Thermo Scientific 1510 4' Class II Type B2 Biosafety Cabinet
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Thermo Scientific 1510 is a 4-foot Class II Type B2 biosafety cabinet designed for laboratory applications requiring total exhaust containment. Unlike a conventional Type A2 cabinet that recirculates a portion of HEPA-filtered air within the work chamber, the Thermo 1510 exhausts 100% of cabinet air through a dedicated external exhaust system. This configuration makes the 1510 appropriate for specialized biological workflows that may involve limited quantities of volatile toxic chemicals or radionuclides when permitted by the laboratory's risk assessment and safety protocols.
The Thermo 1510 is part of the 1500 Series B2 platform and combines total-exhaust operation with a 4-foot workspace, 8-inch working sash opening, Type 304 stainless steel interior, SmartFlow airflow compensation, and energy-efficient blower technology. The approximately 48.5-inch-wide work area provides ample room for many biological and pharmaceutical workflows without requiring the footprint of a larger 6-foot B2 cabinet.
Because the 1510 is a Type B2 total-exhaust cabinet, installation requirements are substantially different from those of a typical Type A2 BSC. The cabinet must be connected to a properly designed external exhaust system capable of maintaining the airflow and static pressure required by the cabinet. The Thermo 1510 configuration offered by American Instrument Exchange is specified for approximately 852 CFM exhaust flow at 1.8 inches w.g. static pressure. Facility HVAC capacity, ductwork, exhaust location, room air balance, and certification requirements should therefore be evaluated before purchasing or installing the cabinet.
For laboratories specifically requiring Type B2 containment, a professionally refurbished cabinet can provide significant savings compared with purchasing new equipment. Type B2 cabinets are specialized systems, however, and should be selected based on the actual application and facility infrastructure rather than simply substituted for a Type A2 cabinet.
At American Instrument Exchange, each Thermo Scientific 1510 biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery. Because a Type B2 cabinet requires connection to an external exhaust system to establish its final operating conditions, complete performance verification must ultimately occur after installation and connection to the facility exhaust system. This unit is backed by a 90-day warranty from American Instrument Exchange.
Class II Type B2 biosafety cabinet
100% total-exhaust design
Requires hard connection to an external exhaust system
4-foot nominal cabinet width
8-inch working sash opening
Type 304 stainless steel interior
Approximately 48.5-inch-wide work area
SmartFlow airflow compensation
HEPA-filtered downflow and exhaust
Designed for specialized biological and chemical-containing workflows
Suitable for appropriate work involving limited quantities of volatile toxic chemicals or radionuclides
Energy-efficient motor technology
Counterbalanced sash
LCD information display
Seated-access touchpad controls
Stainless steel work surface
Exhaust requirement approximately 852 CFM at 1.8" w.g.
New HEPA filters included unless otherwise specified
90-day warranty from American Instrument Exchange
The Thermo Scientific 1510 is fundamentally different from the Type A2 biosafety cabinets commonly used for routine cell culture and microbiology. As a Class II Type B2 BSC, the 1510 operates as a total-exhaust cabinet: air entering and moving through the work area is ultimately exhausted from the building rather than partially recirculated within the cabinet.
This airflow configuration allows a properly installed Type B2 cabinet to support specialized applications where biological containment must be combined with work involving limited quantities of volatile toxic chemicals or radionuclides. The cabinet is therefore particularly relevant to pharmaceutical research, toxicology, hazardous-drug research, and other workflows where a standard recirculating Type A2 cabinet may not be appropriate.
HEPA-filtered vertical downflow helps protect materials within the work area from contamination, while inward airflow at the front opening helps protect the operator. Air leaving the cabinet passes through HEPA filtration and is then discharged through the facility's dedicated external exhaust system.
The total-exhaust design is also why installation planning is so important. A Thermo 1510 cannot simply be placed in a laboratory, plugged in, and operated as a conventional recirculating BSC. The building exhaust system must be capable of supporting the cabinet's required airflow and static pressure, and sufficient replacement air must be available to maintain proper room balance.
Once properly installed and certified, however, the Thermo 1510 provides a specialized containment platform for laboratories whose research requires the capabilities of a true Class II Type B2 cabinet.
The primary reason to choose the Thermo Scientific 1510 is application compatibility.
For routine cell culture and microbiology where volatile toxic chemicals are not used, a Class II Type A2 cabinet is often the more practical and energy-efficient solution. A Type B2 cabinet becomes important when the laboratory's procedures require total exhaust because of the materials being handled.
