Forma 1184 Class II Type A2 biosafety cabinet

Fully Tested & Warrantied*
Brand : Forma
Product Code : SKU 0870D_BIO_CAB
Sold Out
⚠

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Thermo Forma 1184 Class II Type A/B3 Biosafety Cabinet Service, Certification & Replacement Options

The Thermo Forma 1184 is a legacy 4-foot Class II Type A/B3 biological safety cabinet designed to provide personnel and product protection for microbiology, cell culture, biotechnology, pharmaceutical research, clinical laboratories, universities, and other facilities working with biological materials.

Originally manufactured by Forma Scientific, the model 1184 belongs to an earlier generation of biological safety cabinets that predates today's more familiar Class II Type A2 terminology.

The Forma 1184 is a 4-foot cabinet with a sliding front window and a 10-inch operating sash opening. Its stainless-steel work surface and HEPA-filtered airflow system were designed to create a controlled work environment while protecting the operator from biological materials handled inside the cabinet.

One of the most important characteristics of the Forma 1184 is its original Type A/B3 designation.

The cabinet was designed so that filtered exhaust air could be discharged back into the laboratory when operated in its Type A configuration. Alternatively, the cabinet could be connected to an external building exhaust system and operated in its Type B3 configuration.

This flexibility made the Forma 1184 useful in many laboratories, but it also means that replacing one requires more consideration than simply finding another 4-foot cabinet.

If your Forma 1184 is used strictly for biological work and does not depend on external exhaust for chemical handling, a modern 4-foot Class II Type A2 cabinet may provide an appropriate replacement.

If the cabinet is connected to an external exhaust system or your procedures involve volatile chemicals, radionuclides, or other materials that influenced the original B3 configuration, the application and exhaust requirements should be reviewed before selecting a replacement.

American Instrument Exchange can help evaluate an aging Forma 1184 and determine whether continued service remains practical or whether a newer biosafety cabinet would provide better long-term value.

Common Thermo Forma 1184 Problems

The Forma 1184 was designed for long-term laboratory operation, but cabinets of this generation can eventually develop problems involving airflow, HEPA filters, blowers, controls, alarms, sash components, lighting, and electrical systems.

Common problems may include:

  • Failure to pass annual biosafety cabinet certification

  • Inflow or downflow velocity outside acceptable limits

  • HEPA filter leakage

  • Excessive HEPA filter loading

  • Blower motor deterioration

  • Difficulty maintaining proper airflow

  • Static-pressure gauge problems

  • Airflow instability

  • Sash-position problems

  • Worn sliding-window components

  • Lighting failures

  • Electrical problems

  • Damaged work surfaces or interior components

  • Exhaust-system or damper problems

  • Increasing difficulty sourcing model-specific components

  • Repeated adjustment required to pass certification

A Forma 1184 that fails certification does not automatically need to be replaced.

HEPA filter loading, airflow adjustment, blower performance, exhaust-system conditions, sash position, filter integrity, or another serviceable condition may be responsible.

The important question is whether the cabinet can be repaired and returned to stable, certifiable operation.

Is Your Thermo Forma 1184 Still Worth Repairing?

Potentially, yes.

The Forma 1184 was built as a substantial laboratory containment device, and an older cabinet that remains structurally sound may still provide useful service if its airflow system, blower, filters, sash, and other critical components remain functional.

An isolated repair may cost substantially less than replacing the cabinet.

HEPA filter replacement, airflow adjustment, blower service, electrical repair, lighting repair, sash work, or another targeted repair can potentially extend the useful life of an otherwise dependable Forma 1184.

The decision becomes more complicated when multiple aging systems require attention at the same time.

Repeated certification failures, deteriorating blower performance, difficult-to-source components, exhaust-control problems, damaged cabinet components, or repeated HEPA and airflow issues can make continued investment increasingly difficult to justify.

The application also matters.

A cabinet used for routine biological work may be relatively straightforward to evaluate for continued service.

