{"product_id":"thermo-scientific-heracell-vios-160i-copper-co-incubator","title":"Thermo Scientific Heracell VIOS 160i Copper CO₂ Incubator","description":"\u003ch2\u003e\u003cspan\u003eThermo Scientific Heracell VIOS 160i Copper CO₂ Incubator – Refurbished – Cat. 51033556\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Heracell VIOS 160i CO2 incubator, catalog number 51033556, is an advanced direct-heat cell culture incubator designed for mammalian cell culture, biotechnology research, pharmaceutical development, and other applications requiring precise environmental control and exceptional contamination protection. Featuring a 165-liter (5.8 cu. ft.) chamber, 100% copper interior, IR180Si infrared CO₂ sensor, continuous HEPA air filtration, and a 180°C Steri-Run decontamination cycle, the Heracell VIOS 160i provides a highly controlled environment for sensitive biological cultures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvailable refurbished from American Instrument Exchange, the Thermo Heracell VIOS 160i offers laboratories a cost-effective alternative to purchasing a new premium CO₂ incubator. Its combination of direct-heat temperature regulation, THRIVE active airflow, advanced humidity management, and intuitive iCAN touchscreen controls makes it particularly suitable for laboratories maintaining valuable cell lines, conducting long-term experiments, or seeking enhanced protection against microbial contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis particular configuration, Thermo Scientific catalog number 51033556, is identified in the manufacturer's VIOS ordering guide as a single-chamber, 120V incubator with a copper interior and infrared CO₂ sensor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e165-liter (5.8 cu. ft.) cell culture chamber\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e100% copper interior for enhanced contamination resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect-heat temperature-control system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature range from ambient +3°C to 55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature control accuracy of approximately ±0.1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature uniformity of approximately ±0.3°C at 37°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIR180Si single-beam, dual-wavelength infrared CO₂ sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCO₂ concentration range from 1% to 20%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTHRIVE active airflow system for rapid environmental recovery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous HEPA filtration supporting ISO Class 5 air cleanliness\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSteri-Run 180°C high-temperature decontamination cycle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated, protected humidity reservoir\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelative humidity exceeding approximately 93% at 37°C under specified conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eiCAN touchscreen controller with multilingual interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic fan shutoff during door openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndependent temperature-monitoring and overtemperature protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReversible exterior door for flexible laboratory installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable perforated shelving\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUSB data output and optional analog monitoring interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact, stackable cabinet design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e120V, 50\/60 Hz electrical configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefurbished and tested by American Instrument Exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-day warranty included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eThermo Heracell VIOS 160i Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific Heracell VIOS 160i is part of the manufacturer's premium VIOS family of CO₂ incubators, developed to support demanding cell culture applications through improved environmental stability, contamination protection, and ease of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator provides approximately 165 liters of usable chamber volume, accommodating conventional tissue culture flasks, multiwell plates, Petri dishes, and other laboratory vessels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike traditional water-jacketed incubators, the VIOS 160i uses a direct-heat system that transfers heat efficiently to the chamber while avoiding the maintenance associated with a surrounding water jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe THRIVE active airflow system continuously circulates filtered, humidified air throughout the chamber, promoting consistent temperature, CO₂ concentration, and relative humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAn IR180Si infrared sensor provides accurate CO₂ measurements, while the integrated humidity reservoir helps reduce evaporation from culture media.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 100% copper interior provides an additional measure of contamination resistance through copper's natural antimicrobial properties.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator also incorporates a Steri-Run high-temperature decontamination cycle that reaches 180°C, helping reduce microbial contamination on interior chamber surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTogether, these technologies make the Heracell VIOS 160i particularly attractive for laboratories conducting sensitive cell culture experiments, maintaining valuable biological materials, or requiring reliable environmental recovery following routine door openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Heracell VIOS 160i CO2 incubator is suitable for mammalian cell culture, stem cell research, tissue engineering, biotechnology development, pharmaceutical research, and other applications requiring stable temperature, CO₂ concentration, and elevated humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAcademic research laboratories can use the incubator for maintaining established cell lines, expanding primary cultures, and conducting experiments involving cellular growth, metabolism, differentiation, and signaling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBiotechnology companies may use the VIOS 160i for recombinant protein development, antibody research, cell-based assay preparation, and other procedures involving cultured mammalian cells.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePharmaceutical laboratories can use it for drug discovery, toxicology studies, cell-based screening, and selected preclinical research applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe infrared CO₂ sensor and rapid environmental recovery are particularly useful in laboratories where incubator doors are opened frequently throughout the day.