Thermo Scientific Savant SpeedVac™ SPD120 Vacuum Concentrator System

Fully Tested & Warrantied*
Product Code : SKU 1340UU CENTIR
Sold Out

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System

The Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System is a complete vacuum evaporation solution designed for rapid concentration and drying of DNA, RNA, proteins, peptides, HPLC fractions, PCR products, and other biological samples. This complete refurbished system from American Instrument Exchange includes the Thermo Scientific SPD120-115 vacuum concentrator, the Thermo Scientific RVT5105-115 ultra-low temperature refrigerated vapor trap, and the Thermo Scientific VLP-120 high-vacuum pump. Working together, these components provide efficient solvent evaporation while protecting valuable samples and extending vacuum pump life, making the system ideal for molecular biology, genomics, proteomics, pharmaceutical research, and analytical laboratories.

Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System Key Features

  • Complete Thermo Scientific Savant SpeedVac vacuum concentration system

  • Includes SPD120-115 vacuum concentrator

  • Includes RVT5105-115 refrigerated vapor trap

  • Includes VLP-120 high-vacuum pump

  • Medium-capacity centrifugal vacuum concentrator

  • PTFE-coated aluminum chamber

  • Glass safety lid with soft-close mechanism

  • Temperature settings from ambient to 80°C

  • Three programmable operating methods

  • USB data export capability

  • Ultra-low temperature vapor trap operates to -105°C

  • High-vacuum rotary vane pump

  • Designed for aqueous and organic solvent evaporation

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included from American Instrument Exchange

Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System Overview

The SpeedVac SPD120 system combines centrifugal force, vacuum, and controlled heating to rapidly concentrate samples while minimizing the risk of sample loss caused by bumping or overheating. The included RVT5105 refrigerated vapor trap condenses water vapor and organic solvents before they reach the vacuum pump, protecting the VLP-120 pump while improving overall system performance. The modular design allows researchers to process a wide variety of sample types including nucleic acids, proteins, peptides, HPLC fractions, and pharmaceutical compounds. The intuitive touchscreen interface, programmable methods, and temperature control make the SPD120 system suitable for both routine laboratory use and high-throughput research environments.

Common Applications for the Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System

The Thermo Scientific SpeedVac SPD120 is commonly used for concentrating DNA and RNA samples, drying PCR products, peptide and protein preparation, solvent removal following HPLC purification, sample preparation for mass spectrometry, concentration of pharmaceutical compounds, natural product extracts, metabolomics research, and molecular biology workflows. The system is compatible with many commonly used laboratory solvents including water, methanol, ethanol, acetonitrile, and aqueous solvent mixtures.

Ideal Lab Types for the Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System

This vacuum concentrator system is well suited for molecular biology laboratories, genomics facilities, proteomics laboratories, pharmaceutical companies, biotechnology companies, forensic laboratories, academic research institutions, clinical research laboratories, and analytical chemistry laboratories. Facilities utilizing centrifuges, biosafety cabinets, CO₂ incubators, and ultra-low freezers frequently incorporate SpeedVac systems into their sample preparation workflows.

Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System Key Specifications

Specification Details
Manufacturer Thermo Scientific
Vacuum Concentrator SPD120-115
Refrigerated Vapor Trap RVT5105-115
Vacuum Pump VLP-120
Equipment Type Vacuum Concentrator System
Sample Heating Range Ambient to 80°C
Chamber Material PTFE-Coated Aluminum
Lid Glass Safety Lid with Soft-Close Mechanism
Rotor Speed Approximately 1,630 RPM (60 Hz)
Vapor Trap Temperature -105°C
Vapor Trap Capacity 4 Liters
User Programs 3 Programmable Methods
Data Export USB Port
SPD120 Dimensions 13" W × 18" D × 14" H
SPD120 Weight 57 lbs
Electrical Requirements 115V, 60 Hz
Applications DNA, RNA, Protein, Peptide, HPLC, PCR Sample Concentration

Specifications compiled from Thermo Scientific manufacturer literature, distributor technical references, and American Instrument Exchange product information.

Refurbishment and Testing Process

At American Instrument Exchange, each refurbished SpeedVac system is inspected and evaluated by our technicians prior to shipment. Testing procedures may include verification of concentrator rotation and heating functions, controller operation, lid locking mechanism, vapor trap cooling performance, vacuum pump operation, system vacuum integrity, and overall operational performance. Components showing excessive wear are addressed as needed to help ensure dependable laboratory operation. Final cleaning and inspection are completed before packaging and shipment.

Shipping and Installation Considerations

The Thermo Scientific Savant SpeedVac SPD120 system should be installed on a stable laboratory bench with adequate ventilation around each component. The refrigerated vapor trap should always be installed between the concentrator and the vacuum pump to protect the pump from solvent vapors. Buyers should verify adequate bench space, electrical service, and ventilation requirements before installation. Because this listing includes three separate components, the system is carefully packaged for freight shipment to protect all equipment during transport.

Related Laboratory Equipment

Laboratories purchasing SpeedVac systems often also require centrifuges, ultra-low freezers, biosafety cabinets, CO₂ incubators, and laboratory refrigerators. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support molecular biology, pharmaceutical research, analytical chemistry, and biotechnology workflows.

Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System Frequently Asked Questions

What components are included with this SpeedVac system?

This system includes the Thermo Scientific SPD120-115 vacuum concentrator, the RVT5105-115 ultra-low temperature refrigerated vapor trap, and the VLP-120 high-vacuum pump, providing a complete vacuum concentration solution ready for laboratory installation.

What is the purpose of the refrigerated vapor trap?

The RVT5105 condenses water vapor and organic solvents at temperatures as low as -105°C before they reach the vacuum pump, helping improve evaporation efficiency while extending vacuum pump life.

What types of samples can the SPD120 process?

The SPD120 is commonly used to concentrate DNA, RNA, proteins, peptides, PCR products, HPLC fractions, and other biological or analytical samples following purification or extraction.

Can this system be used with aqueous and organic solvents?

Yes. The SPD120 platform is designed for use with many common laboratory solvents including water, methanol, ethanol, acetonitrile, and aqueous solvent mixtures used in molecular biology and analytical chemistry.

What warranty is included?

This refurbished Thermo Scientific Savant SpeedVac SPD120 Vacuum Concentrator System includes a 90-day warranty from American Instrument Exchange.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.