Labconco XPert 3950402 4' Filtered Balance System

Fully Tested & Warrantied*
Product Code : SKU 2864CC HOOD
Date In: 6/3/2025

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Labconco XPert 3950402 4' Filtered Balance System with Guardian 1000 Digital Airflow Monitor – Used and Refurbished

The Labconco XPert 3950402 Filtered Balance System is a 4-foot powder containment enclosure designed to protect laboratory personnel during weighing, transfer, and manipulation of powders and particulates. Combining a spacious balance-compatible work area with an integral blower, 99.99% efficient exhaust HEPA filter, and Guardian 1000 Digital Airflow Monitor, the XPert provides a self-contained solution for pharmaceutical powder weighing, analytical sample preparation, dry chemical handling, and other particulate-generating laboratory procedures.

Unlike an XPert Balance Enclosure that requires connection to a separate exhaust system, the Labconco 3950402 incorporates its blower and HEPA filtration system directly into the upper plenum. Contaminated air is drawn away from the operator, passed through the HEPA filter, and returned to the laboratory as filtered exhaust for appropriate particulate applications. This eliminates the need for external ductwork or a separate filtered exhauster during normal recirculating operation.

The 3950402 also incorporates Labconco's Guardian 1000 Digital Airflow Monitor. The monitor continuously measures airflow and displays actual face velocity while providing audible and visual warnings if airflow moves outside the established operating range. This gives laboratory personnel immediate feedback on one of the most important operating parameters of a powder containment enclosure.

With an overall width of 48 inches and an interior approximately 45.6 inches wide × 23.4 inches deep × 22.7 inches high, the XPert 3950402 provides enough room for many analytical balances, microbalances, precision balances, and supporting sample-preparation equipment. Labconco's aerodynamic Clean-Sweep airfoil, upper containment sash foil, upper dilution air supply, side-entry airfoils, and zone-perforated rear baffle help provide effective containment while limiting airflow disturbances around sensitive weighing instruments.

This Labconco XPert 3950402 is used and refurbished by American Instrument Exchange. AIE technicians inspect and test the system before shipment, including blower operation, airflow, Guardian 1000 monitor, lighting, controls, sash operation, and other installed functions. The enclosure is thoroughly cleaned and includes a 90-day warranty.

Key Features

  • Labconco catalog number 3950402

  • 4-foot XPert Filtered Balance System

  • Guardian 1000 Digital Airflow Monitor

  • Digital face-velocity display with audible and visual airflow alarm

  • Built-in blower and exhaust HEPA filter

  • HEPA filtration rated 99.99% efficient for 0.3-micron particles

  • No outside ducting required for normal recirculating operation

  • True bag-in/bag-out HEPA filter disposal system

  • Vibration-isolated motorized impeller

  • 23.4-inch-deep balance-compatible interior

  • Clean-Sweep airfoil and zone-perforated rear baffle

  • Upper dilution air supply and upper containment sash foil

  • 9.4-inch sash opening

  • 115 V electrical configuration

  • Used and refurbished by American Instrument Exchange

  • 90-day warranty included

Overview

The Labconco XPert Filtered Balance System was developed around a problem commonly encountered in pharmaceutical, biotechnology, chemical, and analytical laboratories: safely containing powders while maintaining an environment suitable for accurate weighing.

Powders can become airborne when containers are opened, material is scooped or transferred, samples are weighed, or residue is cleaned from laboratory surfaces. When the material is potent, toxic, irritating, or otherwise hazardous, even relatively small weighing procedures can create an occupational exposure concern.

A conventional chemical fume hood can provide containment, but its higher airflow and larger sash opening may create conditions that interfere with sensitive balance measurements.

The XPert takes a different approach.

The enclosure combines controlled inward airflow with a relatively small sash opening and aerodynamic airflow-management features specifically designed around laboratory weighing.

The 3950402 adds a built-in blower, exhaust HEPA filtration, and digital airflow monitoring, creating a complete powder-containment workstation without requiring a separate filtered exhauster.

Common Applications

The Labconco XPert 3950402 is well suited to pharmaceutical powder weighing, active pharmaceutical ingredient handling, dry chemical transfer, toxic-powder containment, analytical sample preparation, formulation research, quality-control testing, environmental sample weighing, gravimetric procedures, fine-chemical handling, research-compound preparation, mold and asbestos sample weighing, and other laboratory procedures involving appropriately filterable particulates.

