Eppendorf 5810R with A-4-62 rotor
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Eppendorf 5810R Refrigerated Benchtop Centrifuge is a versatile refrigerated laboratory centrifuge designed for biotechnology laboratories, pharmaceutical research, clinical laboratories, cell culture applications, blood processing workflows, and general laboratory sample preparation. This particular configuration includes the Eppendorf A-4-62 swinging bucket rotor, providing flexible processing capability for conical tubes, blood tubes, bottles, and routine laboratory centrifugation workflows. The A-4-62 rotor is one of the most widely recognized rotor configurations for the 5810R platform due to its versatility and broad compatibility with common laboratory sample formats.
Laboratories evaluating refrigerated benchtop centrifuges often compare refrigeration performance, rotor flexibility, throughput capability, maximum RPM and RCF performance, and workflow versatility when selecting a centrifuge system. The Eppendorf 5810R is engineered specifically for laboratories requiring reliable refrigerated centrifugation across multiple applications while maintaining a compact laboratory footprint. This particular unit represents an earlier-generation 5810R design that continues to be widely used in research, biotechnology, and clinical laboratories due to its proven reliability and straightforward operation.
At American Instrument Exchange, our technicians inspect and test each centrifuge to verify proper refrigeration performance, motor operation, braking systems, lid lock functionality, rotor operation, and controller performance prior to shipment. American Instrument Exchange offers used and refurbished laboratory centrifuges for sale, including refrigerated centrifuges, floor model centrifuges, benchtop centrifuges, and large-capacity bioprocessing centrifuge systems from leading manufacturers including Thermo Scientific, Beckman Coulter, Eppendorf, and more.
The Eppendorf 5810R combines refrigeration performance, flexible sample processing capability, and dependable operation, making it one of the most popular general-purpose refrigerated centrifuges in laboratory environments.
The Eppendorf 5810R is a refrigerated benchtop centrifuge optimized for biotechnology workflows, cell culture applications, clinical sample preparation, microbiology research, pharmaceutical laboratories, and routine laboratory centrifugation procedures. Unlike microcentrifuges designed exclusively for small-volume tubes, the 5810R platform supports a wide range of sample formats and rotor configurations, allowing laboratories to process larger volumes and multiple vessel types efficiently.
The included A-4-62 swinging bucket rotor supports blood collection tubes, conical tubes, bottles, and other laboratory vessels through the use of interchangeable adapters. The refrigerated chamber helps maintain stable sample temperatures throughout centrifugation, making the system especially valuable for biologic samples, proteins, enzymes, cell culture media, and other temperature-sensitive materials.
Although this unit represents an earlier-generation 5810R platform, these systems remain highly sought after due to their reliability, serviceability, and widespread use throughout research and clinical laboratories worldwide.
Browse additional used centrifuges for sale from American Instrument Exchange.
The Eppendorf 5810R is commonly used for blood and plasma separation, cell culture harvesting, microbiology workflows, biotechnology sample preparation, protein purification, molecular biology applications, pharmaceutical research, conical tube processing, environmental testing, and general laboratory centrifugation procedures. The refrigerated chamber helps preserve sample integrity during centrifugation, making the system particularly valuable for temperature-sensitive applications. The included A-4-62 rotor provides exceptional flexibility for laboratories processing a wide variety of sample formats.
Rotor compatibility is one of the most important considerations when purchasing a laboratory centrifuge. The Eppendorf 5810R is designed to support a variety of laboratory workflows depending on installed rotor configuration.
This particular system includes:
Depending on configuration, the Eppendorf 5810R may support:
The included A-4-62 rotor is designed for high-capacity sample processing and supports numerous adapter configurations, allowing laboratories to process a wide variety of sample types using a single rotor platform.
Customers should verify included rotors prior to purchase, as centrifuge configurations can vary between systems.
|
Specification |
Details |
|
Manufacturer |
Eppendorf |
|
Model |
5810R |
|
Centrifuge Type |
Refrigerated Benchtop Centrifuge |
|
Included Rotor |
A-4-62 Swinging Bucket Rotor |
|
Included Accessories |
Rotor Buckets |
|
Maximum Speed |
14,000 RPM |
|
Maximum RCF |
20,913 x g |
|
Maximum Capacity |
Up to 4 x 750 mL |
|
Refrigerated |
Yes |
|
Temperature Range |
Approx. -9°C to +40°C |
|
Electrical Requirements |
120V, 50/60Hz |
|
Installation Type |
Benchtop |
Specifications are provided to assist with planning and installation. Rotor compatibility, included accessories, and system configuration may vary depending on the specific unit available for sale.
The Eppendorf 5810R typically requires 120V, 50/60Hz electrical service and is designed for benchtop laboratory installation. Laboratories should verify electrical compatibility, available bench space, and ventilation requirements prior to purchasing this centrifuge.
