{"product_id":"thermo-maxq-2000-shaker","title":"Thermo MaxQ 2000 Shaker","description":"\u003ch2\u003eThermo Scientific MaxQ 2506 Open-Air Orbital Shaker\u003c\/h2\u003e\n\u003cp\u003eThe Thermo Scientific MaxQ 2506 Open-Air Orbital Shaker is a high-capacity benchtop orbital shaker designed for reliable mixing of flasks, bottles, tubes, and microplates in laboratory research, biotechnology, pharmaceutical, environmental, and industrial applications. Featuring a durable triple-eccentric drive mechanism, digital speed control, and a large platform capable of accommodating a wide variety of accessories, the MaxQ 2506 delivers smooth, reproducible shaking performance for continuous laboratory operation. This refurbished Thermo Scientific MaxQ 2506 from American Instrument Exchange offers a cost-effective alternative to new equipment while providing the dependable performance expected from the Thermo Scientific MaxQ series.\u003c\/p\u003e\n\u003ch3\u003eThermo Scientific MaxQ 2506 Open-Air Orbital Shaker Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThermo Scientific MaxQ 2506 open-air orbital shaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-capacity benchtop orbital shaker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTriple-eccentric drive mechanism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVariable speed range from 15 to 500 RPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-inch (25 mm) orbital motion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum load capacity of 35 lbs (15.9 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital speed display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital timer with continuous operation mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge universal platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with flask clamps, tube racks, and microplate holders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance-free brushless motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefurbished and tested by American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90-day warranty included from American Instrument Exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThermo Scientific MaxQ 2506 Open-Air Orbital Shaker Overview\u003c\/h3\u003e\n\u003cp\u003eThe Thermo Scientific MaxQ 2506 is engineered to provide consistent orbital mixing across a broad range of laboratory applications. Its triple-eccentric drive system minimizes vibration while maintaining smooth orbital motion, even under heavy loads. The variable-speed controller allows users to optimize agitation for delicate cell culture work, vigorous media preparation, staining procedures, extraction protocols, and general laboratory mixing. The large platform accommodates numerous flask and bottle configurations, allowing laboratories to configure the shaker for changing workflow requirements without sacrificing stability or performance.\u003c\/p\u003e\n\u003ch3\u003eCommon Applications for the Thermo Scientific MaxQ 2506 Open-Air Orbital Shaker\u003c\/h3\u003e\n\u003cp\u003eThe MaxQ 2506 is commonly used for bacterial culture growth, yeast culture, media preparation, protein expression studies, plasmid preparation, staining and washing procedures, environmental sample preparation, chemical mixing, pharmaceutical research, and general laboratory agitation. Its wide speed range and high load capacity make it suitable for both gentle mixing applications and more vigorous shaking protocols involving multiple flasks or bottles.\u003c\/p\u003e\n\u003ch3\u003eIdeal Lab Types for the Thermo Scientific MaxQ 2506 Open-Air Orbital Shaker\u003c\/h3\u003e\n\u003cp\u003eThis orbital shaker is well suited for biotechnology companies, pharmaceutical manufacturers, microbiology laboratories, molecular biology laboratories, university research facilities, environmental testing laboratories, food and beverage laboratories, industrial quality control departments, and contract research organizations. Laboratories utilizing \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003eincubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e frequently use orbital shakers as part of routine sample preparation and cell culture workflows.\u003c\/p\u003e\n\u003ch3\u003eThermo Scientific MaxQ 2506 Open-Air Orbital Shaker Key Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eThermo Scientific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMaxQ 2506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eOpen-Air Orbital Shaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Type\u003c\/td\u003e\n\u003ctd\u003eOrbital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrbit Diameter\u003c\/td\u003e\n\u003ctd\u003e1 in. (25 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Range\u003c\/td\u003e\n\u003ctd\u003e15-500 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Control\u003c\/td\u003e\n\u003ctd\u003eDigital Microprocessor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e1 minute to 999 minutes or Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e35 lbs (15.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Mechanism\u003c\/td\u003e\n\u003ctd\u003eTriple-Eccentric Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMaintenance-Free Brushless Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Size\u003c\/td\u003e\n\u003ctd\u003e18 in. × 18 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Platform (accessories sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e120V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 18.5\" W × 22.5\" D × 8.5\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 63 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSpecifications compiled from Thermo Scientific manufacturer literature, distributor technical references, and American Instrument Exchange product information.\u003c\/p\u003e\n\u003ch3\u003eRefurbishment and Testing Process\u003c\/h3\u003e\n\u003cp\u003eAt American Instrument Exchange, each refurbished orbital shaker is inspected and evaluated by our technicians prior to shipment. Testing procedures may include speed verification throughout the operating range, drive mechanism inspection, motor performance evaluation, digital controller testing, timer functionality verification, platform inspection, and general operational testing. Components showing excessive wear are replaced or serviced as needed to help ensure dependable laboratory operation. Final cleaning and inspection are completed before packaging and shipment.\u003c\/p\u003e\n\u003ch3\u003eShipping and Installation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe Thermo Scientific MaxQ 2506 should be installed on a stable, level laboratory bench capable of supporting the shaker and its maximum operating load. Buyers should verify electrical requirements and available bench space prior to installation. The shaker should be positioned to allow adequate clearance around the platform during operation, particularly when using larger flask clamps or bottle holders. The instrument is carefully packaged to protect the drive system, electronics, and platform during shipment.\u003c\/p\u003e\n\u003ch3\u003eRelated Laboratory Equipment\u003c\/h3\u003e\n\u003cp\u003eLaboratories purchasing orbital shakers often also require \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003eincubators\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003ecentrifuges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\"\u003ebiosafety cabinets\u003c\/a\u003e, \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003elaboratory refrigerators\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003efreezers\u003c\/a\u003e. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support microbiology, molecular biology, pharmaceutical research, and biotechnology workflows.\u003c\/p\u003e\n\u003ch3\u003eThermo Scientific MaxQ 2506 Open-Air Orbital Shaker Frequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat types of vessels can be used on the MaxQ 2506?\u003c\/h4\u003e\n\u003cp\u003eThe MaxQ 2506 can accommodate Erlenmeyer flasks, media bottles, culture tubes, microplates, and other laboratory vessels when equipped with the appropriate platform accessories and clamps.\u003c\/p\u003e\n\u003ch4\u003eWhat is the advantage of the triple-eccentric drive system?\u003c\/h4\u003e\n\u003cp\u003eThe triple-eccentric drive provides smooth orbital motion while minimizing vibration, helping maintain consistent shaking performance even when operating with heavier loads or at higher speeds.\u003c\/p\u003e\n\u003ch4\u003eIs this shaker suitable for cell culture applications?\u003c\/h4\u003e\n\u003cp\u003eYes. The variable speed range and gentle orbital motion make the MaxQ 2506 suitable for suspension cell culture, bacterial culture growth, media preparation, and many other biological applications.\u003c\/p\u003e\n\u003ch4\u003eDoes this shaker include a platform?\u003c\/h4\u003e\n\u003cp\u003eThe included accessories may vary by instrument. Buyers should verify the included platform and clamps prior to purchase, as configurations can differ between systems.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty is included?\u003c\/h4\u003e\n\u003cp\u003eThis refurbished Thermo Scientific MaxQ 2506 Open-Air Orbital Shaker includes a 90-day warranty from American Instrument Exchange.\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":43356377120816,"sku":"4825FF SHAKER","price":600.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.americaninstrument.com\/products\/thermo-maxq-2000-shaker","provider":"American Instrument Exchange","version":"1.0","type":"link"}