including power\/processor fault alarm, viewscreen alarm, and double viewscreen position sensor fault alarm.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach SG504 cabinet has one cable port located in the right sidewall. This provides a safe means of introducing power cables, tubing or other similar items into the work area. It is designed with flexible neoprene seals allowing multiple cables and\/or tubing totaling up to 1 inch in diameter.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe operator controls and indicators are arranged in a single, easily cleaned membrane switch assembly on the front of the cabinet. There are pushbuttons for blower, fluorescent light, outlets, optional ultraviolet light and alarm mute.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe motor and blower are a single assembly and balanced to minimize vibration. The motor control automatically compensates for increased pressure drop across the filters without significantly reducing the total air flow rate. The air flow capacity of the cabinet is measured by the ability to provide a nearly constant volume of air as the filter resistance to airflow increases.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SG504 Testing\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company,\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/aielaboratoryservices.com\/\" rel=\"noopener\" target=\"_blank\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBaker SterilGARD e3 SG504 – Additional Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" border=\"1\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions (not including stand)\u003c\/td\u003e\n\u003ctd\u003e65.75”W x 31”D x 61.75”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior work surface dimensions\u003c\/td\u003e\n\u003ctd\u003e58”W x 24.5”D x 27.5”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (not including stand)\u003c\/td\u003e\n\u003ctd\u003eApprox 680 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements (call or email to confirm)\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 20 amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eBaker SterilGARD e3 SG504 Biosafety Cabinet – Frequently Asked Questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h2\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhat is the Baker SterilGARD e3 SG504 biosafety cabinet?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThe Baker SterilGARD e3 SG504 is a Class II Type A2 biosafety cabinet designed to provide personnel, product, and environmental protection through controlled airflow and HEPA filtration. It meets NSF\/ANSI 49 standards and is suitable for Biosafety Levels 1–3 applications including microbiology, virology, and pharmaceutical work. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eIf you’re not sure what type of biosafety cabinet you need – Type A2 or Type B2 – please contact either the sales team at \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003eAmerican Instrument Exchange\u003c\/a\u003e or the technicians at \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e for more information and guidance. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eHow does the airflow system in the SG504 work?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eLike all Class II Type A2 biosafety cabinet, the Baker SG504 uses a vertical laminar airflow system with a carefully balanced recirculation pattern:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRoom air enters at ~100–105 feet per minute through the front opening \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHEPA-filtered air flows downward in a unidirectional stream \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e~70% of air is recirculated; ~30% is exhausted through a HEPA filter \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eA momentum air curtain and high-velocity return slots enhance containment \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThis design ensures contaminants are captured while maintaining a sterile work area.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhat level of filtration does the SG504 provide?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThe cabinet uses dual HEPA filters (supply and exhaust) that are:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e99.99% efficient at 0.3 microns (most penetrating particle size) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eIndividually leak-tested before shipment \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eDesigned for both product and environmental protection \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThis level of filtration is critical for maintaining sterile conditions in sensitive lab workflows. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhat makes the SterilGARD e3 series unique compared to other biosafety cabinets?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThe SG504 and other Baker x04 biosafety cabinets incorporate several proprietary technologies, including:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo3; tab-stops: list .5in;\"\u003eStediFLOW™ airflow system for consistent performance as filters load \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo3; tab-stops: list .5in;\"\u003eUniPressure™ plenum design for stable airflow balance \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo3; tab-stops: list .5in;\"\u003eMomentum air curtain for improved operator protection \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l5 level1 lfo3; tab-stops: list .5in;\"\u003eHigh-velocity return air slots to capture contaminants quickly \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThese features work together to improve containment, reduce turbulence, and simplify certification.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eHow energy efficient is the SG504 biosafety cabinet?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThe SterilGARD e3 platform is engineered for low energy consumption and reduced operating costs, offering:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo4; tab-stops: list .5in;\"\u003eSignificant reductions in energy use compared to traditional cabinets \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo4; tab-stops: list .5in;\"\u003eLower heat output, improving lab comfort \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo4; tab-stops: list .5in;\"\u003eExtended HEPA filter life due to optimized airflow \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eSome configurations report substantial annual energy savings due to efficient motor and airflow control systems. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eCan the SG504 be ducted or used recirculating?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eYes. Like all Class II Type A2 cabinets, the SG504 can recirculate air back into the laboratory or connect to an external exhaust system via a canopy. This flexibility allows it to fit a wide range of lab designs and safety requirements. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhat applications is the SG504 best suited for?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThe SG504 is commonly used in \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/cell-culture-lab-equipment\"\u003ecell and tissue culture\u003c\/a\u003e, microbiology and virology labs, \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eclinical diagnostics, pharmaceutical and \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/biotech-start-up-equipment-packages\"\u003ebiotech research\u003c\/a\u003e, and more. It is designed for applications requiring both contamination control and operator protection.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eHow easy is maintenance and certification?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eThe SterilGARD e3 is designed for simplified maintenance. Our \u003ca href=\"https:\/\/aielaboratoryservices.com\/repairreplacement\/\"\u003erepair technicians\u003c\/a\u003e appreciate all of the features that make these units easy to maintain, including front-access HEPA filters for faster replacement, adjustable internal damper for airflow balancing, accessible components for certification testing. These features reduce downtime and service costs over the life of the cabinet. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhy buy a refurbished SG504 instead of new?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eA professionally refurbished SG504 can deliver:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l4 level1 lfo5; tab-stops: list .5in;\"\u003eSignificant cost savings compared to new units \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l4 level1 lfo5; tab-stops: list .5in;\"\u003eVerified performance and tested airflow systems \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l4 level1 lfo5; tab-stops: list .5in;\"\u003eFaster availability vs. long OEM lead times \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhen \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/refurbished-biological-safety-cabinets?srsltid=AfmBOop4LRh3uPxX3mqJfyz3wPbNgONW_42vPHzSOz0hBUs3s8JhH22W\"\u003eproperly refurbished\u003c\/a\u003e, these cabinets provide equivalent functional performance at a fraction of the cost.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eWhy choose American Instrument Exchange instead of an auction or unknown seller?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eNot all “used biosafety cabinets” are equal. Buying from a trusted supplier like American Instrument Exchange helps ensure:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo6; tab-stops: list .5in;\"\u003eVerified HEPA filter integrity and airflow performance \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo6; tab-stops: list .5in;\"\u003eProper decontamination and cleaning \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo6; tab-stops: list .5in;\"\u003eFunctional alarms, controls, and safety systems \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo6; tab-stops: list .5in;\"\u003eReduced risk of certification failure after delivery \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003eIn contrast, auction equipment is often sold untested, uncertified, and without safety validation, which can lead to costly repairs or compliance issues.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"American Instrument Exchange","offers":[{"title":"Default Title","offer_id":42043637596208,"sku":"0877M BIO CAB","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0567a.jpg?v=1749131399"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/collections\/DSC_0784.jpg?v=1735329721","url":"https:\/\/www.americaninstrument.com\/collections\/biohoods-clean-benches\/4%27+biocab.oembed","provider":"American Instrument Exchange","version":"1.0","type":"link"}