{"product_id":"airclean-systems-ac632lfuvc-pcr-workstation","title":"AirClean Systems AC632LFUVC PCR Workstation","description":"\u003ch2\u003e\u003cspan\u003eAirClean Systems AC632LFUVC PCR Workstation – Used \u0026amp; Refurbished\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbished AirClean AC632LFUVC Combination PCR Workstation for Sale\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean Systems AC632LFUVC is a 32-inch combination PCR workstation designed to help minimize sample contamination during polymerase chain reaction (PCR) preparation, molecular biology procedures, DNA amplification workflows, and other contamination-sensitive laboratory applications. Combining HEPA-filtered vertical laminar airflow with timed ultraviolet germicidal irradiation, the AC632LFUVC provides a controlled, ISO Class 5 clean-air environment for preparing PCR reagents and samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis workstation incorporates AirClean Systems' UVTect microprocessor controller, which monitors HEPA filter condition, UV lamp effectiveness, and operating functions. The system also provides variable-speed blower control, programmable UV-C exposure, and a laboratory event timer to support repeatable PCR preparation procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike a conventional PCR enclosure that relies solely on UV light, the AC632LFUVC combines two complementary contamination-control technologies. HEPA-filtered vertical airflow helps reduce airborne particulate contamination during active work, while timed UV-C irradiation provides supplementary surface decontamination between procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 32-inch configuration provides a generous 31-inch-wide interior work area while maintaining a compact benchtop footprint. Its transparent polycarbonate enclosure, folding front sash, integrated pipette holder, and convenient control system make it particularly well suited to laboratories performing frequent PCR setup, DNA amplification, and molecular diagnostic research.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange offers this AirClean AC632LFUVC as a used and refurbished PCR workstation. The unit is professionally inspected, cleaned, refurbished, and functionally tested before shipment, providing laboratories with a cost-effective alternative to purchasing new equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA 90-day warranty is included from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAirClean Systems AC632LFUVC combination PCR workstation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32-inch nominal exterior width\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eISO Class 5 (Class 100) vertical laminar airflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHEPA-filtered clean-air environment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUVTect microprocessor controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e254 nm UV-C germicidal lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProgrammable UV timer, up to 59 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV lamp effectiveness monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous HEPA filter condition monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVariable-speed blower control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLaboratory event timer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransparent polycarbonate enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeamless polypropylene and polycarbonate construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFull-access folding front sash\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic UV shutoff when the sash is opened\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUV-reflective interior construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated UV shelf and pipette holder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical cord access port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow-airflow alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuiet operation, typically below 49 dBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDuctless, benchtop design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefurbished and tested by American Instrument Exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-day warranty included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean Systems AC632LFUVC is designed to provide a clean working environment for molecular biology laboratories where sample contamination can compromise experimental results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePCR is an exceptionally sensitive analytical technique. Even small quantities of contaminating DNA or previously amplified PCR products can produce false-positive results, interfere with amplification, and require expensive or time-consuming repeat testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC addresses this challenge by combining HEPA-filtered vertical laminar airflow with timed UV-C irradiation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDuring active operation, room air enters the workstation through a prefiltration system and passes through a HEPA filter. Clean air then moves vertically downward into the working chamber, helping reduce airborne particulate contamination around PCR reagents, tubes, pipettes, and other materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBetween procedures, the UV-C lamp can be operated with the sash closed to provide supplementary surface decontamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UVTect microprocessor continuously monitors important operating functions, helping users identify when the HEPA filter or UV lamp may require attention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis combination of clean airflow, timed UV exposure, and intelligent monitoring makes the AC632LFUVC particularly useful for laboratories performing repetitive PCR preparation and other contamination-sensitive molecular biology procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Choose the AirClean AC632LFUVC?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC offers several advantages over basic PCR enclosures that provide only an enclosed workspace and UV lighting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts HEPA-filtered vertical laminar airflow helps maintain a clean working environment during active sample preparation. This is particularly valuable when preparing PCR master mixes, aliquoting reagents, handling reaction tubes, or setting up amplification plates.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UVTect controller provides additional operating information by monitoring filtration and UV lamp effectiveness.