{"title":"Class II Type B2 biosafety cabinets","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAmerican Instrument offers used and refurbished biosafety cabinets for sale, designed to protect personnel, samples, and laboratory environments. Our inventory includes biosafety cabinets from \u003ca title=\"Refurbished Baker Biosafety cabinets\" href=\"https:\/\/www.americaninstrument.com\/search?q=product_type%3ABiohoods%2FClean+Benches+AND+baker\"\u003eBaker\u003c\/a\u003e, \u003ca title=\"Refurbished Labconco biosafety cabinets\" href=\"https:\/\/www.americaninstrument.com\/search?q=product_type%3ABiohoods%2FClean+Benches+AND+labconco\"\u003eLabconco\u003c\/a\u003e, \u003ca title=\"Refurbished Nuaire biosafety cabinets\" href=\"https:\/\/www.americaninstrument.com\/search?q=product_type%3ABiohoods%2FClean+Benches+AND+nuaire\"\u003eNuAire\u003c\/a\u003e, and \u003ca title=\"Refurbished Thermo Scientific biosafety cabinets\" href=\"https:\/\/www.americaninstrument.com\/search?q=product_type%3ABiohoods%2FClean+Benches+AND+thermo\"\u003eThermo Scientific\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClass II, Type B2 Biosafety Cabinets (BSCs) provide comprehensive personnel, product and environmental protection from hazardous particulates, including agents requiring BSL 1-4 containment. They are sometimes referred to as 100% Exhaust or Total Exhaust biosafety cabinet. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eB2 cabinets are ideal for scenarios where chemical fumes are involved in microbiological research. They require higher energy consumption and specialized HVAC planning compared to Type A2 cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAt American Instrument, we have a long history of \u003ca title=\"Used and Refurbished Biosafety Cabinets\" href=\"https:\/\/blog.americaninstrument.com\/used-and-refurbished-biosafety-cabinets\/\" target=\"_blank\"\u003erefurbishing used biosafety cabinets\u003c\/a\u003e. Our technicians test each BSC to ensure that the controls and blower motor work properly. Unless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment. Our testing procedure includes all elements of a \u003ca title=\"Biosafety cabinet certification\" href=\"https:\/\/aielaboratoryservices.com\/testingcertification\/\" target=\"_blank\"\u003ebiosafety cabinet certification\u003c\/a\u003e to ensure the unit passes certification upon arrival at your site.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eSpecifications are provided to assist with planning and installation.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"baker-sg-603tx-sterilgard-iii-0887-bio-cab","title":"Baker Sg-603TX Sterilgard III biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Class II Type B2 Biosafety Cabinet – Refurbished\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD III SG603-TX biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment performance. Commonly used for pharmaceutical research, hazardous drug handling, toxicology applications, microbiology workflows, and biotechnology procedures involving volatile toxic chemicals or trace chemical vapors, this refurbished Baker biosafety cabinet offers advanced containment performance for laboratories requiring a Class II Type B2 configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG603-TX is part of Baker’s SterilGARD III TX-series and is specifically configured as a ducted Class II Type B2 biosafety cabinet for applications involving biological materials alongside hazardous chemical vapors or toxic compounds. Baker TX-series cabinets have been widely used throughout pharmaceutical facilities, toxicology laboratories, hospital research environments, biotechnology laboratories, and academic research institutions because of their durable welded-steel construction, stable airflow performance, and total exhaust containment capability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAt \u003ca href=\"https:\/\/www.americaninstrument.com\/\"\u003eAmerican Instrument Exchange\u003c\/a\u003e, each animal transfer station is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories and vivarium facilities outfitting containment-focused workflows may also browse additional refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003elaboratory incubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003efreezers\u003c\/a\u003e available through American Instrument Exchange..\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Key Features\u003c\/h3\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eBaker SterilGARD III TX-series biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eClass II Type B2 biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e6-foot workspace configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e100% total exhaust airflow design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for hard-ducted exhaust operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for trace chemical and toxicology applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePressure-resistant plenum design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eStainless steel interior work surface\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNSF\/ANSI 49 compliant design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes stand and new HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e90-day warranty included from American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefurbished and tested by American Instrument Exchange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Overview\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD III SG603-TX is a 6-foot Class II Type B2 biosafety cabinet engineered for laboratory environments requiring contamination control, sterile airflow, operator protection, and total exhaust containment capability. Unlike recirculating Type A2 biosafety cabinets, the SG603-TX is designed for hard-ducted operation and exhausts 100% of cabinet airflow through a dedicated facility exhaust system without internal recirculation inside the work area.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis configuration may make the SG603-TX especially appropriate for laboratory procedures involving volatile toxic chemicals, trace hazardous vapors, pharmaceutical compounding, toxicology workflows, radionuclides, microbiology procedures, and biotechnology applications requiring maximum exhaust containment performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBaker TX-series cabinets were developed for laboratory environments where biological containment must be combined with safe handling of hazardous chemical vapors. Because the cabinet exhausts all contaminated air through a dedicated facility exhaust connection, it may provide additional protection for applications that are not appropriate for standard recirculating Type A2 biosafety cabinets.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG603-TX operates using a HEPA-filtered airflow system designed to maintain ISO Class 5 work area conditions while supporting containment protection for biological workflows. Features may include pressure-resistant plenums, stainless steel interior construction, fluorescent lighting, airflow monitoring systems, removable work trays, ergonomic sash positioning, and heavy-duty welded-steel cabinet construction depending on the specific configuration of the unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe large 6-foot workspace may make this biosafety cabinet especially appropriate for laboratories requiring substantial containment workspace for pharmaceutical preparation, toxicology studies, staged workflows, or high-throughput biological procedures involving hazardous compounds.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eLaboratories outfitting complete containment workflows may also be interested in refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/co2-incubators\"\u003eCO2 incubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/ultra-low-freezers\"\u003eultra-low freezers\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/autoclaves-sterilizers\"\u003eautoclaves\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/water-baths-and-circulators\"\u003ewater baths\u003c\/a\u003e available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Common Applications\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD III SG603-TX biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, contamination control, and total exhaust operation. Typical applications may include hazardous drug handling, toxicology workflows, microbiology procedures involving volatile toxic chemicals, pharmaceutical preparation, biotechnology research, biological sample handling, and radionuclide applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may also be appropriate for pharmaceutical production facilities, toxicology laboratories, biotechnology laboratories, hospital pharmacies, clinical testing laboratories, academic research facilities, and cleanroom environments requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Ideal Laboratory Environments\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may be suitable for pharmaceutical production facilities, toxicology laboratories, biotechnology laboratories, hospital research environments, academic research facilities, cleanrooms, and containment-focused laboratory applications requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts total exhaust airflow configuration and large 6-foot workspace may make it especially appropriate for laboratories requiring additional chemical containment capability combined with expanded working area for larger procedures or multiple operators.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Key Specifications\u003c\/h3\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBaker\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSterilGARD III SG603-TX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCabinet Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Width\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e6 ft\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow Design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100% total exhaust\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExhaust Requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHard-ducted facility exhaust connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConfiguration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTX-series toxicology \/ trace chemical compatible design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExterior Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 78” W × 34” D × 61” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInterior Work Area Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 70” W × 24” D × 28” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 850 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSash Opening\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 10 in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFiltration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHEPA supply and exhaust filtration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e115V, 60Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStand and new HEPA filters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e90-day warranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCondition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefurbished\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003eSpecifications compiled from Baker manufacturer literature, distributor technical references, and American Instrument Exchange product information.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Refurbishment and Testing\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange has extensive experience refurbishing used biosafety cabinets and laboratory containment equipment for research and pharmaceutical environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach biosafety cabinet is inspected by our technicians to verify proper blower operation, airflow performance, sash operation, control operation, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTesting procedures include major functional and airflow verification elements associated with biosafety cabinet performance to help support certification readiness upon installation at your facility. Because this is a ducted Class II Type B2 biosafety cabinet, final certification should be completed after exhaust connection and installation by qualified field technicians in accordance with laboratory requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Certification Readiness\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2 biosafety cabinets should be certified by qualified field technicians after installation and exhaust connection before laboratory use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, exhaust requirements, airflow requirements, electrical requirements, and certification standards prior to installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification services are available throughout New England through \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification requirements may vary depending on laboratory protocols, toxicology workflows, facility standards, and application requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Shipping and Installation Considerations\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, exhaust compatibility, electrical compatibility, and final cabinet placement before shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause this is a ducted Class II Type B2 biosafety cabinet, installation should be coordinated with facility engineering personnel or qualified biosafety cabinet service providers to confirm proper exhaust integration and airflow performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDepending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe large 6-foot cabinet configuration may require additional planning for transport and positioning within laboratory facilities.