{"product_id":"baker-rec602-reco2ver-co-incubators-stack-of-two-refurbished","title":"Baker REC602 ReCO2ver CO₂ Incubators – Stack of Two – Refurbished","description":"\u003ch2\u003e\u003cspan\u003eBaker REC602 ReCO2ver Rapid Recovery CO₂ Incubators – Stack of Two – Refurbished\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 ReCO2ver Rapid Recovery CO₂ Incubator Stack is a dual-incubator system designed for mammalian cell culture, tissue culture, biotechnology research, pharmaceutical development, and other applications requiring precise control of temperature, carbon dioxide, and relative humidity. This refurbished Baker REC602 CO2 Incubator Stack includes two Baker REC602 incubators arranged in a vertical stack, providing approximately 11.84 cu. ft. (336 liters) of combined incubation capacity while conserving valuable laboratory floor space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach Baker REC602 CO2 Incubator Stack features two 5.92 cu. ft. (168 L) chambers, direct-heat temperature regulation, infrared CO₂ sensing, active ultrasonic humidification, and a large full-face HEPA filtration system. Baker's proprietary InteliCELL control technology enables exceptionally rapid recovery of environmental conditions following routine door openings, helping minimize disturbances to sensitive cell cultures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvailable refurbished from American Instrument Exchange, this stack of two Baker REC602 CO₂ incubators offers laboratories an economical alternative to purchasing a new dual-incubator system. With independent environmental controls in each chamber, researchers can maintain different cell lines, establish separate experimental conditions, or increase incubation capacity without occupying additional floor space.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eComplete stack of two refurbished Baker REC602 ReCO2ver CO₂ incubators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombined chamber capacity of 11.84 cu. ft. (336 L)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndividual chamber capacity of 5.92 cu. ft. (168 L)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndependent temperature, CO₂, and humidity control in each incubator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature range from ambient +7°C to 55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature accuracy of approximately ±0.1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature uniformity of approximately ±0.25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature recovery to within 1°C of 37°C setpoint in approximately 6 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCO₂ control range from 0% to 20%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-dispersive infrared CO₂ sensor with approximately ±0.15% accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCO₂ recovery to within 0.2% of a 5% setpoint in approximately 5 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eActive ultrasonic humidity delivery without a conventional open water pan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo humidity operating modes: up to 90% RH and 90–95% RH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelative-humidity accuracy of approximately ±3%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHumidity recovery to within 3% of a 90% setpoint in approximately 4 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge full-face HEPA filter supporting better-than-ISO Class 4 particulate air cleanliness\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUniform vertical downward airflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeated-frame, fog-resistant interior glass door\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect-heat chamber construction with coved interior corners\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour standard shelves per incubator; up to twelve shelf positions per chamber\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefurbished and tested by American Instrument Exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-day warranty included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eBaker REC602 CO2 Incubator Stack Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 ReCO2ver is a premium cell culture incubator developed to maintain precise environmental conditions while rapidly recovering from disturbances caused by routine laboratory activity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike conventional CO₂ incubators that may require extended periods to restore chamber temperature, CO₂ concentration, and humidity following a door opening, the ReCO2ver incorporates specialized control technology designed to minimize recovery times.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system combines direct-heat temperature regulation, active ultrasonic humidification, infrared CO₂ sensing, and filtered downward airflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBaker's proprietary InteliCELL control system continuously monitors chamber conditions and adjusts heating, CO₂ injection, and humidity delivery to maintain the selected environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished configuration includes two independent REC602 incubators arranged vertically.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach incubator provides 168 liters of usable capacity, resulting in a combined total of approximately 336 liters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe stacked arrangement is especially useful for laboratories requiring additional incubation capacity but lacking sufficient space for two side-by-side incubators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the chambers operate independently, researchers can maintain different temperature, CO₂, and humidity conditions in each incubator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis flexibility is valuable for laboratories working with multiple cell lines, conducting parallel experiments, or separating research projects.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe REC602's large usable chamber, active humidity control, and advanced contamination-control features make the system particularly attractive for laboratories performing demanding cell culture applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 dual-incubator stack is suitable for mammalian cell culture, stem cell research, tissue engineering, biotechnology development, pharmaceutical research, and other applications requiring stable environmental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAcademic research laboratories can use the two chambers to maintain established cell lines, expand primary cultures, and conduct parallel experiments involving different incubation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBiotechnology companies may use the system for recombinant protein development, antibody research, cell-based assay preparation, and other procedures involving cultured mammalian cells.