Laboratories with growing cell culture programs often face a common challenge: increasing incubation capacity without sacrificing valuable floor space. The NuAire NU-8700 Dual-Stack CO₂ Incubator addresses this need by combining two fully independent incubation chambers into a single vertical system, effectively doubling culture capacity while maintaining the footprint of a single incubator. Designed for research environments where multiple projects, investigators, or cell lines must be maintained simultaneously, the NU-8700 delivers dependable environmental control, contamination protection, and operational flexibility in one space-saving platform.
Each chamber operates independently, allowing researchers to maintain different temperatures, CO₂ concentrations, or experimental conditions without affecting the other incubator. Continuous closed-loop HEPA filtration, precise temperature regulation, controlled humidity, and a corrosion-resistant stainless steel interior help provide the stable environment required for sensitive mammalian cell culture. For busy biotechnology laboratories, pharmaceutical research facilities, university core laboratories, and hospital research centers, the NU-8700 offers the productivity of two incubators while simplifying laboratory layout and infrastructure. Purchasing a refurbished NuAire NU-8700 from American Instrument Exchange provides laboratories with premium dual-incubator capacity at substantial savings compared with purchasing two new standalone incubators.
Dual independently controlled incubation chambers
Approximately 6.6 cu. ft. total capacity (3.3 cu. ft. per chamber)
Independent temperature and CO₂ control for each chamber
Temperature range from ambient +5°C to 55°C
CO₂ range from 0% to 20%
Closed-loop HEPA air filtration
Stainless steel chamber interiors
Rounded interior corners for simplified cleaning
Adjustable stainless steel shelves
High-humidity water reservoir
Digital microprocessor controls
Audible and visual alarms
Stack configuration minimizes laboratory footprint
90-day warranty from American Instrument Exchange
The defining advantage of the NuAire NU-8700 is not simply its incubation performance—it's its ability to support multiple research programs simultaneously. Rather than placing all cultures into one large chamber, researchers gain two completely independent incubation environments that can operate under different conditions.
One chamber may be dedicated to routine mammalian cell culture while the second supports stem cells, primary cultures, quality control samples, or long-term experiments. Separate chambers also reduce unnecessary door openings, minimizing environmental disturbances for cultures that do not require access throughout the day.
Because each chamber functions independently, laboratories gain additional operational flexibility. One chamber can remain in service while maintenance or cleaning is performed on the other, helping reduce downtime in laboratories where incubators operate continuously.
The stacked design also makes the NU-8700 particularly attractive for facilities where laboratory floor space is limited but incubation demand continues to grow. Rather than purchasing additional floor-standing incubators, researchers can effectively double capacity within the footprint of a single instrument.
The NuAire NU-8700 is commonly used for:
Mammalian cell culture
Stem cell research
Primary cell culture
Cancer biology
Tissue engineering
Regenerative medicine
Hybridoma production
Protein expression
Pharmaceutical research
Biotechnology research
Vaccine development
Clinical laboratory research
Cell banking
Long-term maintenance of valuable cell lines
The dual independent chambers make the incubator particularly valuable for laboratories managing multiple concurrent research projects or requiring physical separation between different culture programs.
The NuAire NU-8700 is well suited for biotechnology companies, pharmaceutical manufacturers, university research laboratories, hospital research facilities, government laboratories, and contract research organizations requiring increased incubation capacity without expanding laboratory space.
Its dual-stack configuration is especially beneficial for shared laboratory environments where multiple investigators require dedicated incubation space. Individual chambers can be assigned by project, department, or researcher while maintaining independent environmental settings and minimizing cross-traffic between experiments.
Each chamber of the NU-8700 is independently controlled using a microprocessor-based environmental management system designed to maintain stable incubation conditions throughout routine laboratory operation. Temperature control from 5°C above ambient to 55°C supports a wide variety of mammalian cell culture applications, while independent CO₂ regulation from 0% to 20% allows each chamber to be optimized for specific experimental requirements.
Because the chambers operate independently, opening one incubator does not disturb the environmental conditions within the second chamber. This isolation improves temperature stability for long-term cultures while reducing recovery time compared with repeatedly accessing a single large incubator throughout the day.
NuAire designed the NU-8700 to simplify contamination prevention through continuous air purification and an interior optimized for routine cleaning. Each chamber utilizes a closed-loop HEPA filtration system that continuously filters recirculated chamber air, helping reduce airborne particulates and maintain a cleaner incubation environment during normal operation.
The polished stainless steel chamber features rounded interior corners that eliminate difficult-to-clean crevices where contaminants can accumulate. Removable shelving and interior components simplify routine maintenance, while the natural humidity reservoir supports healthy cell growth by reducing evaporation of culture media during extended incubation.
By combining continuous HEPA filtration with independently controlled chambers, the NU-8700 helps laboratories reduce contamination risk while providing greater flexibility for managing multiple culture programs simultaneously.