The Thermo 1510 exhausts all cabinet air outside the building through a dedicated duct system. This eliminates the recirculation of cabinet air back through the work area and provides a configuration designed for applications requiring greater dilution and removal of volatile chemical contaminants.
The 4-foot format is also useful for laboratories that need B2 containment without the additional airflow demand and physical footprint associated with a 6-foot total-exhaust cabinet. The approximately 48.5-inch-wide work area provides sufficient room for many procedures while keeping the cabinet itself to approximately 54 inches wide.
For laboratories specifically seeking a used or refurbished Class II Type B2 biosafety cabinet, the Thermo 1510 can therefore provide a cost-effective alternative to purchasing a new total-exhaust system—provided that the laboratory's HVAC infrastructure is compatible with the cabinet.
Understanding the difference between Type B2 and Type A2 is essential before selecting the Thermo Scientific 1510.
A Class II Type A2 biosafety cabinet recirculates a substantial portion of HEPA-filtered air within the cabinet and exhausts the remainder through HEPA filtration. For many cell culture, microbiology, biotechnology, and biological research applications, this configuration provides an efficient and practical containment solution.
The Thermo 1510 Type B2, by comparison, is a total-exhaust cabinet. Air entering the cabinet is not recirculated back into the work area. Instead, the entire exhaust volume is removed through a dedicated building exhaust system.
This makes the B2 configuration appropriate for certain specialized procedures involving biological materials together with limited quantities of volatile toxic chemicals or radionuclides when permitted by the laboratory's safety assessment.
The tradeoff is infrastructure. A Type B2 cabinet requires substantially more exhaust capacity, dedicated ductwork, appropriate replacement air, and careful coordination with the building HVAC system.
For that reason, laboratories should not choose a Type B2 simply because it appears to offer “more containment.” Cabinet type should be selected according to the hazards involved, applicable safety requirements, and the facility's ability to support the required exhaust system.
HVAC compatibility is one of the most important considerations when purchasing a Thermo Scientific 1510.
The 1510 is designed to operate while directly connected to an external exhaust system. American Instrument Exchange's specifications for this configuration identify an exhaust airflow requirement of approximately 852 CFM at 1.8 inches water gauge static pressure.
That represents a substantial continuous air demand for a single 4-foot laboratory cabinet. The building must therefore be capable not only of exhausting this volume but also of providing sufficient replacement air without adversely affecting laboratory pressure relationships or surrounding equipment.
Before purchasing a refurbished Thermo 1510, laboratories should have the proposed installation evaluated by qualified facility, HVAC, biosafety, and certification personnel. Important considerations include available exhaust capacity, duct dimensions, static pressure, room air balance, makeup air, exhaust discharge location, and applicable building and laboratory safety requirements.
This planning is especially important when replacing a Type A2 cabinet with a Type B2. Even if the cabinets occupy similar floor space, their mechanical requirements are fundamentally different.
American Instrument Exchange strongly recommends confirming compatibility with the facility and the professional responsible for installation and certification before purchasing a Type B2 cabinet.
Testing a refurbished Type B2 biosafety cabinet differs from testing a recirculating Type A2 cabinet because the B2's final airflow performance depends on the external exhaust system to which it is connected.
American Instrument Exchange technicians can inspect and test the Thermo 1510's controls, blower components, electrical systems, alarms, lighting, sash operation, HEPA filters, and other cabinet functions at our facility. Unless otherwise specified, new HEPA filters are installed before shipment.
However, our warehouse cannot reproduce every customer's dedicated building exhaust system. Final airflow performance therefore cannot be established solely through warehouse testing.
After installation, the cabinet must be connected to the facility exhaust system, balanced under actual operating conditions, and field certified before being placed into service.
This distinction is important when purchasing any used or refurbished Type B2 cabinet. Successful installation depends not only on the condition of the BSC itself but also on proper integration with the laboratory's mechanical systems.
The Thermo Scientific 1510 may be appropriate for specialized laboratory procedures involving biological containment combined with limited quantities of volatile toxic chemicals or radionuclides when permitted by the laboratory's risk assessment and applicable safety requirements.
Potential environments include pharmaceutical research and development, hazardous-drug research, toxicology laboratories, biotechnology research, specialized microbiology applications, radiological research involving appropriate quantities of radionuclides, and other workflows specifically requiring Class II Type B2 total-exhaust containment.
