Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Baker SterilGARD e3 SG504 Biosafety Cabinet

Fully Tested & Warrantied*
Brand : Baker
Product Code : SKU 0877M BIO CAB

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Baker SterilGARD e3 SG504 Class II Type A2 Biosafety Cabinet

Refurbished Baker SterilGARD e3 SG504 Biosafety Cabinet for Sale

The Baker SterilGARD e3 SG504 is a 5-foot Class II Type A2 biosafety cabinet designed to provide exceptional personnel, product, and environmental protection for laboratories performing contamination-sensitive biological research. Combining Baker's proven airflow technology with energy-efficient engineering and ergonomic design, the SG504 is an excellent choice for biotechnology companies, pharmaceutical manufacturers, hospital laboratories, academic research institutions, and clinical diagnostic facilities that require a larger biological safety cabinet for demanding laboratory workflows.

With its expanded 5-foot work area, the SG504 offers additional workspace for larger culture vessels, multiple operators during training or collaborative procedures, and laboratory workflows involving numerous samples or instruments. The cabinet maintains ISO Class 5 product protection through HEPA-filtered vertical laminar airflow while protecting laboratory personnel from potentially hazardous aerosols and preventing contaminants from entering the surrounding laboratory environment.

At American Instrument Exchange, every Baker SG504 biosafety cabinet is inspected and tested by our technicians before shipment. Unless otherwise specified, new HEPA filters are installed at our facility prior to delivery. Laboratories outfitting new research facilities or expanding existing laboratories may also browse our inventory of refurbished biosafety cabinets, CO₂ incubators, centrifuges, laboratory refrigerators, ultra-low temperature freezers, and other laboratory equipment to build a complete workflow from a single supplier.


Key Features

  • Class II Type A2 biosafety cabinet

  • Approximately 5-foot nominal cabinet width

  • Large interior workspace for high-throughput laboratory procedures

  • Vertical laminar airflow with HEPA-filtered supply and exhaust air

  • Baker SterilGARD e3 airflow technology

  • Energy-efficient electronically commutated (ECM) blower motor

  • ReadySAFE standby operating mode

  • Ergonomic 10-degree sloped front sash

  • LED work area illumination

  • Digital airflow monitoring and cabinet controls

  • Designed for continuous operation in research, pharmaceutical, and clinical laboratories


Overview

The Baker SterilGARD e3 SG504 was engineered for laboratories that require additional workspace without compromising biological containment. Built around Baker's advanced airflow system and electronically commutated blower technology, the SG504 delivers stable airflow performance while consuming significantly less energy than many earlier-generation biosafety cabinets.

As a Class II Type A2 biosafety cabinet, the SG504 utilizes inward airflow to protect laboratory personnel while HEPA-filtered vertical laminar airflow protects biological samples from contamination. HEPA-filtered exhaust air safeguards the laboratory environment, making the cabinet appropriate for a wide range of microbiological, pharmaceutical, and biotechnology applications.

The cabinet's larger work area is particularly valuable for laboratories processing high sample volumes or working with larger laboratory equipment inside the cabinet. Whether preparing tissue culture flasks, organizing multiple sample racks, or performing pharmaceutical quality control procedures, the SG504 provides the additional workspace needed to improve laboratory efficiency while maintaining excellent contamination control.

Combined with Baker's ReadySAFE standby mode, quiet ECM blower motor, and ergonomically designed front sash, the SG504 delivers dependable containment performance while helping laboratories reduce long-term operating costs.


Why Choose the Baker SG504?

Many laboratories eventually outgrow a standard 4-foot biosafety cabinet. The Baker SG504 provides approximately one additional foot of usable workspace, giving researchers greater flexibility for complex procedures without requiring a larger laboratory footprint than many competing 5-foot cabinets.

The SG504's expanded work surface makes it easier to organize multiple culture vessels, pipettes, reagent containers, and laboratory instruments while maintaining proper aseptic technique. Laboratories processing larger batches of samples or performing repetitive cell culture procedures often find that the increased workspace improves both productivity and operator comfort.

Another significant advantage is Baker's use of an electronically commutated (ECM) blower motor, which automatically maintains proper airflow as filter loading changes over time. Compared with conventional blower systems, ECM technology improves airflow stability while reducing electrical consumption and extending blower efficiency.

The cabinet also incorporates Baker's ReadySAFE standby mode, allowing laboratories to reduce energy usage during periods of inactivity while maintaining a clean work environment. Combined with the ergonomic 10-degree sloped sash, LED lighting, and intuitive digital controls, these features make the SG504 an excellent long-term investment for laboratories seeking dependable biological containment and lower operating costs.


