Panasonic KM-CC17RU1A CO2 cell culture incubator

  • 6.0 cubic foot chamber (170L)
  • Temperature range: ambient +5°C to 50°C
  • Dual process decontamination routine for extremely effective sterilization
  • H2O2 application eliminates the need for autoclaving, reducing downtime
  • Advanced digital display with multi point data logging
  • 90 day warranty

The Panasonic KM-CC17RU1A CO2 incubator is the right choice for especially sensitive cell cultures by providing two decontamination processes in a single unit. The automatic decontamination process begins with a vaporized H2O2 application followed by UV exposure. The H2O2 application ensures complete decontamination of all interior components and CO2 sampling loop. The UV exposure adds redundant decontamination and reduces the H2O2 to water vapor and oxygen eliminating any user health hazards from the vapor application. This process provides complete sterilization in less than three hours and eliminates the need for autoclaving, minimizing downtime between product cycles. Opening the front access door starts a UV exposure cycle maintaining sterilization within the incubating compartment. The stainless steel interior is copper enriched for even more sterilization redundancy.

Heat application is precisely controlled using three independent heating zones with microprocessor PID control. Operating temperatures are maintained between +5°C above ambient to +50°C with a temperature uniformity of +/- 0.25°C at 37°C. Humidity is maintained at 95% at 37°C using natural evaporation and a water pan. CO2 can be maintained between 0% and 20%, accurate to 0.1%, with a maximum deviation of +/- 0.15% at 37°C and 5% CO2 setting and no load. Volume of the incubating chamber is 6 cubic feet and the unit is stackable.

All of our equipment is used and reconditioned. Our technicians test incubators using a calibrated digital chart recorder to verify the accuracy of temperature controls and readouts. We replace any hardware or parts as is necessary and clean all incubators thoroughly prior to shipment.