4E’s USA 18L Contrast Media Wamer - NEW

Fully Tested & Warrantied*
Brand : 4E's USA
Product Code : SKU 0180 INC
Size: $964.95
Color: 01-10-2024

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

4E's USA 18L Contrast Media Warmer (Model CMW100101-LI)

Maintaining contrast media at the proper temperature can improve injection performance, reduce viscosity, and support a more comfortable patient experience during diagnostic imaging procedures. The 4E's USA 18L Contrast Media Warmer (Model CMW100101-LI) is a compact benchtop warming cabinet designed specifically for safely warming contrast media while also serving as a versatile laboratory incubator for a variety of heating applications. Unlike the refurbished laboratory equipment offered throughout much of the American Instrument Exchange inventory, this unit is brand new, providing healthcare facilities with modern warming technology backed by a full manufacturer's warranty.

Featuring an 18-liter chamber, PID digital temperature control, an insulated viewing window, and a secure digital keypad lock, the CMW100101-LI delivers accurate and consistent temperature regulation from ambient +5°C to 65°C. The stainless steel chamber, adjustable shelving, and built-in timer make it suitable not only for contrast media warming, but also for warming saline, laboratory reagents, culture media, and other temperature-sensitive materials used in medical and research laboratories.


4E's USA CMW100101-LI Contrast Media Warmer Key Features

  • Brand new unit

  • 18 L chamber capacity

  • Temperature range from ambient +5°C to 65°C

  • PID digital temperature controller

  • Temperature resolution of 0.1°C

  • Temperature accuracy of ±0.5°C

  • Temperature uniformity of ±2.0°C

  • Digital keypad door lock

  • Insulated glass viewing window

  • Stainless steel chamber and shelves

  • Six shelf positions with two shelves included

  • Built-in timer (0–9999 minutes)

  • Over-temperature protection and deviation alarms

  • Power failure safety protection


Designed for Contrast Media Warming and Laboratory Heating Applications

The 4E's USA CMW100101-LI was developed to provide reliable warming of contrast agents used during CT imaging, angiography, and other diagnostic procedures. Warming contrast media reduces viscosity, allowing smoother injection through power injectors and manual syringes while supporting more consistent delivery during imaging procedures. Precise PID temperature control maintains stable warming conditions without exposing contrast media to unnecessary temperature fluctuations.

Beyond medical imaging, the chamber serves as a compact laboratory incubator for warming reagents, microbiological samples, culture media, test kits, and other laboratory materials requiring controlled temperatures. The insulated viewing window allows users to monitor chamber contents without opening the door, helping maintain stable internal temperatures during operation.


Common Applications

The 4E's USA CMW100101-LI is commonly used for:

  • Contrast media warming

  • CT imaging departments

  • Radiology departments

  • Interventional radiology

  • Cardiac catheterization laboratories

  • Outpatient imaging centers

  • Saline warming

  • Laboratory reagent warming

  • Microbiology incubation

  • Sample drying

  • General laboratory heating

  • Clinical laboratory support

Healthcare facilities often pair contrast media warmers with laboratory refrigerators for reagent storage, freezers for long-term sample preservation, and centrifuges for specimen preparation in clinical laboratories.


Ideal Laboratory and Clinical Environments

The 4E's USA CMW100101-LI is well suited for hospitals, outpatient imaging centers, physician offices, radiology departments, catheterization laboratories, clinical laboratories, research facilities, and educational laboratories requiring dependable temperature-controlled warming in a compact footprint. Its benchtop design makes it an excellent solution for facilities where space is limited but precise temperature control remains essential.


Accurate Temperature Control in a Compact Footprint

At the heart of the CMW100101-LI is a PID digital temperature controller that continuously monitors chamber temperature using a Pt100 temperature sensor. This system maintains temperature accuracy of ±0.5°C with 0.1°C resolution, allowing users to confidently warm contrast media and other temperature-sensitive materials. Built-in safety features—including over-temperature protection, deviation alarms, and power failure protection—help safeguard valuable materials while supporting reliable day-to-day operation. The durable cold-rolled steel exterior and stainless steel interior are designed to withstand continuous clinical and laboratory use while remaining easy to clean and maintain.

Contrast Media Capacity and Typical Warming Applications

The 18-liter chamber of the 4E's USA CMW100101-LI provides a compact but flexible space for warming contrast media containers, saline, laboratory reagents, test kits, and other materials that require a stable thermal environment. Its stainless steel interior measures 260 × 260 × 260 mm, providing a cubic workspace that can be configured around containers of different sizes.

The chamber includes two adjustable shelves and offers six shelf positions, allowing healthcare and laboratory personnel to customize the interior layout for their specific workflow. Shelves can be repositioned or removed when taller containers require additional clearance. The insulated glass viewing window allows users to check chamber contents and controller status without opening the door and unnecessarily disrupting the internal temperature.

When the unit is used for contrast media, facilities should always follow the contrast manufacturer's instructions for use, including any stated warming temperature, allowable warming duration, container requirements, and handling procedures. Institutional radiology and medication-management policies should also be followed.