The NuAire NU-8700 dual-stack configuration provides approximately 13.2 cubic feet (374 liters) of total incubation capacity, with each independently controlled chamber offering approximately 6.6 cubic feet (187 liters) of usable space. This generous capacity allows laboratories to significantly increase throughput while maintaining complete separation between research projects, investigators, or cell lines.
Each chamber easily accommodates large quantities of T-flasks, culture dishes, multiwell plates, roller bottles, spinner flasks, cell culture bags, and other vessels commonly used for mammalian cell culture. Adjustable stainless steel shelving allows researchers to customize the chamber layout for different vessel sizes while maximizing available incubation space.
For optimal environmental performance, culture vessels should be evenly distributed throughout each chamber to allow unrestricted airflow and uniform circulation of temperature, humidity, and CO₂. Many laboratories dedicate one chamber to routine production cultures while reserving the second for primary cells, stem cell research, long-term experiments, or sensitive projects requiring minimal disturbance. Because each chamber operates independently, researchers can access one incubator without affecting the environmental stability of cultures housed in the other.
One of the greatest advantages of the NuAire NU-8700 is its ability to provide the capacity of two full-size CO₂ incubators while occupying substantially less laboratory floor space than two separate units. For growing research facilities, this efficient vertical configuration maximizes incubation capacity without requiring additional laboratory renovations or bench space.
Independent environmental controls allow each chamber to operate separately, giving laboratories the flexibility to dedicate chambers to different research groups or experimental protocols. This reduces unnecessary door openings, minimizes environmental fluctuations, and improves overall laboratory workflow.
The continuous closed-loop HEPA filtration system helps maintain cleaner chamber air during routine operation, while the stainless steel interior and removable shelving simplify routine cleaning and maintenance. Together, these features contribute to dependable long-term operation while helping laboratories maximize productivity from a single dual-stack incubator system.
| Specification | Details |
|---|---|
| Manufacturer | NuAire |
| Model | NU-8700 |
| Configuration | Dual-Stack CO₂ Incubator |
| Chamber Capacity | Approximately 6.6 cu. ft. (187 L) per chamber |
| Total Capacity | Approximately 13.2 cu. ft. (374 L) |
| Temperature Range | Ambient +5°C to 55°C |
| CO₂ Range | 0% to 20% |
| CO₂ Sensor | Thermal Conductivity (TC) |
| Air Filtration | Closed-Loop HEPA Filtration |
| Humidity Control | Natural Water Reservoir |
| Chamber Material | Stainless Steel |
| Interior Corners | Rounded for Simplified Cleaning |
| Shelving | Adjustable Stainless Steel Shelves |
| Controller | Independent Digital Microprocessor Controls |
| Alarm System | Audible and Visual |
| Interior Dimensions (Each Chamber) | Approximately 21.5" W × 22.5" D × 24.0" H |
| Exterior Dimensions | Approximately 27.5" W × 34.0" D × 76.0" H |
| Electrical Requirements | 120 V |
| Approximate Weight | Approximately 650 lb |
Specifications are believed to be accurate but may vary depending on factory-installed options. Please verify all specifications prior to purchase.
The NU-8700 combines two full-size 6.6 cubic foot incubators into a single stacked system, providing over 13 cubic feet of total incubation capacity while maintaining the footprint of one piece of equipment. This makes it an excellent solution for laboratories that need additional capacity but have limited floor space.
Yes. Each chamber has its own temperature control, CO₂ regulation, alarms, and environmental management system. Researchers can maintain different incubation conditions or dedicate chambers to separate projects without affecting one another.
A stacked system saves valuable laboratory floor space, simplifies laboratory layout, and centralizes incubation capacity while still providing the operational flexibility of two independent incubators.
Each chamber continuously circulates air through a HEPA filter to remove airborne particulates during normal operation. Cleaner chamber air helps reduce contamination risk and supports healthier long-term cell cultures.
The incubator is ideal for mammalian cell culture, stem cell research, regenerative medicine, cancer biology, vaccine development, pharmaceutical research, biotechnology, protein expression, tissue engineering, and other life science applications requiring large incubation capacity.
Absolutely. The independent chambers allow multiple investigators or research groups to operate simultaneously while maintaining separate environmental conditions and minimizing disruptions caused by routine chamber access.
Each chamber offers approximately 6.6 cubic feet (187 liters) of usable incubation space, for a combined total of approximately 13.2 cubic feet (374 liters), making it an excellent choice for high-throughput cell culture laboratories.
Purchasing a refurbished NuAire NU-8700 from American Instrument Exchange provides laboratories with the productivity of two independently controlled full-size CO₂ incubators in one space-saving system at substantial savings compared with purchasing new equipment. Every incubator is inspected and tested prior to shipment and includes a 90-day warranty, providing confidence that it is ready to support demanding cell culture applications.
Click here to see the Nuaire NU-8700 on the American Instrument Exchange YouTube channel.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.