{"product_id":"sheldon-manufacturing-bactron-iii-anaerobic-chamber","title":"Sheldon Manufacturing Bactron III Anaerobic Chamber","description":"\u003ch2\u003e\u003cspan\u003eSheldon Manufacturing Bactron III Anaerobic Chamber – Refurbished\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Sheldon Manufacturing Bactron III Anaerobic Chamber is a laboratory anaerobic workstation designed for the cultivation, incubation, examination, and handling of oxygen-sensitive microorganisms in a controlled, low-oxygen environment. Manufactured by Sheldon Manufacturing under the SHEL LAB brand, the Bactron III combines an enclosed working chamber, integrated incubation capabilities, and a specimen transfer airlock to support anaerobic microbiology and bacteriology applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III allows laboratory personnel to manipulate cultures and specimens without repeatedly exposing them to atmospheric oxygen. Its enclosed workspace provides a practical alternative to traditional anaerobic jars and gas-generating systems, particularly for laboratories performing frequent culture handling, inoculation, inspection, and incubation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished Sheldon Manufacturing Bactron III, part number 9170587, is offered by American Instrument Exchange. The unit is configured for 120V, 9.0A, 50\/60Hz electrical service and provides laboratories with an economical alternative to purchasing a new anaerobic workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange inspects and tests refurbished laboratory equipment before shipment and includes a 90-day warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSheldon Manufacturing Bactron III anaerobic workstation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for cultivation and handling of oxygen-sensitive microorganisms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnclosed anaerobic working chamber\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated temperature-controlled incubation compartment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAirlock transfer system for introducing and removing specimens\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGlove-port access for specimen handling and manipulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransparent chamber panels for observation of cultures and procedures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControlled gas atmosphere for anaerobic microbiology applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with appropriate anaerobic gas mixtures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports culture inoculation, incubation, inspection, and recovery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for clinical and research microbiology laboratories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical requirements: 120V, 9.0A, 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer part number 9170587\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefurbished and tested by American Instrument Exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-day warranty included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Sheldon Bactron III is a specialized laboratory workstation developed to provide a controlled environment for working with microorganisms that are sensitive to oxygen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConventional anaerobic culture methods often require sealed jars, specialized gas-generating systems, or repeated transfers between separate handling and incubation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III simplifies these procedures by combining an enclosed work area with integrated incubation and specimen transfer capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratory personnel can introduce culture plates and other compatible materials through the airlock, perform manipulations inside the chamber, and transfer specimens to the incubation compartment without routinely exposing the cultures to room air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis arrangement is particularly valuable when working with strict anaerobes or performing procedures that require prolonged manipulation of oxygen-sensitive samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSheldon Manufacturing Bactron III Anaerobic Chamber Common Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III is used for anaerobic bacteriology, clinical microbiology, microbiological culture preparation, anaerobic organism isolation, and research involving oxygen-sensitive microorganisms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional applications include preparation and examination of anaerobic cultures, inoculation of culture media, recovery of anaerobic bacteria, and studies of microbial growth under controlled atmospheric conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system can also support selected research involving anaerobic microbial communities and oxygen-sensitive biological materials, provided the required environmental conditions can be maintained.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSheldon Manufacturing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSHEL LAB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBactron III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9170587\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnaerobic Chamber \/ Anaerobic Workstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosed Anaerobic Workspace\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncubation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Temperature-Controlled Incubator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecimen Transfer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAirlock System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperator Access\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGlove-Port \/ Sleeve Access\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Visibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransparent Viewing Panels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmosphere\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlled Anaerobic Gas Mixture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Gas Supply Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmosphere Management\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGas Exchange and Oxygen-Removal System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncubator Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify Against Original Bactron III Documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Incubator Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorkspace Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify Individual Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncubator Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify Individual Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirlock Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify Individual Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify Individual Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 1,080 VA Maximum Based on Nameplate Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSerial Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRecorded