The Huber Unistat Tango is a high-performance dynamic temperature control system designed for precise heating and cooling of externally connected laboratory equipment. With an operating temperature range of -45°C to +200°C, temperature stability of approximately 0.02 K at -10°C, and a powerful circulation pump capable of delivering up to 55 L/min, the Unistat Tango is particularly well suited for demanding reactor temperature control and process-development applications.
Available used and refurbished from American Instrument Exchange, this Huber Unistat Tango, model UC012TW, provides rapid temperature changes and precise process control without relying on a conventional thermoregulated bath. Its hydraulically sealed design, low fluid volume, powerful circulation system, and programmable electronic controller make it an excellent choice for laboratories working with jacketed reactors and other externally temperature-controlled systems. A 90-day warranty is included.
Wide -45°C to +200°C operating temperature range
Temperature stability of approximately 0.02 K at -10°C
Maximum pressure-pump flow rate of 55 L/min
Dynamic temperature control optimized for external applications
Low 1.5 L minimum filling volume
2.8 L expansion volume
Hydraulically sealed temperature-control circuit
Programmable Unistat electronic controller
Safety monitoring for continuous operation
Used, refurbished, and tested by American Instrument Exchange
90-day warranty included
The Huber Unistat Tango differs significantly from a conventional refrigerated circulating water bath. Rather than maintaining a large open bath of temperature-controlled fluid, the Unistat system uses a relatively small fluid volume and an expansion vessel to provide rapid and precise temperature control to externally connected equipment.
This design is particularly effective for controlling jacketed research reactors, where the objective is to change and maintain the temperature of a process as quickly and accurately as possible. Reducing the internal volume that must be heated or cooled allows the Tango to respond rapidly to changing process conditions while its powerful circulation pump transfers thermal energy between the Unistat and the connected application.
The hydraulically sealed system also helps protect temperature-control fluid from unnecessary exposure to the surrounding atmosphere. This can reduce fluid loss through vaporization and help limit oxidation and moisture absorption during extended operation.
| Specification | Details |
|---|---|
| Manufacturer | Huber |
| Model | Unistat Tango UC012TW |
| Equipment Type | Dynamic temperature control system / circulation thermostat |
| Temperature Range | -45°C to +200°C |
| Temperature Stability | Approximately 0.02 K at -10°C |
| Minimum Filling Volume | 1.5 L |
| Expansion Volume | 2.8 L |
| Maximum Pump Flow | 55 L/min |
| Circulation Type | Pressure pump |
| Controller | Unistat electronic controller |
| Dimensions | 16.75 in. W × 12.67 in. D × 24.75 in. H |
| Electrical Requirements | 230 VAC, 50 Hz, 16 A |
| Application Type | External temperature control |
| Warranty | 90 days |
The Huber Unistat Tango is especially well suited for precise temperature control of jacketed laboratory reactors used in chemical synthesis, pharmaceutical development, process chemistry, scale-up studies, and materials research. The combination of rapid heating and cooling, high circulation rates, and precise temperature control allows researchers to reproduce demanding process conditions while minimizing temperature overshoot and lengthy stabilization periods.
Other applications can include temperature control of reaction vessels, process equipment, analytical systems, test fixtures, and other externally connected laboratory apparatus requiring controlled heating and cooling.
Because the Unistat Tango is designed as a dynamic temperature control system rather than a conventional open circulating bath, it is particularly valuable when the temperature of an external process—not an internal reservoir—is the primary concern.
The Unistat Tango is a strong fit for pharmaceutical and biopharmaceutical process-development laboratories, chemical research facilities, process chemistry groups, materials-science laboratories, industrial R&D facilities, pilot laboratories, academic chemistry departments, and other research environments working with temperature-controlled reactions.
It is especially useful for laboratories operating jacketed glass reactors where rapid thermal response, precise control, and reliable circulation are important to experimental reproducibility.
Dynamic temperature control is the defining capability of the Huber Unistat platform. Instead of relying on a large thermoregulated bath, the Tango minimizes the quantity of circulating fluid within the temperature-control system. This allows heating and refrigeration capacity to act more directly on the external process.
