VACUUBRAND MZ 2C NT +AK+EK Chemistry Diaphragm Pump - NEW
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The VACUUBRAND MZ 2C NT +AK+EK Chemistry Diaphragm Vacuum Pump System is a chemically resistant, oil-free laboratory vacuum system designed for rotary evaporation, vacuum concentration, vacuum drying, evaporation, evacuation, and pumping chemical gases and vapors. Built around the proven two-stage MZ 2C NT chemistry diaphragm pump, this configuration combines a protective inlet separator with a high-efficiency EK waste-vapor condenser, providing both pump protection and effective solvent recovery.
With an ultimate vacuum of 7 mbar (5 Torr) and maximum pumping speed of 1.4 cfm at 60 Hz, the MZ 2C NT +AK+EK provides the vacuum performance needed for many laboratory solvent-processing applications while eliminating the oil maintenance associated with rotary vane vacuum pumps. The integrated exhaust condenser captures solvent vapor after it passes through the pump, helping reduce emissions and allowing recovered solvent to be collected for appropriate reuse or disposal.
This brand-new VACUUBRAND MZ 2C NT +AK+EK chemistry vacuum system is available from American Instrument Exchange and is an excellent choice for pharmaceutical, biotechnology, chemistry, academic, and industrial laboratories seeking reliable chemical vacuum with integrated liquid protection and solvent recovery.
Brand-new VACUUBRAND MZ 2C NT +AK+EK chemistry vacuum system
Oil-free chemistry diaphragm pump technology
Outstanding chemical resistance and vapor tolerance
7 mbar / 5 Torr ultimate vacuum
1.4 cfm maximum pumping speed at 60 Hz
Two-head, two-stage diaphragm pump
AK protective inlet separator
Inlet separator captures particles and liquid droplets
EK high-efficiency waste-vapor condenser
Excellent solvent recovery at the pump exhaust
Helps reduce solvent emissions
Well suited for rotary evaporators
Excellent choice for vacuum concentrators
Suitable for vacuum drying ovens
Gas ballast for improved condensable-vapor handling
High performance at low vacuum levels
Quiet operation at approximately 45 dBA
Very low vibration
Oil-free operation reduces routine maintenance
NRTL-certified U.S. configuration
Available brand new from American Instrument Exchange
The VACUUBRAND MZ 2C NT +AK+EK is designed for laboratory processes where chemical resistance and solvent recovery are both important.
At the center of the system is the MZ 2C NT, a two-stage chemistry diaphragm pump capable of reaching an ultimate vacuum of 7 mbar. This provides substantially deeper vacuum than general-purpose filtration pumps and makes the system suitable for evaporation, concentration, drying, and other processes involving reduced pressure.
The +AK+EK configuration adds two important components.
On the inlet side, the protective-coated glass AK separator captures particles and liquid droplets before they enter the pump. This provides an additional layer of protection during processes such as rotary evaporation, where foaming or bumping can potentially carry liquid into the vacuum line.
On the exhaust side, the EK waste-vapor condenser captures solvent vapor after it passes through the pump. This compact condenser is designed for efficient solvent recovery, reducing the quantity of vapor released from the vacuum system.
Together, these features make the MZ 2C NT +AK+EK particularly well suited for solvent-processing applications where protecting the pump and recovering solvent are both priorities.
| Specification | Details |
|---|---|
| Manufacturer | VACUUBRAND |
| Model | MZ 2C NT +AK+EK |
| Equipment Type | Chemistry Diaphragm Vacuum System |
| U.S. Catalog / Article Number | 20732603 |
| Pump Design | Oil-Free Chemistry Diaphragm |
| Number of Heads | 2 |
| Number of Stages | 2 |
| Maximum Pumping Speed at 60 Hz | 1.4 cfm |
| Maximum Pumping Speed at 50 Hz | 2.0 m³/h |
| Ultimate Vacuum | 7 mbar / 5 Torr |
| Ultimate Vacuum with Gas Ballast | 12 mbar / 9 Torr |
| Maximum Outlet Pressure | 1.1 bar absolute |
| Inlet Separator | AK Protective-Coated Glass Separator |
| Exhaust Condenser | EK Waste-Vapor Condenser |
| Inlet Connection | Hose Nozzle DN 8–10 mm |
| Outlet Connection | Hose Nozzle DN 8–10 mm |
| Coolant Connections | 2 × Hose Nozzle DN 6–8 mm |
| Rated Motor Power | 0.18 kW / 180 W |
| Rated Motor Speed | 1500 rpm at 50 Hz / 1800 rpm at 60 Hz |
| Operating Ambient Temperature | 10°C to 40°C |
| Storage Temperature | -10°C to 60°C |
| Dimensions (L × W × H) | 326 × 243 × 402 mm (12.8 × 9.6 × 15.8 in.) |
| Weight | 14.2 kg (31.3 lb) |
| Sound Pressure Level | Approximately 45 dBA |
| Protection Class | IP40 |
| Certification | NRTL Certified |
| Condition | Brand New |
Energy Efficiency & Operating Costs
The MZ 2C NT +AK+EK uses a 180-watt motor and completely oil-free diaphragm pumping mechanism. Unlike an oil-sealed rotary vane pump, there is no vacuum pump oil to purchase, monitor, change, or dispose of.