on Manufacturer Nameplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUsed \/ Refurbished\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 Days\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eElectrical specifications are taken from the manufacturer's identification label on the actual equipment. The Bactron III is an earlier-generation instrument; dimensions, plate capacities, and controller specifications for current Bactron models should not be assumed to apply to this unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Laboratory Types\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Sheldon Bactron III is well suited to clinical microbiology laboratories, hospital research facilities, academic microbiology departments, pharmaceutical research laboratories, biotechnology facilities, and institutions studying anaerobic microorganisms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is particularly useful for laboratories that routinely cultivate strict anaerobes or require a controlled atmosphere for culture manipulation and incubation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eControlled Anaerobic Atmosphere\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe principal function of the Bactron III is to provide an enclosed environment suitable for handling oxygen-sensitive microorganisms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAnaerobic microorganisms may be inhibited or damaged by exposure to atmospheric oxygen, making environmental control an important part of successful cultivation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III uses an appropriate anaerobic gas mixture and an atmosphere-management system to establish and maintain low-oxygen conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe specific gas mixture, operating pressure, and oxygen-removal procedures must follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber should be fully conditioned and its atmosphere verified before sensitive cultures are introduced.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIntegrated Anaerobic Incubator\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III incorporates a temperature-controlled incubation compartment within the anaerobic workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis arrangement allows laboratory personnel to move prepared cultures into incubation without routinely transferring them through room air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaintaining cultures within the controlled atmosphere can help reduce interruptions to anaerobic conditions during routine handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator is intended to provide stable temperatures for compatible microbiological applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual temperature range, stability, and uniformity should be verified during refurbishment and documented for the individual unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAirlock Transfer System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe specimen transfer airlock is an essential component of the Bactron III.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt allows culture plates, supplies, and other compatible materials to enter or leave the workstation while limiting the introduction of atmospheric oxygen into the main chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDuring operation, the airlock atmosphere is exchanged according to the manufacturer's prescribed procedure before the internal door is opened.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProper airlock operation helps maintain chamber conditions during repeated specimen transfers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe airlock seals, doors, valves, and cycling mechanism should be inspected and tested before laboratory use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGlove-Port Access and Specimen Handling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Sheldon Manufacturing Bactron III Anaerobic Chamber provides operator access through its chamber ports and compatible sleeve or cuff assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis arrangement allows researchers to manipulate culture plates, inoculation tools, and other laboratory materials while maintaining the enclosed atmosphere.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe transparent chamber construction provides visibility of the workspace during handling and inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProperly maintained sleeves, cuffs, and seals are important for preventing atmospheric oxygen from entering the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAny worn or damaged access components should be replaced before the unit is placed into service.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAnaerobic Culture Preparation and Incubation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III supports a workflow in which specimens can be introduced, prepared, inoculated, incubated, and examined within the same controlled environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis can be especially useful for strict anaerobes that are sensitive to oxygen exposure during transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe workstation may also reduce the need to repeatedly open and close individual anaerobic culture containers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should follow established microbiological procedures for media preparation, organism handling, environmental monitoring, and contamination prevention.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOxygen Control and Environmental Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSuccessful anaerobic culture depends on maintaining the appropriate chamber atmosphere throughout operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III's atmosphere-management components help establish conditions suitable for anaerobic work.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOxygen indicators or suitable oxygen-measurement equipment should be used to verify that the chamber has reached the required conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRegular inspection of the airlock, seals, tubing, gas connections, and oxygen-removal components is important for maintaining performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChamber performance depends on the condition of these components, the gas supply, and the operating procedures used.