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG603-TX Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhy would a laboratory choose the SG603-TX instead of a standard Type A2 biosafety cabinet?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG603-TX is designed for workflows involving hazardous vapors or trace chemicals used alongside biological materials. Because it operates as a total exhaust Class II Type B2 cabinet, it may be more appropriate for toxicology applications, hazardous drug preparation, and pharmaceutical workflows that are not suitable for recirculating Type A2 cabinets.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the SG603-TX require a dedicated exhaust connection?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. The SG603-TX is a hard-ducted Class II Type B2 biosafety cabinet and must be connected to an appropriate facility exhaust system before operation and certification.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhy do some pharmaceutical laboratories prefer large 6-foot Type B2 cabinets?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA 6-foot Type B2 cabinet provides substantially more workspace for staged materials, larger procedures, multiple operators, or complex pharmaceutical and toxicology workflows requiring total exhaust containment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eCan the SG603-TX be used for hazardous drug compounding?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eDepending on institutional protocols and facility engineering standards, the SG603-TX may be appropriate for hazardous drug handling and pharmaceutical preparation workflows requiring total exhaust containment capability.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes American Instrument Exchange replace HEPA filters before shipment?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Unless otherwise specified, American Instrument Exchange installs new HEPA filters before shipment. Cabinets are inspected and tested by our technicians prior to delivery to help support certification readiness after installation.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat testing does American Instrument Exchange perform during refurbishment?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange technicians inspect airflow systems, blower operation, sash functionality, cabinet controls, lighting systems, and overall cabinet condition prior to shipment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eCan American Instrument Exchange help coordinate biosafety cabinet certification?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Certification services are available through \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, which provides biosafety cabinet certification, preventative maintenance, repair, testing, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the cabinet include a warranty?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. A 90-day warranty from American Instrument Exchange is included.\u003cem\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=EKmHAyUHo_Y\u0026amp;feature=youtu.be\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to see the Baker SterilGARD SG-603TX on the American Instrument Exchange YouTube channel.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/EKmHAyUHo_Y\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/americaninstrument.info\/baker-sterilchemgard-iii-advance-sg603tx-total-exhaust-bio-safety-cabinet\/\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to read a review of this product on our blog!\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$7500.00","offer_id":28870123061296,"sku":"0887 BIO CAB","price":8900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0887_BIO_CAB.jpg?v=1560350970"},{"product_id":"baker-sg-403tx-sterilgard-iii-0887a-bio-cab","title":"Baker SG-403TX Sterilgard III biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Class II Type B2 Biosafety Cabinet – Refurbished\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD III SG403-TX biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment performance. Commonly used for pharmaceutical research, hazardous drug handling, toxicology applications, microbiology workflows, and biotechnology procedures involving volatile toxic chemicals or trace chemical vapors, this refurbished Baker biosafety cabinet offers advanced containment performance for laboratories requiring a Class II Type B2 configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG403-TX is part of Baker’s SterilGARD III TX-series and is specifically configured as a ducted Class II Type B2 biosafety cabinet for applications involving biological materials alongside hazardous chemical vapors or toxic compounds. Baker TX-series cabinets have been widely used throughout pharmaceutical facilities, toxicology laboratories, hospital research environments, biotechnology laboratories, and academic research institutions because of their durable welded-steel construction, stable airflow performance, and total exhaust containment capability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAt \u003ca href=\"https:\/\/www.americaninstrument.com\/\"\u003eAmerican Instrument Exchange\u003c\/a\u003e, each animal transfer station is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories and vivarium facilities outfitting containment-focused workflows may also browse additional refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003elaboratory incubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003efreezers\u003c\/a\u003e available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Key Features\u003c\/h3\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eBaker SterilGARD III TX-series biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eClass II Type B2 biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e4-foot workspace configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e100% total exhaust airflow design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for hard-ducted exhaust operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for trace chemical and toxicology applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePressure-resistant plenum design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eStainless steel interior work surface\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNSF\/ANSI 49 compliant design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes stand and new HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e90-day warranty included from American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefurbished and tested by American Instrument Exchange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Overview\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD III SG403-TX is a 4-foot Class II Type B2 biosafety cabinet engineered for laboratory environments requiring contamination control, sterile airflow, operator protection, and total exhaust containment capability. Unlike recirculating Type A2 biosafety cabinets, the SG403-TX is designed for hard-ducted operation and exhausts 100% of cabinet airflow through a dedicated facility exhaust system without internal recirculation inside the work area.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis configuration may make the SG403-TX especially appropriate for laboratory procedures involving volatile toxic chemicals, trace hazardous vapors, pharmaceutical compounding, toxicology workflows, radionuclides, microbiology procedures, and biotechnology applications requiring maximum exhaust containment performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBaker TX-series cabinets were developed for laboratory environments where biological containment must be combined with safe handling of small quantities of hazardous chemical vapors. Because the cabinet exhausts all contaminated air through a dedicated facility exhaust connection, it may provide additional protection for applications that are not appropriate for standard recirculating Type A2 biosafety cabinets.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG403-TX operates using a HEPA-filtered airflow system designed to maintain ISO Class 5 work area conditions while supporting containment protection for biological workflows. Features may include pressure-resistant plenums, stainless steel interior construction, fluorescent lighting, airflow monitoring systems, removable work trays, ergonomic sash positioning, and heavy-duty welded-steel cabinet construction depending on the specific configuration of the unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe compact 4-foot footprint may make this biosafety cabinet especially appropriate for laboratories requiring total exhaust containment capability while conserving valuable laboratory floor space.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eLaboratories outfitting complete containment workflows may also be interested in refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/co2-incubators\"\u003eCO2 incubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/ultra-low-freezers\"\u003eultra-low freezers\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/autoclaves-sterilizers\"\u003eautoclaves\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/water-baths-and-circulators\"\u003ewater baths\u003c\/a\u003e available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Common Applications\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Baker SterilGARD III SG403-TX biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, contamination control, and total exhaust operation. Typical applications may include hazardous drug handling, toxicology workflows, microbiology procedures involving volatile toxic chemicals, pharmaceutical preparation, biotechnology research, biological sample handling, and radionuclide applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may also be appropriate for pharmaceutical production facilities, toxicology laboratories, biotechnology laboratories, hospital pharmacies, clinical testing laboratories, academic research facilities, and cleanroom environments requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Ideal Laboratory Environments\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may be suitable for pharmaceutical production facilities, toxicology laboratories, biotechnology laboratories, hospital research environments, academic research facilities, cleanrooms, and containment-focused laboratory applications requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts total exhaust airflow configuration may make it especially appropriate for laboratories requiring additional chemical containment capability beyond standard recirculating biosafety cabinet systems.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Key Specifications\u003c\/h3\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBaker\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSterilGARD III SG403-TX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCabinet Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Width\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e4 ft\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow Design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100% total exhaust\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExhaust Requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHard-ducted facility exhaust connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConfiguration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTX-series toxicology \/ trace chemical compatible design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExterior Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 53” W × 30” D × 58” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInterior Work Area Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 46” W × 25” D × 27.5” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 525 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSash Opening\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 10 in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFiltration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHEPA supply and exhaust filtration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e115V, 60Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStand and new HEPA filters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e90-day warranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCondition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefurbished\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003eSpecifications compiled from Baker manufacturer literature, distributor technical references, and American Instrument Exchange product information.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Refurbishment and Testing\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange has extensive experience refurbishing used biosafety cabinets and laboratory containment equipment for research and pharmaceutical environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach biosafety cabinet is inspected by our technicians to verify proper blower operation, airflow performance, sash operation, control operation, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTesting procedures include major functional and airflow verification elements associated with biosafety cabinet performance to help support certification readiness upon installation at your facility. Because this is a ducted Class II Type B2 biosafety cabinet, final certification should be completed after exhaust connection and installation by qualified field technicians in accordance with laboratory requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Certification Readiness\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2 biosafety cabinets should be certified by qualified field technicians after installation and exhaust connection before laboratory use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, exhaust requirements, airflow requirements, electrical requirements, and certification standards prior to installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification services are available throughout New England through \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification requirements may vary depending on laboratory protocols, toxicology workflows, facility standards, and application requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Shipping and Installation Considerations\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, exhaust compatibility, electrical compatibility, and final cabinet placement before shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause this is a ducted Class II Type B2 biosafety cabinet, installation should be coordinated with facility engineering personnel or qualified biosafety cabinet service providers to confirm proper exhaust integration and airflow performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDepending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SterilGARD III SG403-TX Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat makes the SG403-TX different from a standard Baker SG403A biosafety cabinet?