A Forma 1184 being operated in its externally exhausted B3 configuration deserves additional consideration because the cabinet, exhaust connection, building exhaust system, and laboratory procedures all influence its safe operation.

When an aging Forma 1184 becomes increasingly difficult to maintain or certify reliably, replacement with a newer BSC may provide better long-term value.

Thermo Forma 1184 Repair, Service & Certification

American Instrument Exchange can help laboratories evaluate and maintain legacy biosafety cabinets, while biosafety cabinet certification and applicable field testing can determine whether the cabinet continues to perform appropriately.

Service requirements for an aging Forma 1184 may involve HEPA filters, blower performance, airflow adjustment, sash components, electrical systems, lighting, dampers, controls, or other cabinet components.

Certification is particularly important for a cabinet of this age.

A biological safety cabinet cannot be judged simply by whether the blower runs or air appears to be moving.

Its containment performance depends on specific airflow relationships and HEPA filter integrity that must be measured and tested.

If repairs are performed that affect cabinet containment or airflow, the cabinet should be appropriately tested and certified before being returned to normal laboratory service.

Understanding the Forma 1184 Type A/B3 Designation

The Type A/B3 terminology found on the Forma 1184 is part of an older biosafety cabinet classification system.

Forma designed the 1184 so that it could operate in two configurations.

When HEPA-filtered exhaust air was discharged directly back into the laboratory, the cabinet operated as a Type A cabinet.

When connected to an appropriate external building exhaust system, the cabinet could operate as a Type B3 cabinet.

In either configuration, approximately 40% of the cabinet's air was exhausted through the exhaust HEPA filter while the remainder was recirculated through the supply HEPA filtration system and returned to the work area.

Room air entering through the front access opening helped establish the air barrier responsible for personnel protection.

The distinction between these operating configurations is extremely important when planning a replacement.

A laboratory should not assume that any modern 4-foot Class II cabinet can automatically replace a Forma 1184 without considering how the existing cabinet is installed and what materials are handled inside it.

Why the Existing Exhaust Configuration Matters

Before replacing a Forma 1184, determine whether the existing cabinet exhausts filtered air directly into the room or is connected to an external building exhaust system.

If the cabinet is not externally exhausted and is used for conventional biological applications, replacing it with a modern Class II Type A2 cabinet may be relatively straightforward.

If the cabinet is connected to building exhaust, determine why.

The external exhaust may have been incorporated simply because of laboratory design preferences, or it may be related to the procedures and materials historically used inside the cabinet.

That distinction matters.

A laboratory using volatile toxic chemicals or tracer quantities of radionuclides in conjunction with microbiological work has different containment and exhaust requirements from a laboratory performing conventional cell culture.

Before changing cabinet type or removing an existing exhaust connection, the laboratory's current procedures should be reviewed by the appropriate biosafety, industrial hygiene, EHS, or facility personnel.

Replacement should be based on the current application rather than assuming that the way the cabinet was used decades ago remains appropriate today.

Certification Is More Important Than Cabinet Age

Age alone does not determine whether a Forma 1184 can remain in service.

Performance does.

The cabinet's HEPA filters must maintain integrity, the blower must provide appropriate airflow, the sash must operate correctly, and the cabinet must meet applicable certification requirements.

Some deterioration is obvious.

A noisy blower, damaged sash, malfunctioning light, or visibly damaged cabinet component can immediately indicate that service is required.

Airflow and HEPA filter problems may be less obvious.

A cabinet can sound normal and appear to be moving air while failing to maintain appropriate containment conditions.

Regular certification provides the objective measurements needed to evaluate actual performance.

A Forma 1184 that remains mechanically sound and consistently meets applicable certification requirements may still have useful service life.

One that requires increasingly frequent adjustments or repairs to achieve acceptable performance should be evaluated for replacement.

HEPA Filter Replacement on a Forma 1184

HEPA filters should not be replaced simply because they are old.

Their condition should be evaluated based on integrity, loading, resistance, airflow performance, and certification results.