Energy Efficiency and Routine Operation

The 4E's USA CMW100101-LI uses natural convection to distribute heat within the chamber. Because the design does not depend on a mechanical circulation fan or refrigeration system, the unit offers quiet operation with relatively few moving components requiring maintenance.

Its insulated cabinet and PID controller work together to maintain the selected temperature while limiting unnecessary heater cycling. The unit has a rated power requirement of 0.18 kW, making it practical for continuous use in radiology departments, imaging centers, clinics, and laboratories.

Routine care should include keeping the chamber clean, avoiding blocked ventilation openings, inspecting the door seal and viewing window, and periodically verifying displayed temperature against a calibrated reference device. Facilities using the warmer for clinical materials should incorporate temperature verification and cleaning into their established quality-control procedures.


4E's USA CMW100101-LI 18L Contrast Media Warmer Key Specifications

Specification Details
Manufacturer 4E's USA
Model CMW100101-LI
Manufacturer Reference Model INC018
Equipment Type Locking Contrast Media Warmer and Compact Incubator
Product Condition Brand New
Chamber Capacity 18 L
Temperature Range Ambient +5°C to 65°C
Temperature Control PID Digital Controller
Temperature Resolution 0.1°C
Temperature Accuracy ±0.5°C
Temperature Uniformity ±2.0°C
Temperature Sensor Pt100
Convection Method Natural Convection
Timer Range 0–9,999 minutes
Interior Construction Stainless Steel
Exterior Construction Cold-Rolled, Epoxy-Painted Steel
Viewing Window Insulated Glass
Shelf Positions 6
Shelves Included 2
Interior Dimensions 260 × 260 × 260 mm (10.2" W × 10.2" D × 10.2" H)
Exterior Dimensions 410 × 410 × 620 mm (16.1" W × 16.1" D × 24.4" H)
Electrical Requirements 120 V, 60 Hz, 0.18 kW
Weight 27 kg (59.5 lb)
Safety Features Deviation alarm, power-failure safety, and overheat prevention
Manufacturer Warranty Two-Year All-Inclusive Warranty

Specifications are based on current manufacturer documentation and should be verified against the individual unit and product labeling before purchase or clinical use.


4E's USA CMW100101-LI Contrast Media Warmer Frequently Asked Questions

Is this contrast media warmer new or refurbished?

This 4E's USA CMW100101-LI is offered brand new, not refurbished. It includes the manufacturer's current warranty coverage rather than the American Instrument Exchange warranty generally supplied with refurbished laboratory equipment.

What is the chamber capacity?

The warmer has an 18-liter chamber with internal dimensions of approximately 10.2 inches wide, 10.2 inches deep, and 10.2 inches high. Two adjustable shelves are included, with six available shelf positions.

What temperature range does the CMW100101-LI provide?

The unit operates from 5°C above ambient temperature to 65°C. The appropriate setpoint depends on the material being warmed and the applicable manufacturer instructions, clinical procedures, or laboratory protocol.

Can this unit be used to warm contrast media?

Yes. The CMW100101-LI is marketed as a compact contrast media warmer and incubator. Radiology departments should follow the contrast media manufacturer's labeling and their institution's policies regarding warming temperature, storage duration, inspection, and handling.

Does the warmer have a locking door?

Yes. The CMW100101-LI is a locking model, helping facilities restrict access to contrast media, reagents, or other temperature-controlled materials stored inside the chamber.

Does it include adjustable shelves?

Yes. The unit includes two stainless steel shelves and provides six possible shelf positions. The shelves may be repositioned or removed to accommodate containers of different heights.

What safety alarms are included?

The control system includes a temperature-deviation alarm, overheat-prevention protection, and power-failure safety. Users should still perform routine temperature monitoring and follow any quality-control requirements established by their facility.

Does the CMW100101-LI use forced-air circulation?

No. It uses natural convection, which provides quiet operation without a chamber circulation fan. Users should avoid overcrowding the chamber so heat can circulate around the stored containers.

Can this unit be used for applications other than contrast media warming?

Yes. It may also be suitable for warming saline, reagents, test kits, biological materials, and other items compatible with its temperature range. Suitability should be determined according to the product manufacturer's instructions and the facility's laboratory or clinical procedures.

What warranty is included?

Because this unit is sold brand new, it includes a two-year all-inclusive manufacturer warranty from 4E's USA.

Why purchase a new 4E's USA contrast media warmer from American Instrument Exchange?

Purchasing the new 4E's USA CMW100101-LI from American Instrument Exchange gives healthcare and laboratory facilities access to a compact, locking warming cabinet with precise PID temperature control, stainless steel construction, adjustable shelving, built-in safety alarms, and a two-year manufacturer warranty. Its 18-liter capacity and space-saving countertop design make it a practical choice for radiology departments, imaging centers, clinics, and laboratories requiring dependable controlled-temperature warming.

