The Mettler Toledo XPE2002S Precision Balance is a high-performance laboratory balance designed for accurate, efficient weighing of samples up to 2.1 kg. With 10 mg (0.01 g) readability, fast stabilization, automatic internal adjustment, and Mettler Toledo's advanced weighing technology, the XPE2002S is well suited for pharmaceutical research, formulation, quality control, sample preparation, chemical laboratories, and other applications requiring dependable precision weighing.

Available used and refurbished from American Instrument Exchange, the Mettler Toledo XPE2002S provides laboratories with professional-grade precision weighing performance at a significantly lower acquisition cost than purchasing comparable new equipment. Each balance is inspected, cleaned, calibrated, and tested for weighing accuracy and repeatability before shipment and includes a 90-day warranty from American Instrument Exchange.

Key Features

  • 2.1 kg maximum weighing capacity

  • 10 mg / 0.01 g readability

  • Typical repeatability of 4 mg

  • Typical USP minimum weight of approximately 8.2 g

  • proFACT automatic internal adjustment

  • SmartPan weighing pan helps reduce the effects of air movement

  • StatusLight provides an immediate visual indication of balance readiness

  • Large color touchscreen

  • Detachable display for flexible workstation configuration

  • Approximately 1.2-second settling time

  • Large 205 × 172 mm weighing pan

  • Used, refurbished, calibrated, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Mettler Toledo XPE2002S combines the larger weighing capacity expected from a precision balance with the advanced operating and performance features of Mettler Toledo's Excellence series. Its 2.1 kg capacity and 10 mg readability make it a versatile option for laboratories that need greater capacity than a conventional analytical balance without sacrificing reliable measurement performance.

A high-speed MonoBloc weighing cell supports fast, repeatable measurements, while the balance's approximately 1.2-second settling time can help increase throughput during repetitive weighing procedures.

The XPE2002S also incorporates proFACT automatic internal adjustment, helping compensate for environmental changes that could affect weighing performance. Its StatusLight gives operators an immediate visual indication of balance status, while the large color touchscreen provides straightforward access to weighing results, settings, and operating functions.

Unlike analytical and microbalances that typically rely on enclosed weighing chambers, the XPE2002S uses Mettler Toledo's SmartPan technology to help reduce the effects of air movement while maintaining convenient access to the weighing surface.

Common Applications

The Mettler Toledo XPE2002S is well suited for routine and advanced laboratory weighing where samples, containers, ingredients, or materials may weigh substantially more than the capacity of a typical analytical balance.

Pharmaceutical and biotechnology laboratories can use the XPE2002S for formulation, media and buffer preparation, component weighing, sample preparation, quality-control procedures, and weighing larger containers or batches where 10 mg readability provides sufficient resolution.

Chemical and industrial laboratories may use the balance for reagent preparation, formulation development, compound weighing, batching, percentage weighing, quality assurance, and general quantitative laboratory work.

Its combination of 2.1 kg capacity, 10 mg readability, and rapid stabilization also makes the XPE2002S a useful general-purpose precision balance for research laboratories where both throughput and reliable weighing performance are important.

Ideal Laboratory Types

The XPE2002S is a strong choice for pharmaceutical, biotechnology, chemical, food and beverage, materials science, environmental, academic, industrial research, manufacturing, and quality-control laboratories.

It is particularly useful for laboratories that regularly weigh samples in the tens or hundreds of grams but still require substantially finer resolution than a conventional top-loading scale.

The 2.1 kg capacity also provides flexibility for weighing samples in larger vessels, bottles, beakers, containers, and other laboratory ware without sacrificing the 0.01 g readability needed for many formulation and sample-preparation procedures.

Precision Weighing Performance

The Mettler Toledo XPE2002S provides 10 mg (0.01 g) readability across a 2.1 kg weighing range, offering a useful balance between capacity and resolution.

Typical repeatability is approximately 4 mg, with a specified repeatability limit of 8 mg at nominal load. Mettler Toledo specifies linearity at ±20 mg, while the balance's typical settling time is approximately 1.2 seconds.