As filters accumulate particulate material, resistance increases and the blower must work harder to maintain proper airflow.

Eventually, filter loading may prevent the cabinet from maintaining appropriate performance.

A filter may also require replacement when integrity testing identifies leakage that cannot be corrected appropriately.

Before investing in a complete filter replacement on a Forma 1184, consider the overall condition of the cabinet.

New filters may be a reasonable investment when the cabinet has a healthy blower, sound structure, functional sash, dependable electrical systems, and good prospects for continued certification.

If the cabinet simultaneously requires major blower, exhaust, sash, electrical, or structural work, replacement may provide better value.

When It Makes Sense to Upgrade a Thermo Forma 1184

A Forma 1184 that continues to operate reliably and pass certification does not need to be replaced solely because newer technology exists.

Replacement becomes more compelling when the cabinet experiences repeated certification failures, blower deterioration, excessive filter loading, recurring airflow problems, difficult-to-source components, sash problems, exhaust-system issues, or increasingly expensive service requirements.

Modern BSCs can also provide significant improvements in energy efficiency, lighting, airflow monitoring, ergonomics, motor technology, controls, noise levels, and serviceability.

For laboratories that rely heavily on a BSC every day, those improvements can provide meaningful operational benefits.

Planning replacement before a critical failure also allows the laboratory to evaluate its current containment requirements rather than making an emergency purchase based primarily on equipment availability.

Thermo Scientific 1300 Series: A Practical Modern Replacement

For a Forma 1184 used for conventional biological work that does not require a specialized externally exhausted cabinet, a modern 4-foot Thermo Scientific 1300 Series Class II Type A2 BSC provides a logical upgrade.

The Thermo 1300 Series retains a familiar 4-foot work format while moving the laboratory to a substantially newer generation of blower technology, airflow management, controls, ergonomics, and energy efficiency.

American Instrument Exchange regularly stocks 4-foot Thermo 1300 Series biosafety cabinets with stands and new HEPA filters.

For many cell culture, microbiology, biotechnology, pharmaceutical, and research laboratories, a refurbished 4-foot Thermo 1300 Series cabinet can provide an excellent combination of performance, familiarity, and value.

The key qualification is the application.

A standard Type A2 replacement should not automatically be substituted for an externally exhausted Forma 1184 without first evaluating why the legacy cabinet was exhausted and what materials are currently handled inside it.

Baker SterilGARD SG404: Strong 4-Foot Alternative

The Baker SterilGARD SG404 is another strong replacement option for laboratories using a Forma 1184 primarily for conventional biological applications.

The SG404 is a modern 4-foot Class II Type A2 biological safety cabinet designed to provide personnel, product, and environmental protection.

Baker's SterilGARD platform incorporates energy-efficient blower technology, contemporary airflow monitoring, LED lighting, an ergonomic work area, and a stainless-steel interior designed for demanding laboratory use.

For laboratories that do not need to remain with Thermo equipment, the SG404 provides an attractive combination of durability, efficiency, serviceability, and proven biological safety cabinet design.

American Instrument Exchange regularly supplies professionally refurbished Baker SterilGARD cabinets with new HEPA filters unless otherwise specified.

As with the Thermo 1300 Series, the SG404 should be selected only after confirming that a Type A2 cabinet is appropriate for the laboratory's current procedures and exhaust requirements.

What If You Still Need an Externally Exhausted BSC?

If your Forma 1184 is currently connected to building exhaust because of the materials or procedures performed inside it, do not simply disconnect the exhaust and install a standard recirculating BSC.

The appropriate replacement depends on the application.

A modern Type A2 cabinet connected through an appropriate canopy connection may be suitable for some applications.

Other procedures may require a different externally exhausted BSC configuration.

Chemical quantity, radionuclide use, microbiological procedures, building exhaust capacity, room design, and institutional safety requirements all need to be considered.

This is an area where the replacement should be selected based on a containment assessment rather than solely on price or cabinet dimensions.

