{"product_id":"baker-sci-tive-hypoxia-workstation","title":"Baker SCI-tive Hypoxia Workstation","description":"\u003ch2 class=\"MsoNormal\"\u003eBaker SCI-tive Hypoxia Workstation\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe refurbished Baker SCI-tive Hypoxia Workstation is a fully integrated “lab-in-a-box” system designed to deliver precise, stable, and physiologically relevant oxygen conditions for advanced cell culture and translational research. Manufactured by The Baker Company, the SCI-tive series is widely trusted for hypoxia and physoxia studies, enabling researchers to replicate in vivo environments with unmatched control over oxygen, carbon dioxide, temperature, and humidity.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SCI-tive Hypoxia Workstation features\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003eTrue In Vivo Simulation\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAccurately replicate physiological oxygen conditions (0.1%–23% O₂) with fine control, supporting hypoxia, normoxia, and physoxia workflows. \u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eIntegrated Environmental Control\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eSimultaneous regulation of O₂, CO₂ (0.1%–30%), temperature, and humidity ensures optimal conditions for sensitive cell cultures. \u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eClosed, Continuous Cell Culture Environment\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintain uninterrupted hypoxic conditions from seeding through analysis, reducing cellular stress caused by environmental fluctuations. \u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eSpacious “Lab-in-a-Box” Design\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eLarge internal chamber (~420L capacity) accommodates microscopes, analyzers, and other instruments—eliminating the need to move samples between environments. \u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eAdvanced Contamination Control\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eInternal HEPA filtration and optional UV sterilization help maintain clean, controlled conditions for sensitive applications\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eUser-Friendly Operation\u003c\/h4\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0in;\"\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eDirect glove port access (Ezee Sleeve™ system)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eRapid interlock transfer system\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eTouchscreen control interface\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l2 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eInternal power outlets and cable management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eApplications for the Baker SCI-tive Hypoxia Workstation include cancer and tumor hypoxia research, stem cell and regenerative medicine, cell and gene therapy development, microbiology and microbiome studies, and drug discovery and translational research. The SCI-tive workstation is particularly valuable for experiments where oxygen sensitivity directly impacts cell behavior and experimental outcomes.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eBaker SCI-tive Hypoxia Workstation Specifications (Typical)\u003c\/h4\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0in;\"\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eOxygen Control: 0.1% – 23% (0.1% increments)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eCO₂ Control: 0.1% – 30%\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eTemperature Range: Ambient +5°C to 45°C\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eHumidity: Up to ~85% RH\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eChamber Volume: ~420L\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eFiltration: HEPA (ISO Class 4 internal environment)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l1 level1 lfo2; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eAccess: Glove ports + interlock transfer system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0in; line-height: normal;\" class=\"MsoNormal\"\u003e\u003ci\u003eSpecifications may vary depending on configuration (single, dual, or custom systems).\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e Testing\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThis Baker SCI-tive workstation is used and reconditioned. Our technicians test all gloveboxes to confirm that they operate properly and to the manufacturer’s specifications. They visually inspect for damage such as cracks, leaks, or worn-out seals. Afterward, conduct a pressure decay test by inflating the glovebox and monitoring if the pressure holds steady.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAdditionally, if you have specific testing requirements or requests, please inform us. We will gladly work with you to ensure these requirements are addressed during testing.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003ePictures\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. We can provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhy Buy Refurbished from American Instrument Exchange?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessionally refurbished and tested by American Instrument Exchange, this system provides the performance of a new workstation at a significantly reduced cost—making it an ideal solution for laboratories seeking high-end capability without the premium price tag.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePurchasing a refurbished SCI-tive workstation from American Instrument Exchange offers significant advantages:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0in;\"\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eCost Savings – Save substantially compared to new equipment\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eCertified Performance – Fully tested and validated to meet OEM specifications\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eWarranty \u0026amp; Support – Backed by experienced service professionals\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eSustainability – Extend the lifecycle of high-quality laboratory equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eEach unit is carefully inspected, serviced, and reconditioned to ensure reliable, long-term performance.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eBaker SCI-tive Hypoxia Workstation frequently asked questions (FAQs)\u003c\/h3\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat is a hypoxia workstation and why is it important?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eA hypoxia workstation like the Baker SCI-tive is a sealed system that allows researchers to culture and manipulate cells under controlled low-oxygen conditions. Unlike standard incubators, the SCI-tive maintains a continuous hypoxic environment, preventing oxygen exposure that can alter cell behavior and experimental results.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eWhat makes the Baker SCI-tive different from standard CO₂ incubators?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eStandard incubators cannot maintain low oxygen levels during handling. The SCI-tive provides a fully enclosed workspace, allowing all processes—from culture to analysis—to occur under precisely controlled atmospheric conditions.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eCan the Baker SCI-tive Hypoxia workstation support multiple users or workflows?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Depending on the configuration (single or dual chamber), SCI-tive systems can support multiple simultaneous workflows or independent atmospheric conditions within separate chambers.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003eDoes the system require special installation?\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eThe SCI-tive workstation requires:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0in;\"\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eGas supplies (O₂, CO₂, N₂)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0in; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eElectrical connection\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list .5in;\" class=\"MsoNormal\"\u003eAdequate lab space and ventilation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange and \u003ca href=\"https:\/\/aielaboratoryservices.com\/\"\u003eAIE Laboratory Services\u003c\/a\u003e can often assist with setup guidance for customers in Greater Boston or throughout New England.\u003c\/p\u003e","brand":"Baker","offers":[{"title":"Default Title","offer_id":42957148356656,"sku":"2737B GLOVE BOX","price":12500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/Baker_SCI-tive_Hypoxia_Workstation.jpg?v=1776436169","url":"https:\/\/www.americaninstrument.com\/products\/baker-sci-tive-hypoxia-workstation","provider":"American Instrument Exchange","version":"1.0","type":"link"}