Its 4-foot width also provides sufficient working space for procedures that require a balance plus sample containers, weighing vessels, transfer tools, or other small laboratory equipment.

The XPert is primarily a particulate containment system. Applications generating hazardous gases or significant chemical vapors require additional application assessment and an appropriate containment or exhaust strategy.

Ideal Laboratory Types

The XPert 3950402 is particularly well suited to pharmaceutical research and development laboratories, biotechnology companies, analytical laboratories, chemical laboratories, environmental testing facilities, industrial quality-control laboratories, formulation laboratories, contract research organizations, forensic laboratories, academic research facilities, and other laboratories routinely working with powdered materials.

Its combination of containment, digital airflow monitoring, and a large 4-foot work area also makes it attractive for laboratories establishing dedicated powder-weighing stations.

Key Specifications

Specification Details
Manufacturer Labconco
Product Family XPert
Catalog Number 3950402
Equipment Type Filtered Balance System / Powder Containment Enclosure
Nominal Width 4 ft
Overall Dimensions 48"W × 29"D × 37.1"H
Interior Dimensions Approx. 45.6"W × 23.4"D × 22.7"H
Sash Opening Height Approx. 9.4"
Sash Opening Width Approx. 45.6"
Airflow Monitor Guardian 1000 Digital
Airflow Display Digital Face-Velocity Readout
Airflow Alarm Audible / Visual
Blower Built-In, Vibration-Isolated Motorized Impeller
Filtration Exhaust HEPA
HEPA Efficiency 99.99% at 0.3 Micron
Filter Disposal True Bag-In / Bag-Out
Outside Ducting Required No, for Normal Recirculating Operation
Lighting Fluorescent
Sash Tempered Safety Glass
Interior Depth Approx. 23.4"
Electrical 100–115 V, 60 Hz
Work Surface Separate / Verify Included Components
Supporting Base Separate / Verify Included Components
Approximate Weight 280 lb
Condition Used / Refurbished
Warranty 90 Days from American Instrument Exchange

Guardian 1000 Digital Airflow Monitor

The Guardian 1000 Digital Airflow Monitor is one of the most important features distinguishing catalog number 3950402 from other XPert configurations.

Rather than providing only a simple status indicator, the Guardian 1000 continuously monitors airflow and provides a digital readout of actual face velocity.

If airflow moves outside the established set-point range, the system alerts the operator with audible and visual alarms.

This gives laboratory personnel immediate information about containment conditions before and during a weighing procedure.

For facilities with documentation or monitoring requirements, the Guardian 1000 also provides an RS-232 communications capability for connection to a user-supplied computer.

Powder and Particulate Containment

The primary purpose of the XPert 3950402 is personnel protection during procedures that can release airborne powders or particulates.

The built-in blower draws room air inward through the sash opening.

This inward airflow helps create a barrier between material inside the enclosure and the operator's breathing zone.

Particles released during weighing or transfer are carried toward the rear baffle and through the exhaust HEPA filtration system.

For appropriate particulate applications, the HEPA-filtered air can then be returned directly to the laboratory.

Built-In 99.99% HEPA Filtration

The XPert 3950402 incorporates an exhaust HEPA filter rated 99.99% efficient for particles 0.3 micron in size.

HEPA filtration makes the system particularly useful for dry powders and other particulate contaminants.

Because the filtration system is incorporated into the enclosure, laboratories do not need to purchase and install a separate HEPA exhauster for normal operation.

HEPA filtration captures particles rather than chemical gases and vapors. Procedures involving volatile chemicals require a containment system appropriate for those contaminants.

Built-In Blower

A motorized impeller is incorporated into the XPert's upper plenum.

This allows the enclosure to generate its own containment airflow without connection to a separate remote blower.

Integrating the blower directly into the system simplifies installation and makes the XPert a relatively self-contained laboratory workstation.

The blower is dynamically balanced and mounted on vibration-isolation supports to minimize disturbance to sensitive balances positioned within the enclosure.

Vibration Isolation for Sensitive Weighing

Balance performance can be affected by vibration as well as airflow.

This is especially important for analytical and microbalances capable of resolving very small changes in mass.

Labconco mounts the XPert's motorized impeller on isolation supports to reduce transmission of blower vibration into the work area.

This design helps make the system better suited to sensitive weighing procedures than a generic enclosure with a conventional blower mounted directly to its structure.

Deep 23.4-Inch Interior

The XPert 3950402 provides an interior depth of approximately 23.4 inches.