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG403-TX is a Class II Type B2 biosafety cabinet designed for total exhaust operation, while standard SG403A cabinets are recirculating Type A2 models. The TX configuration is intended for workflows involving trace hazardous vapors or toxicology applications.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the SG403-TX require a dedicated exhaust system?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. The SG403-TX is a hard-ducted Class II Type B2 biosafety cabinet and must be connected to an appropriate facility exhaust system before operation and certification.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat types of laboratory procedures commonly use the SG403-TX?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SG403-TX may be used for pharmaceutical compounding, toxicology workflows, microbiology applications involving volatile toxic chemicals, radionuclide procedures, and biotechnology research requiring total exhaust containment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhy would a laboratory choose a 4-foot Type B2 cabinet?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA 4-foot Type B2 cabinet provides total exhaust containment capability while conserving laboratory floor space. Many laboratories choose smaller B2 cabinets when workflows do not require larger 5-foot or 6-foot containment systems.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes American Instrument Exchange replace HEPA filters before shipment?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Unless otherwise specified, American Instrument Exchange installs new HEPA filters before shipment. Cabinets are inspected and tested by our technicians prior to delivery to help support certification readiness after installation.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat testing does American Instrument Exchange perform during refurbishment?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange technicians inspect airflow systems, blower operation, sash functionality, cabinet controls, lighting systems, and overall cabinet condition prior to shipment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eCan American Instrument Exchange help coordinate biosafety cabinet certification?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Certification services are available through \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, which provides biosafety cabinet certification, preventative maintenance, repair, testing, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the cabinet include a warranty?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. A 90-day warranty from American Instrument Exchange is included.\u003c\/p\u003e","brand":"Baker","offers":[{"title":"$7900.00","offer_id":28870132203568,"sku":"0887A BIO CAB","price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0887A_BIO_CAB.jpg?v=1560351154"},{"product_id":"nuaire-430-600-0875i-bio-cab","title":"Nuaire NU-430-600 biological safety cabinet","description":"\u003ch2\u003eNuaire NU-430-600 Class II Type B2 6' biological safety cabinet\u003c\/h2\u003e\n\u003cp\u003eThe Nuaire NU-430-600 Class II Type B2 biological safety cabinet is a total exhaust cabinet.\u003c\/p\u003e\n\u003cp\u003eWidely used in toxicology laboratories and other applications in which chemical effluent is present and clean air is essential, the Nuaire NU-430-600 recirculates 0% air, as the exhausted air is pulled through a dedicated exhaust duct into the facility exhaust system. (In other words, hard ducted to outside the facility, similar to a chemical fume hood.)\u003c\/p\u003e\n\u003ch3\u003e Nuaire NU-430-600 biological safety cabinet features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClass II Type B2 total exhaust bio safety cabinet\u003c\/li\u003e\n\u003cli\u003e6’ wide model (78” exterior, 70” work surface)\u003c\/li\u003e\n\u003cli\u003eMicroprocessor controller\u003c\/li\u003e\n\u003cli\u003eStand, power cord and manual included\u003c\/li\u003e\n\u003cli\u003e90 day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe entire cabinet shell and all internal plenums and structures on the Nuaire NU-430-600 are constructed from Type 304 stainless steel for increased chemical resistance to acids\/solvents which are normally used in applications which require a fume hood.\u003c\/p\u003e\n\u003ch3\u003e Nuaire NU-430-600 testing\u003c\/h3\u003e\n\u003cp\u003eUnless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment.\u003c\/p\u003e\n\u003cp\u003eLimit testing procedures for B2 biosafety cabinets. We cannot replicate external ducting. We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n\u003ch3\u003eNuaire NU-430-600 Class II Type B2 BSC specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"80%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eExterior WxHxD (not including stand)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e78” x 61” x 33”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterior work surface WxHxD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e70” x 25.5” x 23.5”\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (unpacked)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eapprox 710 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectrical Requirements (call to confirm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e115V, 60Hz, 15 Amp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePlease call or email us today for pricing and additional information regarding the Nuaire NU-430-600.\u003c\/p\u003e\n\u003ch3\u003eNuAire NU-430-600 Biosafety Cabinet – Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4 data-section-id=\"o9f40y\" data-start=\"806\" data-end=\"845\"\u003eWhat does “Class II, Type B2” mean? What's the difference between that and a Type A2 model? \u003c\/h4\u003e\n\u003cp data-start=\"846\" data-end=\"873\"\u003eA Class II Type B2 cabinet:\u003c\/p\u003e\n\u003cul data-start=\"874\" data-end=\"1113\"\u003e\n\u003cli data-section-id=\"kc5c4w\" data-start=\"874\" data-end=\"940\"\u003eProvides triple protection (personnel, product, environment)\u003c\/li\u003e\n\u003cli data-section-id=\"1btpgwq\" data-start=\"941\" data-end=\"997\"\u003eExhausts 100% of air externally (no recirculation)\u003c\/li\u003e\n\u003cli data-section-id=\"rl8uon\" data-start=\"998\" data-end=\"1113\"\u003eIs suitable for toxic chemicals, radionuclides, and infectious agents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eClass II Type A2 units are much more commonly found in working laboratories. The Type A2 model is a 70%\/30% recirculating set up, with air flow passing through the dual HEPA filters and recirculating back into the lab. Ducting is not required for Class II Type A2 models. \u003c\/p\u003e\n\u003ch4 data-section-id=\"lfhwjw\" data-start=\"1120\" data-end=\"1167\"\u003eWhat applications is the Nuaire NU-430-600 cabinet used for?\u003c\/h4\u003e\n\u003cp data-start=\"1168\" data-end=\"1188\"\u003eCommon uses include:\u003c\/p\u003e\n\u003cul data-start=\"1189\" data-end=\"1345\"\u003e\n\u003cli data-section-id=\"1csi7by\" data-start=\"1189\" data-end=\"1223\"\u003eMicrobiology and virology work\u003c\/li\u003e\n\u003cli data-section-id=\"7iombb\" data-start=\"1224\" data-end=\"1272\"\u003ePharmaceutical compounding (USP \u0026lt;797\u0026gt;\/\u0026lt;800\u0026gt;)\u003c\/li\u003e\n\u003cli data-section-id=\"1etk6ql\" data-start=\"1273\" data-end=\"1301\"\u003eHandling hazardous drugs\u003c\/li\u003e\n\u003cli data-section-id=\"b2wxar\" data-start=\"1302\" data-end=\"1345\"\u003eWork involving volatile toxic chemicals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eType B2 biosafety cabinets are commonly used in microbiology and virology labs, pharmaceutical compounding (USP \u0026lt;797\u0026gt; \/ \u0026lt;800\u0026gt;), toxicology and chemical handling, and research involving hazardous drugs or volatile compounds. The 100% exhaust design makes them especially valuable when chemical vapors must be safely removed from the environment to protect lab personnel.\u003c\/p\u003e\n\u003ch4 data-section-id=\"bchxai\" data-start=\"1592\" data-end=\"1624\"\u003eWhat utilities are required for set up and installation of the Nuaire 430-600?\u003c\/h4\u003e\n\u003cp data-start=\"1625\" data-end=\"1651\"\u003eTypical setup may include:\u003c\/p\u003e\n\u003cul data-start=\"1652\" data-end=\"1744\"\u003e\n\u003cli data-section-id=\"nydaa8\" data-start=\"1652\" data-end=\"1677\"\u003eElectrical connection\u003c\/li\u003e\n\u003cli data-section-id=\"1irbfcu\" data-start=\"1678\" data-end=\"1705\"\u003eExhaust duct connection\u003c\/li\u003e\n\u003cli data-section-id=\"u8hxe8\" data-start=\"1706\" data-end=\"1744\"\u003eOptional gas and plumbing services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1746\" data-end=\"1855\"\u003eThese are necessary for installation per facility and manufacturer specifications.\u003c\/p\u003e\n\u003ch4 data-section-id=\"adnto6\" data-start=\"2512\" data-end=\"2548\"\u003eWhat is the “safe working area” inside this Nuaire BSC?\u003c\/h4\u003e\n\u003cp data-start=\"2549\" data-end=\"2608\"\u003eThe safe working area is the zone inside the cabinet where:\u003c\/p\u003e\n\u003cul data-start=\"2609\" data-end=\"2679\"\u003e\n\u003cli data-section-id=\"1f8tvup\" data-start=\"2609\" data-end=\"2643\"\u003eAirflow is uniform and laminar\u003c\/li\u003e\n\u003cli data-section-id=\"1ydet4d\" data-start=\"2644\" data-end=\"2679\"\u003eContamination risk is minimized\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2681\" data-end=\"2780\"\u003eUsers should perform all work within this defined zone in order to maintain the safe conditions provided by the hood. \u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat does “Class II Type B2” mean?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eA Class II Type B2 biosafety cabinet:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cspan lang=\"FR\" style=\"mso-ansi-language: FR;\"\u003eProvides triple protection (user, sample, environment) \u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo1; tab-stops: list .5in;\"\u003eUses laminar airflow with HEPA filtration \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo1; tab-stops: list .5in;\"\u003eExhausts 100% of air outside the building (no recirculation) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo1; tab-stops: list .5in;\"\u003eIs suitable for toxic chemicals, radionuclides, and biohazards \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eCompared to A2 cabinets, B2 units are ideal when working with volatile chemicals or hazardous drug compounds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eDoes the Nuaire 430-600 require ducting?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eYes. This is a hard-ducted biosafety cabinet that must be connected to an external exhaust system. Because it exhausts 100% of air outside, proper HVAC integration is critical for safe operation, certification compliance, and maintaining airflow balance. Please note that this unit cannot be repurposed as an A2 model to operate without ducting – built in safety features will not allow the fan motor to operate without duct connection. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat is included when purchasing a refurbished unit?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eRefurbished Nuaire 430-600 cabinets from American Instrument Exchange typically include:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003eNew or tested HEPA filters \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003eFull mechanical and electrical inspection \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003eCleaning and decontamination \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003ePerformance testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003ePower cord, stand, and accessories (when applicable)\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eHow are used biosafety cabinets tested and certified?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eEach unit undergoes a multi-step refurbishment and testing process, including:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eHEPA filter integrity \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eAirflow velocity and balance verification \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eSmoke pattern testing for containment \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eElectrical and alarm system checks \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eFinal performance validation \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis ensures the cabinet operates to manufacturer specifications and safety standards. Because B2 units must be connected to ducting our testing procedures differ from the typical standards we use for A2 models. Please \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/contact-us\"\u003econtact our sales team\u003c\/a\u003e for more information. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhy choose a refurbished Nuaire 430-600 over a new unit?