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePharmaceutical laboratories can use the REC602 for drug discovery, toxicology studies, cell-based screening, and selected preclinical research applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe dual-chamber configuration is particularly useful when researchers need to separate different cell lines or experimental protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor example, one chamber can maintain routine cell cultures while the second is reserved for specialized experiments or contamination-sensitive work.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe rapid environmental recovery capabilities are also valuable in laboratories where incubator doors are opened frequently throughout the day.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor complete cell culture workflows, the Baker REC602 can be paired with \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003e\u003cspan\u003ebiosafety cabinets\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for aseptic handling and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003e\u003cspan\u003elaboratory centrifuges\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for cell harvesting and sample preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003e\u003cspan\u003erefurbished laboratory incubators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003e\u003cspan\u003elaboratory refrigerators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\/-80\"\u003e\u003cspan\u003eultra-low temperature freezers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e are available from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBaker REC602 CO2 Incubator Stack Ideal Laboratory Environments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 stack is particularly well suited for university research laboratories, biotechnology companies, pharmaceutical development facilities, medical research institutions, and laboratories maintaining multiple cell lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts vertically stacked configuration provides substantial incubation capacity without requiring the floor space of two separate side-by-side units.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe independent chambers allow laboratories to organize cultures according to research group, cell type, or experimental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFacilities performing high-throughput cell culture procedures can benefit from the large usable chamber volume and rapid environmental recovery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories maintaining sensitive cell lines may also appreciate the combination of HEPA filtration, active humidity control, and precise CO₂ regulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe dual-incubator arrangement can provide additional workflow flexibility by allowing one chamber to remain in operation while the other is cleaned or prepared for a different experiment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRapid Environmental Recovery \u0026amp; InteliCELL Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOne of the defining advantages of the Baker REC602 is its rapid environmental recovery technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEvery time a CO₂ incubator door is opened, conditioned chamber air is exchanged with the surrounding laboratory atmosphere.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis causes temporary changes in temperature, CO₂ concentration, and relative humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese disturbances can affect sensitive cell cultures, particularly when the incubator is accessed frequently.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe REC602 uses Baker's InteliCELL control system to monitor and regulate the chamber environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer specifications describe recovery of temperature to within 1°C of a 37°C setpoint in approximately six minutes following a defined door-opening disturbance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCO₂ concentration returns to within 0.2% of a 5% setpoint in approximately five minutes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRelative humidity returns to within 3% of a 90% setpoint in approximately four minutes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese recovery characteristics help reduce the amount of time cultures experience conditions outside their intended environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRapid recovery is particularly valuable for laboratories performing frequent sample transfers, cell feeding, passaging, and other routine culture procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual recovery times depend on laboratory ambient conditions, chamber loading, door-opening duration, and operating setpoints.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDirect-Heat Temperature Control \u0026amp; Uniformity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eEach Baker REC602 CO2 Incubator Stack incorporates a direct-heat temperature-control system designed to maintain consistent chamber conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe operating temperature range extends from approximately 7°C above ambient laboratory temperature to 55°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike water-jacketed incubators, which use a surrounding water reservoir as a thermal buffer, the REC602 uses heating elements distributed around the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe InteliCELL controller continuously adjusts heater output to maintain the selected temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer specifications indicate temperature accuracy of approximately ±0.1°C and temperature uniformity of approximately ±0.25°C under defined operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe direct-heat design also contributes to rapid recovery following door openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the system does not require a surrounding water jacket, it avoids the additional maintenance and operating weight associated with water-jacketed incubators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe two chambers in this stacked configuration operate independently, allowing different temperature setpoints when required by laboratory procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories maintaining sensitive mammalian cell cultures, precise temperature regulation supports consistent cell growth and experimental reproducibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInfrared CO₂ Regulation \u0026amp; Culture Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 incorporates a non-dispersive infrared CO₂ sensor designed to provide accurate carbon dioxide measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe CO₂ control range extends from 0% to 20%, accommodating conventional mammalian cell culture and other applications requiring controlled carbon dioxide levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe infrared sensor measures CO₂ concentration through infrared absorption rather than changes in the thermal conductivity of the chamber atmosphere.