{"product_id":"thermo-scientific-savant-speedvac-dna130-115","title":"Thermo Scientific Savant SpeedVac DNA130-115","description":"\u003ch2\u003e\u003cspan\u003eThermo Scientific Savant SpeedVac DNA130-115 Integrated Vacuum Concentrator with RD-36 Rotor – Refurbished\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific Savant SpeedVac DNA130-115 Integrated Vacuum Concentrator is a compact centrifugal vacuum concentration system designed for efficient drying and concentration of DNA, RNA, PCR products, and other small-volume biological samples. Combining centrifugal force, controlled heating, and an integrated oil-free vacuum pump, the DNA130 provides a convenient solution for laboratories performing routine molecular biology and nucleic acid sample preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished Thermo Scientific Savant DNA130-115 from American Instrument Exchange includes an RD-36 rotor with capacity for 36 standard 1.5\/2.0 mL microcentrifuge tubes. The combination of an integrated vacuum pump and included rotor provides a convenient, space-saving concentration system without requiring a separate external vacuum pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130-115 is particularly well suited for laboratories concentrating aqueous solutions, PCR buffers, and compatible ethanol-water mixtures. Its adjustable heating system allows samples to be concentrated at ambient temperature or with controlled heat up to 65°C, providing flexibility for temperature-sensitive biological materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange professionally inspects, cleans, and tests refurbished laboratory equipment before shipment. This unit includes a 90-day warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific Savant SpeedVac DNA130-115 integrated vacuum concentrator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes RD-36 rotor for 36 × 1.5\/2.0 mL microcentrifuge tubes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in oil-free diaphragm vacuum pump\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for DNA, RNA, PCR products, and aqueous sample concentration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum rotor speed of approximately 1,600 RPM at 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUltimate vacuum specification below 10 Torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated vacuum pump capacity of 36 L\/min at 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable heating from ambient to 65°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree user-programmable operating programs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndependent heating and run timers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic, manual, and preheat operating modes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital display for temperature and timer settings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePTFE-coated aluminum vacuum chamber\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransparent acrylic lid with safety interlock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintenance-free induction drive motor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact integrated benchtop design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard 115V, 60 Hz electrical configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefurbished and tested by American Instrument Exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-day warranty included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eOverview of the Thermo Scientific Savant DNA130\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific Savant DNA130 is designed to simplify the concentration and drying of small-volume biological samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditional centrifugal vacuum concentrators often require several separate components, including the concentrator, vacuum pump, and vapor collection equipment. The DNA130 integrates the vacuum pump directly into the instrument housing, reducing the number of separate components needed for routine aqueous sample preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDuring operation, samples rotate inside the vacuum chamber while the integrated pump reduces chamber pressure. The lower pressure promotes solvent evaporation, while centrifugal force helps retain liquid and dissolved sample material within the tubes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eControlled heating can be applied to compensate for evaporative cooling and accelerate the concentration process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis combination makes the DNA130 particularly useful for laboratories handling small quantities of DNA, RNA, and other valuable biological materials where minimizing sample loss is important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith its included 36-place RD-36 rotor, this refurbished system is configured for processing multiple microcentrifuge tubes in a single run, making it suitable for repetitive nucleic acid concentration workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific Savant DNA130 is designed primarily for molecular biology and nucleic acid sample preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCommon applications include DNA concentration following extraction or purification, RNA concentration, PCR product drying, oligonucleotide preparation, concentration of aqueous buffers, ethanol removal from nucleic acid preparations, and general small-volume sample drying.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument can also support selected biochemical and biotechnology procedures involving compatible aqueous solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the DNA130 is optimized for water-based applications, it is especially useful in genomics laboratories, molecular diagnostics research, biotechnology development, academic research, and laboratories performing repetitive nucleic acid preparation procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130 is not intended as a universal solvent evaporation system. Laboratories processing aggressive organic solvents, strong acids, or other chemically demanding samples should verify compatibility and consider a concentrator designed for those applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Laboratory Environments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130-115 is well suited for molecular biology laboratories, genomics research facilities, biotechnology companies, pharmaceutical research laboratories, academic research institutions, and contract research organizations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is particularly useful for laboratories processing multiple small-volume samples where the convenience of an integrated vacuum system is more important than the flexibility of a modular concentrator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe built-in pump eliminates the need to dedicate additional bench space to a separate vacuum pump and reduces the number of external connections required for routine operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe included RD-36 rotor accommodates 36 samples per run, making this configuration useful for laboratories performing batch DNA and RNA concentration procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories replacing an older DNA130 or adding a dedicated nucleic acid concentration workstation, a refurbished instrument can provide substantial value while preserving familiar operating procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermo Scientific \/ Savant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpeedVac DNA130\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDNA130-115\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIE SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1337S CENTRI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUsed \/ Refurbished\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Centrifugal Vacuum Concentrator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrimary Applications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDNA, RNA, PCR Products, Aqueous Samples\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVacuum Pump\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Oil-Free Diaphragm Pump\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePump Head Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eETFE Diaphragms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePump Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 