Refurbished Biological Safety Cabinets

Extensive Selection of Refurbished Biological Safety Cabinets

We offer an extensive selection of Refurbished Biological Safety Cabinets from various manufacturers, including The Baker Company, Nuaire, Labconco, Thermo Scientific, and others. Notably, you can save up to 70% off the price of comparable new equipment.

Click here to view our current stock of bio hoods

Quality Assurance and Comprehensive Inspections

However, lower cost does not equate to lower quality. Our reconditioned biological safety cabinets come with new HEPA filters installed by our skilled technicians. Each cabinet undergoes a complete inspection and performance review, which includes inflow and downflow velocity measurements, along with HEPA filter integrity testing. This ensures the cabinet meets NSF-49, OSHA, and the manufacturer’s operational specifications. Additionally, we provide decontamination documents and copies of test records prior to shipping. American Instrument Exchange also offers a 90-day warranty on all bio hoods and filters.

Understanding Biological Safety Cabinets

Biological safety cabinets, also known as biosafety cabinets, BSCs, or bio hoods, are designed to provide three essential levels of protection. First, they protect personnel from harmful agents inside the cabinet. Second, they safeguard products to avoid contamination during work, experiments, or processes. Finally, they protect the immediate environment from contaminants contained within the cabinet. These three levels are designated as Class I, Class II, and Class III, respectively.

Reliable Shipping and Service

Most of the Refurbished Biological Safety Cabinets shown on our website is in stock and ready for immediate shipping. We ship orders from our 30,000-square-foot warehouse in Haverhill, MA. Our reconditioned lab equipment supports a variety of laboratories, including biotech, biomedical, medical research, chemical, pharmaceutical, and university and hospital research labs. Since 1969, we have been a reliable source for used laboratory and scientific equipment.

NSF Classification Description
A1 (Class II, Type A) 70% air recirculated, 30% exhaust.
75 fpm intake 
A2 (Class II, Type A/B3) 70% air recirculated, 30% exhaust.
100 fpm intake
B1 (Class II, Type B1) 40% air recirculated; 60% exhausted to duct/external.
100 fpm intake 
B2 (Class II, Type B2)  0% air recirculated; 100% exhausted to duct/external.
100 fpm intake 

Contact us today for pricing and information on selecting a refurbished biological safety cabinet for your lab!