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe copper chamber, continuous HEPA filtration, and Steri-Run decontamination system also make this model attractive for contamination-sensitive workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor complete cell culture operations, the Heracell VIOS 160i can be paired with \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003e\u003cspan\u003ebiosafety cabinets\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for aseptic handling and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003e\u003cspan\u003elaboratory centrifuges\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for cell harvesting and sample preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003e\u003cspan\u003elaboratory incubators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/refrigerators\"\u003e\u003cspan\u003elaboratory refrigerators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\/-80\"\u003e\u003cspan\u003eultra-low temperature freezers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e are available from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermo Heracell VIOS 160i CO2 incubator Ideal Laboratory Environments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Heracell VIOS 160i is well suited for university research laboratories, biotechnology companies, pharmaceutical research facilities, medical research institutions, and laboratories performing routine or advanced mammalian cell culture.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts 165-liter chamber offers a practical balance between incubation capacity and laboratory footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator is particularly useful for laboratories maintaining multiple cell lines or conducting extended experiments where environmental consistency is important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe copper interior and high-temperature decontamination capability are attractive for laboratories that prioritize contamination prevention and efficient cleaning procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe VIOS 160i can also serve as a dedicated incubator for valuable or contamination-sensitive cultures, helping laboratories separate experimental workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompatible stacking arrangements allow laboratories to expand incubation capacity without requiring additional bench or floor space, provided the appropriate manufacturer-approved accessories are used.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCopper Chamber \u0026amp; Contamination Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOne of the defining features of this Heracell VIOS 160i configuration is its 100% copper interior.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCopper possesses natural antimicrobial properties that can help inhibit the survival of certain microorganisms on exposed chamber surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIn a CO₂ incubator, this provides an additional measure of contamination resistance alongside routine cleaning, HEPA filtration, and proper aseptic technique.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike conventional stainless steel interiors, copper surfaces can help reduce microbial persistence without requiring a separate antimicrobial coating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe copper chamber is designed for durability and long-term laboratory use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOver time, copper may develop a natural patina. This discoloration does not necessarily indicate damage or loss of functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning procedures should follow the manufacturer's recommendations to avoid unnecessary corrosion or damage to the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe copper interior does not eliminate the possibility of culture contamination, and laboratories should continue to use appropriate aseptic handling and disinfection procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories seeking a refurbished CO₂ incubator with enhanced contamination-control features, the copper Heracell VIOS 160i offers a compelling alternative to conventional stainless steel models.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSteri-Run 180°C High-Temperature Decontamination\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Heracell VIOS 160i incorporates the manufacturer's Steri-Run high-temperature decontamination system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSteri-Run raises the chamber temperature to approximately 180°C, providing a high-temperature treatment designed to reduce microbial contamination on interior surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific describes the system as achieving a six-log reduction in specified biological indicators under validated test conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe cycle can be performed in the assembled chamber, reducing the need to remove and separately autoclave many interior components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis simplifies routine decontamination procedures and helps reduce the labor associated with maintaining a clean incubation environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe high-temperature cycle is particularly useful for laboratories maintaining sensitive cell lines or performing extended culture experiments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Steri-Run process should be initiated only after removing cultures and any materials not approved for exposure to the decontamination temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator must be allowed to complete the cycle and return to appropriate operating conditions before cultures are reintroduced.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Steri-Run system provides a significant contamination-control advantage over older CO₂ incubators that rely entirely on manual disinfection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTHRIVE Active Airflow \u0026amp; Environmental Recovery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Heracell VIOS 160i incorporates Thermo Scientific's THRIVE active airflow system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis technology uses an internal fan to distribute filtered, humidified air throughout the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe controlled airflow promotes consistent temperature, CO₂ concentration, and relative humidity across the available shelf positions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike incubators relying primarily on natural convection, the VIOS 160i actively circulates chamber air to reduce environmental differences between sample locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific describes recovery of key environmental parameters within approximately ten minutes or less following routine door openings under specified test conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRapid recovery is particularly valuable for laboratories that access their incubators frequently throughout the day.