Oil-free operation is particularly valuable when processing solvents because solvent vapors cannot contaminate a pump-oil reservoir. It also eliminates oil mist and the possibility of oil backstreaming into connected laboratory equipment.
The integrated EK condenser provides another potential operating benefit by recovering solvent vapor that would otherwise leave the pump exhaust. Depending on the process and purity requirements, recovered solvent may be suitable for recycling or can be collected for controlled disposal.
The AK separator can further contribute to pump longevity by helping prevent accidental liquid carryover from reaching the pump heads.
The VACUUBRAND MZ 2C NT +AK+EK is particularly well suited for rotary evaporation, vacuum concentration, vacuum drying ovens, solvent evaporation, evacuation, degassing, and pumping gases and chemical vapors.
VACUUBRAND specifically identifies rotary evaporators, vacuum concentrators, and vacuum drying ovens as typical applications for this configuration.
The combination of 7 mbar ultimate vacuum, chemical resistance, inlet liquid protection, and exhaust-side solvent recovery makes this a versatile vacuum system for laboratories regularly working with volatile solvents.
The MZ 2C NT +AK+EK is an excellent choice for pharmaceutical research laboratories, biotechnology companies, medicinal chemistry groups, organic chemistry laboratories, analytical laboratories, university research facilities, contract research organizations, process-development laboratories, quality-control facilities, and industrial R&D departments.
It is especially useful in laboratories where vacuum pumps routinely encounter solvent vapor and where reducing solvent discharge from the pump exhaust is desirable.
The EK exhaust condenser is the defining feature of this MZ 2C NT configuration.
Solvent vapor drawn from an evaporation or drying process travels through the vacuum pump. Rather than simply discharging that vapor through the pump exhaust, the EK condenser cools the exhaust stream so that solvent vapor can condense and be collected.
This provides several potential benefits:
Improved solvent recovery
Reduced solvent emissions
Controlled collection of condensed solvent
Potential solvent recycling where appropriate
Reduced vapor load on laboratory exhaust systems
Improved environmental performance of solvent-processing workflows
VACUUBRAND describes the EK as a highly efficient, compact waste-vapor condenser designed to enable very high levels of solvent recovery.
While the EK condenser protects the exhaust side of the process, the AK inlet separator helps protect the vacuum pump itself.
The separator is constructed from protective-coated glass and is designed to capture liquid droplets and particles before they enter the pump.
This is particularly useful during evaporation. If a sample bumps or foams, liquid can potentially be carried into the vacuum line. The AK separator provides a physical collection point before that liquid reaches the diaphragm heads.
Reducing liquid carryover can help minimize pump contamination, protect chemically resistant components, and extend equipment life.
The MZ 2C NT +AK+EK is particularly well suited as a chemistry vacuum pump for rotary evaporators.
Rotary evaporation requires sufficient vacuum to reduce solvent boiling temperature while maintaining stable evaporation conditions. The MZ 2C NT reaches 7 mbar, providing useful vacuum performance for many common laboratory solvents.
The AK separator helps protect the pump if liquid is carried over from the evaporator, while the EK exhaust condenser provides an additional solvent-recovery stage after vapor passes through the pump.
This combination creates a practical vacuum solution for laboratories that want oil-free rotary evaporation with integrated solvent recovery but do not require automatic electronic vacuum control.
VACUUBRAND also identifies vacuum concentrators as a typical application for this system.
Vacuum concentrators remove solvent from samples under reduced pressure, frequently producing substantial vapor loads during operation. A chemistry-resistant diaphragm pump eliminates the oil contamination issues that can occur when solvent vapor enters a rotary vane pump.
The EK condenser provides additional value by capturing solvent from the exhaust stream, while the AK separator protects against accidental liquid aspiration.
The MZ 2C NT +AK+EK can also serve as a vacuum pump for compatible laboratory vacuum drying ovens.
Vacuum ovens are commonly used to remove moisture, residual solvents, and other volatile materials at reduced pressure. When solvent vapor is present, chemical resistance and exhaust management become particularly important.
