Thermo Forma 3950 reach-in incubator
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
As cell culture operations grow, standard benchtop CO₂ incubators often become limiting. Large tissue culture programs, production laboratories, and core research facilities require substantially greater incubation capacity while maintaining the precise environmental conditions necessary for healthy cell growth. The Thermo Forma 3950 Large Capacity Reach-In CO₂ Incubator was engineered specifically for these high-throughput applications, combining a spacious 29 cubic foot (821-liter) chamber with accurate CO₂ regulation, excellent temperature uniformity, and a robust reach-in design that accommodates large culture systems and laboratory equipment.
Designed for laboratories processing hundreds of culture vessels simultaneously, the Forma 3950 provides stable temperature control, programmable humidity management, and Thermo's Directed Airflow system to create uniform incubation conditions throughout the chamber. The incubator easily accommodates roller bottle apparatus, large shaker platforms, bioreactors, stacked culture vessels, and high-density shelving configurations that exceed the capacity of conventional floor-standing CO₂ incubators. Purchasing a refurbished Thermo Forma 3950 from American Instrument Exchange provides laboratories with production-scale incubation capability while significantly reducing capital equipment costs.
Approximately 29 cu. ft. (821 L) chamber capacity
CO₂ concentration range from 0% to 20%
Thermal conductivity (TC) CO₂ sensor
Directed Airflow system
Heated solid outer door
Heavy-duty stainless steel chamber
Triple-pane heated inner glass door
Three humidity operating modes
Automatic, semi-automatic, or manual water fill options
Up to 27 adjustable shelf positions
Interior and exterior accessory outlets
Dual side access ports
Audible and visual alarm system
Remote alarm contacts
Locking swivel casters
90-day warranty from American Instrument Exchange
The Thermo Forma 3950 was developed for laboratories where incubation capacity directly affects productivity. Rather than operating multiple smaller incubators across several rooms, researchers can consolidate large culture volumes into a single controlled environment while maintaining excellent temperature and CO₂ uniformity.
Its expansive interior supports everything from traditional tissue culture flasks and multiwell plates to roller bottle systems, orbital shakers, bioreactors, and custom research equipment. With up to 27 adjustable shelf positions and more than 145 square feet of potential shelf area, laboratories can configure the chamber to maximize usable incubation space for virtually any workflow.
The Forma 3950 is commonly found in biotechnology companies, pharmaceutical manufacturing facilities, vaccine development laboratories, university core facilities, contract research organizations (CROs), and cell therapy research centers where reliable, large-capacity incubation is essential to daily operations.
Many laboratories pair the Forma 3950 with biosafety cabinets, refrigerated centrifuges, laboratory refrigerators, ultra-low temperature freezers, and automated cell processing equipment to create integrated production workflows capable of supporting high sample throughput.
The Thermo Forma 3950 is commonly used for:
Mammalian cell culture
Large-scale tissue culture
Cell therapy research
Vaccine development
Monoclonal antibody production
Stem cell expansion
Hybridoma culture
Biopharmaceutical manufacturing
Clinical research
Large-volume microbiology
Contract research
University core laboratories
Biotechnology production
Process development
Its combination of large chamber capacity and precise environmental control makes it particularly valuable for laboratories scaling from research into pilot production or routine manufacturing support.
The Thermo Forma 3950 is well suited for pharmaceutical manufacturers, biotechnology companies, academic research institutions, contract development and manufacturing organizations (CDMOs), government laboratories, and industrial research facilities.
Because the chamber accommodates large equipment such as shaker platforms and bioreactors while maintaining excellent environmental uniformity, it is especially valuable in laboratories where multiple investigators share incubation space or where production-scale cell culture requires centralized environmental control.
Large-capacity incubators must maintain stable conditions across a significantly larger workspace than conventional laboratory incubators. The Thermo Forma 3950 addresses this challenge through its Directed Airflow system, which distributes conditioned air uniformly throughout the chamber to improve temperature consistency and accelerate recovery after door openings. Unlike conventional airflow systems, this design minimizes localized temperature variation while reducing product desiccation during extended incubation periods.
The incubator maintains temperatures suitable for routine mammalian cell culture while accurately regulating CO₂ concentrations from 0% to 20% using a reliable thermal conductivity (TC) sensor. Three selectable humidity operating modes and multiple water-fill options allow laboratories to balance humidity performance with operational convenience based on their individual workflow requirements.
The Forma 3950 incorporates several features that support consistent environmental conditions during continuous operation. A heated door assembly helps minimize condensation, while the insulated cabinet reduces heat transfer from the surrounding laboratory environment. Two through-wall access ports allow researchers to introduce probes, sensors, or power cables without leaving the door open, helping preserve stable incubation conditions throughout long-term experiments. Standard remote alarm contacts and optional data outputs also simplify integration with laboratory monitoring systems, making the incubator well suited for regulated research and production environments.