Baker SG504 vs. Older Baker Biosafety Cabinets

The Baker SG504 represents a substantial advancement over previous generations of SterilGARD biosafety cabinets. While earlier Baker cabinets established an excellent reputation for durability and contamination control, the SG504 incorporates numerous improvements designed to reduce operating costs, simplify operation, and enhance user comfort.

One of the most significant upgrades is the incorporation of an electronically commutated (ECM) blower motor, which continuously adjusts blower speed to maintain proper airflow as HEPA filters gradually load during normal operation. This technology provides more consistent airflow while consuming considerably less electricity than traditional blower motors used in many legacy biosafety cabinets.

The SG504 also incorporates Baker's energy-saving standby operating mode, ergonomic front sash design, bright LED lighting, and modern digital monitoring system. Laboratories replacing older SterilGARD cabinets can often reduce operating costs while benefiting from quieter operation, improved airflow control, and enhanced operator ergonomics without changing established laboratory workflows.


Compatible Laboratory Equipment

The Baker SG504 is commonly installed alongside other laboratory instruments that support sterile biological research and pharmaceutical production. Its larger workspace makes it particularly well suited for laboratories operating multiple incubators, centrifuges, and cold storage units while processing higher sample volumes.

Many laboratories pair the SG504 with CO₂ incubators for mammalian cell culture, refrigerated centrifuges for sample preparation, ultra-low temperature freezers for long-term specimen storage, laboratory refrigerators for media and reagent storage, compound and inverted microscopes for routine cell analysis, and laboratory autoclaves for sterilizing instruments and biological waste.

American Instrument Exchange offers a comprehensive inventory of professionally refurbished laboratory equipment, allowing laboratories to source multiple compatible instruments from one trusted supplier while reducing procurement lead times and simplifying laboratory expansion projects.


Common Applications

The Baker SG504 is designed for laboratories requiring a larger biological safety cabinet to support demanding research and production workflows.

Typical applications include:

  • Mammalian cell culture

  • Stem cell research

  • Tissue engineering

  • Pharmaceutical quality control

  • Vaccine development

  • Molecular biology

  • Virology

  • Microbiology

  • Clinical diagnostics

  • Gene therapy research

  • Biopharmaceutical manufacturing support

  • Biotechnology product development

  • Academic and government research laboratories


Ideal Laboratory Environments

The SG504 is frequently selected by biotechnology companies, pharmaceutical manufacturers, university research laboratories, hospital pathology departments, public health laboratories, and contract research organizations that require additional workspace while maintaining Class II Type A2 biosafety protection.

Its larger interior dimensions make it especially well suited for laboratories handling higher sample throughput, larger culture vessels, or procedures requiring multiple pieces of equipment inside the work area. The combination of dependable airflow performance, energy-efficient operation, and ergonomic design allows the SG504 to support continuous daily operation in demanding research and production environments.


Key Specifications

Specification Details
Manufacturer Baker
Model SterilGARD e3 SG504
Cabinet Type Class II Type A2 Biosafety Cabinet
Nominal Width 5 ft
Interior Dimensions 58" W × 24.6" D × 27.4" H
Usable Work Area 56" W × 19.6" D
Exterior Dimensions 65.8" W × 30.7" D × 61.8" H
Airflow Vertical Laminar Flow
Supply Filtration HEPA
Exhaust Filtration HEPA
Blower Motor Electronically Commutated (ECM)
Operating Mode ReadySAFE Standby
Lighting LED
Weight Approximately 714 lb
Electrical 115V, 60 Hz (model dependent)

Specifications compiled from Baker manufacturer literature, distributor technical references, and American Instrument Exchange product information.

What is the Baker SterilGARD e3 SG504 biosafety cabinet?

The Baker SterilGARD e3 SG504 is a Class II Type A2 biosafety cabinet designed to provide personnel, product, and environmental protection through controlled airflow and HEPA filtration. It meets NSF/ANSI 49 standards and is suitable for Biosafety Levels 1–3 applications including microbiology, virology, and pharmaceutical work.

If you’re not sure what type of biosafety cabinet you need – Type A2 or Type B2 – please contact either the sales team at American Instrument Exchange or the technicians at AIE Laboratory Services for more information and guidance.

How does the airflow system in the SG504 work?