This combination is particularly valuable in laboratories performing repetitive weighing procedures. Faster stabilization can reduce the amount of time spent waiting for individual measurements while still providing the repeatable performance expected from a high-quality laboratory precision balance.

For laboratories comparing analytical, semi-micro, micro, and precision balances, the XPE2002S occupies a different role from a high-resolution analytical balance. Rather than prioritizing sub-milligram readability, it provides greater weighing capacity, a larger pan, and fast access to the sample, making it better suited for larger samples and routine formulation or preparation workflows.

Minimum Sample Weight & USP Applications

Maximum capacity and readability alone do not determine whether a balance is suitable for a particular weighing procedure. Laboratories operating under USP requirements should also consider the minimum sample weight necessary to achieve the required measurement uncertainty.

Mettler Toledo lists a typical USP minimum weight of approximately 8.2 g for the XPE2002S under specified conditions.

Actual minimum weight can vary according to balance condition, environmental influences, installation, measurement uncertainty requirements, and laboratory procedures. For regulated or validated applications, minimum weight should therefore be established according to the laboratory's own qualification procedures and applicable quality requirements rather than relying exclusively on a published typical value.

Controlling Drafts, Vibration & Environmental Influences

Although a 10 mg precision balance is less sensitive to environmental disturbances than a microbalance or high-resolution analytical balance, installation conditions can still affect weighing accuracy and repeatability.

Air movement, vibration, temperature changes, unstable work surfaces, and improper leveling can all introduce measurement variation. The XPE2002S incorporates SmartPan technology, which is designed to reduce the effects of air disturbances on the weighing cell while maintaining easy access to the weighing pan.

This design is especially useful for routine laboratory workflows because operators can place and remove samples without repeatedly opening and closing a conventional draft shield.

For best performance, the XPE2002S should be installed on a rigid, level work surface away from strong HVAC airflow, frequently opened doors, direct sunlight, centrifuges, shakers, and other equipment that may transmit vibration through laboratory benches.

Calibration & Internal Adjustment

The XPE2002S incorporates Mettler Toledo's proFACT automatic internal adjustment technology, allowing the balance to perform internal adjustment to help maintain weighing accuracy as laboratory conditions change.

Automatic internal adjustment is useful in laboratories where temperature and environmental conditions may vary during the working day. It also reduces reliance on manually initiated adjustment procedures during routine operation.

Laboratories operating under GLP, GMP, USP, or internal quality systems may still require scheduled performance verification using appropriate traceable test weights and documented calibration procedures. Internal adjustment should therefore be considered one component of a complete balance quality-control program rather than a replacement for laboratory-specific calibration or qualification requirements.

Key Specifications

Specification Mettler Toledo XPE2002S
Balance Type Precision Balance
Maximum Capacity 2.1 kg
Readability 10 mg / 0.01 g
Repeatability 8 mg
Typical Repeatability 4 mg
Typical USP Minimum Weight 8.2 g
Linearity ±20 mg
Settling Time Approx. 1.2 seconds
Adjustment Internal / proFACT
Weighing Pan 205 × 172 mm
Display Detachable color touchscreen
Overall Dimensions 195 mm W × 394 mm D × 97 mm H
Status Monitoring StatusLight
Weighing Pan Technology SmartPan
Legal for Trade No

Choosing Between a Precision Balance and Analytical Balance

A precision balance and analytical balance are designed for different weighing priorities. Choosing between them depends on the smallest quantities that need to be measured accurately, the maximum weight of the sample and container, required measurement uncertainty, and laboratory workflow.

Analytical balances generally provide substantially finer readability—commonly 0.1 mg—but usually have lower maximum capacities and require greater protection from drafts and other environmental influences. Precision balances sacrifice some of that extreme sensitivity in exchange for greater capacity, larger weighing surfaces, faster access, and easier handling of larger samples and containers.

With 2.1 kg capacity and 10 mg readability, the XPE2002S is particularly appropriate for formulation, sample preparation, batching, reagent preparation, and other laboratory procedures where weighing larger quantities accurately is more important than measuring extremely small changes in mass.