The MZ 2C NT provides oil-free chemical vacuum while the EK condenser helps capture condensable vapor leaving the pump.
Actual suitability should always be evaluated against the oven manufacturer's required pumping speed, target pressure, chamber volume, vapor load, and materials being processed.
The MZ 2C NT is designed specifically as a chemistry diaphragm vacuum pump.
Wetted components are selected to provide strong resistance to many chemicals and solvents commonly encountered in research and process laboratories. The diaphragm design also hermetically separates the pumping chamber from the drive mechanism.
This makes the MZ 2C NT platform especially useful for processes where chemical vapors would quickly contaminate the oil in a conventional rotary vane vacuum pump.
Chemical compatibility should always be verified for the specific substances, concentrations, temperatures, and process conditions involved.
The MZ 2C NT +AK+EK reaches approximately 7 mbar / 5 Torr without gas ballast and 12 mbar / 9 Torr with gas ballast.
Gas ballast can improve the pump's ability to handle condensable vapors by helping purge condensate from the pumping system.
This capability is especially useful during evaporation, vacuum drying, and concentration processes where water vapor or solvent vapor may be present continuously.
Both systems use the same basic two-stage MZ 2C NT chemistry diaphragm pump and provide approximately the same ultimate vacuum, but the outlet-side equipment differs significantly.
The MZ 2C NT +2AK uses separators at both the inlet and outlet. Its outlet separator collects condensate and helps prevent condensate backflow toward the pump.
The MZ 2C NT +AK+EK replaces that basic outlet separator with a high-efficiency waste-vapor condenser designed for active solvent recovery.
For general vacuum concentration, gel drying, or processes where simple condensate collection is sufficient, the +2AK configuration may be appropriate.
For rotary evaporation, vacuum drying, and solvent-processing applications where maximizing solvent recovery and reducing emissions are priorities, the +AK+EK configuration provides a significant advantage.
These two MZ 2C NT configurations are optimized for different workflows.
The +AK+M+D configuration combines an inlet separator with a manual flow-control valve and analog vacuum manometer. It is particularly useful for filtration, solid-phase extraction, and other applications where the operator wants direct manual vacuum adjustment.
The +AK+EK configuration emphasizes solvent handling and recovery. Instead of the manual valve and manometer, it adds a high-efficiency exhaust condenser.
For filtration and manual vacuum control, the +AK+M+D is the stronger choice. For evaporation, concentration, vacuum drying, and solvent recovery, the +AK+EK configuration is generally the better fit.
The MZ 2C VARIO Select and MZ 2C NT +AK+EK both use oil-free chemistry diaphragm technology and reach approximately 7 mbar, but they solve different problems.
The MZ 2C VARIO Select emphasizes automatic process control. Its VACUU·SELECT controller and variable-speed motor can automatically regulate vacuum during solvent evaporation.
The MZ 2C NT +AK+EK emphasizes solvent recovery, combining a fixed-speed MZ 2C NT pump with an inlet separator and exhaust condenser.
A laboratory primarily concerned with automated rotary evaporation may prefer the VARIO Select. A laboratory that prioritizes straightforward operation and efficient exhaust-side solvent recovery may prefer the +AK+EK.
The PC 3001 VARIO Select TE represents a more advanced solution for demanding evaporation processes.
The MZ 2C NT +AK+EK reaches 7 mbar and provides fixed-speed chemical vacuum with an AK inlet separator and EK exhaust condenser.
The PC 3001 VARIO Select TE reaches approximately 2 mbar and adds automatic VACUU·SELECT process control, variable-speed operation, and a dry-ice exhaust condenser.
For many routine rotary evaporation, concentration, and vacuum drying workflows, the MZ 2C NT +AK+EK provides an effective and comparatively straightforward solution. Laboratories requiring deeper vacuum, automatic boiling-pressure control, or work with more challenging high-boiling solvents may benefit from the PC 3001 VARIO Select TE.
The VACUUBRAND MZ 2C NT +AK+EK is recommended for:
Rotary evaporation
Vacuum concentrators
Vacuum drying ovens
Solvent evaporation
Sample concentration
Organic chemistry
Pharmaceutical research
Medicinal chemistry
Chemical synthesis
Reaction workup
Degassing
Laboratory evacuation
Chemical-vapor pumping
Solvent recovery applications
Application suitability should always be evaluated according to required pressure, pumping speed, vapor load, chemical compatibility, and process conditions.
American Instrument Exchange offers the VACUUBRAND MZ 2C NT +AK+EK brand new, providing laboratories with current VACUUBRAND chemistry diaphragm vacuum technology from an established laboratory equipment supplier.