This gives laboratories enough space to accommodate many large analytical, precision, and microbalances while maintaining room for weighing vessels, sample containers, spatulas, weigh boats, and related accessories.

The 4-foot model also provides approximately 45.6 inches of interior width, making it substantially more spacious than the 2-foot XPert configurations.

Four-Foot Working Width

The 4-foot configuration is particularly useful when the laboratory needs more than a compact single-balance station.

Its larger work area can accommodate a substantial analytical balance along with sample containers and preparation accessories.

The additional width can also improve workflow when repeated weighing procedures require several containers, reference materials, or supporting tools to remain inside the enclosure.

Equipment should still be arranged so the front airfoil and rear baffle remain unobstructed.

9.4-Inch Sash Opening

The XPert 3950402 uses an approximately 9.4-inch-high working sash opening.

Keeping the opening relatively small reduces the amount of air that must be moved to establish the required inward airflow.

Lower airflow demand is particularly beneficial for weighing applications because excessive air movement can interfere with balance stability.

The hinged sash can also be raised when additional access is required for equipment loading.

Clean-Sweep Airfoil

Labconco's Clean-Sweep airfoil helps guide room air smoothly into the enclosure and across the work surface.

Smooth airflow at the front opening reduces turbulence while helping maintain containment.

This is particularly important around a sensitive balance, where unnecessary air disturbances can increase settling time or produce unstable measurements.

The front airfoil should remain free of containers, paperwork, equipment, and other obstructions during use.

Upper Containment Sash Foil

The upper containment sash foil helps direct airflow into the enclosure near the upper portion of the front opening.

This helps move contaminants away from the operator's breathing zone and toward the enclosure's filtration system.

Together with the front airfoil and rear baffle, the sash foil forms part of the XPert's integrated aerodynamic containment design.

Upper Dilution Air Supply

The upper dilution air supply introduces room air near the top of the sash.

This helps dilute contaminants in the upper region of the enclosure while bathing the rear surface of the sash with clean air.

The result is improved airflow management across an area that can otherwise become susceptible to stagnant zones.

Zone-Perforated Rear Baffle

A perforated rear baffle helps distribute airflow across the work area.

Instead of concentrating exhaust airflow at one small point, the baffle encourages relatively uniform movement toward the rear of the enclosure.

This promotes particulate capture while helping reduce areas of excessive air velocity around the balance.

The baffle pivots for easier cleaning.

Side-Entry Airfoils

Side-entry airfoils allow room air to sweep across the interior glass surfaces.

This helps improve containment around the sides of the enclosure and reduces stagnant regions adjacent to the glass.

The side-entry design works with the other aerodynamic features to maintain containment without relying solely on high exhaust velocity.

Tempered Safety Glass

The XPert uses 1/4-inch-thick tempered safety glass for the front sash and side panels.

Tempered glass provides good scratch, fire, and chemical resistance while maintaining excellent visibility into the work area.

Glass also dissipates static charge more effectively than many plastic enclosure materials.

Static control can be especially relevant when manipulating fine powders that may otherwise adhere to surfaces or interfere with weighing procedures.

Ergonomic Angled Sash

The XPert incorporates an approximately 10-degree angled front sash.

This improves the operator's view of the balance and sample while allowing a more comfortable working posture.

The sash is hinged and can pivot upward and lock for loading equipment into the enclosure.

A wiping seal helps maintain containment around the sash.

Intrinsically Safe Negative-Pressure Design

The XPert's blower and filtration arrangement is designed so that the positive-pressure impeller is surrounded by a negative-pressure plenum.

If leakage were to occur around the positive-pressure portion of the system, unfiltered air would be captured by the surrounding negative-pressure area and directed back through filtration.

This design provides an additional level of containment within the enclosure's exhaust system.

Bag-In/Bag-Out HEPA Filter Disposal

The XPert incorporates a true bag-in/bag-out system for HEPA filter removal.

This feature is particularly valuable when the filter has accumulated potent or hazardous powders.

The filter can be contained during removal rather than openly handled after it has collected contaminants.

Filter replacement involving hazardous materials should be performed using appropriate procedures and by personnel qualified for the application.

Pharmaceutical Powder Weighing

Pharmaceutical laboratories are one of the principal environments for XPert Filtered Balance Systems.

Opening containers, scooping powders, transferring active compounds, and weighing samples can all release fine airborne particles.

The XPert creates localized containment around these procedures while maintaining conditions intended to remain compatible with precision weighing.