Testing Procedures for Used and Refurbished Laboratory Incubators
Ensure Quality and Stability Before Use

Used and refurbished laboratory incubators from American Instrument Exchange are thoroughly tested to ensure optimal performance and temperature stability with laboratory safety standards. Each unit undergoes a detailed inspection and functionality assessment to meet the needs of research, clinical, and industrial labs.

Why Testing Used Laboratory Incubators Is Essential

Before a laboratory incubator is reintroduced into any work environment, it must be tested for:
• Temperature uniformity and accuracy
• Airflow and humidity control (if applicable)
• Door seal integrity and insulation effectiveness
• Electrical and safety system compliance

Comprehensive testing reduces the risk of culture loss, contamination, and equipment failure—especially critical in applications involving cell culture, microbiology, pharmaceutical research, and diagnostics.

Our multi-point testing protocol for used and refurbished incubators ensures reliability, safety, and performance across all models and brands.

Key Testing Procedures for Refurbished and Used Laboratory Incubators

1. Initial Visual Inspection
• Check for cosmetic damage, corrosion, and wear to exterior surfaces, door hinges, and gasket seals
• Inspect power cord, wiring, and display panel for any defects or signs of tampering
• Confirm that shelves, chamber components, and internal fixtures are present and undamaged

2. Functional Testing
• Power on the incubator and verify all display indicators and alarms function correctly
• Test door latch and seal mechanisms for proper closure and insulation
• Run basic temperature cycles to ensure the unit maintains stability over time

3. Temperature Accuracy and Uniformity Tests
• Test internal sensors and controllers using temperature probes
• Measure temperature consistency at multiple chamber locations over several hours
• Confirm that programmable temperature settings respond accurately

4. Airflow and Humidity Control (if applicable)
• Test internal fan operation and airflow distribution
• For humidified incubators, inspect and test humidity reservoirs, sensors, and control systems
• Check for condensation buildup and confirm environmental stability

5. Electrical Safety and Compliance Checks
• Ensure all electrical components are properly grounded
• Perform insulation resistance and leakage current tests
• Verify compliance with current electrical safety standards for laboratory equipment

6. Final Quality Assurance Checklist
• Perform full cycle testing at various temperature setpoints
• Document performance benchmarks and results

All refurbished incubators from American Instrument Exchange are backed by our commitment to quality and precision. With our strict testing procedures, you can rely on your incubator to deliver dependable results from day one.

Repair and Refurbishment Protocol for Used Laboratory Incubators
Performance and Quality from American Instrument Exchange

At American Instrument Exchange, every used laboratory incubator we sell goes through a repair and refurbishment protocol. Whether it’s a standard, CO₂, or refrigerated incubator, our goal is to restore each unit to laboratory-level performance—ensuring temperature accuracy, environmental stability, and long-term reliability in your lab.

Why Choose a Refurbished Laboratory Incubator from American Instrument Exchange?

• Fully tested for performance and safety
• Backed by a warranty
• Cost-effective alternative to new equipment
• Environmentally sustainable through reuse and restoration
• Refurbished by expert technicians with decades of lab equipment experience

Step-by-Step Refurbishment Protocol

Every incubator at American Instrument Exchange follows this comprehensive, multi-stage process:

1. Initial Intake & Inspection
• Visual inspection for cosmetic wear, corrosion, dents, or broken components
• Mechanical assessment of door hinges, gaskets, seals, and chamber components
• Document any missing parts or issues requiring repair or replacement

2. Cleaning and Decontamination
• Thorough internal and external cleaning using non-abrasive solutions
• Decontamination/cleaning of surfaces to remove biological, chemical, or particulate residue
• Cleaning of removable parts (e.g., shelves, trays, etc.)

3. Mechanical and Electrical Repair
• Repair or replacement of worn mechanical components such as door latches, fans, hinges, and seals
• Evaluation and repair of control panels, switches, thermostats, and displays
• Inspection and testing of wiring, fuses, relays, and power supplies

4. Environmental Control System Assessment
• For CO₂ incubators: CO₂ sensors, regulators, and gas delivery systems are tested
• For refrigerated incubators: compressors, condensers, and cooling systems are evaluated for performance and leaks
• Fan motors and airflow systems are tested to ensure uniform environmental conditions

5. Temperature and Sensor Testing
• All temperature sensors and controllers are tested using thermometers/probes
• Uniformity and accuracy tested at multiple chamber locations
• For humidified or CO₂ incubators, humidity and CO₂ stability are verified

6. Safety System Testing
• Test of over-temperature protection systems and alarms
• Evaluation of door sensors, safety interlocks, and power failure recovery

7. Final Quality Control and Documentation
• Full performance test run over 24 hours
• Validation of setpoints for temperature, CO₂ (if applicable), and humidity (if applicable)
• Final inspection and cleaning before packaging
• Complete service report

Trust the Experts at American Instrument Exchange

With over 50 years in the lab equipment industry, American Instrument Exchange is a trusted source for high-quality refurbished laboratory incubators. Our proven refurbishment protocol ensures every unit is reliable, accurate, and ready to meet the demands of your lab from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.