{"product_id":"nuaire-labgard-nu425-500-5-biosafety-cabinet-0875j-bio-cab","title":"Nuaire 425-500 biosafety cab","description":"\u003ch2 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Biosafety Cabinet – Refurbished\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-425-500 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring contamination-controlled airflow and sterile working conditions. Commonly used for cell culture, microbiology, pharmaceutical research, and biotechnology workflows, this refurbished Nuaire biosafety cabinet offers reliable containment performance for laboratories requiring advanced airflow protection and contamination-sensitive sample handling.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAt American Instrument Exchange, each biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories outfitting containment-focused workflows may also browse additional biosafety cabinets, clean benches, laboratory incubators, centrifuges, refrigerators, and freezers available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Key Features\u003c\/h3\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eClass II Type A2 biosafety cabinet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e5-foot workspace configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e30% exhaust \/ 70% recirculation airflow design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNSF\/ANSI 49 compliant design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for personnel, product, and environmental protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes stand and new HEPA filters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e90-day warranty included from American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefurbished and tested by American Instrument Exchange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHEPEX™ zero-leak airflow system\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eErgonomic operator workstation design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for tissue culture, microbiology, and pharmaceutical workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Overview\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-425-500 is a 5-foot Class II Type A2 biosafety cabinet engineered for laboratory environments requiring contamination control, sterile airflow, and operator protection. The NU-425 series has been widely used throughout biotechnology laboratories, pharmaceutical facilities, hospital laboratories, academic research institutions, and clinical environments because of its airflow stability, ergonomic workspace design, and contamination-control performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis cabinet configuration is commonly used for sterile laboratory workflows involving biological samples, tissue culture procedures, microbiology applications, pharmaceutical preparation, and contamination-sensitive laboratory tasks requiring both operator protection and product protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe NU-425-500 operates using a 30% exhaust and 70% recirculation airflow design at approximately 100 FPM intake velocity. Depending on laboratory requirements, the cabinet may either recirculate filtered air back into the room or be connected to a canopy exhaust system for additional exhaust flexibility.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFeatures may include HEPEX™ zero-leak airflow construction, stainless steel interior work surfaces, fluorescent lighting, Magnehelic airflow gauge monitoring, internal electrical outlets, ergonomic sash positioning, and heavy-duty cabinet construction depending on the specific configuration of the unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 5-foot workspace configuration may make this biosafety cabinet especially appropriate for laboratories requiring additional working area while maintaining a more compact footprint than larger 6-foot models.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Common Applications\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Nuaire LabGard NU-425-500 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow and contamination control. Typical applications include cell culture workflows, microbiology procedures, tissue culture applications, sterile pharmaceutical preparation, biotechnology research, biological sample handling, and contamination-sensitive laboratory workflows.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may also be appropriate for biotechnology laboratories, pharmaceutical production facilities, clinical testing laboratories, hospital laboratories, academic research facilities, and life science laboratories performing sterile biological workflows or contamination-sensitive research applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eLaboratories building out complete laboratory workflows may also be interested in laboratory incubators, centrifuges, freezers, refrigerators, and cleanroom equipment available through American Instrument Exchange.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Ideal Laboratory Environments\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThis biosafety cabinet may be suitable for biotechnology laboratories, pharmaceutical production environments, hospital laboratories, academic research facilities, clinical diagnostics laboratories, government research institutions, GMP facilities, and cleanroom applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts 5-foot workspace and containment-focused airflow system make it especially appropriate for laboratories requiring controlled working conditions for biological procedures, sterile workflows, and contamination-sensitive laboratory applications while conserving laboratory floor space.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Key Specifications\u003c\/h3\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNuaire\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLabGard NU-425-500\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCabinet Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eClass II Type A2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Width\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e5 ft\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAirflow Design\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e30% exhaust \/ 70% recirculation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExterior Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 65 5\/8” W × 32 7\/8” D × 63” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInterior Work Area Dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 58” W × 23 1\/2” D × 28 1\/2” H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSash Opening\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e10 in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFiltration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHEPA supply and exhaust filtration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e115V, 60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApprox. 