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis measurement approach is particularly useful when temperature and humidity conditions change following routine door openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer specifications indicate CO₂ accuracy of approximately ±0.15%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system is designed to restore CO₂ concentration to within 0.2% of a 5% setpoint in approximately five minutes under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccurate CO₂ regulation is essential for cell culture media that use bicarbonate buffering to maintain physiological pH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChanges in CO₂ concentration can alter culture-medium pH and potentially affect cell growth, metabolism, and experimental results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach REC602 in the stack has its own CO₂ regulation system, allowing the chambers to operate at different setpoints when needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system requires a suitable regulated CO₂ gas supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eActive Ultrasonic Humidity Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eA particularly important feature of the Baker REC602 CO2 Incubator Stack is its active ultrasonic humidity-delivery system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike conventional CO₂ incubators that rely on passive evaporation from an open water pan, the REC602 uses an ultrasonic nebulizer to introduce moisture into the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system continuously monitors relative humidity and adjusts moisture delivery to maintain the selected operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBaker specifies two humidity operating modes: one supporting conditions up to approximately 90% RH and another designed for approximately 90–95% RH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer specifications indicate humidity accuracy of approximately ±3%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system can restore relative humidity to within 3% of a 90% setpoint in approximately four minutes under defined conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRapid humidity recovery is especially important for laboratories using multiwell plates and other vessels containing relatively small volumes of culture medium.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen relative humidity decreases, evaporation can increase, potentially altering nutrient concentrations and osmolarity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis phenomenon is often associated with the edge effect observed in multiwell plate experiments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe REC602's active humidity system helps reduce evaporation and maintain more consistent culture conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe enclosed humidity-delivery system also eliminates the need for a conventional open water pan, reducing routine maintenance associated with passive humidification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe water reservoir and nebulizer still require appropriate cleaning and maintenance according to the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFull-Face HEPA Filtration \u0026amp; Contamination Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 CO2 Incubator Stack incorporates a large full-face HEPA filtration system designed to maintain exceptionally clean chamber air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system uses uniform vertical downward airflow to distribute filtered air across the culture area.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBaker specifies particulate air cleanliness better than ISO Class 4, equivalent to better than Class 10 under the older Federal Standard 209E classification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is a more stringent particulate cleanliness classification than the ISO Class 5 performance commonly specified for many laboratory CO₂ incubators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe full-face HEPA filter helps reduce airborne particles that could otherwise settle on culture vessels or chamber surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe uniform downward airflow system also contributes to consistent temperature, CO₂ concentration, and humidity distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber incorporates a crevice-free interior with coved corners, simplifying cleaning and reducing areas where contamination may accumulate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe heated-frame inner glass door helps prevent condensation and provides clear visibility into the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows researchers to inspect cultures without unnecessarily opening the inner door.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe REC602 platform also offers optional hydrogen peroxide biodecontamination technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHowever, the standard REC602 should not be assumed to include the automated hydrogen peroxide system unless the appropriate hardware and configuration are verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHEPA filtration and chamber design provide additional contamination protection but do not replace appropriate aseptic technique, cleaning, or laboratory biosafety procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDual-Chamber Flexibility \u0026amp; Laboratory Productivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe stacked Baker REC602 configuration provides two independent incubation environments in a compact footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach chamber can be configured with its own temperature, CO₂, and relative-humidity settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows laboratories to maintain different cell lines or research conditions without requiring separate floor locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor example, one chamber may be dedicated to routine mammalian cell culture while the second is used for specialized research or experimental protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSeparating cultures between chambers can also help laboratories organize workflows and reduce unnecessary handling of unrelated samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system provides a combined 336 liters of chamber capacity, offering substantial space for culture vessels, multiwell plates, and other laboratory containers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach incubator accommodates up to twelve shelves, with four shelves included in the standard manufacturer configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual shelf quantities included with the refurbished stack should be verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe vertical arrangement conserves floor space while providing access to two independently controlled chambers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should use appropriate manufacturer-approved stacking hardware and ensure that the supporting surface is suitable for the combined equipment weight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eChamber Construction \u0026amp; Sample Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eEach Baker REC602 provides approximately 168 liters of usable interior capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe interior chamber measures approximately 19.9 inches wide, 21.9 inches deep, and 33.5 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe exterior dimensions of each incubator are approximately 26.9 inches wide, 26.5 inches deep, and 40.5 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe standard manufacturer configuration includes four shelves per chamber, with support for up to twelve shelves.