Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

4E's USA - Hematocrit Centrifuge - Brand New

Fully Tested & Warrantied*
Brand : 4E's USA
Product Code : SKU 0150A CENTRI
$2,050.00

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

4E's USA CFG400101 Hematocrit Centrifuge – Brand New

The 4E's USA CFG400101 Hematocrit Centrifuge is a high-speed benchtop centrifuge designed specifically for hematocrit determination, packed cell volume testing, micro blood separation, and other small-volume blood processing applications. Equipped with a 24-capillary-tube hematocrit rotor, this compact centrifuge reaches speeds up to 12,000 rpm and a maximum relative centrifugal force of 14,800 × g, providing the performance required for fast and efficient hematology workflows.

Available brand new from American Instrument Exchange, the CFG400101 combines dedicated hematocrit performance with modern microprocessor controls, a 5-inch HD touchscreen, programmable operating parameters, a brushless DC motor, and integrated safety features. It is an excellent choice for clinical laboratories, veterinary laboratories, research facilities, blood testing laboratories, educational institutions, and other facilities requiring reliable microhematocrit centrifugation.

Key Features

  • Brand-new 4E's USA hematocrit centrifuge

  • Model CFG400101

  • Maximum speed of 12,000 rpm

  • Maximum RCF of 14,800 × g

  • Includes 24-capillary-tube hematocrit rotor

  • Microhematocrit tube reader included

  • 5-inch HD touchscreen control interface

  • Microprocessor-controlled operation

  • Brushless DC motor for stable, low-noise performance

  • Speed accuracy of ±30 rpm

  • Programmable run times from 1 second to 99 minutes, 59 seconds

  • 10 selectable acceleration rates

  • 11 selectable deceleration rates

  • Multiple user-defined program options

  • Door lid interlock for operator safety

  • Compact benchtop design

  • Optional 12-capillary-tube rotor available

  • Two-year manufacturer warranty

Overview

The 4E's USA CFG400101 Hematocrit Centrifuge is purpose-built for laboratories that routinely process blood samples in capillary tubes. Unlike general-purpose clinical centrifuges designed around larger blood collection tubes, the CFG400101 provides the high rotational speed and dedicated capillary-tube rotor configuration needed for efficient microhematocrit testing.

The centrifuge reaches a maximum speed of 12,000 rpm with a maximum RCF of 14,800 × g when using the hematocrit rotor. Its standard rotor accommodates as many as 24 capillary tubes simultaneously, allowing laboratories to process multiple samples during a single run.

A supplied microhematocrit tube reader provides a convenient method for interpreting centrifuged capillary tubes following sample separation.

Modern electronic controls distinguish the CFG400101 from many traditional hematocrit centrifuges. A 5-inch HD touchscreen provides an intuitive interface for entering and viewing operating parameters, while microprocessor control helps provide consistent centrifugation from run to run.

Hematocrit and Packed Cell Volume Testing

Hematocrit testing measures the proportion of red blood cells, or erythrocytes, within a blood sample. After a capillary tube containing blood is centrifuged at high speed, the blood components separate according to density, allowing the packed red blood cell fraction to be evaluated.

The CFG400101 is designed specifically for this type of high-speed capillary tube separation. Its combination of 12,000 rpm maximum speed and 14,800 × g maximum RCF provides the centrifugal force needed to rapidly separate small-volume blood specimens.

The system can be used for determination of erythrocyte volume fractions in blood as well as separation of micro blood samples and solutions. It can also support workflows involving photometric assessment of bilirubin levels in neonatal blood specimens when used as part of an appropriate laboratory testing procedure.

Common Applications

The 4E's USA CFG400101 is well suited for hematocrit determination, packed cell volume testing, capillary blood sample processing, microhematocrit analysis, erythrocyte volume fraction determination, micro blood separation, veterinary hematology, clinical diagnostic workflows, neonatal blood sample preparation, and educational hematology applications.

