Nuaire ALLERGARD NU620-400 ATS
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Nuaire AllerGard NU-620-400 Animal Transfer Station is designed to provide personnel, animal, and environmental protection for laboratory animal handling procedures requiring contamination-controlled airflow and ergonomic open-access operation. Commonly used for cage changing, animal transfer procedures, bedding changes, vivarium workflows, pharmaceutical research, and biotechnology applications, this refurbished Nuaire animal transfer station offers reliable containment performance for laboratories and animal research facilities requiring HEPA-filtered airflow environments.
The NU-620-400 is part of Nuaire’s AllerGard animal transfer station platform and was specifically engineered for vivarium workflows involving rodent handling and cage transfer procedures. Unlike traditional biosafety cabinets designed primarily for microbiology or tissue culture applications, the AllerGard platform emphasizes allergen reduction, ergonomic cage-changing workflows, operator comfort, and efficient dual-sided access for laboratory animal handling operations. Nuaire AllerGard systems have been widely used throughout pharmaceutical vivariums, biotechnology animal facilities, academic research institutions, and government animal research laboratories because of their advanced airflow systems, ergonomic operation, and durable containment design.
At American Instrument Exchange, each animal transfer station is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Laboratories and vivarium facilities outfitting containment-focused workflows may also browse additional refurbished biosafety cabinets, laboratory incubators, centrifuges, laboratory refrigerators, and freezers available through American Instrument Exchange.
The Nuaire AllerGard NU-620-400 Animal Transfer Station is a 4-foot containment workstation engineered for laboratory environments requiring contamination-controlled airflow during cage changing and laboratory animal handling procedures. Nuaire developed the AllerGard platform specifically for vivarium workflows where operator protection, environmental protection, and animal protection must be maintained during rodent handling and cage transfer operations.
Unlike conventional biosafety cabinets with enclosed front sash openings, the NU-620-400 uses an ergonomic dual-sided open-access workstation configuration intended to simplify cage changing, bedding transfer, animal handling, and vivarium workflows while maintaining directional HEPA-filtered airflow containment. The dual-sided access design may improve operator efficiency and workflow flexibility during repetitive high-volume cage-changing procedures in space-limited vivarium environments.
The NU-620-400 operates using Nuaire’s “push-pull” airflow system, which uses separate supply and exhaust airflow modules to create a clean work zone while helping contain allergens generated during animal handling procedures. HEPA-filtered supply airflow provides ISO Class 5 cleanliness within the work area, while the exhaust airflow system helps reduce allergen escape into surrounding laboratory environments.
This specific NU-620-400 configuration includes cage-deep wells designed to lower stacked cages and improve technician accessibility during transfer procedures. The station also features an electric hydraulic lift system with approximately 12 inches of work-surface adjustment range, allowing operators to raise or lower the workstation height for improved ergonomics during extended vivarium procedures.
Additional features commonly associated with the NU-620 platform may include stainless steel plenums and work surfaces, hinged polycarbonate viewing windows, LED lighting, airflow monitoring systems, side-mounted push/pull bars, omnidirectional casters, and low-noise blower systems depending on the specific configuration of the unit.
Laboratories and vivarium facilities outfitting complete containment workflows may also be interested in refurbished CO2 incubators, ultra-low freezers, autoclaves, and water baths available through American Instrument Exchange.
The Nuaire AllerGard NU-620-400 Animal Transfer Station is commonly used for vivarium workflows requiring contamination-controlled airflow during laboratory animal handling procedures. Typical applications may include rodent cage changing, animal transfer procedures, bedding changes, pharmaceutical animal research, biotechnology animal studies, allergen-control workflows, and laboratory animal handling applications.
This animal transfer station may also be appropriate for pharmaceutical research facilities, vivariums, biotechnology laboratories, academic animal research programs, government research institutions, and laboratory environments requiring HEPA-filtered airflow during animal transfer operations.
This animal transfer station may be suitable for vivariums, pharmaceutical research facilities, biotechnology laboratories, academic research institutions, cleanroom animal facilities, government laboratories, and containment-focused animal research environments.
