Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Baker SG404M 4' A2 Biosafety Cabinet with Hydraulic Stand

Fully Tested & Warrantied*
Brand : Baker
Product Code : SKU 0877JJ BIO CAB

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Baker SterilGARD e3 SG404M 4' Class II Type A2 Biosafety Cabinet with Hydraulic Stand – Refurbished

Refurbished Baker SG404M Biosafety Cabinet with Height-Adjustable Stand

The Baker SterilGARD e3 SG404M is a premium 4-foot Class II Type A2 biosafety cabinet designed to provide personnel, product, and environmental protection during cell culture, microbiology, biotechnology, pharmaceutical research, and other biological laboratory procedures. Combining Baker's advanced airflow management technology with a spacious stainless steel work chamber and a powered hydraulic height-adjustable stand, the SG404M offers an exceptional combination of biological containment, operator comfort, and energy efficiency.

Part of Baker's SterilGARD e3 series, the SG404M incorporates StediFLOW self-adjusting motor technology, ReadySAFE energy-saving operation, and a 12-inch working sash opening. These features help maintain dependable airflow performance while providing additional working clearance and convenient operation.

This refurbished cabinet, American Instrument Exchange SKU 0877JJ BIO CAB, includes a fully adjustable, electronically controlled hydraulic stand that allows the work-surface height to be positioned from approximately 20 to 38.63 inches. The adjustable stand makes the cabinet particularly useful in laboratories where researchers alternate between seated and standing work or where multiple operators require different working heights.

The 4-foot cabinet provides a nominal 46-inch-wide interior chamber, offering ample space for culture vessels, sample racks, pipettes, aspiration equipment, and other laboratory materials.

American Instrument Exchange professionally refurbishes and tests used biosafety cabinets before shipment. This SG404M configuration includes new supply and exhaust HEPA filters and is backed by a 90-day warranty.

For laboratories seeking a refurbished Baker SG404M or a comparable 4-foot Class II Type A2 biosafety cabinet, American Instrument Exchange can assist with equipment availability, specifications, and replacement options.

Key Features

  • Baker SterilGARD e3 SG404M Class II Type A2 biosafety cabinet

  • 4-foot nominal cabinet width

  • 12-inch certified working sash opening

  • Electronically controlled hydraulic height-adjustable stand included

  • Work-surface height adjustable from approximately 20 to 38.63 inches

  • StediFLOW self-adjusting motor technology

  • ReadySAFE energy-saving operating mode

  • HEPA-filtered supply and exhaust airflow

  • New supply and exhaust HEPA filters included

  • Nominal 46-inch-wide interior work chamber

  • Approximately 44-inch-wide usable work surface

  • Stainless steel interior and work surface

  • Angled viewscreen for improved operator visibility

  • Ergonomic padded front armrest

  • Automatic compensation for increasing HEPA filter resistance

  • Audible and visual operating alarms

  • Membrane-style operator control panel

  • Right-side cable and tubing access port

  • Interior electrical receptacles

  • Low-vibration blower assembly

  • NSF/ANSI 49 Class II Type A2 design

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Baker SterilGARD e3 SG404M is designed for laboratories requiring dependable biological containment, a comfortable working environment, and efficient operation.

As a Class II Type A2 biosafety cabinet, the SG404M uses inward airflow at the front opening to help protect laboratory personnel from potentially hazardous biological aerosols. HEPA-filtered vertical downflow provides product protection within the work chamber, while HEPA-filtered exhaust helps protect the surrounding environment.

The cabinet's airflow management system incorporates Baker's StediFLOW technology, which automatically adjusts blower operation as HEPA filter resistance changes. This helps maintain the designed airflow profile throughout normal operation.

The SterilGARD e3 platform also incorporates ReadySAFE mode, an energy-saving operating feature that allows the cabinet to maintain protective airflow conditions with the viewscreen closed.

These features distinguish the SG404M from older biosafety cabinets that rely on conventional fixed-speed blower systems and offer fewer energy-management capabilities.