The suitability of a Type B2 cabinet should always be determined based on the actual materials and procedures involved rather than cabinet type alone.
The Thermo Scientific 1510 is best suited for laboratories that specifically require Class II Type B2 containment and already have—or can install—the necessary external exhaust infrastructure.
This may include pharmaceutical companies, biotechnology facilities, hospital and clinical research laboratories, universities, government research facilities, toxicology laboratories, and other organizations conducting specialized biological procedures involving chemical or radiological hazards compatible with Type B2 operation.
For laboratories performing routine cell culture or microbiology without volatile toxic chemicals or radionuclides, a Type A2 cabinet may provide a simpler and substantially less demanding installation. American Instrument Exchange can help customers compare available Type A2 and Type B2 cabinets when the appropriate configuration has not yet been determined.
| Specification | Details |
|---|---|
| Manufacturer | Thermo Scientific |
| Model | 1510 |
| Series | 1500 Series B2 |
| Cabinet Type | Class II Type B2 Biosafety Cabinet |
| Exhaust Configuration | 100% Total Exhaust |
| External Exhaust | Required |
| Nominal Cabinet Width | 4 ft |
| Exterior Dimensions | 54.3" W × 31.6" D × 71.5" H |
| Work Area Dimensions | 48.5" W × 25.5" D × 25.7–29.2" H |
| Working Sash Opening | 8" |
| Interior Material | Type 304 Stainless Steel |
| Work Surface | Stainless Steel |
| Airflow Management | SmartFlow |
| Exhaust Flow | Approximately 852 CFM |
| Exhaust Static Pressure | Approximately 1.8" w.g. |
| Inflow Air Volume | Approximately 283 CFM |
| Filtration | HEPA |
| Controls | LCD Display / Touchpad Controls |
| Sash | Counterbalanced |
| Shipping Weight | Approximately 545 lb |
| HEPA Filters | New Filters Included Unless Otherwise Specified |
| Warranty | 90 Days from American Instrument Exchange |
Specifications compiled from Thermo Scientific manufacturer literature and American Instrument Exchange product information.
The Thermo Scientific 1510 provides laboratories with a specialized Class II Type B2 total-exhaust containment platform without requiring the acquisition cost associated with purchasing a new B2 biosafety cabinet. For pharmaceutical, biotechnology, toxicology, and other research facilities that specifically require Type B2 operation, a professionally refurbished 1510 can be an excellent way to extend an existing B2 installation or replace an older cabinet while continuing to use established facility exhaust infrastructure.
Unlike a conventional Type A2 biosafety cabinet, the Thermo 1510 is designed around 100% exhaust operation. This makes it appropriate for specialized biological procedures where the laboratory's risk assessment requires the greater dilution and removal of volatile toxic chemicals associated with a Type B2 configuration.
The 4-foot configuration is also advantageous for laboratories that require B2 containment but do not need the workspace or substantially greater exhaust demand of a 6-foot cabinet. Its approximately 48.5-inch-wide work area provides useful space for many research procedures while retaining a manageable laboratory footprint.
Because Type B2 performance depends heavily on the facility exhaust system, purchasing the cabinet itself is only one part of a successful installation. American Instrument Exchange strongly recommends confirming HVAC capacity, ductwork requirements, room balance, and certification requirements before purchasing any Type B2 cabinet.
Every Thermo Scientific 1510 offered by American Instrument Exchange undergoes a detailed inspection, cleaning, refurbishment, and functional testing process prior to shipment. Our technicians evaluate the cabinet's mechanical, electrical, control, blower, alarm, sash, and filtration systems and identify components requiring repair or replacement.
Unless otherwise specified, new HEPA filters are installed at our facility before shipment. Interior surfaces and the stainless steel work area are professionally cleaned and inspected, and cabinet controls, lighting, electrical systems, alarms, and other accessible functions are tested.
There is an important distinction, however, between testing a refurbished Type B2 cabinet at our facility and certifying that cabinet after installation.
The Thermo 1510 depends on a properly designed external exhaust system to establish its final airflow conditions. American Instrument Exchange cannot reproduce every customer's building exhaust system at our warehouse. As a result, final Type B2 performance must be verified after the cabinet has been installed, hard-connected to the facility exhaust system, properly balanced, and field certified.
This is an important part of purchasing any refurbished Type B2 biosafety cabinet and should be considered during project planning.
The Thermo Scientific 1510 is a Class II Type B2 biosafety cabinet designed for specialized total-exhaust containment applications.
