Misonix Aura 250L Ductless Fume Hood
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Misonix Aura 250L is a compact ductless laboratory fume hood designed to provide personnel protection during selected chemical handling procedures involving hazardous fumes, vapors, and odors. Available used and refurbished from American Instrument Exchange, this specialized chemical filtration enclosure combines an integrated blower, electronically controlled airflow, and advanced filter monitoring to provide a practical alternative to conventional ducted chemical fume hoods.
Unlike traditional laboratory fume hoods that exhaust contaminated air outside the building, the Misonix Aura 250L uses application-specific filtration to capture compatible chemical contaminants before returning treated air to the laboratory. This recirculating design can simplify installation and reduce the need for expensive building ventilation modifications.
The Aura 250L offered by American Instrument Exchange measures approximately 30" W × 28" D × 48" H and is listed with an airflow capacity of 135 CFM at 125 linear feet per minute. Its compact footprint makes it particularly attractive for analytical chemistry laboratories, pharmaceutical research facilities, educational laboratories, and other environments requiring localized chemical vapor containment.
Used and refurbished Misonix Aura 250L ductless fume hood
Compact 30-inch-wide laboratory enclosure
Integrated blower motor included
Ductless, recirculating filtration design
Electronic airflow monitoring and automatic blower adjustment
Digital airflow display
Audible and visual low-airflow alarms
Hydrocarbon vapor breakthrough monitoring
Filter saturation monitoring and replacement alerts
Automatic blower-speed adjustment based on sash position
Filtrak filter-locking system
Electrostatically charged particulate prefilter
Chemically resistant transparent acrylic panels
Powder-coated aluminum construction
Fluorescent work area lighting
Removable fiberglass spill tray
No external exhaust ductwork required for approved applications
Used and reconditioned by American Instrument Exchange
90-day warranty included
The Misonix Aura 250L belongs to the Aura family of ductless laboratory fume hoods, developed to provide chemical vapor containment through controlled airflow and specialized filtration.
Its compact design is intended for laboratory procedures involving relatively small quantities of compatible chemicals, particularly where conventional ducted ventilation is unavailable or difficult to install.
During operation, the integrated blower draws room air inward through the front access opening. Air containing chemical vapors or airborne contaminants is directed through the enclosure's filtration system before being returned to the surrounding laboratory.
The Aura 250L incorporates electronic monitoring features intended to help operators identify conditions that could compromise safe operation, including insufficient airflow and potential filter breakthrough.
Because ductless containment depends on the selected filtration media, the hood must be matched to the specific chemicals and procedures used in the laboratory.
The defining feature of the Misonix Aura 250L is its ductless filtration system.
Rather than relying on external ductwork to remove chemical vapors from the building, the enclosure uses specialized filters to capture compatible contaminants from the exhaust stream.
Misonix Aura systems support activated carbon filtration for selected chemical vapors, including filter media formulated for different chemical classes. HEPA filtration options are also available for particulate applications.
The correct filter must be selected according to the chemicals handled, expected vapor concentrations, quantities used, operating duration, and manufacturer compatibility guidance.
A standard activated carbon filter should not be assumed effective against every solvent, acid, base, or hazardous gas. Some substances may require specially treated carbon, another filtration technology, or a conventional externally exhausted chemical fume hood.
The exact main and safety filters installed in this refurbished Aura 250L should be confirmed before use. The inclusion of an electrostatic prefilter does not establish that a suitable chemical vapor filter is installed.
The Misonix Aura 250L includes an integrated blower motor that generates the inward airflow necessary for chemical containment.
Unlike conventional ducted laboratory fume hoods, this system does not require a separate rooftop or inline exhaust blower for approved ductless applications.
The Aura's electronic control system monitors operating conditions and adjusts blower performance to help maintain appropriate airflow.
Automatic blower adjustment is particularly useful as the sash position changes or filtration resistance increases during normal operation.
The digital airflow display provides operators with information about system performance, while audible and visual alarms warn of low-airflow conditions.
These features help distinguish the Aura 250L from simpler ductless enclosures that offer limited operating feedback.
One of the most important features of the Aura 250L is its electronic filtration monitoring system.
Misonix Aura enclosures incorporate hydrocarbon vapor sensing intended to detect certain organic vapor breakthrough conditions. The system also provides filter saturation information and alerts to support maintenance decisions.
This monitoring can help operators identify when a filter may no longer be providing the intended protection for compatible monitored vapors.
However, a hydrocarbon sensor cannot be assumed to detect every hazardous chemical. Filter breakthrough may occur with substances that are not adequately detected by the installed sensor.
Laboratories should therefore use manufacturer-recommended filter selection, replacement schedules, and chemical-specific risk assessments rather than relying exclusively on electronic alarms.
The Aura filtration system incorporates Misonix's Filtrak filter-locking design.