The included hydraulic stand adds another important advantage. Rather than requiring operators to adapt to a fixed working height, the cabinet can be adjusted to accommodate different users and laboratory procedures.

For facilities outfitting new laboratories, replacing older biosafety cabinets, or expanding biological research capacity, the Baker SG404M offers a versatile and ergonomic Class II Type A2 containment workstation.

Powered Hydraulic Height-Adjustable Stand

One of the most valuable features of this refurbished Baker SG404M is its electronically controlled hydraulic stand.

The stand allows the cabinet's work surface to be raised or lowered through a range of approximately 20 to 38.63 inches, providing flexibility for seated and standing laboratory work.

This adjustment capability can be especially beneficial in shared laboratories where multiple researchers use the same biosafety cabinet.

Operators can position the work surface at a comfortable height for pipetting, cell culture, sample preparation, and other repetitive procedures.

The hydraulic stand also helps laboratories accommodate different seating arrangements, ergonomic preferences, and accessibility requirements.

Unlike a conventional fixed-height base stand, the powered hydraulic system provides convenient adjustment without requiring the cabinet to be manually lifted or repositioned.

The stand is an important consideration when comparing refurbished SG404M cabinets because not every SterilGARD e3 configuration includes a powered height-adjustable base.

For laboratories where operator comfort and workstation flexibility are priorities, this feature can provide substantial long-term value.

StediFLOW Self-Adjusting Airflow Technology

The Baker SterilGARD e3 SG404M incorporates StediFLOW self-adjusting motor technology, designed to support consistent airflow performance while improving energy efficiency.

As HEPA filters accumulate particulate material during normal operation, resistance to airflow gradually increases.

StediFLOW automatically adjusts motor performance to compensate for these changes and help maintain the cabinet's intended airflow conditions.

This approach reduces the need for excessive blower operation when filters are relatively clean while providing additional motor output as filtration resistance increases.

Baker developed the SterilGARD e3 platform to combine biological containment with improved energy efficiency and reduced operating noise.

The manufacturer reports energy-efficiency improvements of up to 60% compared with certain conventional biosafety cabinet designs, depending on the comparison and operating conditions.

For laboratories operating multiple biosafety cabinets or using equipment for extended periods, improved energy efficiency can contribute to lower electrical consumption and reduced heat generation.

StediFLOW does not replace routine field certification, but it provides an important level of automatic airflow compensation between scheduled certification visits.

ReadySAFE Energy-Saving Operation

ReadySAFE is another distinguishing feature of the Baker SterilGARD e3 platform.

This operating mode allows the cabinet to maintain protective airflow conditions with the viewscreen closed while reducing energy consumption during periods when the work chamber is not actively being used.

ReadySAFE can be useful during laboratory breaks, between procedures, or overnight when the cabinet remains powered but is not occupied.

When the viewscreen is returned to its normal working position, the cabinet resumes its standard operating airflow.

This feature can help reduce unnecessary energy consumption and filter loading while supporting efficient laboratory operation.

ReadySAFE should not be interpreted as a substitute for appropriate cleaning, decontamination, or laboratory shutdown procedures.

12-Inch Working Sash Opening

The SG404M features a nominal 12-inch working sash opening, providing greater vertical access than many Class II Type A2 cabinets equipped with 8-inch or 10-inch operating apertures.

The additional opening height can be particularly useful when working with taller culture vessels, sample racks, and compatible laboratory equipment.

The cabinet incorporates an angled viewscreen designed to improve visibility and operator comfort.

The front armrest provides additional ergonomic support during extended laboratory procedures.

The cabinet must be operated at its designated working sash position during biological procedures. Raising the viewscreen beyond the certified working opening can alter the protective airflow conditions at the front of the cabinet.

After installation, the SG404M should be field certified at its intended operating sash height before biological use.