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe programmable UV timer allows users to establish repeatable UV exposure cycles between procedures, while the integrated pipette holder provides convenient storage for pipettes inside the enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 32-inch width provides substantially more working room than smaller 24-inch PCR workstations without requiring the additional benchtop space of a 48-inch model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories seeking a combination PCR workstation with clean-air protection, UV-C treatment, and electronic monitoring, the AC632LFUVC provides an excellent balance of functionality, workspace, and compact dimensions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHEPA-Filtered Vertical Laminar Airflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOne of the defining features of the AirClean AC632LFUVC is its ISO Class 5 vertical laminar airflow system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRoom air enters the workstation through electrostatic prefiltration before passing through the main HEPA filter. The filtered air then flows downward into the working chamber, creating a clean-air environment intended to minimize airborne particulate contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is particularly useful during PCR setup, where contamination from airborne particles or biological material can interfere with sensitive amplification procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation's vertical airflow arrangement helps direct clean air across the working area while allowing operators to organize reagents, tubes, pipettes, and other materials within the enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UVTect controller includes variable-speed blower adjustment, allowing airflow to be tailored to appropriate applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAs with other laminar-flow workstations, the effectiveness of the clean-air environment depends on proper operation, filter condition, and appropriate work practices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC is designed for sample protection and contamination control. It is not a Class II biological safety cabinet and should not be used when personnel protection from hazardous biological aerosols is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eUV-C Germicidal Irradiation \u0026amp; Contamination Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC incorporates a 254 nm UV-C lamp designed to provide supplementary surface decontamination between laboratory procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUV-C irradiation can help reduce contamination on directly exposed surfaces when used with appropriate exposure times and validated laboratory procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation includes a programmable digital UV timer, allowing operators to select treatment intervals of up to 59 minutes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe enclosure's polycarbonate and polypropylene construction is designed to reflect UV energy within the chamber, while the overlapping front sash helps prevent accidental UV exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAn interlock automatically switches off the UV lamp when the sash is opened.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor PCR laboratories, timed UV exposure can be particularly useful between reagent preparation sessions, helping reduce the risk of carryover contamination from previous procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUV-C irradiation should be considered a supplement to routine cleaning and appropriate chemical decontamination rather than a replacement for those procedures. Its effectiveness depends on lamp condition, exposure time, surface cleanliness, and whether the contaminated area receives sufficient UV exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eUVTect Microprocessor Controller\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC incorporates AirClean Systems' UVTect microprocessor controller, which provides monitoring and control functions beyond those found on many basic PCR workstations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe controller continuously monitors HEPA filter condition and UV lamp effectiveness, helping operators identify maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVariable-speed blower control allows users to adjust airflow to suit appropriate sample preparation procedures, while the digital UV timer supports repeatable treatment cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA separate laboratory event timer provides additional convenience for procedures requiring controlled timing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UVTect system also provides alerts related to operating conditions, helping researchers recognize when the workstation requires attention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories performing PCR setup throughout the day, these monitoring and control features can improve workflow consistency and simplify routine equipment operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTransparent Polycarbonate Enclosure \u0026amp; Operator Visibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC incorporates a transparent polycarbonate enclosure designed to provide excellent visibility of the working chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike enclosed workstations with opaque side panels, the AirClean design allows researchers to observe materials and equipment from multiple angles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis can be particularly useful when organizing PCR tubes, pipette racks, reagent containers, and amplification plates within the workspace.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe full-access folding sash provides convenient access during setup, cleaning, and equipment placement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe enclosure also incorporates a seamless plastic design that minimizes joints and gaps where contaminants or residues might accumulate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese features make the workstation particularly well suited to laboratories requiring frequent cleaning and organized sample preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIntegrated Pipette Holder \u0026amp; Utility Access\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC includes a UV shelf with an integrated pipette holder, providing a convenient location for storing compatible pipettes within the workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaintaining dedicated PCR pipettes inside a designated pre-amplification preparation area can help reduce contamination associated with moving equipment between laboratory work zones.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation also incorporates an access port for electrical cords, allowing compatible equipment to be used inside the chamber when appropriate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese features support an organized PCR preparation environment and help researchers establish consistent workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC is particularly well suited to PCR master mix preparation, reagent aliquoting, DNA and RNA sample preparation, quantitative PCR (qPCR) setup, reverse-transcription PCR (RT-PCR) preparation, molecular biology research, genetic analysis, sequencing-library preparation, and other contamination-sensitive procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt can also support molecular diagnostic research, forensic DNA preparation, environmental DNA testing, food-safety research, and biotechnology applications where clean sample preparation is important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation is especially useful for pre-amplification procedures in laboratories that maintain separate clean and post-amplification work areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Laboratory Types\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean Systems AC632LFUVC PCR Workstation is an excellent choice for molecular biology laboratories, biotechnology companies, pharmaceutical research facilities, university research departments, clinical molecular laboratories, genetic testing facilities, forensic laboratories, environmental testing laboratories, and contract research organizations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts compact 32-inch footprint makes it suitable for laboratories with limited benchtop space, while its HEPA-filtered airflow and UV-C treatment provide useful