This system is intended to provide a secure seal around the installed filter, reducing the possibility that contaminated air will bypass the filtration media.
An alarm can alert the operator when the filter-locking mechanism is not properly engaged.
Effective filtration depends on both the suitability of the filter media and the integrity of the filter installation. A poorly seated filter can compromise performance even when the filtration material itself is appropriate for the application.
The Filtrak system provides an additional safeguard by helping identify improper filter installation before or during operation.
The Misonix Aura 250L combines transparent acrylic enclosure panels with powder-coated aluminum structural components.
The transparent panels provide visibility during chemical handling procedures, allowing operators to observe samples, glassware, and instruments without unnecessarily opening the enclosure.
Fluorescent work area lighting improves visibility during sample preparation and routine laboratory procedures.
The Aura family also incorporates a removable fiberglass spill tray designed to help contain incidental spills and facilitate cleaning.
These construction features make the enclosure suitable for consideration in laboratories requiring a compact, enclosed chemical-handling workstation.
Material compatibility should be evaluated for the specific chemicals used, particularly when handling solvents or reagents that may damage acrylic or other enclosure components.
The Misonix Aura 250L can support a variety of laboratory procedures involving small quantities of compatible chemicals.
Potential applications include analytical sample preparation, reagent dispensing, chemical weighing, solvent handling, chromatography sample preparation, pharmaceutical research, environmental testing, and selected educational chemistry procedures.
The enclosure may also be useful for laboratories performing repetitive operations that generate chemical odors or vapors and would otherwise require a dedicated ducted workstation.
Its suitability depends on the chemicals involved, the quantities handled, and the installed filtration system. Applications involving highly toxic substances, large solvent volumes, uncontrolled chemical reactions, or incompatible gases may require an externally exhausted chemical fume hood.
The Aura 250L is particularly attractive for analytical chemistry laboratories, pharmaceutical research and development facilities, biotechnology laboratories, environmental testing laboratories, industrial quality control departments, and university teaching laboratories.
Its small footprint and ductless configuration may also benefit facilities operating in leased laboratory spaces where installing new exhaust ductwork would be difficult or expensive.
Laboratories with intermittent chemical-handling requirements may find a properly configured ductless enclosure useful when the intended procedures fall within the filtration system's approved operating limits.
| Specification | Details |
|---|---|
| Manufacturer | Misonix |
| Product Line | Aura |
| Model | Aura 250L |
| AIE Product Code | 2912E HOOD |
| Product Type | Ductless Chemical Fume Hood |
| Nominal Width | 30 inches |
| Exterior Dimensions Listed by AIE | 30" W × 28" D × 48" H |
| Airflow Listed by AIE | 135 CFM |
| Face Velocity Listed by AIE | 125 LFPM |
| Ventilation Configuration | Ductless, recirculating |
| Blower Motor | Integrated |
| Airflow Control | Automatic electronic blower adjustment |
| Airflow Display | Digital |
| Low-Airflow Alarm | Audible and visual |
| Chemical Monitoring | Hydrocarbon breakthrough sensor |
| Filter Monitoring | Filter saturation indication and alarms |
| Filter Retention | Filtrak locking system |
| Prefilter | Electrostatically charged |
| Main Filtration | Application-specific; verify installed filter |
| Safety Filtration | Verify installed configuration |
| Exterior Construction | Powder-coated aluminum |
| Transparent Panels | Chemically resistant acrylic |
| Spill Tray | Removable fiberglass |
| Work Area Lighting | Fluorescent |
| Electrical Requirements | Manufacturer's 30" Aura family: 115 V, 60 Hz, 3 A; verify nameplate |
| External Ductwork | Not required for approved ductless applications |
| Condition | Used and reconditioned |
| Warranty | 90 days |
Specifications reflect the AIE-listed unit where available. Manufacturer documentation for the broader 30-inch Aura family lists different airflow and exterior-height values; these should be reconciled against the individual unit before publication.
The primary difference between a ductless chemical fume hood and a conventional ducted fume hood is how contaminated air is managed.
A ducted chemical fume hood captures chemical vapors and exhausts them outside the building through an appropriate ventilation system.
The Misonix Aura 250L instead relies on chemical-specific filtration to remove compatible contaminants before returning air to the laboratory.
This can reduce installation complexity and eliminate the need for dedicated exhaust ductwork. It may also help avoid the energy costs associated with continuously exhausting conditioned laboratory air.
However, ductless operation introduces additional responsibilities involving chemical compatibility, filter selection, filter replacement, and breakthrough monitoring.
A ductless fume hood is not a universal replacement for a conventional chemical fume hood. Laboratories should select the appropriate ventilation equipment based on their chemical inventory and operating procedures.