Its dedicated rotor and relatively high centrifugal force make it particularly useful for facilities that routinely perform hematocrit testing rather than relying on a general-purpose centrifuge for every sample-processing procedure.

Ideal Laboratory Types

The CFG400101 is a practical choice for clinical laboratories, veterinary hospitals and diagnostic laboratories, physician office laboratories, hospitals, blood testing facilities, biomedical research laboratories, medical and veterinary schools, academic laboratories, and other facilities performing routine hematology testing.

Its compact benchtop dimensions also make it well suited for laboratories where workspace is limited or where a dedicated hematocrit centrifuge is preferred over tying up a larger multipurpose centrifuge.

24-Capillary-Tube Hematocrit Rotor

The CFG400101 comes equipped with a 24-capillary-tube hematocrit rotor, allowing laboratories to process as many as 24 capillary tubes during a single centrifugation cycle.

This capacity can be particularly valuable in clinical and veterinary environments where multiple blood specimens need to be processed efficiently.

A microhematocrit tube reader is also included, providing laboratories with the equipment needed to interpret packed cell volume after centrifugation.

For laboratories with different throughput requirements, a 12-capillary-tube rotor is available as an optional configuration.

Touchscreen Controls and Programmable Operation

A 5-inch HD touchscreen provides access to centrifuge operating parameters through an intuitive graphical interface. Compared with traditional centrifuges relying entirely on mechanical knobs or membrane keypads, the touchscreen allows users to quickly enter and review centrifugation settings.

The CFG400101 also provides multiple user-defined program options, allowing frequently used operating parameters to be stored for repeat laboratory procedures.

This can be particularly helpful in busy clinical environments where standardized centrifugation protocols are performed repeatedly throughout the day.

Acceleration and Deceleration Control

Different samples and laboratory protocols can benefit from controlled acceleration and braking characteristics.

The CFG400101 provides 10 acceleration rates and 11 deceleration rates, allowing the operator to customize how quickly the rotor reaches operating speed and how aggressively it slows at the end of the run.

This level of control provides greater flexibility than a basic hematocrit centrifuge with a single fixed acceleration and braking profile.

Brushless Motor and Low-Noise Operation

The CFG400101 uses a DC brushless motor designed for stable, reliable, and relatively quiet centrifuge operation.

Brushless motors eliminate the motor brushes found in conventional brushed designs, reducing a potential maintenance item while supporting consistent performance during routine laboratory use.

Operating noise is rated at 65 dB(A) or less, helping make the centrifuge suitable for busy laboratories where multiple instruments may be operating simultaneously.

Safety Features

High-speed centrifuges require effective safeguards to help prevent access to the rotor while it is operating.

The CFG400101 incorporates a door lid interlock as part of its safety system. The interlock helps prevent the centrifuge lid from being opened while the rotor is spinning, providing an important layer of operator protection during high-speed operation.

The centrifuge is designed to conform to applicable international safety standards and regulations for laboratory centrifugation equipment.

Key Specifications

Specification 4E's USA CFG400101
Manufacturer 4E's USA
Model CFG400101
Equipment Type Hematocrit Centrifuge
Condition Brand New
Installation Benchtop
Refrigerated No
Maximum Speed 12,000 rpm
Maximum RCF 14,800 × g
Standard Rotor 24-Capillary-Tube Hematocrit Rotor
Maximum Capacity 24 capillary tubes
Optional Rotor 12-Capillary-Tube Rotor
Speed Accuracy ±30 rpm
Timer Range 1 sec–99 min 59 sec
Display 5-inch HD touchscreen
Control Microprocessor
Motor DC brushless
Acceleration Profiles 10
Deceleration Profiles 11
Noise Level ≤65 dB(A)
Electrical AC 110V, 60 Hz / 220V, 50 Hz
Dimensions (W × D × H) 320 × 370 × 235 mm (12.6 × 14.6 × 9.3 in.)
Net Weight 11 kg (24.3 lb.)
Included Accessories 24-capillary-tube rotor and microhematocrit tube reader
Warranty Two-year manufacturer warranty

Choosing a Dedicated Hematocrit Centrifuge

Laboratories performing hematocrit testing regularly may benefit from using a dedicated hematocrit centrifuge rather than relying exclusively on a multipurpose clinical centrifuge.