With approximately 29 cubic feet (821 liters) of usable chamber space, the Thermo Forma 3950 is designed to support laboratories that routinely incubate large numbers of cell culture vessels and production-scale biological samples. The spacious interior accommodates T-flasks, roller bottles, multiwell plates, spinner flasks, cell factories, culture bags, bioreactor accessories, and compatible shaker platforms, allowing researchers to configure the chamber for a wide variety of cell culture workflows.
The incubator offers up to 27 adjustable shelf positions, making it easy to customize the chamber for different vessel heights and production requirements. Maintaining adequate spacing between shelves and avoiding obstruction of the directed airflow system helps promote uniform temperature and CO₂ distribution throughout the cabinet, particularly when operating with large sample loads.
For multi-user laboratories or production environments, organizing cultures by project, production batch, or investigator can simplify sample retrieval while minimizing unnecessary door openings. Reducing the frequency and duration of door openings helps maintain environmental stability and supports more consistent incubation conditions during long-term cell culture experiments.
The Thermo Forma 3950 was engineered for continuous operation in research and production laboratories where large incubators often remain in service around the clock. Its insulated cabinet construction, efficient heating system, and Directed Airflow technology work together to maintain stable environmental conditions while minimizing unnecessary energy consumption.
The heated door assembly reduces condensation without requiring excessive heating, while multiple humidity operating modes allow laboratories to select the level of humidity management appropriate for their application. Depending on workflow requirements, users can choose automatic, semi-automatic, or manual water-fill operation, helping balance convenience with water usage and routine maintenance.
Because the Forma 3950 can replace several smaller CO₂ incubators, many laboratories also benefit from simplified maintenance schedules, fewer calibration procedures, and more centralized environmental monitoring. Consolidating incubation capacity into a single large chamber can improve operational efficiency while reducing overall equipment footprint.
| Specification | Details |
|---|---|
| Manufacturer | Thermo Forma |
| Model | 3950 |
| Incubator Type | Large Capacity Reach-In CO₂ Incubator |
| Chamber Capacity | Approximately 821 L (29 cu. ft.) |
| Chamber Material | Stainless Steel |
| CO₂ Range | 0% to 20% |
| CO₂ Sensor | Thermal Conductivity (TC) |
| Heating System | Electric Heating |
| Airflow System | Directed Airflow |
| Humidity Control | Three Selectable Operating Modes |
| Water Fill | Automatic, Semi-Automatic, or Manual |
| Door Configuration | Heated Solid Outer Door with Heated Triple-Pane Inner Glass Door |
| Shelf Positions | Up to 27 |
| Access Ports | Dual Side Access Ports |
| Interior Power Outlets | Yes |
| Exterior Accessory Outlet | Yes |
| Alarm System | Audible, Visual, and Remote Alarm Contacts |
| Mobility | Locking Swivel Casters |
| Interior Dimensions | Approximately 38" W × 28" D × 54" H |
| Exterior Dimensions | Approximately 48" W × 36" D × 78" H |
| Electrical Requirements | 230 V |
| Approximate Weight | Approximately 700 lb |
Specifications are believed to be accurate but may vary depending on factory-installed options. Please verify all specifications prior to purchase.
The Forma 3950 is a large-capacity reach-in incubator designed for high-throughput laboratories. Its 821-liter chamber accommodates substantially more cultures than conventional floor-standing CO₂ incubators and is capable of supporting large research or production workflows.
Yes. The spacious chamber is designed to support large laboratory accessories including compatible shaker platforms, roller bottle systems, cell factories, and other equipment that may not fit inside standard CO₂ incubators. This flexibility makes the incubator well suited for pilot-scale research and process development.
Thermal conductivity sensors provide dependable CO₂ measurement for routine cell culture applications and are well suited for incubators that operate continuously under stable environmental conditions. Many laboratories choose TC sensors because of their reliability, straightforward operation, and lower long-term maintenance requirements.
The Forma 3950 allows laboratories to select different humidity operating modes depending on the application's evaporation control requirements and operational preferences. Multiple water-fill options provide flexibility for laboratories with varying workflow demands and maintenance schedules.
The heated inner glass door helps minimize condensation while allowing researchers to view cultures without exposing the entire chamber to ambient laboratory conditions. This design improves environmental stability by reducing unnecessary heat and CO₂ loss during routine sample inspection.
Yes. The incubator was developed specifically for laboratories requiring large incubation capacity for applications such as vaccine development, monoclonal antibody production, stem cell expansion, biopharmaceutical process development, and other high-volume cell culture workflows.
Yes. The incubator includes remote alarm contacts and accessory connections that allow integration with facility monitoring systems and external instrumentation, making it suitable for regulated laboratory environments where continuous equipment monitoring is important.
Purchasing a refurbished Thermo Forma 3950 from American Instrument Exchange provides laboratories with production-scale CO₂ incubation capacity at substantial savings compared with buying new equipment. Every incubator is inspected and tested prior to shipment and includes a 90-day warranty, providing confidence that it is ready to support demanding laboratory research and manufacturing applications.
CLICK HERE to see the Thermo Forma 3950 reach-in CO2 incubator on our YouTube channel
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.