The AIE inventory unit is specified for operation from -45°C to +200°C, providing a broad working range for both sub-ambient and elevated-temperature processes. Temperature stability is approximately 0.02 K at -10°C.
For reactor applications, actual process performance also depends on factors beyond the circulator itself. Reactor volume, jacket design, heat-transfer fluid, circulation rate, hose length, insulation, process heat generation, and ambient conditions can all influence heating and cooling rates.
The Unistat Tango provides a maximum pump flow rate of approximately 55 L/min, allowing substantial circulation through compatible external equipment. Strong circulation promotes efficient heat transfer between the temperature-control fluid and the external process while helping minimize temperature differences throughout the circulation loop.
The system's pump is designed specifically for external temperature-control applications such as jacketed reactors. Actual flow through an installed system will depend on the resistance of the reactor jacket, tubing diameter and length, fittings, temperature-control fluid, viscosity, and other hydraulic restrictions.
The Unistat design also incorporates soft-start pump operation. This is particularly useful when connecting the system to delicate glass reactors because circulation can be established without immediately subjecting the reactor jacket to maximum pump output.
This used Huber Unistat Tango is refurbished and tested by American Instrument Exchange before shipment. Our technicians inspect the refrigeration, heating, circulation, temperature-control, electrical, and user-interface systems and operate the unit to confirm proper functionality.
Because the Tango provides both heating and cooling, AIE performs extended testing at both ends of the operating range when evaluating the system. Temperature-controlled equipment is tested using appropriate temperature-measurement equipment, and pump operation and fluid circulation are evaluated as part of the inspection process.
If your laboratory intends to use the Tango under specific operating conditions, contact American Instrument Exchange before shipment. When practical, our technicians can attempt to simulate your intended conditions during final testing.
A 90-day warranty is included with this refurbished Huber temperature control system.
When selecting a dynamic temperature control system for a laboratory reactor, buyers should consider more than the circulator's published minimum and maximum temperatures. Reactor volume, required heating and cooling rates, process heat load, circulation requirements, jacket configuration, temperature-control fluid, and electrical requirements can all influence performance.
The Huber Unistat Tango is particularly well suited for applications where rapid response and precise external process control are more important than having a conventional open temperature-controlled bath. Its low internal fluid volume and high-flow circulation system are designed to efficiently transfer heating and cooling capacity to an external process.
For laboratories primarily incubating samples in a controlled reservoir, a conventional circulating water bath may be more appropriate. For reactor chemistry and process-development work, however, a dynamic temperature control system such as the Unistat Tango offers significant advantages.
American Instrument Exchange can help compare available used and refurbished circulators and temperature control systems based on reactor size, target temperature, thermal load, circulation requirements, and application.
American Instrument Exchange stocks a variety of laboratory circulators for heating, cooling, and external process temperature control. Laboratories using a Huber Unistat may also require reactors and fermenters, evaporators and extractors, laboratory water baths, or other refurbished laboratory equipment for chemical synthesis and process-development applications.
This Huber Unistat Tango UC012TW is specified for an operating temperature range of -45°C to +200°C, allowing it to provide both sub-ambient cooling and elevated-temperature process control.
A dynamic temperature control system is designed primarily to rapidly heat, cool, and stabilize an external process rather than maintain a large internal bath at a fixed temperature. This makes systems such as the Unistat Tango particularly useful for controlling jacketed laboratory reactors.
Yes. Precise temperature control of research reactors is one of the primary applications for the Unistat Tango. Its high circulation rate and dynamic heating and cooling capabilities make it particularly well suited for jacketed reactor systems.
The Tango provides a maximum circulation flow rate of approximately 55 L/min. Actual flow through a reactor or other external system will depend on tubing, fittings, fluid viscosity, reactor-jacket resistance, and other installation factors.
The Unistat design uses an expansion vessel and relatively low internal fluid volume instead of a conventional thermoregulated bath. Reducing the quantity of fluid that must be heated or cooled helps the system respond more quickly to changes in process temperature.
Yes. The Unistat Tango is a heating and refrigerated dynamic temperature control system. This allows a single unit to move a connected process through both below-ambient and elevated-temperature conditions.
Yes. This used Huber Unistat Tango is refurbished and tested by American Instrument Exchange and includes a 90-day warranty.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.