Like all Class II Type A2 biosafety cabinet, the Baker SG504 uses a vertical laminar airflow system with a carefully balanced recirculation pattern:

  • Room air enters at ~100–105 feet per minute through the front opening
  • HEPA-filtered air flows downward in a unidirectional stream
  • ~70% of air is recirculated; ~30% is exhausted through a HEPA filter
  • A momentum air curtain and high-velocity return slots enhance containment

This design ensures contaminants are captured while maintaining a sterile work area.

What level of filtration does the SG504 provide?

The cabinet uses dual HEPA filters (supply and exhaust) that are:

  • 99.99% efficient at 0.3 microns (most penetrating particle size)
  • Individually leak-tested before shipment
  • Designed for both product and environmental protection

This level of filtration is critical for maintaining sterile conditions in sensitive lab workflows.

What makes the SterilGARD e3 series unique compared to other biosafety cabinets?

The SG504 and other Baker x04 biosafety cabinets incorporate several proprietary technologies, including:

  • StediFLOW™ airflow system for consistent performance as filters load
  • UniPressure™ plenum design for stable airflow balance
  • Momentum air curtain for improved operator protection
  • High-velocity return air slots to capture contaminants quickly

These features work together to improve containment, reduce turbulence, and simplify certification.

How energy efficient is the SG504 biosafety cabinet?

The SterilGARD e3 platform is engineered for low energy consumption and reduced operating costs, offering:

  • Significant reductions in energy use compared to traditional cabinets
  • Lower heat output, improving lab comfort
  • Extended HEPA filter life due to optimized airflow

Some configurations report substantial annual energy savings due to efficient motor and airflow control systems.

Can the SG504 be ducted or used recirculating?

Yes. Like all Class II Type A2 cabinets, the SG504 can recirculate air back into the laboratory or connect to an external exhaust system via a canopy. This flexibility allows it to fit a wide range of lab designs and safety requirements.

What applications is the SG504 best suited for?

The SG504 is commonly used in cell and tissue culture, microbiology and virology labs,  clinical diagnostics, pharmaceutical and biotech research, and more. It is designed for applications requiring both contamination control and operator protection.

How easy is maintenance and certification?

The SterilGARD e3 is designed for simplified maintenance. Our repair technicians appreciate all of the features that make these units easy to maintain, including front-access HEPA filters for faster replacement, adjustable internal damper for airflow balancing, accessible components for certification testing. These features reduce downtime and service costs over the life of the cabinet.

Why buy a refurbished SG504 instead of new?

A professionally refurbished SG504 can deliver:

  • Significant cost savings compared to new units
  • Verified performance and tested airflow systems
  • Faster availability vs. long OEM lead times

When properly refurbished, these cabinets provide equivalent functional performance at a fraction of the cost.

Why choose American Instrument Exchange instead of an auction or unknown seller?

Not all “used biosafety cabinets” are equal. Buying from a trusted supplier like American Instrument Exchange helps ensure:

  • Verified HEPA filter integrity and airflow performance
  • Proper decontamination and cleaning
  • Functional alarms, controls, and safety systems
  • Reduced risk of certification failure after delivery

In contrast, auction equipment is often sold untested, uncertified, and without safety validation, which can lead to costly repairs or compliance issues.

 

Testing Procedures for Used and Refurbished Biosafety Cabinets

Ensure Containment, Airflow Integrity, and Operator Safety

Used and refurbished biosafety cabinets (BSCs) from American Instrument Exchange are thoroughly tested to ensure they meet NSF/ANSI 49 performance standards for containment, airflow uniformity, and HEPA filtration. Each Class I, II, or III unit is evaluated through a series of specialized inspections and certifications, ensuring the cabinet performs reliably in research, clinical, and pharmaceutical lab environments.

Why Testing Used Biosafety Cabinets Is Essential

Before any biosafety cabinet is deployed in a working lab, it must be tested for:

• HEPA filter integrity and leak-free performance
• Inflow and downflow air velocity balance
• Containment efficiency and personnel protection
• Electrical system function and safety compliance
• Cleanliness and readiness for sterile applications

Proper testing of refurbished biosafety cabinets helps prevent cross-contamination, exposure to hazardous materials, and airflow disruption—critical for maintaining laboratory protocols. Our structured multi-point BSC testing protocol ensures dependable protection for operators, products, and the lab environment.