L\/min at 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Vacuum\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 10 Torr (13 mbar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded Rotor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRD-36\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded Rotor Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 × 1.5\/2.0 mL Microcentrifuge Tubes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Rotor Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1,600 RPM at 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient to 65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSelectable Temperature Settings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient or 35°C–65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5°C Increments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser-Defined Programs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic, Manual, Preheat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating Timer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Minute to 9 Hours 59 Minutes, or Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRun Timer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Minute to 9 Hours 59 Minutes, or Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePTFE-Coated Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Seal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilicone Rubber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLid\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransparent Acrylic with Safety Interlock\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaintenance-Free Induction\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNoise Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 65 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\"W × 25\"D × 12\"H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 86 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115V, 60 Hz, 10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA 5-15P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Ventilation Clearance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\" on All Sides\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 Days\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eSpecifications compiled from Thermo Scientific manufacturer literature, distributor technical references, and American Instrument Exchange product information. This refurbished unit includes the RD-36 rotor for 36 standard 1.5\/2.0 mL microcentrifuge tubes.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIntegrated Vacuum Pump and Concentration Technology\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe principal advantage of the DNA130 is its integrated vacuum system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike standalone concentrators that require a separate external vacuum pump, the DNA130 incorporates an oil-free diaphragm pump directly into the instrument housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe pump provides a nominal displacement of 36 liters per minute at 60 Hz and an ultimate vacuum specification below 10 Torr.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReducing chamber pressure lowers the temperature at which water and other compatible solvents evaporate, allowing samples to be concentrated without relying exclusively on elevated heat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDuring evaporation, centrifugal force helps keep sample material inside the tubes and reduces the risk of liquid loss caused by bumping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oil-free diaphragm design also eliminates routine vacuum pump oil changes and reduces maintenance requirements associated with oil-sealed vacuum pumps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlthough the vacuum pump is integrated, specialized solvent applications may still require appropriate external vapor-handling accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTemperature Control and Programmable Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific DNA130 provides adjustable chamber heating from ambient temperature to 65°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsers can select ambient operation or temperature settings between 35°C and 65°C in 5°C increments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis flexibility allows laboratories to select gentle drying conditions for sensitive biological samples or apply additional heat when faster evaporation is appropriate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument includes three user-modifiable programs that can be stored for frequently performed procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIndependent heating and run timers allow researchers to control the duration of heating separately from the overall concentration cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic and manual operating modes provide additional flexibility, while the preheat function allows the chamber to reach the selected temperature before sample processing begins.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe digital control panel displays operating parameters, and an audible alarm alerts the operator when a programmed run is complete.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese functions help laboratories establish repeatable concentration procedures for routine DNA and RNA workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIncluded RD-36 Rotor and Sample Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished Thermo Scientific Savant DNA130-115 includes an RD-36 rotor designed to accommodate 36 standard 1.5\/2.0 mL microcentrifuge tubes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 36-place configuration allows laboratories to concentrate multiple biological samples simultaneously, reducing the number of evaporation cycles required for repetitive DNA and RNA preparation procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe RD-36 rotor is particularly useful for laboratories processing nucleic acid extracts, PCR products, oligonucleotides, and other small-volume samples in standard microcentrifuge tubes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130 operates at a typical maximum rotor speed of approximately 1,600 RPM at 60 Hz. Centrifugal force helps retain samples within the tubes during vacuum evaporation, minimizing the risk of sample loss from bumping or foaming.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130 also supports additional rotor configurations for different sample formats, including 0.5 mL microcentrifuge tubes and compatible microplates.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe included RD-36 rotor makes this particular refurbished unit ready for 36-place microtube processing without requiring the separate purchase of a rotor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSolvent Compatibility and Vapor Handling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific DNA130 is optimized for concentration of water-based biological samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-supported applications include water, aqueous PCR buffers, ethanol-water mixtures, and selected ammonium hydroxide applications when appropriate vapor-neutralization accessories are installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor ammonium hydroxide applications, Thermo Scientific specifies the use of an external ammonia post-trap and neutralizing solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe integrated vacuum pump should not be exposed to solvents or chemical vapors outside the manufacturer's approved operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOptional chemical traps and cartridges are available for certain specialized applications, including vapor neutralization and collection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese accessories are not assumed to be included with this refurbished instrument.