Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Mettler Toledo XPR20002L Delta Range Precision Balance

Fully Tested & Warrantied*
Brand : Mettler Toledo
Product Code : SKU 0662H BALANCE

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Mettler Toledo XPR20002L Delta Range Precision Balance

The Mettler Toledo XPR20002L Delta Range Precision Balance delivers exceptional weighing accuracy, high capacity performance, and advanced compliance features for demanding laboratory and industrial environments. Designed for applications requiring both high capacity and fine readability, the XPR20002L offers DeltaRange dual-range technology, providing enhanced resolution at lower weights without sacrificing maximum capacity.

With a maximum capacity of 22,000 g (22 kg) and fine readability down to 0.1 g in the lower range, this advanced precision balance ensures outstanding repeatability, fast stabilization, and full data integrity support. Combined with SmartPan technology and optional LabX software integration, the XPR20002L goes beyond weighing to deliver secure, compliant, and highly efficient workflows.

Mettler Toledo XPR20002L Features

  • Full range - 22,000g capacity (22kg), 1g readability
  • Fine range - 4,200g capacity, 0.1g readability
  • 280mm x 360mm pan
  • 90-day warranty

SmartPan for Faster, Stable Weighing

Thanks to integrated SmartPan technology, the XPR20002L delivers exceptional stability even in challenging environments such as fume hoods or production floors. The optimized pan design significantly reduces the effects of air turbulence, allowing results to stabilize up to twice as fast compared to conventional weighing pans. This improved stability enhances repeatability and reduces measurement variability.

Under standard laboratory conditions, the SmartPan allows certain applications to be performed without a draft shield, streamlining processes and improving ergonomics. In controlled environments like fume cupboards, operators may leave draft shield doors open during weighing, further reducing process steps and improving workflow efficiency.

Efficient Workflow Integration

The Mettler Toledo XPR20002L Delta Range Precision Balance is engineered to improve laboratory productivity through intelligent workflow support. Frequently used weighing methods can be saved directly in the balance’s internal method library, ensuring consistent execution of recurring tasks. Users simply select the stored method to access predefined parameters, minimizing setup time and reducing human error.

The balance features a large, color touchscreen interface that operates similarly to a smartphone, allowing intuitive navigation, swipe gestures, and multi-finger data entry. The display remains responsive even when wearing chemically resistant laboratory gloves.

A built-in results notepad automatically records task parameters and measurement data, eliminating the need for manual transcription. Results can be transferred via USB to a PC or printed directly when connected to compatible peripherals such as printers or barcode readers. These connectivity options allow seamless integration into laboratory data management systems and production environments.

Compliance & Quality Assurance

The XPR20002L is designed to meet the highest regulatory standards, making it ideal for pharmaceutical, chemical, and regulated laboratory environments. Immediately after initial setup, the balance begins monitoring critical quality parameters such as leveling, adjustment status, and operational readiness.

The integrated StatusLight indicator provides a clear visual signal showing whether the balance is ready for accurate weighing. This status is recorded with each measurement result, adding an additional layer of process security and traceability.

The optional GWP Approved function actively monitors the safe weighing range, ensuring measurements are performed within validated parameters. Tolerance profiles can be configured to alert users if results fall outside predefined specifications, ensuring compliance with internal quality standards and external regulations.

When paired with Mettler Toledo LabX software, the XPR20002L supports centralized data management, automated QA scheduling, SOP-guided user workflows, and secure audit trails. LabX assists with FDA 21 CFR Part 11 compliance by securely storing all results and process data in a central database, ensuring full traceability and data integrity.

Durable, Chemical-Resistant Construction

Built for long-term reliability, the XPR20002L features integrated overload protection to safeguard the weighing cell from accidental overload. Its full metal housing and protective covers shield internal components from dust, splashing liquids, and harsh chemicals. Smooth surfaces and rounded edges make cleaning quick and simple, helping maintain laboratory hygiene and performance consistency.

Mettler Toledo XPR20002L Delta Range Precision Balance Specifications 

Specification Details
Model Mettler Toledo XPR20002L
Capacity (Max) 22,000 g (22 kg)
DeltaRange Fine Range 0 – 4,200 g
Readability (Fine Range) 0.1 g
Readability (Standard Range) 1 g
Repeatability (Typical) 0.15 g (fine range)
Linearity ±0.3 g
Pan Size Approx. 280 × 360 mm
Stabilization Time Fast stabilization with SmartPan technology
Display Color touchscreen, multi-touch capability
Connectivity USB, Ethernet, RS232 (model dependent)
Software Compatibility LabX Laboratory Software
Compliance Support GWP Approved (optional), FDA 21 CFR Part 11 (with LabX)
Construction Full metal housing with overload protection
Application Areas QC labs, pharmaceuticals, chemical analysis, production environments

 

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.