American Instrument Exchange can help identify available equipment once the laboratory's required cabinet type has been established.

Key Thermo Forma 1184 Specifications

Specification Details
Manufacturer Forma Scientific / Thermo Forma
Model 1184
Cabinet Type Legacy Class II Type A/B3
Nominal Width 4 ft
Window Configuration Sliding
Operating Opening 10"
Exterior Dimensions Approximately 54"W × 64"H × 32.5"D
Interior Dimensions Approximately 49"W × 28.33"H × 22.25"D
Work Surface Type 304 stainless steel
Cabinet Construction Cold-rolled steel
Supply Filtration HEPA
Exhaust Filtration HEPA
Airflow Distribution Approximately 40% exhausted / 60% recirculated
Blower Motor 3/4 HP
Drain Pan Capacity Approximately 21.14 gallons
Original Design Standard NSF Standard 49
Exhaust Configuration Room exhaust or external exhaust depending on installation
Status Legacy / discontinued platform

Forma manufactured different electrical versions within this cabinet family. Electrical requirements and the specific configuration of an individual Forma 1184 should therefore be confirmed from the cabinet data plate before installation, relocation, or replacement planning.

Planning a Forma 1184 Replacement

Start replacement planning by documenting how the existing cabinet is currently installed.

Determine whether it is recirculating filtered exhaust into the laboratory or connected to building exhaust.

Then document the materials and procedures currently performed inside the cabinet.

Once the required cabinet type is established, physical compatibility can be considered.

The Forma 1184 cabinet itself is approximately 54 inches wide. A modern nominal 4-foot BSC may have somewhat different exterior dimensions, stand requirements, utility locations, and exhaust connections.

Doorways, ceiling height, stand height, electrical service, laboratory utilities, and delivery access should all be evaluated.

If an external exhaust system is involved, exhaust capacity and connection requirements must also be considered.

The replacement cabinet should be certified after installation in its final operating location and before being placed into routine laboratory service.

Refurbished Biosafety Cabinets from American Instrument Exchange

Replacing a legacy Forma 1184 does not necessarily require purchasing a new biosafety cabinet.

American Instrument Exchange stocks professionally refurbished Class II biosafety cabinets from Thermo Scientific, Baker, NuAire, Labconco, and other major manufacturers.

Refurbished BSCs are inspected and tested before shipment.

Unless otherwise specified, new HEPA filters are installed at our facility, and applicable cabinet systems are evaluated before the unit is offered for laboratory use.

Used and refurbished laboratory equipment supplied by American Instrument Exchange includes a 90-day warranty unless otherwise specified.

For a laboratory replacing an aging Forma 1184 used for conventional biological work, a refurbished newer-generation Thermo 1300 Series or Baker SterilGARD SG404 can provide a substantial modernization while avoiding the acquisition cost of comparable new equipment.

Frequently Asked Questions

Is the Thermo Forma 1184 discontinued?

Yes.

The Forma 1184 belongs to an older generation of Class II biological safety cabinets and should now be considered a legacy model.

Is the Forma 1184 a 4-foot biosafety cabinet?

Yes.

The model 1184 is a nominal 4-foot cabinet with a sliding front window.

Manufacturer documentation lists an exterior cabinet width of approximately 54 inches and an interior width of approximately 49 inches.

What does Class II Type A/B3 mean?

Type A/B3 is an older BSC classification.

The Forma 1184 was designed so that filtered exhaust could either return directly to the laboratory as a Type A configuration or be connected to an external building exhaust system for Type B3 operation.

Modern BSC terminology and installation practices have evolved, so a current replacement should be selected according to the laboratory's present application and containment requirements.

What is the operating sash height of the Forma 1184?

The manufacturer specifies a 10-inch work opening.

The cabinet was designed and tested around this operating opening, and the original manual warns that raising the window above the designated working position can weaken the protective air barrier.

Can a Thermo Forma 1184 still be certified?

Potentially, yes.

