Labconco Purifier 37300101
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Labconco Purifier 3730001 is a 3-foot Class I vented laboratory safety enclosure designed to provide personnel protection during procedures involving airborne biological contaminants, aerosols, and particulates. Available used and refurbished from American Instrument Exchange, this compact containment enclosure is suitable for laboratories requiring a dedicated work area for microbiological procedures, sample preparation, powder handling, and other applications where operator protection is important but product protection is not required.
Unlike a Class II biosafety cabinet, which provides both personnel and product protection through carefully controlled HEPA-filtered airflow, a Class I enclosure draws room air inward through the front opening and away from the operator. Contaminated air is directed toward the enclosure's exhaust filtration system, helping prevent potentially hazardous airborne particles from escaping into the surrounding laboratory.
This Labconco Purifier includes UV lighting and a compact 3-foot-wide configuration, making it a practical option for research laboratories, microbiology facilities, biotechnology companies, and other environments requiring localized containment without the footprint of a larger biosafety cabinet.
Used and refurbished Labconco Purifier Class I safety enclosure
Labconco catalog number 3730001
Compact 3-foot-wide laboratory containment workstation
Designed for personnel protection during appropriate biological and particulate-handling procedures
Inward airflow through the front access opening
Reverse-flow containment design
Exhaust filtration for airborne particulates, subject to installed filter configuration
UV light for supplemental work-area decontamination
Transparent front access for visibility during laboratory procedures
Suitable for installation in laboratories with limited workspace
Designed for applications that do not require product protection
Exhaust blower not included; installation requirements must be evaluated
Inspected and reconditioned by American Instrument Exchange
90-day warranty included
The Labconco Purifier 3730001 provides a specialized alternative to conventional chemical fume hoods and Class II biosafety cabinets for applications requiring personnel containment.
Its Class I airflow configuration draws room air through the front opening and across the work area, carrying airborne contaminants away from the operator and toward the exhaust system.
This arrangement is particularly useful for laboratory procedures that may generate biological aerosols, fine powders, or other airborne particles but do not require the work material itself to be protected from ambient laboratory air.
The enclosure's 3-foot width provides a relatively compact workstation for laboratory sample preparation and containment procedures. This can be especially advantageous when adding a dedicated containment area to an existing laboratory where floor or bench space is limited.
Class I safety enclosures are designed primarily to protect laboratory personnel and the surrounding environment from airborne contaminants generated during appropriate procedures.
During operation, room air enters through the front access opening, passes across the work area, and is directed toward the exhaust filtration system. This inward airflow helps reduce the likelihood that airborne particles generated inside the enclosure will escape toward the operator.
The Labconco Purifier uses a reverse-flow containment approach rather than the HEPA-filtered downward supply airflow associated with Class II biosafety cabinets.
Because room air enters the work area directly, the enclosure does not provide the same level of product protection as a Class II cabinet. It should therefore not be selected for procedures requiring a sterile work environment or protection of sensitive samples from ambient airborne contamination.
The Purifier Class I design uses exhaust filtration to help capture airborne particles before air is discharged from the enclosure. HEPA filtration is particularly valuable for procedures involving biological aerosols and fine particulates.
However, the filtration and exhaust configuration of this particular refurbished enclosure should be verified before installation. The condition of the installed filter, its suitability for the intended application, and the exhaust arrangement are important considerations when evaluating a used Class I safety enclosure.
American Instrument Exchange specifies that a blower motor is not included with this unit. Laboratories should therefore confirm the required blower, ductwork, and exhaust configuration before purchase.
HEPA filtration is intended for particulate containment and does not remove most chemical vapors or gases. Procedures involving volatile solvents, toxic gases, or significant chemical vapor generation generally require a different containment system.
This Labconco Purifier enclosure includes UV lighting intended to support supplemental decontamination of exposed work-area surfaces.
UV treatment may be incorporated into laboratory cleaning protocols between procedures, particularly when working with biological samples or other materials requiring careful contamination control.
However, UV exposure is affected by distance, exposure time, lamp condition, and shadowing from equipment or objects inside the enclosure. UV lighting should not be considered a substitute for appropriate chemical disinfection, cleaning, or validated decontamination procedures.
The UV system should be operated only according to applicable laboratory safety procedures, with personnel protected from direct ultraviolet exposure.
The Labconco Purifier 3730001 can support a range of laboratory procedures where personnel protection from airborne particulates or aerosols is required.
Potential applications include microbiological sample preparation, biological aerosol containment, environmental sample handling, powder weighing, powdered reagent transfer, media preparation, and selected research procedures involving materials that do not require product protection.
Its compact configuration can also make it useful as a dedicated containment workstation for repetitive procedures that would otherwise be performed on an open laboratory bench.
The suitability of the enclosure for any biological agent or hazardous material must be determined through a laboratory risk assessment and verification of the complete containment system.
The Purifier 3730001 is suitable for consideration in microbiology laboratories, biotechnology research facilities, pharmaceutical laboratories, environmental testing laboratories, university research departments, clinical research facilities, and industrial quality control laboratories.
Its smaller footprint makes it attractive for laboratories requiring an additional containment workstation without installing a larger cabinet.
