{"product_id":"vwr-89511-412-forced-air-laboratory-oven","title":"VWR 89511-412 Forced Air Laboratory Oven","description":"\u003ch2\u003e\u003cspan\u003eVWR 89511-412 Forced Air Laboratory Oven – Used and Refurbished\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 Forced Air Laboratory Oven is a precision temperature-controlled drying and heating oven designed for laboratory applications requiring consistent heat distribution, rapid temperature recovery, and dependable thermal processing. Featuring a 104-liter (3.7 cu. ft.) stainless steel chamber, operating temperatures from 50°C to 250°C, and a microprocessor-based PID temperature controller, this VWR forced convection oven provides reliable performance for research, pharmaceutical, biotechnology, and industrial laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike conventional gravity convection ovens, the VWR 89511-412 uses mechanically circulated heated air to distribute thermal energy throughout the chamber. This forced-air design promotes faster drying, improved temperature uniformity, and more consistent heating of compatible laboratory materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven incorporates adjustable shelving, a digital temperature controller with integrated timer, independent overtemperature protection, and dual-sensor safety features. Its stainless steel interior with rounded corners facilitates cleaning and helps maintain a durable working environment for routine laboratory applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis VWR 89511-412 Forced Air Oven is offered used and refurbished by American Instrument Exchange. Our experienced technicians inspect and test laboratory heating equipment before shipment, providing customers with substantial savings compared to purchasing new.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA 90-day warranty is included with this refurbished laboratory oven.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVWR forced air laboratory drying oven, catalog number 89511-412\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e104-liter (3.7 cu. ft.) stainless steel chamber\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature operating range of 50–250°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eForced-air circulation for rapid and uniform heating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMicroprocessor-based PID temperature controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital temperature setting with 0.1°C resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-rated temperature fluctuation of ±0.4°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature uniformity of ±3.5°C under specified test conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApproximately 18-minute heat-up time under manufacturer test conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApproximately 3-minute temperature recovery time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated timer for controlled heating procedures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndependent overtemperature protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual-sensor safety features\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStainless steel interior with rounded corners for easier cleaning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable wire shelves for flexible sample placement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e120V electrical configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ecCSAus-certified model design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefurbished and tested by American Instrument Exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e90-day warranty included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 is a laboratory forced convection oven developed for applications requiring controlled heating, drying, and thermal conditioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts 104-liter chamber provides substantial usable space for sample containers, laboratory glassware, metal components, and other compatible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven uses an internal circulation fan to distribute heated air throughout the chamber, helping reduce temperature differences between locations and promoting consistent thermal exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis approach is particularly beneficial when processing multiple samples simultaneously or performing procedures that require repeatable temperature conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe integrated PID controller continuously adjusts heating output to maintain the selected temperature, while the timer provides convenient control over routine laboratory heating procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe combination of chamber capacity, temperature performance, and straightforward operation makes the VWR 89511-412 suitable for a wide range of laboratory drying and heat-treatment applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 is used for drying laboratory glassware, removing moisture from compatible samples, conditioning materials, heating laboratory components, and performing controlled thermal treatments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional applications include drying powders and granules, preparing analytical samples, evaluating material stability, curing compatible coatings and resins, and conducting research involving elevated-temperature exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven is also useful for industrial quality-control testing, materials science research, pharmaceutical development, and general laboratory drying procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll samples and materials must be compatible with the oven's temperature range, forced-air environment, and safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVWR International\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e89511-412\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEquipment Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air Laboratory Oven\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e104 L (3.7 cu. ft.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–250°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Setting Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Fluctuation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.4°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±3.5°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUniformity Test Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Rating Based on 27 Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeat-Up Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 18 Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Recovery Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 3 Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroprocessor-Based PID\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTimer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAir Circulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanically Forced Convection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChamber Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.3 in. (46.5 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 in. (36.8 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterior Height\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.9 in. (60.7 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.2 in. (64.0 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.2 in. (64.0 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExterior Height\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32.3 in. (82.0 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShelving\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Wire Shelves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Safety\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvertemperature Protection and Dual-Sensor Safety\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerify Unit Nameplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 147.7 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ecCSAus-Certified Model Design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStand and Casters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional; Not