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach shelf provides approximately 18.6 inches by 20.1 inches of usable surface area.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBaker specifies capacity for up to 275 standard 90 mm plates per chamber, depending on shelf configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe combined stack therefore provides substantial capacity for routine cell culture and high-throughput research.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber interior incorporates smooth surfaces and coved corners for easier cleaning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe heated-frame inner glass door provides visibility into the chamber while reducing condensation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause this listing includes two stacked incubators, the overall installation height and weight must account for the stacking hardware and any installed accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBaker REC602 CO2 Incubator Stack Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThe Baker Company\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREC602 ReCO2ver\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRapid Recovery CO₂ Incubator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStack of two independent incubators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eQuantity Included\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 incubators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCombined Chamber Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.84 cu. ft. (336 L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual Chamber Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.92 cu. ft. (168 L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect heat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient +7°C to 55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Recovery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithin 1°C of 37°C setpoint in approximately 6 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Control Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–20%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-dispersive infrared (NDIR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.15%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Recovery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithin 0.2% of 5% setpoint in approximately 5 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Delivery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActive ultrasonic nebulizer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo modes: up to 90% RH and 90–95% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±3%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Recovery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithin 3% of 90% setpoint in approximately 4 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBaker InteliCELL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAir Circulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniform vertical downward airflow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHEPA Filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-face HEPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Air Cleanliness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBetter than ISO Class 4 under specified conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSmooth, crevice-free chamber with coved corners\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInner Door\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeated-frame, fog-resistant glass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Shelves\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 per incubator; 8 total for standard configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Shelves\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 per incubator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded Shelves\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify actual quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUsable Shelf Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.6\"W × 20.1\"D per shelf\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Dimensions, Each (W × D × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.9\" × 21.9\" × 33.5\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Dimensions, Each (W × D × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.9\" × 26.5\" × 40.5\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Stacked Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify assembled configuration and stacking hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 250 lb. (114 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCombined Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 500 lb. (227 kg), excluding stacking hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 310 lb. (141 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify individual equipment nameplates; 120V configurations available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndependent Chamber Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigeration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndependent Oxygen Regulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified for standard REC602\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eH₂O₂ Biodecontamination\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional; verify installed configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90-day warranty included from American Instrument Exchange\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eSpecifications compiled from Baker manufacturer literature and distributor technical references. Actual shelving, electrical configurations, installed accessories, biodecontamination options, and overall stacked dimensions should be verified for the individual refurbished system.