Proper installation of the Aura 250L begins with identifying the chemicals and procedures that will be used inside the enclosure.
The laboratory should confirm that the selected filtration media is appropriate for those substances and that expected vapor concentrations and operating durations fall within the manufacturer's recommended limits.
The enclosure should be positioned away from doors, high-traffic areas, and other sources of disruptive airflow.
Because the blower is integrated, external exhaust ductwork is not required for approved recirculating applications. The laboratory must still provide appropriate electrical service and adequate clearance around the enclosure.
Before hazardous chemical use, the installed filters should be inspected, the airflow and alarm functions verified, and the complete system evaluated under representative operating conditions.
This Misonix Aura 250L is used and reconditioned by American Instrument Exchange.
Our technicians inspect the enclosure's structural condition, sash, lighting, blower, controls, and other applicable components as part of the refurbishment process.
The integrated blower and electronic monitoring system are important components of this model and should be evaluated for proper operation.
Because the Aura relies on application-specific filtration, the condition, type, and remaining service life of the installed chemical filters should be confirmed before the enclosure is placed into service.
Final airflow verification and filter suitability assessment should be completed at the installation site.
The compact 30-inch configuration makes the Aura 250L relatively easy to incorporate into an existing laboratory layout compared with a larger conventional fume hood.
Before ordering, laboratories should verify the available bench space, supporting surface capacity, electrical requirements, and clearance needed for sash operation and filter servicing.
American Instrument Exchange can assist with equipment information, photographs, and shipping arrangements to help customers plan their installation.
American Instrument Exchange offers a wide selection of refurbished chemical fume hoods for laboratories requiring either ductless filtration or conventional external exhaust.
For procedures involving hazardous powders rather than chemical vapors, laboratories may also consider specialized balance enclosures and particulate containment systems. AIE supplies analytical and precision balances for sample preparation and weighing applications, along with biosafety cabinets and clean benches for other laboratory protection requirements.
Purchasing a refurbished Misonix Aura 250L can provide laboratories with a cost-effective way to add chemical-handling containment without investing in an entirely new ductless fume hood.
The integrated blower, electronic airflow monitoring, hydrocarbon breakthrough sensing, and filter saturation alerts make the Aura 250L an attractive option for laboratories seeking a compact chemical filtration enclosure with advanced operating controls.
American Instrument Exchange specializes in used and refurbished laboratory equipment, helping research, pharmaceutical, industrial, and educational facilities obtain quality equipment at a lower cost than purchasing new.
This Misonix Aura 250L includes a 90-day warranty from American Instrument Exchange.
The Aura 250L is a ductless chemical fume hood designed for selected laboratory procedures involving compatible chemical vapors, fumes, and odors. It provides localized personnel protection through controlled inward airflow and application-specific filtration.
Yes. The Aura 250L includes an integrated blower motor that moves air through the enclosure and filtration system. A separate external exhaust blower is not required for approved ductless operation.
No. The Aura 250L is designed to operate as a recirculating ductless fume hood when equipped with suitable filtration for the intended chemicals.
The Aura platform supports application-specific activated carbon and other filter options. However, the exact filters included with this individual refurbished unit should be confirmed with American Instrument Exchange before purchase. A suitable filter must be installed before chemical use.
The Aura incorporates a hydrocarbon vapor sensor intended to detect certain organic vapor breakthrough conditions. It should not be assumed capable of detecting every chemical or indicating breakthrough for substances outside its sensing capabilities.
The electronic control system monitors operating conditions and adjusts blower performance to help maintain appropriate airflow. The enclosure also provides low-airflow alarms to alert operators when performance may be inadequate.
Filtrak is Misonix's filter-retention system designed to provide a secure seal around the installed filter and reduce the potential for contaminated air to bypass the filtration media.
Potentially, depending on the solvent, quantities used, and installed filter media. Each intended solvent must be evaluated for compatibility with the filtration system. Some chemicals and procedures are unsuitable for ductless recirculating containment.
The Aura family supports filtration configurations for certain particulate applications, including HEPA filtration options. Powder handling requires an appropriate installed filter and verification that the enclosure meets the application's containment requirements.
Not automatically. Suitability depends on the specific chemical, its exposure limits, expected vapor generation, filtration capacity, and manufacturer guidance. Highly toxic or poorly adsorbed chemicals may require an externally exhausted fume hood.
American Instrument Exchange lists this unit at 30 inches wide, 28 inches deep, and 48 inches high. Manufacturer documentation for the 30-inch Aura family gives a 50-inch height, so the individual unit should be measured to confirm installation clearance.
Yes. American Instrument Exchange includes a 90-day warranty with this used and reconditioned Misonix Aura 250L.
Want to see a video of this unit? Click Here to see the Misonix Aura 250L ductless fume hood on the American Instrument Exchange YouTube channel.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.