Its 4-foot width can be especially useful in formulation, analytical development, and quality-control laboratories that require additional working space around the balance.

Active Pharmaceutical Ingredient Handling

Potent active pharmaceutical ingredients may require strict control of occupational exposure.

The XPert 3950402 can form part of a containment strategy for appropriate API weighing and transfer procedures.

Suitability should be determined through a compound-specific risk assessment that considers potency, occupational exposure limits, quantity handled, particle characteristics, frequency of use, and the facility's required containment level.

The Guardian 1000 provides an additional operational safeguard by continuously displaying face velocity and warning personnel if airflow falls outside the intended range.

Analytical Balance Applications

The XPert is specifically designed to accommodate analytical balances.

Its deep interior provides sufficient space for many balance platforms while leaving room for sample transfer and preparation.

Controlled airflow, aerodynamic containment features, and vibration isolation help reduce conditions that could negatively affect balance readings.

The laboratory should still verify measurement stability under actual operating conditions, particularly for high-resolution analytical work.

Microbalance Applications

The interior can also accommodate many microbalances.

Microbalances are especially sensitive to vibration, air movement, static electricity, temperature gradients, and operator technique.

Labconco's low-disturbance airflow design and vibration-isolated blower help address several of these concerns.

For extremely high-resolution weighing, laboratories should validate balance performance within the enclosure before establishing routine analytical procedures.

Precision Balance Applications

Precision balances are another natural fit for the XPert 3950402.

These instruments generally tolerate airflow more readily than microbalances while still benefiting from localized powder containment.

The large 4-foot interior allows the laboratory to establish a complete weighing station with room for samples, containers, and transfer tools.

Dry Chemical Handling

Chemical and industrial laboratories can use the XPert for compatible dry chemical weighing and transfer.

Powdered reagents, pigments, catalysts, standards, and fine chemicals may become airborne during normal handling.

Capturing these particles at the point of use helps reduce contamination of surrounding laboratory surfaces and personnel exposure.

Materials that release hazardous vapors require additional evaluation because HEPA filtration alone does not remove gases.

Mold and Asbestos Weighing

Labconco identifies mold and asbestos weighing among the particulate applications appropriate for XPert Filtered Balance Systems.

These materials can generate fine airborne particles that should be contained during sample preparation and weighing.

The enclosure's HEPA filtration and inward airflow provide a localized containment strategy for suitable laboratory procedures.

Facility-specific safety protocols should still govern handling, decontamination, and waste disposal.

Environmental Laboratory Applications

Environmental laboratories frequently weigh filters, soils, sediments, dust, dried residues, and other particulate samples.

Handling these materials can release dust into the surrounding laboratory.

The XPert provides a dedicated area for gravimetric and sample-preparation procedures while helping protect personnel and limit contamination of the laboratory environment.

Quality-Control Applications

Quality-control laboratories may perform hundreds of repetitive weighing procedures using powdered raw materials, intermediates, or finished products.

A dedicated filtered balance system provides a consistent containment environment for these operations.

The Guardian 1000 Digital Airflow Monitor also allows operators to verify face velocity before or during each procedure.

XPert 3950402 vs. XPert 3950400

Catalog numbers within the XPert family identify important configuration differences.

The 3950402 is the 4-foot, 115 V Filtered Balance System equipped with the Guardian 1000 Digital Airflow Monitor.

Versions without a built-in airflow monitor or with a different Guardian monitor should not be assumed to have the same monitoring capabilities.

Including the exact catalog number when purchasing used XPert equipment helps ensure the laboratory receives the intended configuration.

XPert Filtered Balance System vs. XPert Balance Enclosure

The difference between these two Labconco product families is important.

The XPert 3950402 Filtered Balance System includes its own blower and exhaust HEPA filter.

An XPert Balance Enclosure, such as models in the 3930 series, requires an external exhaust source such as building exhaust, a remote blower, or a compatible FilterMate.

The 3950402 is therefore a more self-contained solution for particulate weighing applications.

XPert vs. Conventional Chemical Fume Hood

A conventional chemical fume hood is primarily designed to contain chemical gases and vapors and usually exhausts air outside the building.

The XPert 3950402 is optimized for powder and particulate containment.

Its lower-disturbance airflow, smaller sash opening, deep balance-compatible interior, and vibration-isolated blower make it particularly well suited to weighing procedures.

When hazardous gases or substantial chemical vapors are generated, an appropriate chemical fume hood or other containment system may be required.

