As a crucial piece of laboratory equipment, PHCBI Cell-IQ Series High Heat Sterilization CO2 incubators are designed to ensure highly accurate, reproducible chamber conditions. Our cell culture incubators provide a contamination-free environment while allowing precise CO2 or CO2/O2 control - essential for in vivo environment replication.
Uniform Consistent Environment: InCu-saFe and SafeCell UV function together to create contamination control against external microbes. A unique heating system and the dual filter infrared sensor precisely control temperature and CO2 levels, respectively.
Rapid CO2 Recovery with Dual-Wave Infrared (IR) Sensor: A dual filter infrared sensor signals the microprocessor controller to inject CO2 to maintain desired setpoint conditions. Sensor response accelerates CO2 recovery to setpoint without overshoot following frequent door openings.
Dual Heat Sterilization: An integrated auxiliary sterilization system is utilized together with the CO2 incubator cultivation heaters to provide an effective, energy efficient sterilization process. The primary heater maintains precise temperature control over a setpoint range from 5°C above ambient to 50°C. The secondary heater is activated when the high heat sterilization cycle is initiated as both heaters combine to reach 180°C. Specialized melamine foam insulation minimizes heat leakage to adjacent incubators and dramatically reduces elevated external surface temperatures.
Incubator Decontamination with InCu-saFe and SafeCell UV: The PHCbi inCu-saFe copper enriched, stainless steel interior surfaces create a germicidal barrier to airborne contaminants that enter the dry heat incubator during door openings. The PHCbi inCu-saFe combines the germicidal properties of elemental copper with the corrosion and discoloration resistance of stainless steel. SafeCell UV lamp decontaminates circulated air and the humidity reservoir.
Triple Protection Incubator Decontamination: The MCO-170AICUVDL-PA automatic high heat sterilization CO2 incubator is designed for use in medical and government research, pharmaceutical and biotech applications. This dry heat incubator includes three methods of protection against cell culture contamination. In addition to inCu-saFe and SafeCell UV contamination control, an optional, manually initiated high heat sterilization cycle provides a 180°C (355°F) decontamination process without the need to remove CO2 incubator chamber components.
| EXTERIOR DIMENSIONS | 24.4" W x 29.7" D x 35.6" H (620 x 755 x 905 mm) - Excludes handle and other external projections |
|---|---|
| INTERIOR DIMENSIONS | 19.3" W x 20.6" D x 26.2" H (490 x 523 x 665 mm) |
| INTERIOR VOLUME | 5.8 cu.ft. (165 L) |
| DATA ACQUISITION | USA data download |
| INNER DOOR | One - tempered glass - field reversible |
| SHELVES | 4 copper enriched, stainless steel alloy (inCu-saFe) |
| ACCESS PORT | 1: Rear upper left (1.2" (30 mm) diameter) |
| INSULATION | Melamine resin foam |
| AIR FILTER | 0.3 um, Efficiency: 99.97 % or higher |
| UV LAMP | 4W x 1 (ozone-free emission) |
| NET WEIGHT | 176 lbs (80 kg) |
| TEMPERATURE CONTROL RANGE | + 5°C Above ambient to +50°C (ambient temperature: 5°C to 35°C) |
| TEMPERATURE UNIFORMITY | ±0.25ºC (ambient temperature: 23ºC, setting: 37ºC, CO2: 5 %, no load) |
| MAXIMUM POWER CONSUMPTION | Max. 376 W |
| CO2 CONTROL RANGE | 0% - 2 ±0.15% |
| CO2 CONTROLLER | Proportional |
| CO2 GAS CONNECTION | 0.157 inch to 0.36 inch (4 mm to 6 mm) diameter tube can be connected |
| CO2 GAS PRESSURE | 0.03 MPa(G) (0.3kgf/cm2(G),4.3 psi(G)) |
| CO2 VARIATION | ±0.15% (ambient temperature: 23ºC, setting: 37ºC, CO2: 5%, no load) |
| CO2 SENSOR TYPE | Dual-wave infrared (IR) |
| DATA OUTPUT | USB |
| DECONTAMINATION METHODS | High Heat Sterilization |
| CONTAMINATION CONTROLS | InCu-SaFe copper enriched stainless steel interior and shelves, standard SafeCell UV light |
| DECONTAMINATION CYCLE TIME | ~ 11.0 Hours |
| DISPLAY | LCD color touchscreen - readable in 0.1° increments |
| HEATING SYSTEM | Direct Heat and Air Jacket System |
| HUMIDIFYING SYSTEM | Natural evaporation with humidifying pan, 95 %R.H.±5 %R.H. |
This PHCbi Incubator is used and reconditioned. Our technicians test CO2 incubators using a digital data logger to verify the accuracy of temperature controls and readouts, as well as using a Fyrite indicator to measure CO2 levels in the chamber. Additionally, if you have specific testing requirements or requests, please inform us. We will gladly work with you to ensure these requirements are addressed during testing.
We replace any hardware or parts as is necessary and clean all incubators thoroughly prior to shipment.
The photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.
For inquiries about the PHCbi Cell-IQ Series CO2 Cell Culture Incubator, call us at 978-521-2221 or fill out the form on this page.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer’s specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly. While we may not be able to test for specific analytical applications we do our best to simulate the conditions under which the equipment will be used in your lab. If you have particular testing requirements please let us know and we’ll work with you to make sure these are addressed during testing.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements. In many cases we can offer inside delivery. Customers are also welcome to make pick-up arrangements using their own preferred carrier.
All shipments are FOB Haverhill, MA. American Instrument Exchange will take reasonable steps to protect the equipment during shipment and the equipment will be fully insured. The customer will be charged for all shipping and handling charges, and fees incurred in the process of delivering the order.
For local customers in and around New England we can offer shipping and delivery using a local moving company trained by our staff to handle and deliver lab equipment. Our local movers can provide either standard dock-to-dock delivery or bring the equipment into your lab and set it in place.
Prior to signing the POD (Proof of Delivery), you are responsible for inspecting the goods for any damage. You MUST note any damage on the POD prior to letting the driver leave. This is to protect you, the receiver of the goods in the unlikely event of any damage. Once you sign the POD free and clear from damage, the goods are then deemed delivered in good order and no further claims would be applicable. This is the standard for all transportation so we want to protect you, our valued client.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by American Instrument or a technician hired by/vetted by American Instrument Exchange’s during the warranty period. The customer will be responsible for proper packaging of the equipment and all included accessories.
Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues will be subject to a cancellation and restocking fee of between 20% and 40% and responsible for the full total of the shipping & handling costs for both the delivery and the return of the equipment.
Yes – call or email us today with a list of equipment you’re looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we’ll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.