{"product_id":"fisher-scientific-fb120-sonic-dismembrator","title":"Fisher Scientific FB120 Sonic Dismembrator","description":"\u003ch2\u003eFisher Scientific FB120 Sonic Dismembrator\u003c\/h2\u003e\n\u003cp\u003eThe Fisher Scientific FB120 Sonic Dismembrator is a compact, high-performance ultrasonic processor engineered for precise cell disruption, homogenization, and molecular sample preparation. Designed for research labs requiring reliable small-volume processing, this system delivers consistent, reproducible sonication for applications ranging from protein extraction to DNA shearing.\u003c\/p\u003e\n\u003ch3\u003eFisher Scientific FB120 features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1joz7tq\" data-start=\"1827\" data-end=\"1896\"\u003e120W ultrasonic output (20 kHz) for efficient cell disruption\u003c\/li\u003e\n\u003cli data-section-id=\"oohxhl\" data-start=\"1897\" data-end=\"1998\"\u003eWide volume range: 0.2–50 mL for versatile applications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"djnc9o\" data-start=\"1999\" data-end=\"2112\"\u003eProgrammable operation (1 sec to 10 hours) for repeatable protocols \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13gcis4\" data-start=\"2113\" data-end=\"2230\"\u003ePulse mode (1–59 seconds) to reduce heat buildup and sample degradation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ei8t3t\" data-start=\"2231\" data-end=\"2346\"\u003eEnergy display (Watts \u0026amp; Joules) for process monitoring and validation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nf6u7\" data-start=\"2347\" data-end=\"2418\"\u003eOverload protection for safe operation and instrument longevity\u003c\/li\u003e\n\u003cli data-section-id=\"ct2oiv\" data-start=\"2419\" data-end=\"2530\"\u003eCompact footprint (13.5\" x 8\" x 6\") for easy benchtop integration \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"232u84\" data-start=\"2531\" data-end=\"2598\"\u003eHandheld converter for flexible use and ergonomic operation\u003c\/li\u003e\n\u003cli data-section-id=\"j3p7ok\" data-start=\"2599\" data-end=\"2675\"\u003eCompatible with multiple probes, cup horns, and multi-sample accessories\u003c\/li\u003e\n\u003cli data-section-id=\"j3p7ok\" data-start=\"2599\" data-end=\"2675\"\u003eRefurbished with 90-day warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1072\" data-end=\"1457\"\u003eWith 120 watts of ultrasonic power at 20 kHz, the Model 120 efficiently processes volumes from 0.2 mL to 50 mL, making it ideal for genomics, proteomics, and general life science workflows. Its programmable operation, pulse mode, and energy monitoring ensure precise control over sample treatment and minimize variability between runs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1459\" data-end=\"1803\"\u003eThe included lightweight handheld converter and microtip probe allow flexible operation, whether mounted or handheld, while the intuitive interface supports both manual and automated workflows. Built-in overload protection and energy tracking (watts\/joules) enhance both safety and reproducibility.\u003c\/p\u003e\n\u003cp data-start=\"1459\" data-end=\"1803\"\u003eProfessionally refurbished by American Instrument Exchange, we fully test each unit and validate to meet original performance standards—providing exceptional value compared to the cost of new equipment while maintaining the reliability your lab demands.\u003c\/p\u003e\n\u003cp data-start=\"1459\" data-end=\"1803\"\u003eApplications for the Fisherbrand FB120 Sonic Dismembrator include cell lysis and disruption, protein extraction and enzyme release, DNA\/RNA shearing (e.g., ChIP assays), emulsification and nanoparticle dispersion, aid microbial and tissue homogenization, among others. \u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"3517\" data-end=\"3544\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3546\" data-end=\"3869\"\u003e\n\u003cli data-section-id=\"1ric7z8\" data-start=\"3546\" data-end=\"3577\"\u003e\n\u003cstrong data-start=\"3548\" data-end=\"3565\"\u003ePower Output:\u003c\/strong\u003e 120 Watts\u003c\/li\u003e\n\u003cli data-section-id=\"t8kap9\" data-start=\"3578\" data-end=\"3603\"\u003e\n\u003cstrong data-start=\"3580\" data-end=\"3594\"\u003eFrequency:\u003c\/strong\u003e 20 kHz\u003c\/li\u003e\n\u003cli data-section-id=\"15evn9a\" data-start=\"3604\" data-end=\"3637\"\u003e\n\u003cstrong data-start=\"3606\" data-end=\"3623\"\u003eVolume Range:\u003c\/strong\u003e 0.2 – 50 mL\u003c\/li\u003e\n\u003cli data-section-id=\"8ie7st\" data-start=\"3638\" data-end=\"3673\"\u003e\n\u003cstrong data-start=\"3640\" data-end=\"3650\"\u003eTimer:\u003c\/strong\u003e 1 second to 10 hours\u003c\/li\u003e\n\u003cli data-section-id=\"185w91f\" data-start=\"3674\" data-end=\"3706\"\u003e\n\u003cstrong