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRepeated door openings can introduce cooler, drier laboratory air and temporarily reduce CO₂ concentration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe THRIVE system helps restore the selected conditions, reducing the duration of environmental disturbances experienced by sensitive cultures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAn automatic fan-stop function disables active circulation when the door is opened, helping minimize unnecessary air exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system also works with the integrated humidity reservoir to support efficient moisture recovery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIR180Si Infrared CO₂ Sensor\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCatalog number 51033556 incorporates Thermo Scientific's IR180Si infrared CO₂ sensor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike thermal conductivity sensors, which infer CO₂ concentration from changes in the thermal properties of the chamber atmosphere, infrared sensors measure carbon dioxide using infrared absorption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe IR180Si sensor uses a single-beam, dual-wavelength design intended to provide accurate and stable CO₂ measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis technology is particularly useful in laboratories where frequent door openings cause rapid changes in chamber temperature and humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe sensor supports CO₂ concentrations from approximately 1% to 20%, accommodating conventional mammalian cell culture and other procedures requiring controlled carbon dioxide levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccurate CO₂ regulation is important for cell culture media that use bicarbonate buffering to maintain physiological pH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChanges in CO₂ concentration can alter culture-medium pH and potentially affect cell growth, metabolism, and experimental reproducibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe VIOS 160i continuously monitors chamber CO₂ concentration and adjusts gas delivery to maintain the selected setpoint.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe iCAN touchscreen provides direct access to CO₂ settings, operating information, and relevant alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe standard catalog 51033556 configuration does not include independent oxygen regulation. Laboratories requiring hypoxic or hyperoxic control should select an appropriately equipped tri-gas configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIntegrated Humidity Reservoir \u0026amp; Evaporation Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Heracell VIOS 160i CO2 incubator incorporates a protected, directly heated humidity reservoir designed to maintain elevated relative humidity during cell culture.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer literature describes relative humidity exceeding approximately 93% at 37°C under specified operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHigh humidity helps reduce evaporation from culture media, which is particularly important during extended incubation periods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eExcessive evaporation can alter nutrient concentrations, osmolarity, and other characteristics of the culture environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike conventional incubators that use an exposed water pan, the VIOS 160i incorporates a protected reservoir designed to reduce unwanted condensation and improve humidity recovery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific describes humidity recovery up to five times faster than traditional water-pan designs under comparative test conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe directly heated reservoir works with the THRIVE airflow system to distribute humidified air throughout the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis design helps maintain a stable culture environment while reducing condensation on chamber surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe reservoir should be filled and maintained according to the manufacturer's water-quality recommendations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRoutine cleaning and water replacement remain important for contamination control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe VIOS 160i provides elevated humidity for cell culture but should not be confused with an environmental stability chamber offering independent programmable relative-humidity setpoints.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eContinuous HEPA Filtration \u0026amp; ISO Class 5 Air Quality\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Heracell VIOS 160i incorporates continuous in-chamber HEPA filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system circulates chamber air through a high-efficiency particulate air filter to reduce airborne contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific states that the system filters the chamber air volume approximately once every 60 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnder specified test conditions, the chamber can achieve ISO Class 5 particulate air cleanliness within approximately five minutes after a routine door opening.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis helps reduce the number of airborne particles that may settle on culture vessels or chamber surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HEPA filtration system works alongside the copper interior and Steri-Run decontamination cycle to provide multiple layers of contamination protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe combination is particularly valuable for laboratories maintaining valuable cell lines or conducting long-term culture experiments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHEPA filtration does not replace proper aseptic technique, routine cleaning, or appropriate handling within a biosafety cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HEPA filter should be inspected and replaced according to the manufacturer's maintenance recommendations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eiCAN Touchscreen Controller \u0026amp; Environmental Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Heracell VIOS 160i incorporates the manufacturer's iCAN touchscreen control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe door-mounted display provides access to temperature and CO₂ setpoints, operating information, alarm settings, and maintenance functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts touchscreen interface simplifies routine operation compared with older incubators that rely on multiple membrane buttons and nested menus.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system supports multiple languages, making it suitable for laboratories with diverse research teams.