Proper field certification is essential after installation because the cabinet's performance depends on both the BSC itself and the facility exhaust system to which it is connected.
Certification may include inflow and downflow velocity measurements, HEPA filter integrity testing, airflow visualization, alarm verification, sash operation, exhaust performance, and other applicable certification procedures.
Biosafety cabinets should also be recertified at appropriate intervals and following changes that may affect containment performance, including relocation, HEPA filter replacement, modifications to the exhaust system, or significant internal service.
For laboratories throughout Greater Boston and New England, AIE Laboratory Services provides biosafety cabinet certification, preventative maintenance, troubleshooting, repairs, HEPA filter replacement, decontamination, and related field services.
Customers planning a B2 installation should coordinate facility exhaust work and final cabinet certification so that the complete system can be evaluated under its actual operating conditions.
The Thermo Scientific 1510 is professionally prepared and packaged for commercial freight shipment from American Instrument Exchange. Customers should verify doorway dimensions, hallways, elevators, loading areas, electrical requirements, and the final cabinet location before delivery.
For the 1510, however, exhaust infrastructure is equally important as physical fit.
A Type B2 cabinet requires connection to a dedicated external exhaust system capable of providing the airflow and static pressure required by the cabinet. The laboratory must also provide adequate replacement air so that operation of the BSC does not create unacceptable room pressure conditions or interfere with other laboratory ventilation equipment.
Facility engineers or qualified HVAC professionals should evaluate the proposed installation before the cabinet arrives. Exhaust capacity, duct routing, static pressure, makeup air, room balance, exhaust discharge, electrical service, and applicable codes should all be considered.
Once installed and connected to the building exhaust system, the Thermo 1510 should be balanced and field certified before being placed into service.
The Thermo Scientific 1510 may be incorporated into pharmaceutical, biotechnology, toxicology, microbiology, hazardous-drug research, and other specialized laboratory workflows requiring Type B2 containment.
Depending on the application, the cabinet may be paired with laboratory refrigerators and freezers for reagent or sample storage, refrigerated centrifuges for sample processing, CO₂ incubators for cell culture workflows, and ultra-low temperature freezers for long-term biological sample preservation.
American Instrument Exchange maintains a broad inventory of professionally refurbished laboratory equipment, allowing laboratories to source multiple pieces of equipment through a single supplier while simplifying procurement and reducing equipment lead times.
Yes. The Thermo Scientific 1510 is a 4-foot Class II Type B2 biosafety cabinet from Thermo's 1500 Series B2 platform. It is designed as a total-exhaust cabinet for specialized applications requiring Type B2 containment.
Yes. External exhaust is fundamental to Type B2 operation. The Thermo 1510 cannot be installed and operated like a conventional recirculating Type A2 cabinet.
The cabinet must be hard-connected to an appropriate facility exhaust system and properly balanced and certified after installation.
The configuration listed by American Instrument Exchange specifies approximately 852 CFM at 1.8 inches w.g. static pressure.
Because building conditions and installations vary, these specifications should be reviewed with the facility engineer, HVAC contractor, biosafety professional, and certification company responsible for the project before purchasing the cabinet.
Potentially, but it is not a direct installation substitute.
A Type A2 cabinet can often operate without being hard-connected to building exhaust. The Thermo 1510 Type B2 requires a dedicated external exhaust system, substantial exhaust capacity, appropriate replacement air, and proper balancing.
Therefore, having enough physical room for the 1510 does not necessarily mean the laboratory can support it. Facility exhaust requirements should be evaluated before changing from an A2 to a B2 cabinet.
Type B2 cabinets are designed for applications requiring greater dilution and removal of volatile toxic chemicals than recirculating BSC configurations can provide.
However, HEPA filters capture particulates; they do not remove chemical vapors or gases. The total-exhaust configuration is what allows appropriate chemical vapors to be removed from the cabinet and discharged through the facility exhaust system.
Whether a particular chemical, concentration, quantity, or procedure is appropriate should be determined through the laboratory's formal risk assessment and applicable safety requirements.
No. A Type B2 cabinet is different, not universally better.
For many routine cell culture, microbiology, and biotechnology procedures, a Class II Type A2 cabinet is the more practical choice. Type B2 cabinets are intended for applications requiring their total-exhaust characteristics and impose substantially greater HVAC and installation requirements.
The correct cabinet type should be selected according to the materials and procedures involved.
