{"product_id":"air-science-purair-basic-p5-36xt-ductless-fume-hood","title":"Air Science Purair BASIC P5-36XT Ductless Fume Hood","description":"\u003ch2\u003eAir Science Purair BASIC P5-36XT Ductless Fume Hood (Filters Not Included)\u003c\/h2\u003e\n\u003cp\u003eThe Air Science Purair BASIC P5-36XT Ductless Fume Hood is a compact laboratory containment enclosure designed to help protect personnel from chemical vapors when equipped with the appropriate filtration media. Featuring a \u003cstrong\u003e36-inch-wide workspace\u003c\/strong\u003e, epoxy-coated steel construction, energy-efficient EC blower, clear acrylic side panels, and an extra-tall working opening, the P5-36XT provides an excellent workstation for laboratories performing light chemical handling, sample preparation, weighing, and analytical procedures. This refurbished Air Science P5-36XT from American Instrument Exchange offers a cost-effective alternative to new equipment while delivering the quality and construction expected from the Purair BASIC series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e \u003cstrong\u003eThis unit is sold without filtration media. No carbon, HEPA, ULPA, or specialty filters are included.\u003c\/strong\u003e Appropriate filters must be selected and installed based on the specific chemicals and applications before the hood is placed into service.\u003c\/p\u003e\n\u003ch3\u003eAir Science Purair BASIC P5-36XT Ductless Fume Hood Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAir Science Purair BASIC P5-36XT ductless fume hood\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilters not included\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e36-inch work area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtra-tall cabinet configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEpoxy-coated steel construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClear acrylic side panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpflow airflow design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy-efficient EC centrifugal blower\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual fan controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-profile design for laboratory benchtops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with activated carbon, HEPA, ULPA, and specialty filters (sold separately)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefurbished and tested by American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90-day warranty included from American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAir Science Purair BASIC P5-36XT Ductless Fume Hood Overview\u003c\/h3\u003e\n\u003cp\u003eThe Purair BASIC P5-36XT is designed for laboratories requiring localized containment without the expense or infrastructure associated with ducted exhaust systems. Rather than exhausting conditioned laboratory air outdoors, the hood recirculates air through application-specific filtration media before returning it to the laboratory. The extra-tall work opening provides additional clearance for taller laboratory apparatus while maintaining a compact overall footprint suitable for crowded laboratory environments.\u003c\/p\u003e\n\u003cp\u003eBecause filtration requirements vary significantly depending on the chemicals being used, this refurbished unit is supplied \u003cstrong\u003ewithout filters\u003c\/strong\u003e, allowing the purchaser to install new filtration media specifically selected for their intended application. Activated carbon filters, HEPA filters, ULPA filters, and specialty chemical filters are available for different laboratory processes and should always be selected based on a documented chemical compatibility review.\u003c\/p\u003e\n\u003ch3\u003eAir Science Purair BASIC P5-36XT Ductless Fume Hood Key Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAir Science\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePurair BASIC P5-36XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eDuctless Filtered Fume Hood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Width\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36 in. (914 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Depth\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 in. (676 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Height\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e35 in. (889 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Height\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23.6 in. (600 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eEpoxy-Coated Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Panels\u003c\/td\u003e\n\u003ctd\u003eClear Acrylic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd\u003eUpflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eEnergy-Efficient EC Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003eManual Fan On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e120 VAC, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Compatibility\u003c\/td\u003e\n\u003ctd\u003eActivated Carbon, HEPA, ULPA, Specialty Filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilters Included\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e99 lb (45 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Efficiency \u0026amp; Operating Costs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Purair BASIC series utilizes an electronically commutated (EC) blower designed for quiet operation and reduced energy consumption compared to conventional AC motors. Because this listing does \u003cstrong\u003enot include filters\u003c\/strong\u003e, buyers can install new filtration media matched to their specific application rather than replacing unknown used filters. Routine filter monitoring and replacement are essential for maintaining safe performance and should always follow the filter manufacturer's recommendations and the laboratory's chemical hygiene plan.\u003c\/p\u003e\n\u003cp\u003eSpecifications compiled from Air Science manufacturer literature and American Instrument Exchange product information.