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003ePurchasing a \u003ca href=\"https:\/\/www.americaninstrument.com\/pages\/refurbished-biological-safety-cabinets?srsltid=AfmBOopZ8ymu22TRD8VPU4DZF17B8EpwqMWNa_wn_vf-Jj-U6S2MvDYI\"\u003erefurbished unit\u003c\/a\u003e offers:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo4; tab-stops: list .5in;\"\u003eSignificant cost savings vs. new equipment \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo4; tab-stops: list .5in;\"\u003eProven performance after testing and certification \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo4; tab-stops: list .5in;\"\u003eFaster availability compared to factory lead times \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo4; tab-stops: list .5in;\"\u003eSustainability through equipment reuse \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eRefurbished cabinets from reputable vendors provide lab-ready performance at a fraction of the cost.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat should I consider before purchasing this cabinet?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eBefore buying, ensure:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo5; tab-stops: list .5in;\"\u003eYour facility can support external ducting requirements \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo5; tab-stops: list .5in;\"\u003eYou have access to certification services upon installation \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo5; tab-stops: list .5in;\"\u003eThe cabinet meets your application needs (especially chemical use) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eFor B2 cabinets, coordination with your facility engineer and certifier is strongly recommended.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eCan I request a quote or check availability?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eYes. Even if the unit is out of stock, American Instrument Exchange can:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo6; tab-stops: list .5in;\"\u003eSource comparable models \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo6; tab-stops: list .5in;\"\u003e\n\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003eRecommend alternatives\u003c\/a\u003e \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo6; tab-stops: list .5in;\"\u003eProvide refurbished units with similar specs\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$5900.00","offer_id":28870490325040,"sku":"0875I BIO CAB","price":5900.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0875I_BIO_CAB.jpg?v=1560353630"},{"product_id":"nuaire-430-400-cl-b2-hood-4-0875bb-bio-cab","title":"Nuaire 430-400 CL B2 hood, 4'","description":"\u003ch2 class=\"MsoNormal\"\u003eNuaire NU430-400 4' B2 Biological Safety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire NU430-400 4' B2 biological safety cabinet is a total exhaust cabinet. Class II Type B2 biological safety cabinets provide product, operator and environmental protection and are suitable for work with trace amounts of toxic chemicals and agents assigned to biological safety levels I, II or III.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn a Class II Type B2 cabinet, all inflow and downflow air is exhausted after HEPA\/ULPA filtration to the external environment without recirculation across the work surface. They require being connected to HVAC ducting to expel the exhaust on the outside of the building.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU430-400 – Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type B2 total exhaust bio safety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e4’ wide model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eMicroprocessor controller\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStand included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eNuaire NU430-400 – Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eWidely used in toxicology laboratories and other applications in which chemical effluent is present and clean air is essential, the Nuaire NU430-400 recirculates 0% air, as the exhausted air is pulled through a dedicated exhaust duct into the facility exhaust system. In other words, hard ducted to outside the facility, similar to a chemical fume hood.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe entire cabinet shell and all internal plenums and structures on the Nuaire NU430-400 are constructed from Type 304 stainless steel for increased chemical resistance to acids\/solvents which are normally used in applications which require a fume hood.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTesting\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Nuaire NU430-400 biosafety cabinet is fully reconditioned and ready for use. Our technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlthough we conduct thorough testing, our procedures for B2 biosafety cabinets are limited since we cannot replicate hard-ducted conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTo ensure compatibility with your facility and application requirements, we strongly recommend consulting both the manufacturer and your certifier. This step helps confirm that this B2 total exhaust biosafety cabinet is the ideal solution for your needs.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Nuaire NU430-400 4' B2 Biological Safety Cabinet, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$4900.00","offer_id":28870647054384,"sku":"0875BB BIO CAB","price":4900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/no-photo_de67cece-b885-4028-9c17-6bafff2f5ba8.png?v=1560354372"},{"product_id":"4-esco-labculture-class-ii-b2-0873a-bio-cab","title":"4' Esco Labculture Class II B2","description":"\u003cp\u003e\u003cstrong\u003eEsco Labculture Class II, Type B2 4' biosafety cabinet\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4’ wide model\u003c\/li\u003e\n\u003cli\u003eTotal exhaust model (requires ducting)\u003c\/li\u003e\n\u003cli\u003eIncludes stand Includes new HEPA filters\u003c\/li\u003e\n\u003cli\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Esco Labculture total exhaust biosafety cabinet features low energy consumption and heat output resulting in lower total cost of ownership over the lifespan of the BSC. The angled front, narrow profile front grille, raised armrest and frameless sash create an ergonomic work environment while the single piece stainless steel internal work zone eliminates welded joints where contaminants may accumulate.\u003c\/p\u003e\n\u003cp\u003eUnless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment. Our testing procedures for B2 biosafety cabinets are limited, as we cannot replicate the same conditions as being hard ducted to the outside. We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable width=\"80%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal dimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.0\"W x 33.5\"D x 60.6\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal dimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.0\"W x 24.5\" D x 26.4\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow Velocity (Inflow):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 fpm (0.53 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow Velocity (Downflow):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 fpm (0.35 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical requirements:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115VAC , 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eClick here to download the  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/LA2LR2LB2-Combined-Brochure.pdf?2634\" title=\"Esco Labculture Brochure\" target=\"_blank\"\u003eEsco Labculture brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eMedia\u003c\/h5\u003e\n\u003cbr\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/n0DvUi8qSxY\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e \u003cbr\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=n0DvUi8qSxY\u0026amp;feature=youtu.be\" target=\"_blank\"\u003eClick here\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e to see a video of this biosafety cabinet on our YouTube channel.  \u003c\/p\u003e\n\u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e","brand":"MISC","offers":[{"title":"$5900.00","offer_id":29202068963376,"sku":"0873A BIO CAB","price":5900.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/DSC_0527.JPG?v=1583531738"},{"product_id":"esco-airstream-type-b2-biosafety-cabinet-0873aa-bio-cab","title":"Esco Airstream AB2-4S2","description":"\u003ch2 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Biosafety Cabinet – Refurbished\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Esco Airstream Class II Type B2 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment performance. Commonly used for pharmaceutical research, hazardous drug handling, toxicology applications, microbiology workflows, and biotechnology procedures involving volatile toxic chemicals or trace chemical vapors, this refurbished Esco biosafety cabinet offers advanced containment performance for laboratories requiring a ducted Class II Type B2 configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Esco Airstream series has been widely used throughout pharmaceutical facilities, biotechnology laboratories, hospital research environments, toxicology laboratories, and academic research institutions because of its energy-efficient airflow design, ergonomic operating platform, stable containment performance, and modern microprocessor control systems. Esco biosafety cabinets are recognized throughout the laboratory industry for combining operator comfort, low-noise operation, and advanced airflow monitoring technology with high-level containment protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAt \u003ca href=\"https:\/\/www.americaninstrument.com\/\"\u003eAmerican Instrument Exchange\u003c\/a\u003e, each animal transfer station is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories and vivarium facilities outfitting containment-focused workflows may also browse additional refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003elaboratory incubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003efreezers\u003c\/a\u003e available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Key Features\u003c\/h3\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eEsco Airstream Class II Type B2 biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eModel AB2-4S2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e4-foot workspace configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e100% total exhaust airflow design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for hard-ducted exhaust operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for trace chemical and toxicology applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHEPA \/ ULPA-filtered airflow system\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eErgonomic angled front design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eStainless steel work surface\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eMicroprocessor airflow control system\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNegative pressure side-wall design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes stand and new HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e90-day warranty included from American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefurbished and tested by American Instrument Exchange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Overview\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Esco Airstream Class II Type B2 biosafety cabinet is a 4-foot ducted containment cabinet engineered for laboratory environments requiring contamination control, sterile airflow, operator protection, and total exhaust containment capability. Unlike recirculating Type A2 biosafety cabinets, the Airstream Type B2 cabinet exhausts 100% of cabinet airflow through a dedicated facility exhaust system without recirculation inside the work area.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis airflow configuration may make the cabinet especially appropriate for laboratory procedures involving volatile toxic chemicals, hazardous vapors, pharmaceutical compounding, toxicology workflows, radionuclides, microbiology procedures, and biotechnology applications requiring maximum exhaust containment performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEsco designed the Airstream platform to combine high-level containment performance with ergonomic operation and energy-efficient airflow management. Many Airstream cabinets incorporate angled front fascia panels, ergonomic armrests, low-noise blower systems, and advanced microprocessor airflow controls intended to improve operator comfort during extended laboratory procedures.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe cabinet operates using HEPA- or ULPA-filtered airflow designed to maintain ISO Class 5 working conditions while supporting containment protection for biological workflows. Depending on the exact model configuration, features may include stainless steel side walls, removable work trays, fluorescent or LED lighting, airflow alarms, digital displays, side capture zones, and negative-pressure plenums.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe compact 4-foot footprint may make this biosafety cabinet especially appropriate for laboratories requiring total exhaust containment capability while conserving valuable laboratory floor space.