The system contains refrigeration components and precision electronics that require careful packaging during transport. The centrifuge weighs substantially more than a standard microcentrifuge and typically ships via palletized freight carrier to protect sensitive refrigeration and drive components during shipment. Laboratories should verify installation space and delivery access requirements prior to shipment.
American Instrument Exchange can assist customers with freight coordination, shipping preparation, and installation planning for refrigerated laboratory centrifuges.
American Instrument Exchange specializes in refurbished laboratory centrifuges including refrigerated centrifuges, floor model centrifuges, benchtop centrifuges, blood banking centrifuges, and bioprocessing centrifuge systems.
Our technicians inspect and test centrifuges for:
If the centrifuge is sold with a rotor, we also test the rotor and centrifuge combination together to verify compatibility and operational performance.
Browse additional used centrifuges for sale, laboratory freezers and ultralow freezers, laboratory incubators, and biosafety cabinets from American Instrument Exchange.
American Instrument Exchange and AIE Laboratory Services provide centrifuge repair, preventive maintenance, diagnostics, and laboratory equipment service for many Eppendorf centrifuge models.
Available services may include:
In addition to centrifuges, we also service laboratory freezers and ultralow freezers, biosafety cabinets, incubators, laboratory refrigerators, cryostats, freeze dryers, and other laboratory equipment.
What rotor is included with this Eppendorf 5810R?
This system includes the Eppendorf A-4-62 swinging bucket rotor with buckets, making it suitable for blood tubes, conical tubes, bottles, and a wide range of laboratory sample formats.
Is this a refrigerated centrifuge?
Yes. The Eppendorf 5810R includes an integrated refrigeration system that helps maintain sample temperatures during centrifugation and is commonly used for temperature-sensitive biological samples.
Is this an older-generation Eppendorf 5810R?
Yes. This particular unit is an earlier-generation 5810R platform. Many laboratories continue to use these systems because of their reliability, durability, and straightforward serviceability.
What types of samples are commonly processed in the 5810R?
The 5810R is commonly used for blood processing, plasma separation, cell culture harvesting, protein purification, microbiology workflows, and biotechnology sample preparation.
What is the advantage of the A-4-62 rotor?
The A-4-62 rotor provides excellent flexibility by supporting numerous tube adapters and sample formats, allowing laboratories to process a wide range of vessels using a single rotor.
Are there any other rotors available with this unit? Do you sell Eppendorf rotors separately?
We generally try to pair centrifuges with rotors for sale. Occasionally we have rotors available separately, but we do not break up centrifuge and rotor combinations that have already been tested together. We recognize that rotors can be difficult to source and are often in demand. Please contact our sales team if you need assistance locating a specific Eppendorf rotor for your application.
My Eppendorf 5810R is displaying a refrigeration fault. Can you repair it?
Yes. AIE Laboratory Services repairs refrigeration systems, controllers, motors, lid-lock assemblies, and other components on many Eppendorf centrifuges. Both depot repair and field service options may be available depending on your location and the nature of the issue.
Can American Instrument Exchange service Eppendorf 5810R centrifuges?
Yes. AIE Laboratory Services provides repair, diagnostics, preventive maintenance, and support for many Eppendorf centrifuge systems, including the 5810R platform.
What is the A-4-62 rotor used for?
The A-4-62 swing-bucket rotor is designed for medium-speed centrifugation of larger tubes, bottles, and plates. It can accommodate vessels from 0.2 mL microtubes up to 250 mL bottles, making it ideal for cell culture work, blood tubes, and general laboratory processing. The Eppendorf 5810R and A-4-62 rotor combination is commonly used for:
What is the maximum speed and g-force with the A-4-62 rotor?
With the A-4-62 rotor installed, the Eppendorf 5810R can reach:
Higher speeds (up to 14,000 rpm) are achievable with other compatible fixed-angle rotors designed for smaller tubes. (Generally speaking, fixed angle rotors are designed for high speed applications while swinging bucket rotors are designed for higher capacity.) If you’d prefer to pair the Eppendorf 5810R with a different rotor please contact our sales team for pricing and availability of additional rotor options.
What temperature range does the refrigerated centrifuge support?
The refrigerated system allows precise temperature control from −9 °C to +40 °C, helping protect temperature-sensitive samples during centrifugation.
Refrigeration is necessary if you are going to use the Eppendorf 5810R centrifuge for protein purification, enzyme work, cell pelleting, and nucleic acid preparation.
How many programs can be stored?
The Eppendorf 5810R centrifuge can store up to 35 user-defined programs, allowing users to save frequently used protocols with specific speed, time, and temperature settings. So basically, you can access a programmed run with a few simple button pushes. This is a convenient feature that is a real time saver while simplifying routine workflows and ensures repeatability between runs.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.