All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Thermo Scientific Forma 3940 Reach-in Refrigerated Incubator
29 cu. ft.
Temperature range: 0°C to 60°C
Dual LED humidity displays
Humidity control range: above ambient to 95%
90-day warranty
Forma Reach-in refrigerated incubator chambers are perfect for applications that require temperature control below and/or above ambient, e.g. storage, testing, and incubation at low temperatures. The refrigerated incubator chambers meet International Conference on Harmonization (ICH) guidelines for drug substance and product storage testing. The units are ideal for drug stability studies, shelf life testing for packaged products, and insect and other large-scale biological research.
Click Here to see a video of the Thermo Forma 3940 Incubator on our YouTube channel.
These chambers feature a 0°C to 60°C (32°F to 140°F) temperature range that can be set in 0.1°C increments. The broad temperature range, and optimum temperature uniformity and recovery contribute to an ideal test environment, even when the chamber contains large product loads and low-output, heat-generating equipment. They also feature a humidity control system, which allow you to set the RH level between ambient and 95% in 1% increments. The humidity system requires a water purity in the resistance range of 50K to 1M Ohm/cm, or a conductivity range of 20.0 to 1.0 uS/cm. The water source can be either pressurized (up to 40PSI) or unpressurized. If an in-house water supply of the required purity range is not available, an alternate method can be used. A large, vended carboy (5 gal. minimum) of water in the required purity range can be placed on top of the unit.
This combination directs air across the surface of each solid shelf. Even when filled with samples or equipment, each shelf receives a consistent flow of conditioned air for optimum temperature uniformity and recovery. As opposed to a horizontal airflow system, top-to-bottom (non-directed) airflow systems use a top-mounted fan to push air down through wire shelves. Temperature uniformity and recovery can deteriorate quickly when shelves are filled because air movement is blocked. That variation in temperature, alone or when combined with frequent door openings, may compromise environmental conditions, or make process validation difficult.
The Thermo Scientific Directed Airflow System promotes an ideal growth environment. The enhanced design includes a positive pressure feed plenum on the right side of the chamber and a negative pressure return plenum on the left to distribute the airflow uniformly throughout the chamber.
Most of our equipment
is used and reconditioned. Our technicians test incubators using a calibrated digital chart recorder to verify the accuracy of temperature controls and readouts. We replace any hardware or parts as is necessary and clean all incubators thoroughly prior to shipment.
The photos above are representative. Please bear in mind that the equipment shown is currently in storage in our warehouse and that in addition to testing each machine we will clean all the equipment thoroughly prior to shipment. We often have multiple units of each model in stock and sometimes we're unable to feature photos of every single unit. At your request, we can provide photos of the equipment in your order after it has been tested and cleaned.
Thermo Scientific Forma 3940 Reach-in Refrigerated Incubator- Specifications
External dimensions
38”W x 32”D x 88.5”H
Internal dimensions
31”W x 27”D x 60”H
Chamber volume
29 cu. ft.
Temperature range
0°C to 60°C
Temperature accuracy
Temperature resolution
0.1°C
Temperature uniformity
±0.3 at 25° to 37°C
Humidity range
above ambient to 95%
Humidity accuracy
±5.0%
Humidity readability
1%
Electrical requirements
208/220 V, 60 Hz
For inquiries about the Thermo Forma 3940, please give us a call at 978-521-2221, or fill out the form on this page.
FAQ
Does the equipment come with a warranty?
Yes, all equipment from American Instrument Exchange comes with a warranty. Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
How do you test and recondition the equipment?
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality. We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
How do products ship from American Instrument Exchange?
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
Return and order cancellation policy
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Are discounts available for educational or non-profit institutions, or for bulk purchases?
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
How does your price matching policy work?
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Can I see the equipment in person before committing to a purchase?
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Can I ship products that I purchased elsewhere to American Instrument for repair?
Yes – please see our repair services page for more information.