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe controller provides access to environmental monitoring information and helps operators identify deviations from the selected operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDual temperature probes provide additional monitoring and overtemperature protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator also incorporates USB connectivity for supported data-output functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOptional analog monitoring interfaces may be available depending on the installed configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories requiring documented environmental histories, the available communication and data-recording functions should be evaluated in relation to the installed controller and external monitoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermo Heracell VIOS 160i CO2 incubator Chamber Capacity \u0026amp; Laboratory Workflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Heracell VIOS 160i provides approximately 165 liters of chamber capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe interior measures approximately 18.5 inches wide, 22.7 inches deep, and 23.9 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer-standard configuration includes three adjustable perforated shelves, with a maximum of ten shelf positions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual shelf quantity and included accessories should be confirmed for the refurbished unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber accommodates conventional cell culture flasks, multiwell plates, Petri dishes, and other laboratory vessels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePerforated shelving supports the circulation of conditioned air throughout the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSamples should be arranged to avoid blocking airflow pathways or overcrowding individual shelves.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe exterior cabinet measures approximately 25.1 inches wide, 34.6 inches deep, and 35.4 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe compact footprint and stackable design make the VIOS 160i suitable for laboratories seeking substantial incubation capacity without dedicating excessive floor space.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermo Heracell VIOS 160i Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermo Scientific\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeracell VIOS 160i\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51033556\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect-Heat CO₂ Incubator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle chamber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e165 L (5.8 cu. ft.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient +3°C to 55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately ±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately ±0.3°C at 37°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect heat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAir Circulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTHRIVE active airflow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–20%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIR180Si infrared sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCO₂ Sensor Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-beam, dual-wavelength infrared\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOxygen Regulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot included in standard catalog configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtected, directly heated water reservoir\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than approximately 93% RH at 37°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHEPA Filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous in-chamber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAir Filtration Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately one chamber air volume per 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Air Cleanliness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISO Class 5 under specified conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDecontamination System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSteri-Run\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDecontamination Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eController\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eiCAN touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual temperature probes and overtemperature protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Manufacturer Shelves\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 adjustable, perforated shelves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Shelf Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShelves Included\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify actual included quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Dimensions (W × D × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.5\" × 22.7\" × 23.9\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Dimensions (W × D × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.1\" × 34.6\" × 35.4\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 183 lb. (83 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB; optional analog interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Door\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReversible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStacking Capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes, with compatible accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigeration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndependent Humidity Setpoint Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90-day warranty included from American Instrument Exchange\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eSpecifications compiled from Thermo Scientific manufacturer literature and distributor technical references. Actual shelf quantity, accessories, and installed options should be verified for the individual refurbished unit.