{"product_id":"smc-hecr002-a5n-thermoelectric-peltier-chiller","title":"SMC HECR002-A5N Thermoelectric Peltier Chiller","description":"\u003ch2\u003eSMC HECR002-A5N Thermoelectric Peltier Chiller\u003c\/h2\u003e\n\u003cp\u003eThe SMC HECR002-A5N Thermoelectric Peltier Chiller is a compact rack-mount temperature control system designed to provide precise cooling and heating for laboratory instruments, analytical equipment, laser systems, semiconductor manufacturing, medical devices, and industrial process applications. Utilizing thermoelectric (Peltier) technology instead of a traditional compressor, the HECR002-A5N delivers exceptionally stable temperature control without refrigerants, vibration, or compressor noise. This refurbished SMC HECR002-A5N from American Instrument Exchange offers a cost-effective solution for laboratories and industrial facilities requiring reliable recirculating temperature control with outstanding temperature stability.\u003c\/p\u003e\n\u003ch3\u003eSMC HECR002-A5N Thermoelectric Peltier Chiller Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSMC HECR002-A5N thermoelectric chiller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir-cooled Peltier (thermoelectric) cooling system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e200-watt cooling capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack-mount 19-inch design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor-free operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefrigerant-free cooling technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeating and cooling with automatic PID control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature range from 10°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature stability of ±0.01°C to ±0.03°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated circulating pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital microprocessor controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-232C \/ RS-485 communication capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple alarm and system protection functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefurbished and tested by American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90-day warranty included from American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSMC HECR002-A5N Thermoelectric Peltier Chiller Overview\u003c\/h3\u003e\n\u003cp\u003eThe SMC HECR002-A5N is engineered for applications requiring highly stable temperature control in a compact footprint. Unlike conventional compressor-based chillers, the HECR002-A5N uses solid-state Peltier thermoelectric modules that provide precise heating and cooling without refrigerants or mechanical compressors. This design eliminates vibration, reduces maintenance requirements, and allows extremely accurate temperature regulation for sensitive laboratory and manufacturing equipment. The integrated PID controller automatically transitions between heating and cooling modes to maintain stable circulating fluid temperature despite changing process loads. Its 19-inch rack-mount design allows efficient installation in equipment racks and process cabinets where space is limited.\u003c\/p\u003e\n\u003ch3\u003eCommon Applications for the SMC HECR002-A5N Thermoelectric Peltier Chiller\u003c\/h3\u003e\n\u003cp\u003eThe SMC HECR002-A5N is commonly used for laser cooling, semiconductor manufacturing equipment, analytical instrumentation, medical diagnostic systems, laboratory reactors, microscopy systems, spectroscopy instruments, imaging equipment, precision manufacturing, environmental testing, electronics cooling, and other applications requiring stable recirculating temperature control. The compressor-free thermoelectric design is particularly advantageous where vibration or acoustic noise must be minimized.\u003c\/p\u003e\n\u003ch3\u003eIdeal Lab Types for the SMC HECR002-A5N Thermoelectric Peltier Chiller\u003c\/h3\u003e\n\u003cp\u003eThis thermoelectric chiller is well suited for biotechnology companies, pharmaceutical manufacturers, analytical chemistry laboratories, semiconductor fabrication facilities, university research laboratories, medical device manufacturers, environmental testing laboratories, and industrial research and development departments. Laboratories utilizing laser systems, analytical instruments, reactors, microscopes, chromatography equipment, and precision manufacturing tools frequently incorporate thermoelectric chillers into temperature-sensitive workflows.\u003c\/p\u003e\n\u003ch3\u003eSMC HECR002-A5N Thermoelectric Peltier Chiller Key Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHECR002-A5N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eThermoelectric Recirculating Chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Technology\u003c\/td\u003e\n\u003ctd\u003ePeltier Thermoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e200 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eAir-Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e10°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e±0.01°C to ±0.03°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic Heating\/Cooling PID Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Capacity\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.8 GPM (3.0 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eRS-232C \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCirculating Fluid\u003c\/td\u003e\n\u003ctd\u003eWater or 20% Ethylene Glycol Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1\" W × 11.8\" D × 6.9\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 31 lbs (14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSpecifications compiled from SMC manufacturer literature, distributor technical references, and American Instrument Exchange product information.\u003c\/p\u003e\n\u003ch3\u003eRefurbishment and Testing Process\u003c\/h3\u003e\n\u003cp\u003eAt American Instrument Exchange, each refurbished thermoelectric chiller is inspected and evaluated by our technicians prior to shipment. Testing procedures may include verification of cooling and heating performance, pump operation, temperature stability, controller functionality, alarm system operation, communication interface testing, electrical safety inspection, and general operational evaluation. Components showing excessive wear are serviced or replaced as needed to help ensure dependable performance. Final cleaning and inspection are completed before packaging and shipment.\u003c\/p\u003e\n\u003ch3\u003eShipping and Installation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe SMC HECR002-A5N should be installed in a standard 19-inch equipment rack or on a stable laboratory surface with adequate airflow around the air-cooled heat exchanger. Buyers should verify electrical compatibility and ensure that compatible circulating fluid is used according to the manufacturer's recommendations. Proper ventilation should be maintained around the intake and exhaust openings to maximize cooling performance. The unit is carefully packaged to protect the controller, circulating pump, heat exchanger, and electronic components during shipment.\u003c\/p\u003e\n\u003ch3\u003eRelated Laboratory Equipment\u003c\/h3\u003e\n\u003cp\u003eLaboratories purchasing thermoelectric chillers often also require laboratory reactors, analytical instruments, recirculating water baths, incubators, centrifuges, laboratory freezers, and analytical balances. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support analytical chemistry, biotechnology, semiconductor manufacturing, pharmaceutical development, and industrial research workflows.\u003c\/p\u003e\n\u003ch3\u003eSMC HECR002-A5N Thermoelectric Peltier Chiller Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the advantage of a Peltier chiller compared to a compressor chiller?\u003c\/h4\u003e\n\u003cp\u003ePeltier chillers use solid-state thermoelectric modules instead of compressors, providing extremely stable temperature control with low vibration, quiet operation, and no refrigerants. They are ideal for sensitive analytical and laboratory equipment.\u003c\/p\u003e\n\u003ch4\u003eWhat types of equipment can the HECR002-A5N cool?\u003c\/h4\u003e\n\u003cp\u003eThe HECR002-A5N is commonly used with lasers, analytical instruments, microscopes, semiconductor equipment, laboratory reactors, medical devices, and other equipment requiring precise recirculating temperature control.\u003c\/p\u003e\n\u003ch4\u003eCan the unit both heat and cool?\u003c\/h4\u003e\n\u003cp\u003eYes. The integrated PID controller automatically switches between heating and cooling modes to maintain the programmed circulating fluid temperature without operator intervention.\u003c\/p\u003e\n\u003ch4\u003eDoes this chiller use refrigerant?\u003c\/h4\u003e\n\u003cp\u003eNo. The HECR002-A5N uses thermoelectric Peltier modules and does not require conventional refrigerants or compressor-based refrigeration systems.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty is included?\u003c\/h4\u003e\n\u003cp\u003eThis refurbished SMC HECR002-A5N Thermoelectric Peltier Chiller includes a 90-day warranty from American Instrument Exchange.\u003c\/p\u003e","brand":"American Instrument Exchange","offers":[{"title":"Default Title","offer_id":43356402483248,"sku":"1466E CIRC","price":1650.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.americaninstrument.com\/products\/smc-hecr002-a5n-thermoelectric-peltier-chiller","provider":"American Instrument Exchange","version":"1.0","type":"link"}