550–700 lbs depending on configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStand and new HEPA filters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e90-day warranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCondition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefurbished\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Refurbishment and Testing\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange has extensive experience refurbishing used biosafety cabinets and laboratory containment equipment for research and pharmaceutical environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEach biosafety cabinet is inspected by our technicians to verify proper blower operation, airflow performance, sash operation, control operation, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTesting procedures include major functional and airflow verification elements associated with biosafety cabinet performance to help support certification readiness upon installation at your facility. Final certification should be completed by qualified field technicians after installation in accordance with laboratory requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Certification Readiness\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets should be certified by qualified field technicians after installation and before laboratory use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, airflow requirements, electrical requirements, and certification standards prior to installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification services are available through our affiliate company AIE Laboratory Services, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCertification requirements may vary depending on laboratory protocols, facility standards, and application requirements.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Shipping and Installation Considerations\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBiosafety cabinets are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, electrical compatibility, and final cabinet placement before shipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDepending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe 5-foot cabinet configuration may provide a balance between usable sterile workspace and easier laboratory placement compared to larger containment systems.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"MsoNormal\"\u003eNuaire LabGard NU-425-500 Frequently Asked Questions\u003c\/h3\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhy do many laboratories prefer the Nuaire NU-425-500 over larger 6-foot biosafety cabinets?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe NU-425-500 provides a large 5-foot sterile workspace while maintaining a more manageable laboratory footprint than larger 6-foot systems. Many laboratories choose 5-foot cabinets because they offer strong workflow flexibility without requiring as much floor space or delivery clearance.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhat makes the NU-425 series popular in university and research laboratories?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe NU-425 series has been widely used for decades in academic research, biotechnology, and hospital laboratory environments because of its durable cabinet construction, reliable airflow performance, and long service life. Many laboratories continue supporting these cabinets because replacement parts and field service expertise remain widely available.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eDoes American Instrument Exchange replace HEPA filters during refurbishment?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Unless otherwise specified, American Instrument Exchange installs new HEPA filters before shipment. Cabinets are inspected and tested by our technicians prior to delivery to help support certification readiness after installation.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhat condition should buyers expect from a refurbished NU-425-500?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAmerican Instrument Exchange technicians inspect cabinet controls, blower systems, airflow performance, sash operation, lighting systems, and overall cabinet condition before shipment. Cabinets are cleaned, tested, and prepared for laboratory installation prior to delivery.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eCan the NU-425-500 be connected to a canopy exhaust system?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Depending on laboratory requirements and facility engineering standards, the NU-425-500 may be compatible with canopy exhaust configurations while still operating as a recirculating Type A2 biosafety cabinet.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eWhat types of workflows commonly use the NU-425-500?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include cell culture procedures, microbiology workflows, sterile pharmaceutical preparation, molecular biology research, tissue culture applications, and contamination-sensitive biotechnology workflows.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eCan American Instrument Exchange help coordinate biosafety cabinet certification?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. Certification services are available through AIE Laboratory Services, which provides biosafety cabinet certification, preventative maintenance, repair, testing, and field service support for laboratory containment equipment.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eDoes the NU-425-500 require special shipping arrangements?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause this is a 5-foot biosafety cabinet, buyers should confirm doorway clearances, freight elevator dimensions, hallway access, and final installation location before shipment. Liftgate delivery, inside delivery, or rigging assistance may be recommended depending on the facility layout.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003eDoes the cabinet include a warranty?\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eYes. A 90-day warranty from American Instrument Exchange is included with the cabinet.\u003c\/p\u003e","brand":"Nuaire","offers":[{"title":"$7900.00","offer_id":28870829998128,"sku":"0875J BIO CAB","price":7900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/products\/0875J_BIO_CAB_00.jpg?v=1560355188","url":"https:\/\/www.americaninstrument.com\/products\/nuaire-labgard-nu425-500-5-biosafety-cabinet-0875j-bio-cab","provider":"American Instrument Exchange","version":"1.0","type":"link"}