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbishment \u0026amp; Testing by American Instrument Exchange\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific Heracell VIOS 160i is offered used and refurbished by American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAIE technicians inspect and evaluate refurbished CO₂ incubators to verify their suitability for continued laboratory use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe refurbishment process includes inspection of the chamber, copper interior, door gaskets, shelving, heating system, CO₂ sensor, humidity reservoir, airflow components, and electronic controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator is cleaned, and worn or malfunctioning components are repaired or replaced as necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature performance is evaluated using calibrated monitoring equipment to verify chamber accuracy and stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCO₂ concentration is independently measured to assess sensor accuracy and gas-control performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe THRIVE airflow system, HEPA filtration components, alarms, touchscreen controller, and other installed functions are inspected as applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Steri-Run decontamination system is evaluated as part of the refurbishment process when appropriate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFollowing testing and final inspection, the incubator is prepared for shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA 90-day warranty is included from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Heracell VIOS 160i should be installed on a stable, level laboratory surface with appropriate ventilation and access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator requires a suitable 120V electrical supply and regulated CO₂ gas source.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe equipment nameplate should be checked before connecting electrical power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe humidity reservoir should be filled with water meeting the manufacturer's requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, the incubator should be allowed to stabilize at the selected temperature and CO₂ concentration before sensitive cultures are introduced.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should verify operating conditions using suitable calibrated reference instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf the incubator is to be stacked with another compatible unit, manufacturer-approved stacking accessories should be used.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange can arrange appropriate shipping and assist customers in identifying compatible replacement equipment when needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermo Heracell VIOS 160i Frequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the Thermo Heracell VIOS 160i used for?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Heracell VIOS 160i is designed for mammalian cell culture, tissue culture, biotechnology research, pharmaceutical development, and other applications requiring controlled temperature, CO₂ concentration, and elevated humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the capacity of the Heracell VIOS 160i?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator provides approximately 165 liters, or 5.8 cu. ft., of chamber capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes catalog number 51033556 have a copper interior?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The Thermo Scientific VIOS ordering guide identifies catalog number 51033556 as the 120V single-chamber configuration with an infrared CO₂ sensor and 100% copper interior.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the advantage of the copper interior?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCopper possesses natural antimicrobial properties that can help reduce microbial persistence on exposed chamber surfaces. This provides an additional contamination-control measure when combined with proper cleaning and aseptic technique.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Heracell VIOS 160i have a decontamination cycle?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The incubator incorporates Thermo Scientific's Steri-Run high-temperature decontamination system, which reaches approximately 180°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the temperature range of the VIOS 160i?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator operates from approximately 3°C above ambient laboratory temperature to 55°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat type of CO₂ sensor does catalog number 51033556 use?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration incorporates the IR180Si infrared CO₂ sensor, which uses a single-beam, dual-wavelength measurement system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the VIOS 160i have HEPA filtration?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The incubator incorporates continuous in-chamber HEPA filtration designed to maintain ISO Class 5 particulate air cleanliness under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow quickly does the HEPA system restore clean air?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific states that the chamber can achieve ISO Class 5 air cleanliness within approximately five minutes following a routine door opening under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is THRIVE active airflow?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eTHRIVE is Thermo Scientific's active airflow system that distributes filtered, humidified air throughout the chamber to promote consistent temperature, CO₂ concentration, and relative humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the Heracell VIOS 160i control oxygen?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe VIOS platform offers optional oxygen-control configurations, but standard catalog number 51033556 is a CO₂ incubator without independent oxygen regulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow does the VIOS 160i maintain humidity?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe incubator uses a protected, directly heated water reservoir designed to maintain relative humidity above approximately 93% at 37°C under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow many shelves does the Heracell VIOS 160i accommodate?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer-standard configuration includes three adjustable shelves, with a maximum of ten shelf positions. The number included with an individual refurbished unit should be verified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan two Heracell VIOS 160i incubators be stacked?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. Compatible VIOS incubators can be stacked using manufacturer-approved stacking accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat electrical supply does catalog number 51033556 require?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe unit is designed for 120V, 50\/60 Hz operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eIs this Thermo Heracell VIOS 160i refurbished?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The Heracell VIOS 160i offered by American Instrument Exchange is used and refurbished. AIE technicians inspect, clean, and test the incubator to verify temperature stability, CO₂ regulation, and other installed functions. Necessary repairs are performed before shipment, and the equipment includes a 90-day warranty.\u003c\/span\u003e\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":51014891077680,"sku":"3180YY INC","price":3200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0913a.jpg?v=1793912652","url":"https:\/\/www.americaninstrument.com\/products\/thermo-scientific-heracell-vios-160i-copper-co-incubator","provider":"American Instrument Exchange","version":"1.0","type":"link"}