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eLaboratories outfitting complete containment workflows may also be interested in refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/co2-incubators\"\u003eCO2 incubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/ultra-low-freezers\"\u003eultra-low freezers\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/autoclaves-sterilizers\"\u003eautoclaves\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/water-baths-and-circulators\"\u003ewater baths\u003c\/a\u003e available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Common Applications\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Esco Airstream Class II Type B2 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, contamination control, and total exhaust operation. Typical applications may include hazardous drug handling, toxicology workflows, microbiology procedures involving volatile toxic chemicals, pharmaceutical preparation, biotechnology research, biological sample handling, and radionuclide applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may also be appropriate for pharmaceutical production facilities, toxicology laboratories, biotechnology laboratories, hospital pharmacies, clinical testing laboratories, academic research facilities, and cleanroom environments requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Ideal Laboratory Environments\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may be suitable for pharmaceutical production facilities, toxicology laboratories, biotechnology laboratories, hospital research environments, academic research facilities, cleanrooms, and containment-focused laboratory applications requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts compact footprint and ergonomic airflow design may make it especially appropriate for laboratories requiring additional chemical containment capability while maximizing available laboratory workspace.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Key Specifications\u003c\/h3\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEsco\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirstream Class II Type B2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCabinet Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Width\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e4 ft\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow Design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100% total exhaust\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExhaust Requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHard-ducted facility exhaust connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFiltration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHEPA \/ ULPA supply and exhaust filtration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWork Surface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStainless steel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow Controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMicroprocessor control system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLighting\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFluorescent or LED lighting depending on configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCabinet Construction\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePowder-coated steel with stainless steel interior components\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e115V, 60Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStand and new HEPA filters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e90-day warranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCondition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefurbished\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003eSpecifications compiled from Esco manufacturer literature, distributor technical references, and American Instrument Exchange product information.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Refurbishment and Testing\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange has extensive experience refurbishing used biosafety cabinets and laboratory containment equipment for research and pharmaceutical environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach biosafety cabinet is inspected by our technicians to verify proper blower operation, airflow performance, sash operation, control operation, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTesting procedures include major functional and airflow verification elements associated with biosafety cabinet performance to help support certification readiness upon installation at your facility. Because this is a ducted Class II Type B2 biosafety cabinet, final certification should be completed after exhaust connection and installation by qualified field technicians in accordance with laboratory requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Certification Readiness\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2 biosafety cabinets should be certified by qualified field technicians after installation and exhaust connection before laboratory use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, exhaust requirements, airflow requirements, electrical requirements, and certification standards prior to installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification services are available throughout New England through \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification requirements may vary depending on laboratory protocols, toxicology workflows, facility standards, and application requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Shipping and Installation Considerations\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, exhaust compatibility, electrical compatibility, and final cabinet placement before shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause this is a ducted Class II Type B2 biosafety cabinet, installation should be coordinated with facility engineering personnel or qualified biosafety cabinet service providers to confirm proper exhaust integration and airflow performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDepending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eEsco Airstream Class II Type B2 Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat makes the Esco Airstream series popular in modern laboratories?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eMany laboratories choose Esco Airstream cabinets because they combine ergonomic operation, modern airflow monitoring systems, energy-efficient blower technology, and low-noise performance with strong containment capability.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat is the difference between a Type B2 cabinet and a standard Type A2 cabinet?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA Class II Type B2 cabinet exhausts 100% of cabinet airflow through a dedicated facility exhaust system without recirculation inside the work area. Standard Type A2 cabinets recirculate a large percentage of airflow internally.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhy would a laboratory choose a Type B2 biosafety cabinet?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eType B2 cabinets are commonly selected for workflows involving volatile toxic chemicals, hazardous vapors, radionuclides, or pharmaceutical compounds that require total exhaust containment performance.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the Esco Airstream Type B2 require a dedicated exhaust connection?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. The cabinet must be connected to an appropriate hard-ducted facility exhaust system before operation and certification.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes American Instrument Exchange replace HEPA filters before shipment?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Unless otherwise specified, American Instrument Exchange installs new HEPA filters before shipment. Cabinets are inspected and tested by our technicians prior to delivery to help support certification readiness after installation.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat testing does American Instrument Exchange perform during refurbishment?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange technicians inspect airflow systems, blower operation, sash functionality, cabinet controls, lighting systems, and overall cabinet condition prior to shipment.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eCan American Instrument Exchange help coordinate biosafety cabinet certification?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e provides biosafety cabinet certification, preventative maintenance, repair, testing, and field service support throughout New England for many biosafety cabinet platforms.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the cabinet include a warranty?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. A 90-day warranty from American Instrument Exchange is included.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/youtu.be\/fuNFawYQyPI\" rel=\"noopener\" target=\"_blank\"\u003eClick here\u003c\/a\u003e to see a video of the Esco Airstream on our YouTube channel. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/fuNFawYQyPI\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"MISC","offers":[{"title":"$5900.00","offer_id":32334235697200,"sku":"0873AA BIO CAB","price":5900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0873AA-4.jpg?v=1597845089"},{"product_id":"forma-1148-class-ii-b2-hood-0870c-bio-cab","title":"Thermo Scientific 1361 B2 Total Exhaust Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1361 6’ B2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 6' Thermo Scientific 1361 B2 biosafety cabinet is designed for microbiological applications involving small amounts of volatile chemicals. It offers an ergonomic design, advanced DC motor technology, and an innovative airflow system for maximum operator safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II, Type B2 cabinets rely entirely on external exhaust methods, as they lack internal exhaust fans. Compared to the 1300 Series A2 cabinet with a thimble connection, the 1300 Series B2 exhausts more air and incurs higher operating costs.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1361 6’ Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type B2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eTotal exhaust unit (must be connected to external vent)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e6’ Wide\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIncludes stand \u0026amp; UV light\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"link to YouTube\" href=\"https:\/\/youtu.be\/ZqBoi97xyiM\"\u003e\u003cem\u003eCLICK HERE\u003c\/em\u003e\u003c\/a\u003e to see the Thermo 1361 6' biosafety cabinet on our YouTube channel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/ZqBoi97xyiM?si=ZCg2UvekoN31EiGM\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1361 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eCompared to an A2 cabinet, the B2 BSC offers enhanced user protection when handling vapors and gases under aseptic conditions. This cabinet provides superior dilution of volatile chemicals within the work area and prevents even diluted recirculation of these chemicals.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBoth thimble-connected A2 and B2 BSCs meet USP \u0026lt;800\u0026gt; guidelines for preparing sterile hazardous and non-hazardous drugs in Class II biological safety cabinets. USP \u0026lt;800\u0026gt; specifies that B2 BSCs are typically used with volatile components, emphasizing their specialized design.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRoom air is drawn through the cabinet’s top and HEPA-filtered before entering the work area. Additional air is drawn into the inlet grille, with all contaminated air routed under the work surface. It then moves up the rear plenum, passing through the exhaust HEPA filter. Finally, a remote blower and exhaust system expel 100% of the filtered air from the lab.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1361 6’ Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" target=\"_blank\" rel=\"noopener\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOur testing procedures for B2 biosafety cabinets are limited, as we cannot replicate the same conditions as being hard ducted to the outside. We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1361 – Additional Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions (not including exhaust)\u003c\/td\u003e\n\u003ctd\u003e78\"W x 32\"D x 62\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorkspace dimensions\u003c\/td\u003e\n\u003ctd\u003e71.25\"W x 18.5\"D x 27.75\"H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking sash height\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1361 6’ Biosafety Cabinet - Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1361 6’ B2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThermo Scientific 1361 Biosafety Cabinet FAQs\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h2\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat is the Thermo Scientific 1361 biosafety cabinet used for?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe Thermo Scientific 1361 is a Class II Type B2 biosafety cabinet designed for microbiological, pharmaceutical, and clinical laboratory applications requiring maximum containment and total exhaust. It is ideal for:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo1; tab-stops: list .5in;\"\u003eWork involving hazardous biological agents (BSL 1–3) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo1; tab-stops: list .5in;\"\u003eProcedures with small amounts of volatile toxic chemicals or gases \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo1; tab-stops: list .5in;\"\u003eSterile drug compounding (USP \u0026lt;800\u0026gt;) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l4 level1 lfo1; tab-stops: list .5in;\"\u003eCell culture, virology, and microbiology workflows \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eUnlike recirculating cabinets, this model exhausts 100% of filtered air, making it especially suitable for applications involving chemical vapors. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eWhat makes a Class II Type B2 biosafety cabinet different from A2 models?