XPert vs. Biosafety Cabinet

The XPert 3950402 is not a Class II biological safety cabinet.

A biosafety cabinet uses specifically engineered HEPA-filtered airflow patterns for biological containment and, in Class II systems, also provides product protection.

The XPert is primarily designed to protect personnel during weighing and handling of powders and particulates.

Laboratories should select containment equipment according to the actual biological, chemical, or particulate hazard involved.

Recirculating HEPA-Filtered Operation

For appropriate particulate applications, the XPert returns HEPA-filtered exhaust air to the laboratory.

This eliminates the need to install external ductwork and avoids continuously exhausting conditioned laboratory air outdoors.

Installation can therefore be significantly simpler than adding a hard-ducted containment hood.

Recirculation should only be used when HEPA filtration is appropriate for all contaminants generated by the procedure.

Optional Outside Exhaust

XPert Filtered Balance Systems can also be configured for outside exhaust using appropriate accessories.

This may be useful when facility policies require external discharge or when the application benefits from exhausting filtered air outside rather than returning it to the room.

Any external exhaust configuration should be designed and balanced according to Labconco recommendations and facility requirements.

Work Surface and Supporting Base

The XPert 3950402 requires an appropriate work surface and supporting base.

Labconco offers compatible dished epoxy and other work-surface configurations along with supporting cabinets and stands.

A stable, level surface is particularly important when an analytical or microbalance is installed.

Because used equipment configurations vary, customers should confirm exactly which work surface, stand, cabinet, and accessories are included with this American Instrument Exchange unit.

HEPA Filter Maintenance

HEPA filter life depends on the type and quantity of particulate material handled, operating hours, loading rate, and laboratory procedures.

As filters load, airflow resistance increases.

The blower speed control and airflow-monitoring system help laboratories maintain appropriate operating conditions, but HEPA filters eventually require replacement.

Filters exposed to hazardous materials should be treated as contaminated components and replaced using appropriate containment procedures.

Proper Equipment Placement

Balances should be positioned sufficiently inside the enclosure while maintaining clearance from the rear baffle.

Containers and instruments should not block the Clean-Sweep airfoil at the front of the enclosure.

Avoiding unnecessary clutter helps preserve the designed airflow pattern and makes routine cleaning easier.

The 4-foot model provides substantial working room, but the additional space should not be treated as storage during hazardous procedures.

Refurbishment and Testing by American Instrument Exchange

American Instrument Exchange inspects and tests used filtered balance systems before shipment.

For the Labconco XPert 3950402, AIE technicians evaluate the built-in blower, airflow, Guardian 1000 Digital Airflow Monitor, controls, lighting, sash operation, HEPA filter housing, and other installed components.

Glass, baffles, airfoils, interior surfaces, and exterior components are inspected for condition, and accessible surfaces are thoroughly cleaned before shipment.

Customers should confirm the HEPA filter condition and any work surface, base, or accessories included with the individual unit before purchase.

Why Buy a Refurbished Labconco XPert 3950402?

The Labconco XPert 3950402 combines powder containment, sensitive balance compatibility, built-in HEPA filtration, integrated exhaust, and digital airflow monitoring in one laboratory system.

Its 4-foot workspace provides considerably more room than smaller balance enclosures, while the Guardian 1000 allows personnel to continuously verify face velocity.

For pharmaceutical, biotechnology, analytical, environmental, chemical, and quality-control laboratories, purchasing a used and refurbished XPert can provide a cost-effective way to establish a dedicated powder-weighing workstation without the expense and installation requirements associated with a new system.

American Instrument Exchange inspects, tests, and cleans the system before shipment and includes a 90-day warranty.

Shipping and Installation

The Labconco XPert 3950402 measures approximately 48 inches wide × 29 inches deep × 37.1 inches high and weighs approximately 280 pounds before the addition of a work surface, base, balance, or accessories.

The unit operates on 100–115 V, 60 Hz electrical service.

An appropriate stable work surface and supporting base are required.

Because outside ducting is not necessary for normal HEPA-filtered recirculating operation, installation can be considerably simpler than a conventional externally exhausted hood.

After installation, airflow and monitor operation should be evaluated before hazardous powders are routinely handled.

Related Equipment

Laboratories using the Labconco XPert 3950402 may also require analytical balances, precision balances, microbalances, powder-handling equipment, chemical fume hoods, ductless filtered enclosures, biosafety cabinets, laboratory refrigerators and freezers, centrifuges, water baths, shakers, incubators, and other equipment used for analytical sample preparation.