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGas Supply Requirements\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Sheldon Bactron III requires an appropriate external gas supply for anaerobic operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAnaerobic workstations commonly use manufacturer-specified gas mixtures containing nitrogen, hydrogen, and carbon dioxide, although the exact composition must be confirmed for this model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system may require compatible gas regulators, tubing, and atmosphere-conditioning components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGas cylinders and regulators should be installed according to applicable laboratory safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III should not be operated with an improvised gas mixture or an unverified gas connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbishment and Testing by American Instrument Exchange\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange supplies refurbished laboratory equipment for microbiology, biotechnology, pharmaceutical research, and other laboratory applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor a Sheldon Bactron III, relevant refurbishment and testing procedures include inspecting the chamber enclosure, checking the condition of the access ports and seals, testing the airlock mechanism, and evaluating the integrated incubator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe gas connections, valves, atmosphere-management components, electrical system, and temperature controller should also be inspected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhere appropriate test equipment and gas supplies are available, chamber leak integrity, anaerobic atmosphere establishment, and incubator temperature performance should be evaluated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCustomers requiring documented oxygen measurements, temperature mapping, or confirmation of specific operating accessories should discuss these requirements with AIE before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe refurbished Bactron III includes a 90-day warranty from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Sheldon Bactron III is a specialized laboratory instrument that requires careful handling during transportation and installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber should be protected against impact, vibration, and damage to its transparent panels, access ports, airlock, and internal components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation requires a suitable laboratory work surface or stand, compatible electrical service, and the correct anaerobic gas supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's identification label specifies 120V, 9.0A, 50\/60Hz electrical service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should also ensure adequate space for chamber access, gas connections, maintenance, and specimen handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore use, the chamber should be inspected, connected to the appropriate gas supply, conditioned according to the manufacturer's procedures, and tested for the required environmental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRelated Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories using the Sheldon Bactron III may also require \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=incubator\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory incubators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=biosafety+cabinet\u0026amp;type=product\"\u003e\u003cspan\u003ebiological safety cabinets\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=autoclave\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory autoclaves\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=laboratory+refrigerator\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory refrigerators and freezers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=microscope\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory microscopes\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange supplies used and refurbished laboratory equipment for microbiology, clinical research, biotechnology, and pharmaceutical laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSheldon Bactron III FAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the Sheldon Bactron III used for?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III is an anaerobic workstation designed for cultivating, handling, and examining oxygen-sensitive microorganisms under controlled atmospheric conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Bactron III include an incubator?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The Bactron III incorporates an integrated temperature-controlled incubation compartment for compatible anaerobic cultures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the advantage of an anaerobic chamber over anaerobic jars?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eAn anaerobic chamber allows cultures to be handled, manipulated, and incubated within a controlled atmosphere rather than relying entirely on individually sealed culture containers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Bactron III require an external gas supply?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The workstation requires an appropriate anaerobic gas mixture supplied through compatible regulators and connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the Bactron III be used for clinical microbiology?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The system is suitable for appropriate anaerobic culture procedures in clinical microbiology and related laboratory settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow are samples transferred into the chamber?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eSamples are introduced through an airlock system designed to reduce oxygen entry into the main working chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the chamber maintain completely oxygen-free conditions?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Bactron III is designed to establish anaerobic conditions, but actual oxygen levels depend on chamber integrity, gas supply, atmosphere-management components, and proper operation. Oxygen conditions should be verified before sensitive work.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat are the electrical requirements?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe equipment identification label specifies 120V, 9.0A, 50\/60Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eIs this the same as the current Sheldon Bactron 300?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eNo. The Bactron III is an earlier-generation model. Although the two systems share the general purpose of anaerobic microbiology, their dimensions, controls, and accessories should not be assumed identical.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the refurbished Bactron III include a warranty?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. American Instrument Exchange includes a 90-day warranty on refurbished equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eAre gas regulators and other accessories included?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe included gas regulators, tubing, sleeves, cuffs, oxygen indicators, and other accessories should be confirmed with American Instrument Exchange before purchase.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sheldon","offers":[{"title":"Default Title","offer_id":50994963054640,"sku":"2733B GLOVE BOX","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0104b.jpg?v=1793718134","url":"https:\/\/www.americaninstrument.com\/products\/sheldon-manufacturing-bactron-iii-anaerobic-chamber","provider":"American Instrument Exchange","version":"1.0","type":"link"}