Its ergonomic dual-sided access configuration, cage-deep wells, and adjustable-height operation may make it especially appropriate for facilities performing repetitive cage-changing procedures requiring efficient workflow design and allergen reduction.
|
Specification |
Details |
|
Manufacturer |
Nuaire |
|
Model |
AllerGard NU-620-400 |
|
Configuration |
Animal Transfer Station |
|
Nominal Width |
4 ft |
|
Airflow Design |
HEPA-filtered push-pull airflow |
|
Protection Type |
Personnel, animal, and environmental protection |
|
Workstation Design |
Dual-sided open-access workstation |
|
Work Access Opening |
14 in |
|
Height Adjustment |
Electric hydraulic lift system |
|
Work Surface |
Stainless steel |
|
Filtration |
HEPA supply and exhaust filtration |
|
Lighting |
LED lighting |
|
Exterior Dimensions |
Approx. 48” W × 30.6” D × 80.5”–92.5” H |
|
Work Area Dimensions |
Approx. 42.6” W × 28.3” D × 25.5” H |
|
Downflow Velocity |
Approx. 60 FPM |
|
Inflow Velocity |
Approx. 25 FPM |
|
Weight |
Approx. 475 lbs |
|
Electrical Requirements |
115V, 60Hz |
|
Included Accessories |
Stand and new HEPA filters |
|
Warranty |
90-day warranty |
|
Condition |
Refurbished |
Specifications compiled from Nuaire manufacturer literature, distributor technical references, and American Instrument Exchange product information.
American Instrument Exchange has extensive experience refurbishing used biosafety cabinets, animal transfer stations, and laboratory containment equipment for research and pharmaceutical environments.
Each animal transfer station is inspected by our technicians to verify proper blower operation, airflow performance, hydraulic lift operation, lighting operation, cabinet integrity, control functionality, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.
Testing procedures include major functional and airflow verification elements associated with animal transfer station performance to help support operational readiness upon installation at your facility.
Animal transfer stations should be evaluated and certified by qualified field technicians after installation and before laboratory use when required by institutional protocols or vivarium standards.
American Instrument Exchange performs functional testing prior to shipment to support operational readiness upon arrival. Buyers should confirm facility compatibility, airflow requirements, electrical requirements, and certification standards prior to installation.
Certification services are available throughout New England through AIE Laboratory Services, which provides biosafety cabinet certification, preventative maintenance, testing, repair, and field service support for laboratory containment equipment.
Operational requirements may vary depending on vivarium protocols, institutional standards, and laboratory animal handling procedures.
Animal transfer stations are oversized laboratory containment systems that may require special handling during transportation, delivery, and installation. Buyers should confirm facility access dimensions, doorway clearances, elevator compatibility, electrical compatibility, and final equipment placement before shipment.
Depending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.
The ergonomic dual-sided workstation configuration and electric lift system may require additional planning for final positioning within cage-changing rooms or vivarium workflows.
The NU-620-400 is specifically designed for vivarium and cage-changing workflows rather than microbiology or tissue culture procedures. Its dual-sided open-access configuration allows easier cage transfer operations while maintaining HEPA-filtered containment airflow.
Nuaire’s push-pull airflow system uses independent supply and exhaust airflow modules to maintain clean airflow within the work zone while simultaneously helping contain allergens generated during cage-changing procedures.
The deep-well configuration lowers the height of stacked cages, making cages easier for technicians to access during transfer procedures and reducing repetitive reaching or lifting during cage-changing workflows.
Yes. The NU-620-400 includes an electric hydraulic lift system that provides approximately 12 inches of work-surface height adjustment to improve ergonomics for different operators.
Dual-sided transfer stations may improve workflow efficiency in space-limited vivariums because operators can access cages and supplies from multiple sides during animal handling procedures.
Yes. Unless otherwise specified, American Instrument Exchange installs new HEPA filters before shipment. Transfer stations are inspected and tested by our technicians prior to delivery.
American Instrument Exchange technicians inspect airflow systems, blower operation, hydraulic lift functionality, cabinet controls, lighting systems, and overall workstation condition prior to shipment.
Yes. A 90-day warranty from American Instrument Exchange is included.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.