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbishment \u0026amp; Testing by American Instrument Exchange\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis Baker REC602 dual-incubator stack is offered refurbished by American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAIE technicians inspect and evaluate each incubator independently to verify its suitability for continued laboratory use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe refurbishment process includes inspection of the chamber, door gaskets, shelving, heating system, CO₂ sensors, humidity-delivery components, HEPA filtration system, airflow components, and electronic controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach chamber is cleaned, and worn or malfunctioning components are repaired or replaced as necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature performance is evaluated using calibrated monitoring equipment to verify chamber accuracy and stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCO₂ concentration is independently measured to assess sensor accuracy and gas-control performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHumidity regulation, airflow, alarms, and other installed functions are inspected and tested as applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe stacked configuration is also evaluated for appropriate physical stability and compatibility with the installed stacking hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFollowing testing and final inspection, the system is prepared for shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA 90-day warranty is included from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baker REC602 dual-incubator stack requires appropriate installation planning because of its combined height and weight.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system should be positioned on a stable, level surface capable of supporting both incubators and the stacking hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach incubator requires a suitable electrical connection and regulated CO₂ gas supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrical requirements should be verified against the individual equipment nameplates before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe humidity reservoirs should be filled and maintained according to Baker's operating instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-approved stacking hardware should be used to ensure appropriate stability and safe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, each incubator should be allowed to stabilize at its selected temperature, CO₂ concentration, and humidity conditions before sensitive cultures are introduced.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should verify chamber performance using suitable calibrated reference instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange can arrange appropriate shipping for the dual-incubator system and assist customers with installation planning.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBaker REC602 Frequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is included in this Baker REC602 listing?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThis listing includes a stack of two refurbished Baker REC602 ReCO2ver Rapid Recovery CO₂ incubators, providing two independently controlled incubation chambers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the combined capacity of the two incubators?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eEach REC602 provides 5.92 cu. ft. (168 L) of usable chamber capacity. Together, the two incubators provide approximately 11.84 cu. ft. (336 L).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the two incubators operate at different temperatures and CO₂ levels?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. Each REC602 has independent temperature, CO₂, and humidity controls, allowing laboratories to maintain different conditions in each chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow quickly does the Baker REC602 recover after a door opening?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eBaker specifies recovery of temperature within approximately six minutes, CO₂ within five minutes, and relative humidity within four minutes under defined operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Baker REC602 use a water jacket?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eNo. The REC602 uses direct-heat temperature regulation rather than a surrounding water jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat type of CO₂ sensor does the REC602 use?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe REC602 incorporates a non-dispersive infrared CO₂ sensor designed for accurate measurement and rapid environmental recovery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the REC602 have active humidity control?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The incubator uses an ultrasonic nebulizer and digital humidity sensor to actively regulate relative humidity. It does not rely on a conventional open water pan.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the advantage of ultrasonic humidification?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eUltrasonic humidification allows the incubator to restore humidity rapidly following door openings, helping reduce evaporation from culture media and minimize the edge effect in multiwell plates.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Baker REC602 have HEPA filtration?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The incubator incorporates a large full-face HEPA filter and uniform downward airflow designed to provide better-than-ISO Class 4 particulate air cleanliness under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Baker REC602 have hydrogen peroxide decontamination?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eHydrogen peroxide biodecontamination is available as an option on the REC602 platform and is associated with the REC602 Plus configuration. The feature should be confirmed before assuming it is installed on this refurbished stack.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow many shelves are included?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer-standard configuration includes four shelves per incubator, or eight shelves across the stack. The actual number included with the refurbished system should be verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the advantage of purchasing two stacked incubators?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eA stacked system provides two independent incubation environments while conserving floor space. It also allows laboratories to separate cell lines, organize experiments, and maintain different environmental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the temperature range of the Baker REC602?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator operates from approximately 7°C above ambient laboratory temperature to 55°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the CO₂ range of the Baker REC602?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator provides CO₂ control from 0% to 20%.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eIs this Baker REC602 stack refurbished?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. Both Baker REC602 incubators are offered refurbished by American Instrument Exchange. Each unit is inspected, cleaned, and tested to verify temperature, CO₂, humidity, and other installed functions. Necessary repairs are performed before shipment, and the system includes a 90-day warranty.\u003c\/span\u003e\u003c\/p\u003e","brand":"Baker","offers":[{"title":"Default Title","offer_id":51058351308848,"sku":"3128H INC","price":4900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/ComingSoon_188b13ad-b882-4aeb-8d69-a1c0bf907349.png?v=1794405288","url":"https:\/\/www.americaninstrument.com\/products\/baker-rec602-reco2ver-co-incubators-stack-of-two-refurbished","provider":"American Instrument Exchange","version":"1.0","type":"link"}