{"product_id":"binder-kb240-refrigerated-incubator","title":"Binder KB240 Refrigerated Incubator","description":"\u003ch2\u003eBinder KB240 Refrigerated Incubator\u003c\/h2\u003e\n\u003cp\u003eThe Binder KB240 Refrigerated Incubator is a high-performance cooled incubator designed for precise temperature-controlled incubation, stability testing, microbiological research, environmental studies, food testing, pharmaceutical applications, and quality control procedures. With a spacious 8.5 cubic foot (240 liter) chamber and Binder's advanced compressor cooling technology, the KB240 delivers exceptional temperature uniformity and reliable performance across a wide operating range. This refurbished Binder KB240 from American Instrument Exchange offers a cost-effective alternative to new equipment while providing the precise environmental control required for demanding laboratory applications.\u003c\/p\u003e\n\u003ch3\u003eBinder KB240 Refrigerated Incubator Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBinder KB240 refrigerated incubator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e240 liter (8.5 cu. ft.) chamber capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature range from 0°C to 70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced compressor cooling technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAPT.line™ preheating chamber technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMicroprocessor controller with digital display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent temperature uniformity and recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless steel chamber interior\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable shelving system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterior glass door\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eForced convection airflow system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefurbished and tested by American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90-day warranty included from American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBinder KB240 Refrigerated Incubator Key Overview\u003c\/h3\u003e\n\u003cp\u003eThe Binder KB240 is engineered to provide precise and reproducible temperature control for applications requiring both cooling and heating capability. Utilizing Binder's APT.line™ preheating chamber technology, the KB240 delivers excellent temperature uniformity throughout the chamber while minimizing temperature fluctuations and recovery times following door openings. The compressor-based refrigeration system allows operation down to 0°C, making the incubator suitable for applications that require temperatures below ambient conditions. Combined with forced-air convection and a stainless steel chamber interior, the KB240 provides a stable environment for long-term incubation, stability testing, and environmental simulation studies.\u003c\/p\u003e\n\u003ch3\u003eCommon Applications for the Binder KB240 Refrigerated Incubator\u003c\/h3\u003e\n\u003cp\u003eThe Binder KB240 is commonly used for microbiological incubation, BOD testing, pharmaceutical stability studies, food and beverage testing, environmental monitoring, seed germination studies, shelf-life testing, quality control procedures, and general laboratory incubation applications. The broad temperature range and precise control make the unit suitable for both routine incubation and research applications requiring highly reproducible environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eIdeal Lab Types for the Binder KB240 Refrigerated Incubator\u003c\/h3\u003e\n\u003cp\u003eThis refrigerated incubator is well suited for pharmaceutical laboratories, biotechnology companies, food and beverage testing facilities, environmental laboratories, water treatment laboratories, agricultural research facilities, university research departments, and industrial quality control laboratories. Facilities utilizing \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/balances\"\u003eanalytical balances\u003c\/a\u003e often incorporate refrigerated incubators such as the KB240 into their testing and research workflows.\u003c\/p\u003e\n\u003ch3\u003eBinder KB240 Refrigerated Incubator Key Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKB240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eRefrigerated Incubator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Capacity\u003c\/td\u003e\n\u003ctd\u003e240 Liters (8.5 cu. ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd\u003eExcellent Uniformity with APT.line™ Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection Type\u003c\/td\u003e\n\u003ctd\u003eForced Air Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling System\u003c\/td\u003e\n\u003ctd\u003eCompressor Refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelves Included\u003c\/td\u003e\n\u003ctd\u003eAdjustable Shelving System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Door\u003c\/td\u003e\n\u003ctd\u003eGlass Inner Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eDigital Microprocessor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 36.8\" W x 31.5\" D x 57.3\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 25.2\" W x 19.8\" D x 30.7\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e115V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSpecifications compiled from Binder manufacturer literature, distributor technical references, and American Instrument Exchange product information.\u003c\/p\u003e\n\u003ch3\u003eRefurbishment and Testing Process\u003c\/h3\u003e\n\u003cp\u003eAt American Instrument Exchange, each refurbished refrigerated incubator is inspected and evaluated by our technicians prior to shipment. Testing procedures may include temperature control verification, refrigeration system evaluation, controller functionality testing, display verification, door gasket inspection, shelf assessment, airflow testing, and general operational testing. Components showing excessive wear are addressed as needed to help ensure reliable performance. Final cleaning and inspection are completed before packaging and shipment.\u003c\/p\u003e\n\u003ch3\u003eShipping and Installation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe Binder KB240 requires adequate ventilation clearance around the cabinet to ensure proper refrigeration performance. Buyers should verify available floor space, doorway clearances, electrical requirements, and final installation location prior to delivery. The unit should be transported upright whenever possible and allowed to stabilize after shipment before startup. Proper installation and routine preventative maintenance can help maximize temperature performance and equipment longevity.\u003c\/p\u003e\n\u003ch3\u003eRelated Laboratory Equipment\u003c\/h3\u003e\n\u003cp\u003eLaboratories purchasing refrigerated incubators often also require \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003efreezers\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/balances\"\u003eanalytical balances\u003c\/a\u003e. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support incubation, testing, sample preparation, and research workflows.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBinder KB240 Refrigerated Incubator Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eWhat makes the Binder KB240 different from a standard laboratory incubator?\u003c\/h4\u003e\n\u003cp\u003eUnlike a standard incubator that typically operates only above ambient temperature, the KB240 incorporates a compressor-based refrigeration system that allows precise temperature control from 0°C to 70°C, making it suitable for both cooling and heating applications.\u003c\/p\u003e\n\u003ch4\u003eIs the Binder KB240 suitable for pharmaceutical stability testing?\u003c\/h4\u003e\n\u003cp\u003eYes. The KB240 is commonly used for pharmaceutical stability studies, shelf-life testing, and other applications requiring precise and reproducible temperature control over extended periods.\u003c\/p\u003e\n\u003ch4\u003eWhat is Binder APT.line™ technology?\u003c\/h4\u003e\n\u003cp\u003eAPT.line™ technology utilizes a preheating chamber design that promotes excellent temperature uniformity and recovery performance throughout the chamber, helping improve test reproducibility and sample consistency.\u003c\/p\u003e\n\u003ch4\u003eCan the KB240 be used for microbiology and BOD testing?\u003c\/h4\u003e\n\u003cp\u003eYes. The KB240 is widely used for microbiological incubation, BOD testing, environmental monitoring, and food testing applications where precise temperature control is required.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty is included?\u003c\/h4\u003e\n\u003cp\u003eThis refurbished Binder KB240 Refrigerated Incubator includes a 90-day warranty from American Instrument Exchange.\u003c\/p\u003e","brand":"Binder","offers":[{"title":"Default Title","offer_id":43309695467568,"sku":"3104J INC","price":3900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0642a.jpg?v=1781882875","url":"https:\/\/www.americaninstrument.com\/products\/binder-kb240-refrigerated-incubator","provider":"American Instrument Exchange","version":"1.0","type":"link"}