Age alone does not determine certification status.

The cabinet must be evaluated to determine whether HEPA filter integrity, airflow, sash operation, and other applicable performance requirements remain acceptable.

Why is my Forma 1184 failing certification?

Possible causes include HEPA filter loading or leakage, blower deterioration, incorrect airflow balance, sash-position problems, exhaust-system problems, damper adjustment, or other mechanical or airflow conditions.

Testing is required to identify the cause.

Is a Thermo Forma 1184 worth repairing?

It depends on the condition of the cabinet and the required repair.

An isolated HEPA, blower, sash, electrical, or airflow problem may justify repair when the rest of the cabinet remains sound.

Multiple major problems, obsolete components, repeated certification failures, or significant exhaust-system issues can make replacement more economical.

Can I replace a Forma 1184 with a Thermo 1300 Series BSC?

For many conventional biological applications, yes.

A 4-foot Thermo 1300 Series Class II Type A2 cabinet can provide a logical modern replacement.

However, if the existing Forma 1184 is externally exhausted because of chemical or radionuclide use, the application should be reviewed before changing cabinet type or exhaust configuration.

Is the Baker SG404 a good replacement for a Forma 1184?

Yes, when a modern 4-foot Class II Type A2 cabinet is appropriate for the application.

The Baker SG404 provides a strong alternative with modern blower technology, airflow monitoring, energy efficiency, ergonomics, and long-term serviceability.

Can I simply disconnect the external exhaust from my Forma 1184 and replace it with a Type A2 cabinet?

Not without evaluating the laboratory application.

If external exhaust is required because of the materials or procedures performed inside the cabinet, changing the exhaust arrangement without reviewing those requirements may result in an inappropriate replacement.

Consult the appropriate biosafety, EHS, industrial hygiene, or facility personnel before changing cabinet type.

Can volatile chemicals be used in a Forma 1184?

This depends on how the cabinet is configured and the specific application.

The original B3 configuration was intended to allow externally exhausted operation for applications involving limited chemical use in conjunction with biological work.

A modern replacement must be selected according to current safety requirements and the actual materials being handled.

Does a Forma 1184 need new HEPA filters just because it is old?

No.

HEPA filter replacement should be based on integrity, loading, resistance, airflow performance, and certification results rather than age alone.

Should a BSC be certified after it is moved?

Yes.

A biological safety cabinet should be field certified after installation or relocation before being placed into normal laboratory service.

Does American Instrument Exchange sell refurbished replacements for the Forma 1184?

Yes.

American Instrument Exchange supplies refurbished 4-foot Class II biosafety cabinets from Thermo Scientific, Baker, NuAire, Labconco, and other manufacturers.

Available inventory changes regularly.

Repair Your Thermo Forma 1184 or Plan a Modern Replacement

If your Thermo Forma 1184 is failing certification, experiencing airflow problems, developing blower or HEPA filter issues, having sash problems, or becoming increasingly difficult to maintain, American Instrument Exchange can help evaluate the next step.

If an economically reasonable repair can return the cabinet to reliable, certifiable operation, extending its service life may remain practical.

When repeated certification problems, obsolete components, major repairs, or declining reliability make continued service less attractive, American Instrument Exchange can help transition your laboratory to a newer biosafety cabinet.

For conventional biological applications, a 4-foot Thermo Scientific 1300 Series or Baker SterilGARD SG404 provides a logical modernization path.

If your Forma 1184 is externally exhausted or is used in procedures involving volatile chemicals or other materials that influenced the original Type B3 configuration, the containment and exhaust requirements should be evaluated before selecting a replacement.

Contact American Instrument Exchange to discuss Thermo Forma 1184 repair, Forma 1184 certification, Forma Type A/B3 replacement, legacy biosafety cabinet service, BSC HEPA filter replacement, Thermo 1300 Series upgrades, Baker SG404 replacements, externally exhausted BSCs, or refurbished 4-foot Class II biosafety cabinets.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.