\u003c\/p\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cp\u003eWhen equipped with the appropriate filtration media, the Air Science P5-36XT is commonly used for chemical weighing, reagent preparation, analytical chemistry, pharmaceutical compounding, educational laboratories, quality control testing, forensic laboratories, sample preparation, and other laboratory procedures involving small quantities of compatible chemicals. The hood should only be used with chemicals approved for the installed filter type.\u003c\/p\u003e\n\u003ch3\u003eIdeal Laboratory Types\u003c\/h3\u003e\n\u003cp\u003eThis ductless fume hood is well suited for analytical laboratories, pharmaceutical manufacturers, biotechnology companies, university teaching laboratories, environmental testing laboratories, quality control departments, forensic laboratories, industrial research facilities, and general laboratory environments where localized chemical containment is required. Laboratories utilizing analytical balances, laboratory water purification systems, hot plates, stirrers, microscopes, and spectrophotometers frequently incorporate ductless hoods into their workflows.\u003c\/p\u003e\n\u003ch3\u003eContainment Performance \u0026amp; Filter Selection\u003c\/h3\u003e\n\u003cp\u003eUnlike conventional ducted fume hoods, the Purair BASIC P5-36XT depends entirely on properly selected filtration media to remove contaminants before air is recirculated into the laboratory. Air Science offers activated carbon filters for chemical vapors as well as HEPA and ULPA filters for particulate applications. Some applications require combinations of filters or specialty media designed for specific chemical families. Because filter selection depends on chemical identity, concentration, exposure limits, and anticipated usage, laboratories should evaluate their applications before installing the appropriate filters.\u003c\/p\u003e\n\u003ch3\u003eRecommended Laboratory Applications\u003c\/h3\u003e\n\u003cp\u003eThis hood is intended for laboratory procedures involving chemicals compatible with the installed filtration media. It is not a universal chemical fume hood, and laboratories should verify that the selected filters are appropriate for their specific solvents, acids, bases, aldehydes, particulates, or other airborne contaminants before operation.\u003c\/p\u003e\n\u003ch3\u003eRefurbishment and Testing Process\u003c\/h3\u003e\n\u003cp\u003eAt American Instrument Exchange, each refurbished ductless fume hood is inspected and evaluated by our technicians prior to shipment. Testing procedures may include verification of blower operation, lighting (if equipped), controls, cabinet integrity, sash operation, electrical safety, and overall mechanical condition. Because this unit is sold \u003cstrong\u003ewithout filters\u003c\/strong\u003e, filtration performance is not represented until new application-specific filters are installed by the purchaser.\u003c\/p\u003e\n\u003ch3\u003eShipping and Installation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe Air Science P5-36XT is carefully packaged to protect the cabinet, blower assembly, acrylic panels, and electrical components during shipment. Buyers should verify electrical compatibility and obtain the correct replacement filters before placing the hood into service. Installation should include verification of airflow and proper filter selection according to the laboratory's chemical hygiene plan and applicable safety requirements.\u003c\/p\u003e\n\u003ch3\u003eRelated Laboratory Equipment\u003c\/h3\u003e\n\u003cp\u003eLaboratories purchasing ductless fume hoods often also require analytical balances, laboratory ovens, water purification systems, hot plates and stirrers, vacuum pumps, rotary evaporators, biosafety cabinets, and laboratory refrigerators. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support analytical chemistry, pharmaceutical development, biotechnology, education, and industrial research.\u003c\/p\u003e\n\u003ch3\u003eAir Science Purair BASIC P5-36XT Ductless Fume Hood Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eAre filters included with this hood?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e This refurbished Air Science P5-36XT is sold \u003cstrong\u003ewithout any filters installed\u003c\/strong\u003e. New activated carbon, HEPA, ULPA, or specialty filters must be purchased separately based on the intended laboratory application.\u003c\/p\u003e\n\u003ch4\u003eWhy are filters not included?\u003c\/h4\u003e\n\u003cp\u003eFilter media have a finite service life and their previous exposure history cannot always be verified. Supplying the hood without filters allows the laboratory to install new media specifically selected for its intended chemicals and applications.\u003c\/p\u003e\n\u003ch4\u003eCan any activated carbon filter be installed?\u003c\/h4\u003e\n\u003cp\u003eNo. Filter selection should be based on the chemicals being used. Different activated carbon formulations and specialty filters are designed for different classes of vapors, and some applications may require HEPA or ULPA filtration in addition to chemical filtration.\u003c\/p\u003e\n\u003ch4\u003eIs a ductless fume hood suitable for every chemical?\u003c\/h4\u003e\n\u003cp\u003eNo. Ductless hoods are appropriate only when the installed filters are specifically matched to the chemicals and anticipated usage. Laboratories should perform a chemical compatibility review before operation.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty is included?\u003c\/h4\u003e\n\u003cp\u003eThis refurbished Air Science Purair BASIC P5-36XT Ductless Fume Hood includes a \u003cstrong\u003e90-day warranty\u003c\/strong\u003e from American Instrument Exchange.\u003c\/p\u003e","brand":"American Instrument Exchange","offers":[{"title":"Default Title","offer_id":43408744742960,"sku":"2838D HOOD","price":1650.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.americaninstrument.com\/products\/air-science-purair-basic-p5-36xt-ductless-fume-hood","provider":"American Instrument Exchange","version":"1.0","type":"link"}