Assumed Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUsed \/ Refurbished\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 Days\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eSpecifications are based on VWR manufacturer documentation for catalog number 89511-412. Temperature uniformity, fluctuation, heat-up time, and recovery time represent manufacturer-rated performance under defined test conditions. Actual performance depends on chamber loading, operating temperature, ambient conditions, and equipment condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Laboratory Types\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 is well suited to pharmaceutical research laboratories, biotechnology facilities, analytical chemistry departments, academic research institutions, materials science laboratories, industrial quality-control facilities, and environmental testing laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts 3.7 cu. ft. capacity makes it particularly useful for laboratories requiring a mid-sized drying oven capable of processing multiple samples or larger laboratory components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eForced Air Circulation and Drying Performance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe primary advantage of the VWR 89511-412 is its forced-air convection system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAn internal fan circulates heated air throughout the chamber, promoting heat transfer between the air and the materials being processed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompared with gravity convection ovens, which rely primarily on natural air movement, forced-air systems can provide faster drying and more consistent temperature distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAir circulation also helps remove moisture from exposed sample surfaces, making the oven useful for drying compatible glassware, containers, powders, and laboratory materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDrying efficiency depends on sample geometry, moisture content, loading arrangement, and the selected temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTemperature Uniformity and Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 is designed to provide consistent chamber temperatures during laboratory heating procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer specifies temperature fluctuation of approximately ±0.4°C and temperature uniformity of ±3.5°C under defined testing conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature fluctuation describes changes in temperature over time at a measurement location, while uniformity describes differences between locations within the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's uniformity specification is based on measurements from 27 sensors distributed throughout the chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese performance characteristics are particularly important for laboratories performing material conditioning, sample drying, and repeatable thermal treatments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual temperature performance should be evaluated under the conditions relevant to the laboratory's intended applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRapid Heat-Up and Temperature Recovery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR forced-air design supports efficient heating and recovery following door openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer lists an approximately 18-minute heat-up time and a 3-minute recovery time under specified testing conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRapid temperature recovery is useful when laboratory personnel must load or unload samples during routine operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven's heating system and forced-air circulation work together to restore the selected chamber temperature after temporary disturbances.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual recovery times vary with chamber loading, operating temperature, ambient conditions, and the duration of door openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePID Temperature Controller\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 incorporates a microprocessor-based proportional-integral-derivative (PID) temperature controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePID control continuously adjusts heating output to reduce deviations between the selected temperature and measured chamber temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis helps maintain stable operating conditions and reduces unnecessary temperature fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe digital interface allows operators to select temperatures with 0.1°C setting resolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis resolution describes the controller's adjustment increment and should not be confused with absolute temperature accuracy or chamber uniformity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIntegrated Timer and Process Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe oven includes an integrated timer to support routine laboratory heating and drying procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTimed operation is useful for applications requiring a defined heating interval after the desired operating conditions have been established.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories can use the timer in conjunction with the temperature controller to develop consistent procedures for compatible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe timer's exact operating modes should be confirmed against the installed controller and manufacturer instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOvertemperature Protection and Safety Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 incorporates independent overtemperature protection and dual-sensor safety features.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese systems are intended to help protect the oven and its contents from excessive temperatures resulting from certain operating faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer also identifies cCSAus certification for this oven series.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe safety features should be inspected during refurbishment and operated according to the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven is intended for compatible nonhazardous drying and heating applications. It should not be used for processing flammable solvents, explosive materials, or substances that can generate hazardous vapors unless the manufacturer expressly approves the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStainless Steel Chamber and Adjustable Shelving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 features a stainless steel interior designed for durability and routine laboratory cleaning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRounded interior corners help reduce areas where residues and debris can accumulate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable wire shelves allow operators to configure the chamber for different sample heights and loading requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProper spacing between samples is important for maintaining effective air circulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOverloading the shelves or blocking air passages can reduce heating uniformity and increase drying time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe exact number of shelves included with the refurbished oven should be confirmed before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eVWR Forced Air Oven vs. Gravity Convection Oven\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eForced-air and gravity convection ovens are designed for different laboratory heating requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 uses mechanical air circulation to promote faster heat transfer and more uniform chamber conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGravity convection ovens rely on natural air movement and may be preferred for certain delicate materials that should not be exposed to continuous airflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor routine drying, heat treatment, and material conditioning, forced-air circulation often provides advantages in processing speed and temperature consistency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should select the appropriate oven type based on sample sensitivity, drying requirements, and operating temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eEnergy Efficiency and Operating Considerations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 uses controlled electrical heating and chamber insulation to maintain the selected operating temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts PID controller regulates heating output as needed rather than applying maximum heat continuously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEfficient chamber loading and minimizing unnecessary door openings can help reduce energy consumption and improve processing consistency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven's actual electrical consumption depends on operating temperature, ambient conditions, loading, and heating duration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should confirm the individual unit's current and power requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRefurbishment and Testing by American Instrument Exchange\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange inspects, tests, and reconditions used laboratory ovens before shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor the VWR 89511-412, relevant testing includes evaluating the heating system, verifying temperature controller operation, inspecting the circulation fan, and checking the timer and safety controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber, door gasket, shelving, electrical connections, and internal air passages should also be inspected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature performance can be evaluated using independent calibrated measurement equipment to verify heating operation and stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCustomers requiring documented temperature uniformity testing, calibration records, or confirmation of particular accessories should discuss these requirements with AIE before purchasing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis refurbished VWR forced air oven includes a 90-day warranty from American Instrument Exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 measures approximately 25.2 inches wide, 25.2 inches deep, and 32.3 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer lists a shipping weight of approximately 147.7 pounds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe oven requires a stable, heat-resistant supporting surface or an appropriate manufacturer-compatible stand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation requires suitable 120V electrical service, adequate ventilation, and appropriate clearance around the cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's operating instructions should be consulted for minimum side, rear, and overhead clearances.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOptional stands and casters are available for this oven family but should not be assumed included with the refurbished unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore operation, laboratories should inspect the interior, confirm the circulation fan operates correctly, and verify that the temperature controller and overtemperature protection function as intended.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRelated Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories using the VWR 89511-412 may also require \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=laboratory+oven\u0026amp;type=product\"\u003e\u003cspan\u003eother laboratory drying ovens\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=vacuum+oven\u0026amp;type=product\"\u003e\u003cspan\u003evacuum ovens\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=incubator\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory incubators\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=water+bath\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory water baths\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/www.americaninstrument.com\/search?q=glassware+washer\u0026amp;type=product\"\u003e\u003cspan\u003elaboratory glassware washers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Instrument Exchange supplies used and refurbished laboratory heating, drying, and temperature-control equipment for pharmaceutical, biotechnology, academic, and industrial laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eVWR 89511-412 Forced Air Oven FAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the VWR 89511-412 used for?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe VWR 89511-412 is a forced-air laboratory oven used for drying compatible samples, removing moisture, heating laboratory materials, and performing controlled thermal treatments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the chamber capacity?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe oven has a 104-liter chamber, equivalent to approximately 3.7 cubic feet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the temperature range?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer specifies an operating temperature range of 50–250°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the advantage of forced-air circulation?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eForced-air circulation promotes faster heat transfer, more consistent chamber temperatures, and improved moisture removal compared with conventional gravity convection heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the temperature uniformity?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eVWR specifies temperature uniformity of approximately ±3.5°C under defined manufacturer testing conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the oven have a digital temperature controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The 89511-412 incorporates a microprocessor-based PID temperature controller with 0.1°C setting resolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the oven have a timer?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. The oven includes an integrated timer for laboratory heating and drying procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eHow quickly does the oven heat up?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer lists an approximately 18-minute heat-up time under specified test conditions. Actual heat-up time depends on the selected temperature and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat are the interior dimensions?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe chamber measures approximately 18.3 inches wide, 14.5 inches deep, and 23.9 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat electrical service does the oven require?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer specifies 120V electrical service. The exact current and frequency requirements should be verified on the individual unit's nameplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the VWR 89511-412 be used to dry flammable solvents?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eNo. This standard forced-air laboratory oven should not be used to dry materials that release flammable or explosive vapors unless the manufacturer specifically approves the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eAre shelves included?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer supplies adjustable wire shelves with this oven series. The number and condition of shelves included with the refurbished unit should be confirmed before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eDoes the refurbished oven include a warranty?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eYes. American Instrument Exchange includes a 90-day warranty on refurbished laboratory equipment.\u003c\/span\u003e\u003c\/p\u003e","brand":"VWR","offers":[{"title":"Default Title","offer_id":51124601684016,"sku":"3731C OVEN","price":1950.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/www.americaninstrument.com\/products\/vwr-89511-412-forced-air-laboratory-oven","provider":"American Instrument Exchange","version":"1.0","type":"link"}