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe key difference is airflow and exhaust design:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eType B2 (Thermo 1361): \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"circle\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level2 lfo2; tab-stops: list 1.0in;\"\u003e100% external exhaust (no air recirculation) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level2 lfo2; tab-stops: list 1.0in;\"\u003eRequires connection to a dedicated building exhaust system \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level2 lfo2; tab-stops: list 1.0in;\"\u003eSuperior for handling vapors, gases, and hazardous drugs \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eType A2: \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"circle\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level2 lfo2; tab-stops: list 1.0in;\"\u003eRecirculates ~70% of air \u003cspan style=\"font-family: 'Arial',sans-serif;\"\u003efrom \u003c\/span\u003ethe cabinet back into the lab \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level2 lfo2; tab-stops: list 1.0in;\"\u003eLimited use with volatile chemicals \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eBecause the 1361 prevents recirculation of contaminated air, it offers enhanced personnel and environmental protection in demanding applications. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eHow does airflow work in the Thermo 1361 B2 cabinet?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThe cabinet uses a multi-stage HEPA filtration and airflow system:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eRoom air is drawn into the top of the cabinet \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eAir is HEPA-filtered before entering the work zone \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eContaminated air is pulled through front and rear grilles \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eAir passes through a second HEPA filter \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e100% of air is exhausted outside via ducting \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis system ensures:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eProduct protection (sterility) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003ePersonnel protection (containment) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eEnvironmental protection (no recirculation) \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eCan the Thermo 1361 be used for hazardous drug compounding?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eYes. Class II Type B2 cabinets like the Thermo 1361 are commonly used in USP \u0026lt;800\u0026gt; compliant environments, especially when handling:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo6; tab-stops: list .5in;\"\u003eHazardous drugs \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo6; tab-stops: list .5in;\"\u003eVolatile compounds \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo6; tab-stops: list .5in;\"\u003eChemotherapy preparations \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eIts total exhaust design makes it one of the preferred cabinet types for these applications.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eIs a refurbished Thermo 1361 biosafety cabinet reliable?\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eYes—when purchased from a qualified vendor like American Instrument Exchange.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eEach \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003erefurbished unit\u003c\/a\u003e undergoes:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo5; tab-stops: list .5in;\"\u003eHEPA filter integrity (PAO\/DOP) testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo5; tab-stops: list .5in;\"\u003eAirflow velocity and smoke pattern testing \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo5; tab-stops: list .5in;\"\u003eElectrical and alarm system verification \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo5; tab-stops: list .5in;\"\u003eFull cleaning and decontamination \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l5 level1 lfo5; tab-stops: list .5in;\"\u003ePerformance validation aligned with NSF\/ANSI 49 standards \u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThis ensures the cabinet is ready for certification and safe lab use upon installation.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"8900.00 \/ 03-29-2024","offer_id":41235961020464,"sku":"0870C BIO CAB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0909.jpg?v=1711733714"},{"product_id":"thermo-1510-biosafety-cabinet-0870cc-bio-cab","title":"Thermo Scientific 1510 Type B2 Biosafety Cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1510 4’ B2 Biosafety Cabinet\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Thermo Scientific 1510 4’ B2 biosafety cabinet meets NSF\/ANSI 49 for a Class II, Type B2 BSC. These energy efficient cabinets require direct connection to external exhaust and provide personal and product protection from biological hazards and contamination as well as protection from volatile toxic chemicals used in the cabinet.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1510 4’ Biosafety Cabinet - Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eClass II Type B2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eTotal exhaust unit (must be connected to external vent)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e4’ Wide\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eSmartFlow technology\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eNew HEPA filters included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"560\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/be6rdLoeLVg\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo Scientific 1510 - Features\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet has SmartFlow compensation to maintain downflow allowing effective use of downflow prefilter for extended HEPA filter life. It also has a counterbalanced sash for easy operation, and an 8” sash height, Type 304 stainless-steel interior, LCD information display located within the chamber, and touchpad controls within reach while seated.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1510 4’ Biosafety Cabinet - Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eOur technicians test each biosafety cabinet and clean bench to ensure that the controls and blower motor work properly, as well as ensuring that the HEPA filter is suitable for use in lab conditions. Our testing procedure includes all the elements of certification in order to ensure that the unit will pass certification once it is at your site.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf you're in the Greater Boston or New England area, contact our sister company, \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Lab Services\u003c\/a\u003e, to schedule your certification. In many cases, certification can be completed on the day of or following delivery. Their services include testing, certification, repair, replacement, decontamination, and removal of biosafety cabinets and clean benches. You can reach them at 978-521-2221 or by email at \u003ca href=\"mailto:services@aielaboratoryservices.com\" rel=\"noopener\" target=\"_blank\"\u003eservices@aielaboratoryservices.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOur testing procedures for B2 biosafety cabinets are limited, as we cannot replicate the same conditions as being hard ducted to the outside. We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThermo Scientific 1510 – Additional Specifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e54.3”W x 31.6”D x 71.5”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork area dimensions\u003c\/td\u003e\n\u003ctd\u003e48.5”W x 25.5”D x 25.7-29.2”H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust flow measured with traverse\u003c\/td\u003e\n\u003ctd\u003e852 CFM @ 1.8 inches w.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInflow air volume\u003c\/td\u003e\n\u003ctd\u003e283 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e545 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermo 1510 4’ Biosafety Cabinet - Pictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about the Thermo Scientific 1510 4’ A2 Biosafety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eThermo 1510 B2 Biosafety Cabinet – Frequently Asked Questions\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWhat does “Class II Type B2” mean?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA Class II Type B2 cabinet is a total-exhaust biosafety cabinet, meaning 100% of the air entering the cabinet is exhausted through a dedicated external duct system rather than recirculated. This design makes it suitable for work involving biological agents and small amounts of volatile toxic chemicals or radionuclides.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWhat features are included in the Thermo 1510 biosafety cabinet?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eCommon features of the Thermo Scientific 1500 Series B2 cabinets include:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSmartFlow airflow compensation\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eEnergy-efficient DC motor\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eStainless steel work chamber\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eTouchscreen or graphical display for monitoring airflow and alarms\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHEPA filtration for contamination control\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0in; line-height: normal;\"\u003eThese features help maintain stable airflow and provide visual alerts about cabinet status. \u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow often should a Thermo 1510 biosafety cabinet be certified?\u003co:p\u003e\u003c\/o:p\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets should be certified during installation and typically re-certified annually to verify airflow performance, filter integrity, and containment. This is standard practice in laboratories using biosafety cabinets.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003co:p\u003e \u003c\/o:p\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"$9900.00","offer_id":39553175224368,"sku":"0870CC BIO CAB","price":9900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0870CC-1.jpg?v=1622835544"},{"product_id":"labconco-purifier-logic-0883fff-bio-cab","title":"Labconco Purifier Logic 4’ Class II, Type B2","description":"\u003ch2\u003eLabconco Purifier Logic 4’ Class II Type B2 Biosafety Cabinet – Refurbished\u003c\/h2\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eThe Labconco Purifier Logic 4’ Class II Type B2 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment and contamination-controlled airflow. Commonly used for microbiology, cell culture, pharmaceutical preparation, antineoplastic drug preparation, and biological research workflows, this refurbished Labconco Type B2 biosafety cabinet is appropriate for laboratories requiring a fully exhausted cabinet configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eAt American Instrument Exchange, each biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eKey Features\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"Compact\"\u003eClass II Type B2 biosafety cabinet\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003e4-foot workspace configuration\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003eTotal exhaust design with 100% exhausted air\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003e8-inch sash opening\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003e90-day warranty included from American Instrument Exchange\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003eIncludes new HEPA filters\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003eDesigned for personnel, product, and environmental protection\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003eSuitable for BSL-1, BSL-2, and BSL-3 containment applications when properly installed and certified\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003eAppropriate for antineoplastic drug preparation and workflows requiring total exhaust\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003cli class=\"Compact\"\u003eRefurbished and tested by American Instrument Exchange\u003co:p\u003e\u003c\/o:p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eOverview\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eThe Labconco Purifier Logic 4’ Class II Type B2 biosafety cabinet is a total exhaust biological safety cabinet designed for laboratory environments requiring contamination control, sterile airflow, operator protection, and full exhaust of cabinet air through a properly connected facility exhaust system. Unlike Class II Type A2 biosafety cabinets, which recirculate a portion of filtered air back into the laboratory, Type B2 cabinets exhaust 100% of cabinet air to the outside through a dedicated exhaust connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eThis cabinet configuration is commonly used for laboratory procedures involving hazardous particulates, biological materials, antineoplastic drug preparation, and applications where a total exhaust airflow design is required by laboratory protocols or facility safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eLabconco Purifier Logic cabinets are widely used in biotechnology, pharmaceutical, clinical, hospital, academic, and government research laboratories because of their ergonomic design, airflow control systems, and laboratory-focused containment performance. Features may include stainless steel interior surfaces, angled sash design, airflow monitoring, bright interior lighting, and ergonomic workspace configuration depending on the specific unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eBecause this is a Type B2 biosafety cabinet, buyers should confirm exhaust compatibility, facility ductwork requirements, and certification requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eCommon Applications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eThe Labconco Purifier Logic 4’ Type B2 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, biological