data-start=\"3676\" data-end=\"3691\"\u003ePulse Mode:\u003c\/strong\u003e 1–59 seconds\u003c\/li\u003e\n\u003cli data-section-id=\"1shlyho\" data-start=\"3707\" data-end=\"3742\"\u003e\n\u003cstrong data-start=\"3709\" data-end=\"3721\"\u003eVoltage:\u003c\/strong\u003e 110\/117V, 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"18ggl06\" data-start=\"3743\" data-end=\"3790\"\u003e\n\u003cstrong data-start=\"3745\" data-end=\"3772\"\u003eDimensions (L x W x H):\u003c\/strong\u003e 13.5\" x 8\" x 6\"\u003c\/li\u003e\n\u003cli data-section-id=\"zcx3jz\" data-start=\"3791\" data-end=\"3869\"\u003e\n\u003cstrong data-start=\"3793\" data-end=\"3805\"\u003eDisplay:\u003c\/strong\u003e Energy (Watts \u0026amp; Joules)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFisher Scientific FB120 Testing\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThis unit is used and reconditioned. Our technicians test all equipment to confirm that they operate properly and to the manufacturer’s specifications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhile we can’t test for a specific analytical application, we do our best to simulate the conditions under which the equipment runs in a lab. Additionally, if you have specific testing requirements or requests, please inform us. \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePictures\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe photos above are representative. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor inquiries about pricing and availability, call us at 978-521-2221 or fill out the form on this page.\u003c\/p\u003e\n\u003ch2 data-section-id=\"195ecoo\" data-start=\"3876\" data-end=\"3911\"\u003eFisher Scientific FB120 Sonic Dis membratorFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003ch4 data-section-id=\"40tca4\" data-start=\"3913\" data-end=\"3954\"\u003eWhat is a sonic dismembrator used for?\u003c\/h4\u003e\n\u003cp data-start=\"3955\" data-end=\"4184\"\u003eA sonic dismembrator uses ultrasonic energy to break apart cells and particles in liquid samples. The Model 120 is commonly used for cell lysis, protein extraction, and DNA shearing, especially in molecular biology workflows.\u003c\/p\u003e\n\u003ch4 data-section-id=\"101yh5b\" data-start=\"4191\" data-end=\"4240\"\u003eWhat sample volumes can the Model 120 process?\u003c\/h4\u003e\n\u003cp data-start=\"4241\" data-end=\"4454\"\u003eThe system supports 0.2 mL to 50 mL, depending on the probe size used. Smaller microtips are ideal for microcentrifuge tubes, while larger probes support higher volumes.\u003c\/p\u003e\n\u003ch4 data-section-id=\"xzzgfd\" data-start=\"4727\" data-end=\"4786\"\u003eHow does programmable operation improve reproducibility?\u003c\/h4\u003e\n\u003cp data-start=\"4787\" data-end=\"5004\"\u003eThe built-in timer and pulse settings allow you to standardize sonication cycles, ensuring consistent energy delivery across experiments—critical for reproducible results in assays like ChIP or protein extraction.\u003c\/p\u003e\n\u003ch4 data-section-id=\"1unhmre\" data-start=\"5011\" data-end=\"5057\"\u003eWhat is pulse mode and why is it important?\u003c\/h4\u003e\n\u003cp data-start=\"5058\" data-end=\"5259\"\u003ePulse mode alternates between on\/off cycles, which helps reduce heat buildup and protects temperature-sensitive samples from degradation during sonication.\u003c\/p\u003e\n\u003ch4 data-section-id=\"ejvhsb\" data-start=\"5779\" data-end=\"5827\"\u003eDoes the system require special installation?\u003c\/h4\u003e\n\u003cp data-start=\"5828\" data-end=\"6005\"\u003eNo special installation is required. The unit operates on standard 110\/117V power and is designed for benchtop use. However, a stand is recommended for hands-free operation.\u003c\/p\u003e\n\u003ch4 data-section-id=\"4ws3yw\" data-start=\"6012\" data-end=\"6059\"\u003eHow loud is the instrument during operation?\u003c\/h4\u003e\n\u003cp data-start=\"6060\" data-end=\"6227\"\u003eLike most ultrasonic processors, it produces\u003cstrong\u003e \u003c\/strong\u003eaudible high-frequency noise. Use of the sound enclosure (included with purchase from American Instrument Exchange) or operating within a lab hood is recommended for user comfort.\u003c\/p\u003e\n\u003cp data-start=\"6060\" data-end=\"6227\"\u003e \u003c\/p\u003e","brand":"American Instrument Exchange","offers":[{"title":"Default Title","offer_id":42952370815024,"sku":"1237M CELL DIS","price":3450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/Fisher_Scientific_FB120_Sonic_Dismembrator.jpg?v=1776973396","url":"https:\/\/www.americaninstrument.com\/products\/fisher-scientific-fb120-sonic-dismembrator","provider":"American Instrument Exchange","version":"1.0","type":"link"}