American Instrument Exchange supplies used and refurbished laboratory containment systems, analytical balances, fume hoods, biosafety cabinets, clean benches, and other laboratory equipment for pharmaceutical, biotechnology, chemical, environmental, industrial, academic, and research laboratories.

Labconco XPert 3950402 Filtered Balance System FAQs

What is the Labconco XPert 3950402?

The Labconco 3950402 is a 4-foot XPert Filtered Balance System designed to protect personnel during laboratory weighing and handling of powders and particulates.

Does the Labconco 3950402 include a blower?

Yes. The 3950402 incorporates a built-in motorized impeller, so a separate blower is not required for normal recirculating operation.

Does the XPert 3950402 include HEPA filtration?

Yes. It incorporates an exhaust HEPA filter rated 99.99% efficient for particles 0.3 micron in size.

What airflow monitor does catalog number 3950402 use?

The 3950402 is equipped with the Guardian 1000 Digital Airflow Monitor.

What does the Guardian 1000 display?

It continuously monitors airflow and provides a digital readout of actual face velocity.

Does the Guardian 1000 have an alarm?

Yes. Audible and visual alarms alert the operator when airflow moves outside the established set-point range.

Does the Labconco 3950402 require outside ductwork?

No. For appropriate particulate applications, HEPA-filtered exhaust is returned to the laboratory, so normal operation does not require outside ducting.

How wide is the XPert 3950402?

It is a nominal 4-foot system with an overall width of 48 inches.

What are the overall dimensions?

The system measures approximately 48"W × 29"D × 37.1"H.

What are the interior dimensions?

The work area is approximately 45.6"W × 23.4"D × 22.7"H.

What is the sash opening height?

The standard working sash opening is approximately 9.4 inches high.

Can it accommodate an analytical balance?

Yes. The XPert was specifically designed to accommodate large analytical and microbalances.

Can it be used with a microbalance?

Yes, although laboratories performing very high-resolution measurements should verify weighing stability under actual operating conditions.

Can it be used with a precision balance?

Yes. Precision balances are well suited to many XPert powder-weighing applications.

Is the XPert 3950402 appropriate for pharmaceutical powders?

Yes. Pharmaceutical powder weighing is one of the primary applications for XPert Filtered Balance Systems.

Can it be used for active pharmaceutical ingredients?

It may be appropriate for compatible API weighing and transfer applications when the required containment level falls within the capabilities of the system and the facility's risk assessment.

Can it be used for dry chemicals?

Yes. The XPert can contain appropriately filterable dry chemical powders and particulates.

Does the HEPA filter remove chemical vapors?

No. HEPA filters capture particles and should not be relied upon to remove hazardous gases or vapors.

Can the XPert 3950402 be externally exhausted?

Yes. Appropriate canopy and exhaust accessories can be used when filtered exhaust needs to be discharged outside the building.

What is the bag-in/bag-out filter system?

The design allows a contaminated HEPA filter to be contained during removal, reducing direct exposure to material collected by the filter.

Why is vibration isolation important?

Sensitive analytical and microbalances can be affected by mechanical vibration. The XPert's motorized impeller is mounted on isolation supports to minimize vibration transmitted to the weighing area.

What is the Clean-Sweep airfoil?

The Clean-Sweep airfoil helps room air enter smoothly across the front of the enclosure, improving containment while reducing disruptive turbulence.

Is the XPert 3950402 a chemical fume hood?

No. It is primarily a powder and particulate containment system optimized for laboratory weighing.

Is it a biosafety cabinet?

No. The XPert is not a Class II biosafety cabinet and should not replace appropriate biological containment equipment.

Are the work surface and base included?

Labconco specifies the work surface and supporting base as separate required accessories. Customers should verify exactly what is included with this individual AIE unit.

What electrical service does the 3950402 require?

This configuration is designed for 100–115 V, 60 Hz operation.

How much does the XPert 3950402 weigh?

Labconco specifies the enclosure at approximately 280 pounds.

Is this Labconco XPert 3950402 refurbished?

Yes. This unit is used and refurbished by American Instrument Exchange.

How does AIE test the XPert?

AIE technicians inspect and test the blower, airflow, Guardian 1000 Digital Airflow Monitor, lighting, controls, sash operation, filtration housing, and other installed functions before shipment.

Does the refurbished Labconco XPert include a warranty?

Yes. American Instrument Exchange includes a 90-day warranty with this refurbished XPert Filtered Balance System.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.