containment, and total exhaust operation. Typical applications include microbiology workflows, cell culture procedures, tissue culture applications, biological sample handling, pharmaceutical preparation, antineoplastic drug preparation, and work with agents requiring Biosafety Level 1, 2, or 3 containment when used in an appropriate laboratory setting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eThis cabinet may also be appropriate for laboratories working with materials or procedures where recirculation is not desired and total exhaust through a dedicated building exhaust system is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eIdeal Laboratory Environments\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eThis biosafety cabinet may be suitable for pharmaceutical laboratories, hospital pharmacies, oncology preparation areas, biotechnology laboratories, academic research institutions, clinical laboratories, government research facilities, and cleanroom or containment-focused laboratory environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eIts Type B2 total exhaust configuration makes it especially relevant for facilities that require a fully exhausted biosafety cabinet for certain pharmaceutical, biological, or contamination-sensitive workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eKey Specifications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable class=\"Table\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"border-collapse: collapse; mso-yfti-tbllook: 32; mso-padding-alt: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: -1; mso-yfti-firstrow: yes; mso-yfti-lastfirstrow: yes;\"\u003e\n\u003ctd valign=\"bottom\" style=\"border: none; border-bottom: solid windowtext 1.0pt; mso-border-bottom-alt: solid windowtext .25pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\" style=\"mso-yfti-cnfc: 1;\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"bottom\" style=\"border: none; border-bottom: solid windowtext 1.0pt; mso-border-bottom-alt: solid windowtext .25pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\" style=\"mso-yfti-cnfc: 1;\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eManufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eLabconco\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003ePurifier Logic 0883FFF \/ Catalog No. 3461001\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eCabinet Class\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eClass II Type B2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eNominal Width\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e4 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eExhaust Configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e100% exhausted air \/ total exhaust\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eSash Opening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e8 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eExterior Dimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e54.31” W × 31.21” D × 61.4” H\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eInterior Worksurface Dimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e48.5” W × 17.59” D × 29.2” H\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eElectrical Requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e115V, 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eIncluded Accessories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eNew HEPA filters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eWarranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e90-day warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eCondition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"Compact\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eRefurbished\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eRefurbishment and Testing\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eAmerican Instrument Exchange has extensive experience refurbishing used biosafety cabinets for laboratory and cleanroom environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eEach biosafety cabinet is inspected by our technicians to verify proper blower operation, control functionality, airflow performance, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eTesting procedures include major elements associated with biosafety cabinet certification to help support certification readiness upon installation at your facility. Because this is a Type B2 total exhaust cabinet, final installation should include confirmation of exhaust connection, airflow performance, and certification by qualified field technicians.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cb\u003eCertification Readiness\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eBiosafety cabinets should be certified by qualified field technicians after installation and before laboratory use. This is especially important for Class II Type B2 biosafety cabinets because they must be connected to an appropriate exhaust system and verified for proper inflow, downflow, and exhaust performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eAmerican Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, electrical requirements, exhaust requirements, airflow specifications, and certification standards prior to installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eCertification services are available through our affiliate company, https:\/\/www.aielaboratoryservices.com, which provides biosafety cabinet certification, testing, and field service support.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eCertification requirements may vary depending on laboratory protocols, facility standards, cabinet installation, and application requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cb\u003eShipping and Installation Considerations\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eBiosafety cabinets are oversized laboratory instruments that may require special handling during transportation, delivery, and installation. Buyers should confirm laboratory access dimensions, doorway clearances, electrical compatibility, exhaust ducting requirements, and final cabinet placement before shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eBecause this Labconco Purifier Logic is a Class II Type B2 total exhaust cabinet, installation should be coordinated with facility engineering, safety personnel, or a qualified biosafety cabinet service provider to verify ductwork compatibility and certification requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoBodyText\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eDepending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3\u003eLabconco Purifier Logic 4’ Class II Type B2 \u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eFrequently Asked Questions\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eIs this Labconco Purifier Logic cabinet a Type A2 or Type B2 biosafety cabinet?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: Xe487249775b1f78d722fd9565cefe681bb8c34a;\"\u003eThis unit is a Class II Type B2 biosafety cabinet. Type B2 cabinets are total exhaust cabinets designed to exhaust 100% of cabinet air through an appropriate facility exhaust system.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eWhat does total exhaust mean on a Type B2 biosafety cabinet?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: Xcd3c80218aca3d947ff38ca43e5e2bdfe3588d5;\"\u003eTotal exhaust means that the cabinet exhausts all air from the cabinet rather than recirculating a portion of filtered air back into the laboratory. This configuration requires connection to a properly designed exhaust system.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eWhat size is this Labconco Purifier Logic biosafety cabinet?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: Xa70fa9ffc67f6adc02b6a195b6dbf5dfb79a4df;\"\u003eThis is a 4-foot biosafety cabinet with exterior dimensions of approximately 54.31” W × 31.21” D × 61.4” H and interior dimensions of approximately 48.5” W × 17.59” D × 29.2” H.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eWhat applications is this Type B2 biosafety cabinet commonly used for?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: Xa460200e579e59508b4d9175da39daff1c02d03;\"\u003eTypical applications include microbiology workflows, cell culture procedures, biological sample handling, pharmaceutical preparation, antineoplastic drug preparation, and work requiring BSL-1, BSL-2, or BSL-3 containment in an appropriate laboratory setting.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eDoes this biosafety cabinet include new HEPA filters?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: X727b0c86b99b2e080796c00a5b44f391141e769;\"\u003eYes. Unless otherwise specified, new HEPA filters are installed by American Instrument Exchange technicians prior to shipment.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eDoes this cabinet require external exhaust?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: Xebe04cd5f645abfda591ee949e2e5d887c69c6c;\"\u003eYes. As a Class II Type B2 total exhaust biosafety cabinet, this unit must be connected to an appropriate facility exhaust system and certified after installation.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eDoes this biosafety cabinet include a warranty?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: X82151d63296e7ce4231f558ec61bb9ce42f9d3a;\"\u003eYes. A 90-day warranty from American Instrument Exchange is included.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003eCan the cabinet be certified after installation?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"FirstParagraph\"\u003e\u003cspan style=\"mso-bookmark: X22c7058d04da8ee28832c662a78cf944be8fafa;\"\u003e\u003cspan style=\"mso-bookmark: X591e40c76d2be70d9b90eef054a5f94c0b59eab;\"\u003eThe cabinet is tested prior to shipment to support certification readiness upon installation. Final certification should be completed by qualified field technicians after installation and exhaust connection.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/youtu.be\/3FlCOQ7exgE\" title=\"Link to YouTube\"\u003eCLICK HERE\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003cstrong\u003eto see the Labconco Purifier Logic 3461001 4' B2 total exhaust biosafety cabinet on our YouTube channel\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/3FlCOQ7exgE?si=xGjpIfYBC66NlRsy\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Labconco","offers":[{"title":"Default Title","offer_id":39983481290800,"sku":"0883FFF BIO CAB","price":8900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0883HH-1_99637490-6302-47bc-be22-bd987e5d61fd.jpg?v=1643651511"},{"product_id":"labconco-delta-type-b2-bsc-0883u-bio-cab","title":"Labconco Delta Type B2 BSC","description":"\u003cp\u003e\u003cstrong\u003eLabconco 4’ Delta Purifier Type B2 Total Exhaust Biological Safety Cabinet\u003c\/strong\u003e\u003c\/p\u003e\n \n \u003cul\u003e\n \u003cli\u003eCat. No. 3621004\u003c\/li\u003e\n \u003cli\u003eRequires ducted connection to HVAC system\u003c\/li\u003e\n \u003cli\u003eNew HEPA filters included\u003c\/li\u003e\n \u003cli\u003e90-day warranty\u003c\/li\u003e\n \u003c\/ul\u003e\n \n \u003cp\u003eEvery component of the Labconco Purifier Delta Series Class II B2 Biosafety Cabinet has been optimized for peak performance. The Air-Wave Entry System, consisting of the curved design of the side posts, air foil and sash handle, ensures smoother airflow into the work area minimizing turbulence and enhancing containment. Internally, we’ve designed a ramped steel plenum that captures the recirculated air, stabilizes it, and then distributes it evenly across the HEPA filters and the work area. Laminar airflow is idealized and true, not zoned. The Air-Wave Entry System and plenum work together to provide superior airflow that protects the operator and prevents cross contamination.\u003c\/p\u003e\n \n \u003cp\u003eThe exclusive Contain-Air Negative Pressure Channel, located behind the sash, maximizes containment at the air gap between the top of the sash opening and the cabinet wall. Any hazardous aerosol created in the work area that may travel upward toward the top of the sash is drawn into the channel by negative pressure and then forced through a HEPA filter. Unreliable seals and gaskets, which could degrade or drag on the contaminated glass, are not used.\u003c\/p\u003e\n \n \u003cp\u003eUnless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment. Our testing procedures for B2 biosafety cabinets are limited, as we cannot replicate the same conditions as being hard ducted to the outside. We recommend that you contact the manufacturer and certifier (or whoever will be overseeing the installation) to ensure that this B2 total exhaust biosafety cabinet is right for your application, and compatible with your facility.\u003c\/p\u003e\n \n \u003cp\u003eThe photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.\u003c\/p\u003e\n \n \u003cp\u003e\u003cstrong\u003eLabconco 4’ Delta Purifier Type B2 Total Exhaust Biological Safety Cabinet\u003c\/strong\u003e \u003cstrong\u003e– Specifications\u003c\/strong\u003e\u003c\/p\u003e\n \n \u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"padding:10px;\"\u003eDimensions\u003c\/td\u003e\n \u003ctd style=\"padding:10px;\"\u003e54”W x 31.75”D x 65”H\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"padding:10px;\"\u003eWork area dimensions\u003c\/td\u003e\n \u003ctd style=\"padding:10px;\"\u003e47”W x 18”D x 26.5H\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"padding:10px;\"\u003eSash height\u003c\/td\u003e\n \u003ctd style=\"padding:10px;\"\u003e8”\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"padding:10px;\"\u003eExhaust volume\u003c\/td\u003e\n \u003ctd style=\"padding:10px;\"\u003e743 to 771 CFM\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"padding:10px;\"\u003eWeight\u003c\/td\u003e\n \u003ctd style=\"padding:10px;\"\u003e736 lbs\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"padding:10px;\"\u003eElectrical requirements\u003c\/td\u003e\n \u003ctd style=\"padding:10px;\"\u003e115V, 60Hz\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \n \u003cp\u003e \u003c\/p\u003e\n \n \u003cp\u003eFor inquiries about the Labconco 4’ Delta Purifier Type B2 Total Exhaust Biological Safety Cabinet, please give us a call at 978-521-2221, or fill out the form on this page.