Stainless Steel Interior & Work Surface

The Baker SG404M incorporates a stainless steel work chamber designed for durability, cleanability, and routine biological laboratory use.

The nominal interior chamber measures approximately 46 inches wide, 24.56 inches deep, and 27.44 inches high.

The usable work surface measures approximately 44 inches wide by 19.63 inches deep.

This provides substantial room for routine cell culture, microbiology, molecular biology, and pharmaceutical research procedures.

The stainless steel construction supports regular cleaning and disinfection, while the interior layout allows researchers to organize materials within the HEPA-filtered working area.

For laboratories performing frequent biological procedures, maintaining an organized workspace and unobstructed airflow openings is essential to dependable containment performance.

Right-Side Cable & Tubing Access Port

The Baker SterilGARD e3 SG404M includes a right-side access port designed to accommodate compatible electrical cables, aspiration tubing, and other laboratory connections.

The port incorporates flexible sealing components that allow appropriately sized cables or tubing to pass through the cabinet wall.

This can be particularly useful when operating aspiration equipment, monitoring instruments, or other compatible devices inside the work chamber.

Using a designated access port helps avoid routing cables through the front sash opening, where they could interfere with the intended protective airflow pattern.

Utility connections should be installed according to the manufacturer's instructions and should not compromise cabinet containment performance.

Operator Controls & Safety Alarms

The SG404M incorporates a membrane-style operator control panel with push-button controls for essential cabinet functions.

The control system provides access to blower operation, work-area lighting, electrical receptacles, alarm functions, and optional equipment where installed.

Audible and visual alarms help alert operators to certain unsafe or abnormal operating conditions.

These include viewscreen-position alarms, power or processor faults, and certain viewscreen sensor faults.

The blower and motor assembly is designed to minimize vibration and provide dependable operation.

For laboratories where multiple researchers share a biosafety cabinet, straightforward controls and clearly communicated alarms help support consistent equipment use.

Common Applications

The Baker SterilGARD e3 SG404M is well suited to mammalian cell culture, tissue culture, stem cell research, microbiology, molecular biology, virology, biotechnology, vaccine development, pharmaceutical research, and other procedures requiring Class II Type A2 biological containment.

Its 12-inch working sash opening provides additional vertical clearance, while the hydraulic stand makes the cabinet particularly attractive for laboratories where operators alternate between seated and standing work.

The 4-foot chamber provides sufficient room for many routine biological procedures without requiring the larger laboratory footprint of a 5- or 6-foot cabinet.

Ideal Laboratory Environments

The Baker SG404M is an excellent choice for biotechnology companies, pharmaceutical research facilities, university laboratories, hospital research departments, clinical research organizations, microbiology laboratories, and other life-science institutions.

Its combination of StediFLOW airflow management, ReadySAFE operation, a spacious stainless steel chamber, and a powered hydraulic stand makes it especially suitable for laboratories seeking both biological containment and operator comfort.

The cabinet can also be a practical choice for facilities replacing older fixed-height biosafety cabinets with more ergonomic equipment.

Key Specifications

Specification Details
Manufacturer The Baker Company
Model SterilGARD e3 SG404M
AIE SKU 0877JJ BIO CAB
Condition Used and Refurbished
Cabinet Classification Class II Type A2
Nominal Width 4 ft
Exterior Dimensions, Cabinet Only 53.75" W × 30.5–30.69" D × 61.75" H
Interior Chamber Dimensions 46" W × 24.56" D × 27.44" H
Usable Work Surface 44" W × 19.63" D
Working Sash Opening 12"
Maximum Sash Opening Approximately 20"
Interior Construction Stainless Steel
Airflow Management StediFLOW
Energy-Saving Operation ReadySAFE
Supply Filtration HEPA
Exhaust Filtration HEPA
Included Filters New Supply and Exhaust HEPA Filters
Exhaust Configuration Class II Type A2, HEPA-Filtered
Operator Controls Membrane Switch Panel
Safety Alarms Audible and Visual
Lighting Fluorescent Work Light
Utility Access Right-Side Cable and Tubing Port
Stand Powered Hydraulic Height-Adjustable Stand
Work-Surface Height Range Approximately 20"–38.63"
Cabinet Weight Without Stand Approximately 582–585 lb
Approximate Weight with Hydraulic Stand 792 lb, Based on Manufacturer Configuration
Electrical 115V, 60 Hz
Electrical Service Verify Nameplate; AIE Lists 15A
Warranty 90 Days from American Instrument Exchange
Availability Contact AIE for Current Inventory