contamination-control capabilities for facilities performing frequent PCR preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAirClean Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC632LFUVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCombination PCR Workstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUsed and Refurbished\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirflow Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Laminar Flow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eClean-Air Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISO Class 5 \/ Class 100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32\" W × 24\" D × 30\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31\" W × 23\" D × 20\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrimary Filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHEPA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrefiltration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrostatic Prefiltration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eController\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUVTect Microprocessor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUV Lamp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e254 nm UV-C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUV Timer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable, Up to 59 Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHEPA Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Filter Condition Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUV Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUV Lamp Effectiveness Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBlower Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorkstation Lighting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED and UV-C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolycarbonate and Polypropylene\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFront Access\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFolding Polycarbonate Sash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUV Safety\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic UV Shutoff When Sash Opens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUV Shelf, Pipette Holder, Laboratory Event Timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUtility Access\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Cord Access Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Noise\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 49 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVentilation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDuctless \/ Recirculating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110–120V or 220–240V Versions; Verify Unit Nameplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBenchtop, No External Ductwork Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 Days from American Instrument Exchange\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eSpecifications are based on manufacturer information for the AC632LFUVC. Electrical configuration, HEPA filter condition, UV lamp condition, and installed accessories should be confirmed for the individual refurbished unit.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbishment \u0026amp; Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange specializes in used and refurbished laboratory equipment, providing laboratories with cost-effective alternatives to purchasing new instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC is inspected, cleaned, refurbished, and functionally tested prior to shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe refurbishment process includes evaluation of the blower, UVTect controller, lighting, UV lamp operation, sash interlock, operating alarms, enclosure condition, and filtration system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHEPA filter condition and UV lamp performance are important considerations for this model because both systems contribute to its intended contamination-control functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReplacement of consumable components is performed as required by the unit's condition and refurbishment requirements. Customers should confirm whether new HEPA filters or UV lamps are included with the specific unit being purchased.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe refurbished AC632LFUVC includes a 90-day warranty from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC is a compact benchtop PCR workstation that does not require connection to an external exhaust system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith exterior dimensions of approximately 32 inches wide, 24 inches deep, and 30 inches high, it can be accommodated on many conventional laboratory benches.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation should be placed on a stable, level surface with sufficient clearance for airflow and routine operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the enclosure incorporates polycarbonate panels and electrical components, appropriate packaging and handling are important during shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter delivery, laboratories should inspect the unit, verify proper blower and UVTect operation, and confirm the performance of the clean-air and UV systems before placing it into routine use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRelated Laboratory Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean Systems AC632LFUVC PCR Workstation is particularly useful as part of a molecular biology or PCR laboratory workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePCR thermal cyclers, microcentrifuges, refrigerated centrifuges, vortex mixers, pipettes, and laboratory refrigerators can support reagent preparation, sample handling, and amplification procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUltra-low temperature freezers provide long-term storage of sensitive biological materials, while laboratory refrigerators and freezers support the storage of enzymes, reagents, and other temperature-sensitive supplies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories performing cell culture or procedures involving potentially hazardous biological aerosols, appropriately selected biosafety cabinets may be required in addition to the PCR workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange maintains an extensive inventory of used and refurbished laboratory equipment, allowing laboratories to source multiple instruments through a single supplier.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAirClean AC632LFUVC Frequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the AirClean AC632LFUVC used for?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC is a combination PCR workstation designed for contamination-sensitive molecular biology procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is commonly used for PCR master mix preparation, reagent aliquoting, DNA and RNA sample preparation, qPCR setup, and other pre-amplification workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation combines HEPA-filtered vertical airflow with timed UV-C treatment to help reduce contamination risks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the difference between a PCR workstation and a biosafety cabinet?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eA PCR workstation is primarily designed to protect samples and reagents from contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA Class II biosafety cabinet is designed to provide personnel, product, and environmental protection during appropriate biological procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC is not a Class II biosafety cabinet and should not be used as a substitute when containment of hazardous biological aerosols is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the AirClean AC632LFUVC have HEPA filtration?