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories requiring extensive organic solvent evaporation should evaluate whether a more chemically resistant SpeedVac system would be appropriate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbishment and Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange technicians inspect and evaluate refurbished vacuum concentrators before shipment to verify proper mechanical and electrical operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTesting includes evaluation of the integrated vacuum pump, chamber vacuum performance, rotation mechanism, heating system, electronic controls, lid safety mechanisms, and overall operating condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe included RD-36 rotor is inspected for wear, damage, and proper fit within the instrument. The rotor and concentrator are evaluated together to verify their operation as a complete system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe vacuum chamber, seals, lid, and accessible vacuum components are inspected for wear, damage, and signs of chemical exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the DNA130 incorporates an internal vacuum pump, evaluation of pump operation is an important part of the refurbishment process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument is cleaned and prepared for shipment after testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished Thermo Scientific Savant DNA130-115 includes a 90-day warranty from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Thermo Scientific DNA130-115 measures approximately 11.5 inches wide × 25 inches deep × 12 inches high and weighs approximately 86 pounds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts integrated design eliminates the need to allocate separate bench space for an external vacuum pump, although the instrument requires adequate clearance for ventilation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThermo Scientific recommends approximately 3 inches of clearance around the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130-115 operates on 115V, 60 Hz electrical service and draws approximately 10 amps. It uses a standard NEMA 5-15P plug.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe concentrator should be positioned on a sturdy, level laboratory bench with adequate access to the lid and control panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange prepares refurbished laboratory equipment for secure shipment, protecting the chamber, lid, electronic controls, and internal mechanical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRelated Laboratory Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange offers a selection of \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/centrifuges\"\u003e\u003cspan\u003eused and refurbished laboratory centrifuges\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, including centrifugal vacuum concentrators, microcentrifuges, refrigerated benchtop centrifuges, and high-speed centrifuges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories performing DNA and RNA sample preparation may also be interested in \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/freezers-ice-makers\"\u003e\u003cspan\u003elaboratory freezers and ultra-low freezers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/incubators\"\u003e\u003cspan\u003elaboratory incubators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/bio-safety-cabinets\/biocab\"\u003e\u003cspan\u003ebiosafety cabinets\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratories requiring modular vacuum evaporation equipment, American Instrument Exchange also offers \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/collections\/vacuum-pumps\"\u003e\u003cspan\u003elaboratory vacuum pumps\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e and other sample preparation equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eService and Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange provides diagnostic evaluation, preventative maintenance, and repair support for SpeedVac concentrators and other laboratory equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor a Thermo Scientific DNA130, service evaluation may include the integrated vacuum pump, diaphragm condition, chamber seals, heating system, drive motor, electronic controls, and lid safety mechanisms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOur technicians can help laboratories determine whether repair or replacement with another refurbished concentrator is the more economical solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermo Scientific Savant SpeedVac DNA130-115 Frequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eDoes this DNA130-115 include a vacuum pump?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The Thermo Scientific DNA130-115 has a built-in oil-free diaphragm vacuum pump. A separate external vacuum pump is not required for normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat rotor is included with this refurbished DNA130?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished DNA130-115 includes the Thermo Scientific RD-36 rotor, designed to accommodate 36 standard 1.5\/2.0 mL microcentrifuge tubes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow many samples can the included RD-36 rotor accommodate?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe RD-36 rotor accommodates up to 36 standard 1.5\/2.0 mL microcentrifuge tubes in a single concentration cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the maximum vacuum level of the DNA130?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's specified ultimate vacuum is less than 10 Torr, equivalent to approximately 13 mbar or 1.3 kPa.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the DNA130 be used for DNA and RNA concentration?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The DNA130 is specifically designed for concentrating and drying DNA, RNA, PCR products, and other compatible aqueous biological samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the maximum heating temperature?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130 provides selectable chamber heating up to 65°C, with settings from 35°C to 65°C in 5°C increments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the DNA130 process ethanol-containing samples?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. Thermo Scientific lists ethanol-water mixtures among the supported solvent combinations. Laboratories should verify that their specific solvent concentrations and operating conditions are compatible.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the DNA130 process ammonium hydroxide?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes, with the appropriate external ammonia post-trap and neutralizing solution specified by Thermo Scientific. These accessories are not included unless specifically listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the difference between the DNA130 and SPD120?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130 is an integrated vacuum concentrator with a built-in oil-free pump, primarily intended for aqueous biological samples. The SPD120 is a standalone concentrator that requires an external vacuum pump and is designed for a broader range of compatible laboratory solvents.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the DNA130 require a separate refrigerated vapor trap?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eA separate refrigerated vapor trap is not required for the manufacturer's standard aqueous applications. However, specialized solvents or chemical vapors may require appropriate external trapping or neutralization accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat electrical service is required?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe DNA130-115 operates on 115V, 60 Hz electrical service and draws approximately 10 amps. It uses a standard NEMA 5-15P plug.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhy purchase a refurbished Thermo Scientific Savant DNA130?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eA refurbished DNA130 provides integrated vacuum concentration capabilities at a lower acquisition cost than a new instrument. With its built-in pump and included RD-36 rotor, this unit provides a convenient configuration for processing up to 36 microcentrifuge tubes without requiring a separate external vacuum pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished unit includes a 90-day warranty from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e","brand":"Thermo","offers":[{"title":"Default Title","offer_id":51019860377648,"sku":"1337S CENTRI","price":4950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1228\/9072\/files\/DSC_0174b.jpg?v=1793980037","url":"https:\/\/www.americaninstrument.com\/products\/thermo-scientific-savant-speedvac-dna130-115","provider":"American Instrument Exchange","version":"1.0","type":"link"}