Key Testing Procedures for Refurbished and Used Biosafety Cabinets

1. Initial Visual Inspection

• Inspect exterior panels, window sashes, hinges, and seals for signs of wear or damage
• Confirm visibility and integrity of the viewing window
• Check power cords, display screens, and control interfaces for usability

2. Cabinet Decontamination and Cleaning

• Interior and exterior cleaned with non-corrosive disinfectants
• Decontamination protocols followed to remove biological contaminants
• Work surface, sidewalls, and return air grills are fully sanitized

3. HEPA Filter Integrity Testing (DOP/PAO Leak Test)

• Conduct aerosol challenge test using PAO or DOP to verify HEPA filter seal integrity
• Identify and resolve any filter leaks in accordance with NSF/ANSI 49 standards
• Ensure HEPA filters are correctly seated and uncompromised

4. Inflow and Downflow Velocity Testing

• Measure air velocities using calibrated thermo-anemometers
• Confirm inflow velocity meets requirements
• Verify downflow uniformity within the work zone to prevent turbulence and contamination

5. Airflow Smoke Pattern Testing

• Conduct visual smoke tests to demonstrate laminar airflow and containment
• Confirm that airflow barriers prevent cross-contamination and exposure

6. Electrical Safety and Alarm System Checks

• Inspect grounding, insulation resistance, and GFCI protection
• Test alarm functionality for sash position, airflow disruption, and power failure
• Verify interior lighting, outlets, and blower controls operate reliably

7. Final Certification and Quality Assurance

• Run full performance test cycle and confirm compliance with NSF/ANSI 49 and manufacturer specs
• Document data and generate a detailed service report

Guaranteed Performance from American Instrument Exchange

All refurbished biosafety cabinets from American Instrument Exchange are tested and verified to ensure maximum containment, user protection, and airflow performance. Whether used for microbiology, tissue culture, pharmaceutical compounding, or other work necessitating containment, our BSCs meet industry standards—so your team can work safely and confidently from day one.

Repair and Refurbishment Protocol for Used Biosafety Cabinets

Certified Protection and Performance from American Instrument Exchange

At American Instrument Exchange, every used biosafety cabinet (BSC) we offer is thoroughly repaired and refurbished to meet the highest standards for safety, airflow performance, and compliance. Whether it’s a Class I, Class II Type A2/B2, or Class III unit, we follow a meticulous refurbishment process to ensure your BSC provides reliable containment, sterile workspace conditions, and long-term durability.

Why Choose a Refurbished Biosafety Cabinet from American Instrument Exchange?

  • Fully tested and certified for airflow integrity and containment
  • Backed by warranty and performance guarantee
  • Cost-effective alternative to new biosafety cabinets
  • Environmentally responsible through expert reuse and restoration
  • Serviced by experienced technicians trained in NSF/ANSI 49 protocols

Step-by-Step Refurbishment Protocol

Every biosafety cabinet at American Instrument Exchange undergoes the following comprehensive multi-stage process to ensure it is lab-ready:

1. Initial Intake & Inspection

• Visual inspection of cabinet exterior, control panel, and sash mechanism
• Evaluation of hinges, seals, gaskets, and electrical components
• Missing parts or functional issues are documented for repair

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, disinfectant-safe products
• Decontamination protocols followed to remove biohazardous or chemical residue
• Removable surfaces, work trays, and grilles are cleaned and sanitized

3. Mechanical and Electrical Repair

• Repair or replacement of worn components, including sash latches, lighting, and controls
• Electrical systems including switches, alarms, and outlets are tested and serviced
• Wiring is inspected and repaired to meet safety and performance standards

4. HEPA Filter Evaluation and Replacement

• Filters are tested for integrity using DOP/PAO aerosol challenge testing
• HEPA filters are replaced with OEM or equivalent filters
• Filter seals are verified for leak-free performance

5. Airflow and Performance Testing

• Inflow and downflow velocities are measured using calibrated instruments
• Smoke pattern testing confirms laminar airflow and containment effectiveness
• Blower motor function and airflow uniformity are verified across the cabinet

6. Safety System Verification

• Alarms for airflow disruption, sash height, and power loss are tested
• GFCI protection, lighting, and emergency shutoff systems are confirmed functional

7. Final Quality Control and Certification

• Performance testing is conducted to confirm NSF/ANSI 49 compliance (where applicable)
• Final visual inspection and cleaning performed prior to shipping
• Detailed service report and airflow test results provided with each unit

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the lab equipment industry, American Instrument Exchange is a trusted name in refurbished biosafety cabinets. Our repair and refurbishment protocol ensures each cabinet provides dependable protection for personnel, products, and the environment—delivering maximum safety at a fraction of the cost of new.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.