Specifications are compiled from Baker manufacturer literature and American Instrument Exchange product information. The 20–38.63-inch hydraulic adjustment range and included new HEPA filters are specific to AIE's listed configuration. Actual dimensions, electrical requirements, stand operation, and accessories should be confirmed for the individual refurbished unit.

Why Buy a Refurbished Baker SG404M from American Instrument Exchange?

The Baker SterilGARD e3 SG404M combines the proven biological containment capabilities of a Class II Type A2 biosafety cabinet with energy-efficient airflow management and an ergonomic powered hydraulic stand.

Its StediFLOW motor technology, ReadySAFE operating mode, 12-inch working sash opening, and stainless steel interior make it an attractive choice for laboratories requiring dependable performance and operator comfort.

American Instrument Exchange currently has two refurbished Baker SG404M biosafety cabinets available, each equipped with a powered hydraulic height-adjustable stand and new supply and exhaust HEPA filters.

Both cabinets are professionally refurbished and tested by American Instrument Exchange and include a 90-day warranty.

With two units recently received, laboratories seeking matching biosafety cabinets for multiple workstations or research areas have an opportunity to purchase the same model and configuration.

For laboratories seeking a refurbished 4-foot Baker biosafety cabinet with a hydraulic height-adjustable stand, the SG404M offers an excellent combination of containment technology, ergonomics, energy efficiency, and long-term value.

Click here to see the Baker SG404M on the American Instrument Exchange YouTube channel. 

Testing Procedures for Used and Refurbished Biosafety Cabinets

Ensure Containment, Airflow Integrity, and Operator Safety

Used and refurbished biosafety cabinets (BSCs) from American Instrument Exchange are thoroughly tested to ensure they meet NSF/ANSI 49 performance standards for containment, airflow uniformity, and HEPA filtration. Each Class I, II, or III unit is evaluated through a series of specialized inspections and certifications, ensuring the cabinet performs reliably in research, clinical, and pharmaceutical lab environments.

Why Testing Used Biosafety Cabinets Is Essential

Before any biosafety cabinet is deployed in a working lab, it must be tested for:

• HEPA filter integrity and leak-free performance
• Inflow and downflow air velocity balance
• Containment efficiency and personnel protection
• Electrical system function and safety compliance
• Cleanliness and readiness for sterile applications

Proper testing of refurbished biosafety cabinets helps prevent cross-contamination, exposure to hazardous materials, and airflow disruption—critical for maintaining laboratory protocols. Our structured multi-point BSC testing protocol ensures dependable protection for operators, products, and the lab environment.

Key Testing Procedures for Refurbished and Used Biosafety Cabinets

1. Initial Visual Inspection

• Inspect exterior panels, window sashes, hinges, and seals for signs of wear or damage
• Confirm visibility and integrity of the viewing window
• Check power cords, display screens, and control interfaces for usability

2. Cabinet Decontamination and Cleaning

• Interior and exterior cleaned with non-corrosive disinfectants
• Decontamination protocols followed to remove biological contaminants
• Work surface, sidewalls, and return air grills are fully sanitized

3. HEPA Filter Integrity Testing (DOP/PAO Leak Test)

• Conduct aerosol challenge test using PAO or DOP to verify HEPA filter seal integrity
• Identify and resolve any filter leaks in accordance with NSF/ANSI 49 standards
• Ensure HEPA filters are correctly seated and uncompromised