A 4-foot cabinet such as the Thermo 1510 provides enough workspace for many laboratory procedures while requiring less floor space and generally imposing a lower total exhaust demand than a comparable 6-foot Type B2 cabinet.
This can be particularly valuable when the laboratory needs true Type B2 containment but has limited HVAC capacity or does not need the additional working width of a 6-foot cabinet.
American Instrument Exchange can inspect and test the cabinet's electrical, mechanical, control, filtration, alarm, and other functional systems and, unless otherwise specified, installs new HEPA filters before shipment.
However, final Type B2 performance cannot be established independently of the customer's external exhaust system. The cabinet must therefore be installed, connected to the building exhaust, balanced, and field certified at its final location.
This distinction is important when purchasing any used or refurbished Type B2 biosafety cabinet.
Loss of external exhaust can compromise the operating conditions required for a Type B2 biosafety cabinet. An exhaust or airflow failure should therefore be treated as a condition requiring immediate evaluation rather than simply silencing or ignoring the alarm.
The cabinet should not be assumed to provide proper containment when the required external exhaust conditions are not being maintained.
Before purchasing a Type B2 cabinet, laboratories should confirm that the proposed location can support the cabinet's physical, electrical, and mechanical requirements.
Of particular importance are the available exhaust airflow and static pressure, ductwork configuration, makeup-air capacity, room pressure requirements, electrical service, delivery route, and certification plan.
If the 1510 is replacing an existing B2 cabinet, providing American Instrument Exchange with information about the existing model and exhaust connection can also help determine whether the replacement is likely to fit the current installation.
Yes. Field certification is particularly important for a Type B2 cabinet because final containment performance depends on the relationship between the BSC and the building exhaust system.
The cabinet should be installed, connected to the facility exhaust system, balanced, and certified before being placed into biological service. Recertification should also be performed after changes to the installation or service that could affect containment performance.
Yes. For laboratories throughout Greater Boston and New England, AIE Laboratory Services provides biosafety cabinet testing, certification, troubleshooting, preventative maintenance, HEPA filter replacement, repairs, decontamination, and related field services.
Type B2 projects should be coordinated with the facility's HVAC personnel because certification depends on the cabinet being properly connected and balanced with the external exhaust system.
Yes. A biosafety cabinet does not need to have been purchased from American Instrument Exchange for AIE Laboratory Services to service or certify it.
This can be particularly valuable for laboratories with existing Type B2 cabinets that are experiencing airflow alarms, certification failures, blower problems, filter-loading issues, or other performance concerns.
American Instrument Exchange generally retains available used components to support the refurbishment and repair of additional biosafety cabinets rather than routinely selling used parts individually. Depending on the component and current availability, however, we may be able to assist in identifying or sourcing a replacement.
Replacement HEPA filters can be obtained through manufacturers and qualified filter suppliers. HEPA replacement on a previously used B2 cabinet should be performed using appropriate biosafety and decontamination procedures.
For customers in New England, AIE Laboratory Services can assist with decontamination, HEPA filter replacement, troubleshooting, and subsequent certification.
Depending on current inventory, yes. American Instrument Exchange can work with laboratories requiring multiple B2 cabinets or a combination of Type A2 and Type B2 cabinets for different research areas.
For larger projects, it is particularly important to involve facility engineering early because multiple Type B2 cabinets can represent a significant cumulative exhaust and makeup-air requirement.
American Instrument Exchange can also supply complementary laboratory equipment, including CO₂ incubators, centrifuges, refrigerators, freezers, ultra-low temperature freezers, and other equipment needed for a laboratory expansion or build-out.
American Instrument Exchange specializes in professionally refurbished laboratory equipment rather than simply reselling used instruments. Each Thermo Scientific 1510 is inspected, cleaned, tested, and prepared for continued laboratory service by experienced technicians.
Unless otherwise specified, new HEPA filters are installed prior to shipment, and the unit is backed by a 90-day warranty from American Instrument Exchange.
More importantly for a specialized cabinet such as the 1510, American Instrument Exchange understands that purchasing a Type B2 BSC involves more than choosing a cabinet of the correct width. Exhaust requirements, installation conditions, certification, and long-term service all matter.
For laboratories with the appropriate external exhaust infrastructure and a genuine requirement for Class II Type B2 total-exhaust containment, a refurbished Thermo Scientific 1510 can provide a cost-effective alternative to purchasing new while retaining the specialized capabilities required by the laboratory's workflow.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.