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The AC632LFUVC incorporates HEPA filtration to provide ISO Class 5 vertical laminar airflow within the work chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HEPA filter helps remove airborne particles from the air entering the workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UVTect controller monitors filter condition and alerts users when maintenance may be required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the AirClean Systems AC632LFUVC PCR Workstationhave UV sterilization?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation includes a 254 nm UV-C germicidal lamp with a programmable timer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUV-C exposure can provide supplementary surface decontamination between procedures, but it should not be relied upon as a validated sterilization process for all materials or surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRoutine cleaning and appropriate chemical decontamination remain important.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is UVTect on an AirClean PCR workstation?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eUVTect is AirClean Systems' microprocessor-based control and monitoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt monitors HEPA filter condition and UV lamp effectiveness while providing variable-speed blower control, a digital UV timer, and other operating functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese features help laboratories maintain consistent workstation operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow large is the AirClean AC632LFUVC?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC measures approximately 32 inches wide, 24 inches deep, and 30 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe interior work area measures approximately 31 inches wide, 23 inches deep, and 20 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes it a practical benchtop workstation for laboratories requiring more space than a 24-inch enclosure without the larger footprint of a 48-inch model.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the AirClean AC632LFUVC be used for qPCR?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The workstation is suitable for preparing qPCR reagents, master mixes, reaction tubes, and plates.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts clean-air environment and UV-C treatment features can help reduce contamination during pre-amplification procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGood laboratory practices, including dedicated pipettes and separation of pre- and post-amplification areas, remain essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the AC632LFUVC be used for RNA work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The workstation can support RNA sample preparation and RT-PCR setup where a clean working environment is beneficial.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHowever, HEPA filtration and UV-C treatment do not guarantee an RNase-free environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAppropriate RNase-control procedures, dedicated supplies, and validated cleaning practices are still necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the AirClean AC632LFUVC require external ductwork?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eNo. The AC632LFUVC is a ductless, recirculating PCR workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt uses HEPA-filtered vertical laminar airflow to provide a clean working environment without requiring a connection to an external exhaust system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is not designed to contain hazardous chemical vapors or biological aerosols.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the UV lamp operate while the sash is open?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eNo. The workstation incorporates a safety interlock designed to switch off the UV lamp when the sash is opened.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis helps protect operators from accidental UV-C exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe interlock should be checked during refurbishment and routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the HEPA filter be replaced?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The AC632LFUVC incorporates a replaceable HEPA filtration system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UVTect controller monitors filter condition and provides information about maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe correct replacement filter should be selected according to the manufacturer's specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat happens if the UVTect controller displays an alarm?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eAn alarm may indicate an issue involving airflow, filter condition, UV lamp effectiveness, or another monitored function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe specific alarm should be identified and investigated before continuing contamination-sensitive procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDepending on the cause, the workstation may require filter replacement, UV lamp replacement, adjustment, or electrical service.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eIs a used AirClean AC632LFUVC worth refurbishing?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eIn many cases, yes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AC632LFUVC incorporates a substantial enclosure, HEPA filtration system, UVTect controller, blower, and UV-C lighting components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProblems involving consumable filters, UV lamps, or other serviceable components do not automatically require replacement of the entire workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRepair feasibility depends on overall condition, parts availability, and the cost of restoring proper operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhy purchase a refurbished AirClean AC632LFUVC from American Instrument Exchange?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange specializes in used and refurbished laboratory equipment, helping research facilities reduce equipment acquisition costs while obtaining dependable instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AirClean AC632LFUVC combines HEPA-filtered ISO Class 5 vertical airflow, UV-C surface treatment, UVTect monitoring, and a practical 32-inch workspace.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach refurbished unit is inspected, cleaned, and functionally tested prior to shipment and includes a 90-day warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories seeking an affordable PCR workstation for molecular biology, genetic analysis, and contamination-sensitive sample preparation, the refurbished AirClean AC632LFUVC offers an excellent combination of functionality, workspace, and value.\u003c\/span\u003e\u003c\/p\u003e","brand":"AirClean","offers":[{"title":"Default Title","offer_id":50891434590256,"sku":"1697L CL BENCH","price":2550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/ComingSoon_9c9f16bc-3317-49a7-8f08-21dfb60f2f37.png?v=1793788416","url":"https:\/\/www.americaninstrument.com\/products\/airclean-systems-ac632lfuvc-pcr-workstation","provider":"American Instrument Exchange","version":"1.0","type":"link"}