\u003c\/p\u003e","brand":"Labconco","offers":[{"title":"$5900.00","offer_id":40234305224752,"sku":"0883U BIO CAB","price":5900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/no-photo_b80c1195-e1ff-4d27-9c9f-d79b98d365df.png?v=1653072980"},{"product_id":"nuaire-nu430-400-4-b2-biosafety-cabinet-0875dd-bio-cab","title":"Nuaire LabGard NU-430-400 biosafety cabinet","description":"\u003ch2 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Class II Type B2 Biosafety Cabinet – Refurbished\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-430-400 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment performance. Commonly used for pharmaceutical research, hazardous drug handling, microbiology workflows, biotechnology applications, and laboratory procedures involving volatile toxic chemicals or radionuclides, this refurbished Nuaire biosafety cabinet offers advanced containment performance for laboratories requiring a Class II Type B2 configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAt \u003ca href=\"https:\/\/www.americaninstrument.com\/\"\u003eAmerican Instrument Exchange\u003c\/a\u003e, each biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories outfitting high-containment workflows may also browse additional refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/autoclaves-sterilizers\"\u003eautoclaves\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003elaboratory freezers\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\/CO2\"\u003eCO2 incubators\u003c\/a\u003e available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Key Features\u003c\/h3\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eClass II Type B2 biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e4-foot workspace configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e100% total exhaust airflow design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for hard-ducted exhaust operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for volatile toxic chemical applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNSF\/ANSI 49 compliant design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHEPEX™ zero-leak airflow construction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes stand and new HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e90-day warranty included from American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefurbished and tested by American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for personnel, product, and environmental protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for hazardous drug handling and pharmaceutical workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Overview\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-430-400 is a 4-foot Class II Type B2 biosafety cabinet engineered for laboratory environments requiring contamination control, sterile airflow, operator protection, and total exhaust containment capability. Unlike recirculating Type A2 biosafety cabinets, the NU-430 series is designed for hard-ducted operation and exhausts 100% of cabinet airflow through a dedicated facility exhaust system without recirculation inside the cabinet workspace.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis configuration may make the NU-430-400 appropriate for laboratory procedures involving volatile toxic chemicals, hazardous drug preparation, radionuclides, pharmaceutical compounding, microbiology workflows, and contamination-sensitive research applications requiring maximum exhaust containment performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe NU-430 series is commonly used throughout biotechnology laboratories, pharmaceutical facilities, hospital research environments, cleanrooms, academic research institutions, and government laboratories because of its total exhaust airflow configuration and high-containment capability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFeatures may include HEPEX™ airflow construction, stainless steel work surfaces, airflow monitoring systems, ergonomic sash positioning, fluorescent lighting, removable work trays, and heavy-duty cabinet construction depending on the specific configuration of the unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe compact 4-foot footprint may make this biosafety cabinet especially appropriate for laboratories requiring total exhaust containment capability while conserving valuable laboratory floor space.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eLaboratories outfitting complete containment workflows may also be interested in refurbished \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\/-80\"\u003eultra-low temperature freezers\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003eincubators\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/baths\"\u003elaboratory water baths\u003c\/a\u003e from American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Common Applications\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-430-400 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, contamination control, and total exhaust operation. Typical applications include hazardous drug handling, pharmaceutical preparation, microbiology workflows, tissue culture procedures, biotechnology research, biological sample handling, and laboratory procedures involving volatile toxic chemicals or radionuclides.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may also be appropriate for pharmaceutical production facilities, hospital pharmacies, biotechnology laboratories, clinical testing laboratories, academic research facilities, government research institutions, and cleanroom environments requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Ideal Laboratory Environments\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may be suitable for pharmaceutical production facilities, biotechnology laboratories, hospital research environments, academic research facilities, cleanrooms, government laboratories, and containment-focused laboratory applications requiring a ducted Class II Type B2 biosafety cabinet.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts total exhaust airflow configuration may make it especially appropriate for laboratories requiring additional chemical containment capability beyond standard recirculating biosafety cabinet systems.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Key Specifications\u003c\/h3\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNuaire\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLabGard NU-430-400\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCabinet Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Width\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e4 ft\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow Design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100% total exhaust\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExhaust Requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHard-ducted facility exhaust connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExterior Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 53–54” W × 32–33” D × 61–63” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInterior Work Area Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 46” W × 23.5” D × 28.5” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSash Opening\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e10 in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFiltration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHEPA supply and exhaust filtration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e115V, 60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStand and new HEPA filters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e90-day warranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCondition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefurbished\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Refurbishment and Testing\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange has extensive experience refurbishing used biosafety cabinets and laboratory containment equipment for research and pharmaceutical environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach biosafety cabinet is inspected by our technicians to verify proper blower operation, airflow performance, sash operation, control operation, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTesting procedures include major functional and airflow verification elements associated with biosafety cabinet performance to help support certification readiness upon installation at your facility. Because this is a ducted Class II Type B2 biosafety cabinet, final certification should be completed after exhaust connection and installation by qualified field technicians in accordance with laboratory requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Certification Readiness\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type B2 biosafety cabinets should be certified by qualified field technicians after installation and exhaust connection before laboratory use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, exhaust requirements, airflow requirements, electrical requirements, and certification standards prior to installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification services are available throughout New England through \u003ca href=\"https:\/\/www.aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification requirements may vary depending on laboratory protocols, facility standards, and application requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Shipping and Installation Considerations\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, exhaust compatibility, electrical compatibility, and final cabinet placement before shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause this is a ducted Class II Type B2 biosafety cabinet, installation should be coordinated with facility engineering personnel or qualified biosafety cabinet service providers to confirm proper exhaust integration and airflow performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDepending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-430-400 Frequently Asked Questions\u003c\/h3\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhat is the difference between a Type A2 and Type B2 biosafety cabinet?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eA Type B2 biosafety cabinet exhausts 100% of cabinet airflow through a dedicated facility exhaust system without internal recirculation. Type A2 cabinets recirculate a large percentage of filtered air back into the workspace.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhy would a laboratory choose the NU-430-400 instead of a larger B2 cabinet?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe NU-430-400 provides total exhaust containment capability in a more compact 4-foot footprint. Many laboratories prefer smaller B2 cabinets when laboratory space is limited or when workflows do not require a larger 5-foot or 6-foot workspace.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eDoes the NU-430-400 require a dedicated exhaust system?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. The NU-430-400 is a hard-ducted Class II Type B2 biosafety cabinet and must be connected to an appropriate facility exhaust system before operation and certification.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhat applications commonly require a Type B2 biosafety cabinet?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eType B2 biosafety cabinets are commonly used for hazardous drug preparation, pharmaceutical compounding, microbiology workflows involving volatile toxic chemicals, radionuclide applications, and laboratory procedures requiring maximum exhaust containment.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eHow does American Instrument Exchange prepare refurbished Type B2 biosafety cabinets?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange technicians inspect blower systems, airflow performance, cabinet controls, sash operation, lighting systems, and overall cabinet condition prior to shipment. Unless otherwise specified, new HEPA filters are installed before delivery.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eCan American Instrument Exchange help coordinate certification after installation?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Certification services are available through AIE Laboratory Services, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eDoes the cabinet include a warranty?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. A 90-day warranty from American Instrument Exchange is included.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eDoes a ducted Type B2 cabinet require special installation planning?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Buyers should confirm exhaust compatibility, airflow requirements, electrical compatibility, doorway clearances, and final cabinet placement prior to shipment and installation.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e \u003ca title=\"Link to YouTube\" href=\"https:\/\/youtu.be\/KZWERYoVRgA\"\u003e\u003cem\u003eCLICK HERE \u003c\/em\u003e\u003c\/a\u003eto see the Nuaire NU-430-400 4' B2 total exhaust biosafety cabinet on our YouTube channel\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/KZWERYoVRgA?si=9bagmTN8F2kyjXnd\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"Default Title","offer_id":40692857602096,"sku":"0875DD BIO CAB","price":9900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0942.jpg?v=1724780047"}],"url":"https:\/\/www.americaninstrument.com\/collections\/class-ii-type-b2-biosafety-cabinets.oembed","provider":"American Instrument Exchange","version":"1.0","type":"link"}