American Instrument Exchange offers multiple new VACUUBRAND vacuum technologies for different laboratory applications, including general-purpose diaphragm pumps, chemically resistant diaphragm pumps, manually regulated vacuum systems, VARIO electronically controlled pumps, rotary vane pumps, and Chemistry-HYBRID vacuum pumps.
The growing VACUUBRAND selection allows laboratories to choose vacuum equipment based on actual process requirements—from filtration and aspiration to rotary evaporation, vacuum concentration, solvent recovery, drying, freeze drying, and fine-vacuum research.
The VACUUBRAND MZ 2C NT +AK+EK is supplied as a completely assembled pumping unit ready for use.
The system measures approximately 12.8" L × 9.6" W × 15.8" H and weighs approximately 31.3 lb, allowing installation beside many laboratory evaporators, concentrators, and vacuum ovens.
The inlet and outlet use DN 8–10 mm hose nozzles, while the EK condenser incorporates two DN 6–8 mm coolant hose connections.
Because the EK is an actively cooled exhaust condenser, an appropriate coolant source and tubing arrangement should be provided according to VACUUBRAND recommendations and the solvent-processing application.
Vacuum and coolant tubing should be compatible with the materials being processed. Laboratories handling hazardous, toxic, flammable, or corrosive vapors should also provide appropriate ventilation, exhaust routing, and process-specific engineering controls.
Laboratories purchasing chemistry diaphragm vacuum systems frequently also require rotary evaporators, vacuum concentrators, vacuum ovens, recirculating chillers, cold traps, solvent recovery equipment, laboratory reactors, analytical balances, freeze dryers, and chemical fume hoods.
American Instrument Exchange offers new and refurbished laboratory equipment for pharmaceutical research, biotechnology, organic chemistry, analytical laboratories, process development, academic research, and industrial R&D.
The system is designed for evacuation, evaporation, and pumping gases and vapors in chemical, biological, and pharmaceutical laboratories. Typical applications include rotary evaporators, vacuum concentrators, and vacuum drying ovens.
The MZ 2C NT +AK+EK reaches an ultimate vacuum of 7 mbar, or approximately 5 Torr.
Maximum pumping speed is 2.0 m³/h at 50 Hz or approximately 1.4 cfm at 60 Hz.
The AK is the protective inlet separator, which captures particles and liquid droplets before they enter the pump. The EK is the high-efficiency waste-vapor condenser installed at the pump exhaust for solvent recovery.
The EK condenser cools vapor leaving the pump so that condensable solvent can be collected rather than simply discharged with the pump exhaust. This improves solvent recovery and helps reduce emissions.
VACUUBRAND describes the compact EK condenser as enabling near-100% solvent recovery under appropriate operating conditions. Actual recovery will depend on the solvent, coolant temperature, vapor load, flow conditions, and application.
Yes. The MZ 2C NT +AK+EK includes two DN 6–8 mm coolant connections for the waste-vapor condenser. An appropriate cooling source is required for condenser operation.
Yes. Rotary evaporators are one of the typical applications specifically identified by VACUUBRAND for this configuration.
Yes. VACUUBRAND specifically identifies vacuum concentrators as a typical application for the MZ 2C NT +AK+EK.
Yes. VACUUBRAND identifies vacuum drying ovens as another typical application. Suitability should be confirmed against the particular oven's chamber volume, required pressure, vapor load, and pumping-speed requirements.
Yes. It uses oil-free chemistry diaphragm pump technology, eliminating vacuum pump oil changes, oil mist, and oil backstreaming.
Yes. The MZ 2C NT platform is designed for excellent chemical resistance and superior vapor tolerance. Chemical compatibility should nevertheless be verified for the specific materials and operating conditions involved.
The +2AK configuration uses inlet and outlet separators for liquid and condensate management. The +AK+EK configuration adds a high-efficiency exhaust condenser specifically designed for solvent recovery, making it particularly attractive for evaporation and solvent-processing applications.
No. This is a fixed-speed chemistry vacuum system. Laboratories requiring automatic pressure regulation and boiling-point detection should consider an appropriate VACUUBRAND VARIO Select system.
VACUUBRAND specifies a sound pressure level of approximately 45 dBA, providing quiet operation for occupied laboratory environments.
The system measures approximately 12.8" L × 9.6" W × 15.8" H and weighs approximately 31.3 lb.
No. This VACUUBRAND MZ 2C NT +AK+EK Chemistry Diaphragm Vacuum Pump System is brand new, not refurbished or previously used, and is available from American Instrument Exchange.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.