4. Inflow and Downflow Velocity Testing

• Measure air velocities using calibrated thermo-anemometers
• Confirm inflow velocity meets requirements
• Verify downflow uniformity within the work zone to prevent turbulence and contamination

5. Airflow Smoke Pattern Testing

• Conduct visual smoke tests to demonstrate laminar airflow and containment
• Confirm that airflow barriers prevent cross-contamination and exposure

6. Electrical Safety and Alarm System Checks

• Inspect grounding, insulation resistance, and GFCI protection
• Test alarm functionality for sash position, airflow disruption, and power failure
• Verify interior lighting, outlets, and blower controls operate reliably

7. Final Certification and Quality Assurance

• Run full performance test cycle and confirm compliance with NSF/ANSI 49 and manufacturer specs
• Document data and generate a detailed service report

Guaranteed Performance from American Instrument Exchange

All refurbished biosafety cabinets from American Instrument Exchange are tested and verified to ensure maximum containment, user protection, and airflow performance. Whether used for microbiology, tissue culture, pharmaceutical compounding, or other work necessitating containment, our BSCs meet industry standards—so your team can work safely and confidently from day one.

Repair and Refurbishment Protocol for Used Biosafety Cabinets

Certified Protection and Performance from American Instrument Exchange

At American Instrument Exchange, every used biosafety cabinet (BSC) we offer is thoroughly repaired and refurbished to meet the highest standards for safety, airflow performance, and compliance. Whether it’s a Class I, Class II Type A2/B2, or Class III unit, we follow a meticulous refurbishment process to ensure your BSC provides reliable containment, sterile workspace conditions, and long-term durability.

Why Choose a Refurbished Biosafety Cabinet from American Instrument Exchange?

  • Fully tested and certified for airflow integrity and containment
  • Backed by warranty and performance guarantee
  • Cost-effective alternative to new biosafety cabinets
  • Environmentally responsible through expert reuse and restoration
  • Serviced by experienced technicians trained in NSF/ANSI 49 protocols

Step-by-Step Refurbishment Protocol

Every biosafety cabinet at American Instrument Exchange undergoes the following comprehensive multi-stage process to ensure it is lab-ready:

1. Initial Intake & Inspection

• Visual inspection of cabinet exterior, control panel, and sash mechanism
• Evaluation of hinges, seals, gaskets, and electrical components
• Missing parts or functional issues are documented for repair

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, disinfectant-safe products
• Decontamination protocols followed to remove biohazardous or chemical residue
• Removable surfaces, work trays, and grilles are cleaned and sanitized

3. Mechanical and Electrical Repair

• Repair or replacement of worn components, including sash latches, lighting, and controls
• Electrical systems including switches, alarms, and outlets are tested and serviced
• Wiring is inspected and repaired to meet safety and performance standards

4. HEPA Filter Evaluation and Replacement

• Filters are tested for integrity using DOP/PAO aerosol challenge testing
• HEPA filters are replaced with OEM or equivalent filters
• Filter seals are verified for leak-free performance

5. Airflow and Performance Testing

• Inflow and downflow velocities are measured using calibrated instruments
• Smoke pattern testing confirms laminar airflow and containment effectiveness
• Blower motor function and airflow uniformity are verified across the cabinet

6. Safety System Verification

• Alarms for airflow disruption, sash height, and power loss are tested
• GFCI protection, lighting, and emergency shutoff systems are confirmed functional

7. Final Quality Control and Certification

• Performance testing is conducted to confirm NSF/ANSI 49 compliance (where applicable)
• Final visual inspection and cleaning performed prior to shipping
• Detailed service report and airflow test results provided with each unit

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the lab equipment industry, American Instrument Exchange is a trusted name in refurbished biosafety cabinets. Our repair and refurbishment protocol ensures each cabinet provides dependable protection for personnel, products, and the environment—delivering maximum safety at a fraction of the cost of new.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.