Facilities performing a mixture of containment procedures should evaluate whether a Class I enclosure provides the required level of protection or whether a Class II biosafety cabinet would be more appropriate.
| Specification | Details |
|---|---|
| Manufacturer | Labconco |
| Product Line | Purifier |
| Catalog Number | 3730001 |
| AIE Product Code | 2919F HOOD |
| Product Type | Class I Vented Safety Enclosure |
| Nominal Width | 3 feet |
| Airflow Configuration | Inward airflow / reverse-flow containment |
| Primary Protection | Personnel |
| Product Protection | No |
| Exhaust Filtration | HEPA-based Class I design; verify installed filter |
| UV Lighting | Included |
| Exhaust Blower | Not included per AIE listing |
| External Exhaust | Verify required configuration before installation |
| Front Access | Transparent sash/access opening |
| Exterior Dimensions | Confirm for catalog 3730001 |
| Interior Dimensions | Confirm for catalog 3730001 |
| Electrical Requirements | Confirm from equipment nameplate |
| Weight | Confirm for catalog 3730001 |
| Condition | Used and reconditioned |
| Warranty | 90 days |
One of the most important considerations when selecting the Labconco Purifier 3730001 is understanding the difference between Class I and Class II containment.
A Class I enclosure provides personnel protection by drawing room air inward through the front opening and exhausting contaminated air through an appropriate filtration system.
A Class II biosafety cabinet provides personnel, product, and environmental protection through a combination of inward airflow, HEPA-filtered downward airflow, and HEPA-filtered exhaust.
For laboratories performing procedures that do not require protection of the sample from ambient contamination, a Class I enclosure may provide a more economical containment solution.
For aseptic cell culture, sterile manipulations, and other procedures where product protection is essential, an appropriately selected Class II biosafety cabinet is generally the better choice.
Although Class I safety enclosures and chemical fume hoods both use inward airflow to protect laboratory personnel, they are designed for different hazards.
The Labconco Purifier Class I enclosure is intended primarily for airborne biological contaminants and particulates. Its filtration system is designed to capture particles rather than chemical vapors.
A conventional chemical fume hood is generally intended for procedures involving hazardous chemical vapors, corrosive fumes, and volatile solvents.
Laboratories should choose the enclosure based on the material being handled and the type of hazard requiring containment rather than treating these systems as interchangeable.
Proper installation is essential to the performance of any Class I safety enclosure.
Because the blower is not included with this particular unit, the laboratory must determine the appropriate exhaust arrangement before placing the enclosure into service. This may involve selecting a compatible blower and coordinating the installation with laboratory facilities personnel or an experienced ventilation contractor.
Blower selection should account for the enclosure's required airflow, filter resistance, duct configuration, and other sources of static pressure.
After installation, the complete system should be evaluated to confirm that it provides the inward airflow and containment performance required for the intended procedures.
A Class I enclosure should not be placed into hazardous biological service based solely on its original manufacturer classification without verifying its current condition and installed performance.
This Labconco Purifier 3730001 is used and reconditioned by American Instrument Exchange.
Our technicians inspect the enclosure's structural condition, airflow components, baffles, lighting, and access opening to identify damage or operating issues. The enclosure is cleaned and prepared for shipment following the applicable inspection and refurbishment process.
Because the exhaust blower is not included, final airflow performance must be established after the unit is connected to the appropriate ventilation system.
The installed filter condition, UV lamp operation, and any required containment certification should also be evaluated before the enclosure is used for hazardous procedures.
Purchasing a refurbished Class I laboratory enclosure can provide a cost-effective way to add dedicated containment capacity to an existing laboratory.
American Instrument Exchange supplies a broad selection of refurbished laboratory ventilation and containment equipment, including Class I enclosures, biosafety cabinets, clean benches, and chemical fume hoods.
In addition to equipment sales, AIE Laboratory Services provides biosafety cabinet certification, airflow testing, equipment repairs, and other laboratory service support for customers throughout New England.
This Labconco Purifier 3730001 includes a 90-day warranty from American Instrument Exchange.
The Labconco Purifier 3730001 is a Class I vented safety enclosure intended to provide personnel protection during appropriate laboratory procedures involving airborne biological contaminants, aerosols, and particulates.
No. A Class I enclosure draws room air directly into the work area and therefore does not provide the HEPA-filtered supply air required for product protection. Laboratories performing sterile or aseptic procedures should consider an appropriate Class II biosafety cabinet.
No. American Instrument Exchange specifies that a blower motor is not included. The required ventilation system must be determined and installed before the enclosure is placed into service.
Yes. The AIE-listed enclosure includes UV lighting that may be used as part of an appropriate laboratory surface-decontamination protocol.
Potentially, yes. Class I enclosures are used for selected microbiological procedures where personnel protection is required but product protection is not. The suitability of this particular enclosure depends on the biological agents involved, the procedures performed, and verification of the complete containment system.
It should not be assumed suitable for chemical vapor containment. HEPA filtration captures particles but does not remove most chemical vapors or gases. Laboratories handling volatile chemicals should evaluate an appropriate chemical fume hood instead.
The complete enclosure and exhaust system should undergo appropriate airflow and containment verification before use. Additional certification requirements depend on the intended application, applicable standards, and the laboratory's safety program.
Both belong to Labconco's Purifier Class I containment family, but their equipment configurations and exhaust arrangements may differ. The 3730001 offered by American Instrument Exchange is an older vented enclosure without an included blower. Buyers should not assume that specifications or accessories published for newer 3980301 models apply directly to this unit.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.