Refurbishment & Performance Testing

Every used Mettler Toledo XPE2002S sold by American Instrument Exchange is inspected, cleaned, refurbished as necessary, calibrated, and tested before shipment.

Because weighing performance is the primary function of a precision balance, testing goes beyond simply confirming that the instrument powers on and displays a stable weight. Our technicians evaluate balance operation using appropriate test weights and check critical performance characteristics including accuracy, repeatability, linearity, corner-load tolerances, and reduced span at or near full capacity.

The touchscreen, internal adjustment system, weighing pan, leveling components, display, controls, and other installed features are also inspected and tested for proper operation.

Each refurbished XPE2002S includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation Considerations

Precision balances are sensitive measuring instruments and should be carefully packaged and handled during transportation. The XPE2002S is securely prepared for shipment to protect its weighing mechanism, weighing pan, touchscreen terminal, and other components.

Once installed, the balance should be positioned on a rigid, level, vibration-resistant surface in an area with reasonably stable temperature and minimal air movement. Allowing the balance to acclimate to its new laboratory environment before calibration and use can help improve weighing consistency.

For laboratories performing critical or regulated measurements, installation should be followed by appropriate calibration, verification, or qualification according to the laboratory's quality system.

Related Laboratory Equipment

American Instrument Exchange maintains an extensive inventory of used and refurbished laboratory balances, including analytical balances, semi-micro balances, microbalances, and precision balances for applications ranging from routine sample preparation to high-resolution quantitative analysis.

Labs developing complete analytical or sample-preparation workflows can also source centrifuges, water baths, incubators, laboratory refrigerators, laboratory freezers, and other refurbished laboratory equipment from American Instrument Exchange.

Mettler Toledo XPE2002S Precision Balance FAQs

What is the capacity of the Mettler Toledo XPE2002S?

The XPE2002S has a maximum weighing capacity of 2.1 kg, making it suitable for larger samples, containers, formulation ingredients, and routine laboratory weighing applications.

What is the readability of the XPE2002S?

The Mettler Toledo XPE2002S provides 10 mg, or 0.01 g, readability across its weighing range.

What is the typical repeatability of the XPE2002S?

Mettler Toledo specifies typical repeatability of approximately 4 mg, with a repeatability specification of 8 mg at nominal load.

What is the typical USP minimum weight of the XPE2002S?

Mettler Toledo lists a typical USP minimum weight of approximately 8.2 g under specified conditions. Actual minimum weight should be established according to the installed balance's performance, environmental conditions, measurement uncertainty, and the laboratory's applicable quality procedures.

Does the XPE2002S require a draft shield?

The XPE2002S uses Mettler Toledo's SmartPan weighing pan technology to reduce the effects of air disturbances without requiring the conventional enclosed draft shield associated with high-resolution analytical and microbalances. This provides easier access to larger samples and containers during routine weighing.

Does the Mettler Toledo XPE2002S have automatic internal calibration?

The XPE2002S incorporates proFACT automatic internal adjustment, helping the balance maintain weighing performance as environmental conditions change. Laboratories operating under regulated quality systems may still require documented external verification and calibration procedures.

Is the XPE2002S an analytical balance?

No. The XPE2002S is a precision balance with 2.1 kg capacity and 10 mg readability. It provides greater capacity and easier access to larger samples than a typical analytical balance but does not provide the 0.1 mg or finer readability commonly associated with analytical balances.

What types of laboratories are a good fit for the XPE2002S?

The XPE2002S is well suited for pharmaceutical, biotechnology, chemical, industrial, academic, materials science, manufacturing, and quality-control laboratories. Its combination of capacity, readability, large weighing pan, and fast stabilization makes it particularly useful for formulation, sample preparation, batching, reagent preparation, and general precision weighing.

Why purchase a refurbished Mettler Toledo XPE2002S?

A refurbished XPE2002S provides access to Mettler Toledo's high-quality precision weighing technology without the acquisition cost associated with purchasing comparable new equipment. American Instrument Exchange tests, calibrates, cleans, and refurbishes each balance before shipment and provides a 90-day warranty.

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.