Dedicated systems such as the CFG400101 are designed around the specific requirements of capillary tubes and microhematocrit testing. The 24-position rotor allows numerous capillary samples to be processed simultaneously, while the high-speed 12,000 rpm / 14,800 × g performance provides the centrifugal force required for efficient packed cell volume separation.

Using a dedicated hematocrit centrifuge can also keep larger clinical centrifuges available for serum tubes, plasma preparation, blood collection tubes, conical tubes, and other routine laboratory workflows.

Brand-New 4E's USA Centrifuges from American Instrument Exchange

American Instrument Exchange offers brand-new 4E's USA centrifuges alongside our extensive inventory of refurbished laboratory centrifuges from manufacturers including Thermo Scientific, Sorvall, Beckman Coulter, Eppendorf, and other leading laboratory equipment manufacturers.

The 4E's USA line provides laboratories with an attractive option when factory-new equipment, modern controls, warranty coverage, and cost-effective acquisition are priorities.

The CFG400101 is supplied brand new with a two-year manufacturer warranty, making it particularly attractive for startup laboratories, expanding clinical facilities, educational institutions, veterinary laboratories, and established laboratories replacing older hematocrit centrifuges.

Related Laboratory Equipment

Laboratories performing hematology and blood-processing workflows can also explore American Instrument Exchange's selection of clinical centrifuges, benchtop centrifuges, microcentrifuges, and refrigerated centrifuges.

American Instrument Exchange also offers additional brand-new centrifuges from 4E's USA for laboratories requiring different rotor capacities, speeds, temperature control, or sample-processing capabilities.

For complete laboratory buildouts, AIE supplies a broad range of additional new and refurbished laboratory equipment, including biosafety cabinets, laboratory refrigerators, laboratory freezers, incubators, balances, mixers, shakers, and other benchtop laboratory instruments.

Frequently Asked Questions

What is the 4E's USA CFG400101 Hematocrit Centrifuge used for?

The CFG400101 is designed primarily for hematocrit determination, packed cell volume testing, and separation of small-volume blood samples in capillary tubes. It can be used in clinical, veterinary, research, and educational hematology applications.

What is the maximum speed of the CFG400101?

The hematocrit rotor has a maximum operating speed of 12,000 rpm.

What is the maximum RCF?

The CFG400101 produces a maximum relative centrifugal force of 14,800 × g with its hematocrit rotor.

How many capillary tubes can the centrifuge hold?

The included hematocrit rotor accommodates up to 24 capillary tubes per run.

Does the centrifuge include a microhematocrit reader?

Yes. The CFG400101 comes with both a 24-capillary-tube hematocrit rotor and a microhematocrit tube reader.

Does the CFG400101 have a touchscreen?

Yes. The centrifuge features a 5-inch HD touchscreen for setting and viewing centrifugation parameters.

Can acceleration and braking be adjusted?

Yes. The CFG400101 provides 10 acceleration rates and 11 deceleration rates, allowing users to customize rotor acceleration and braking characteristics.

Is the 4E's USA hematocrit centrifuge refrigerated?

No. The CFG400101 is a non-refrigerated benchtop hematocrit centrifuge intended primarily for rapid capillary blood separation and related applications.

Is this centrifuge new or refurbished?

This CFG400101 is brand new, not refurbished or previously used.

What warranty is included?

Brand-new 4E's USA equipment is supplied with a two-year manufacturer warranty.

Testing Procedures for Used and Refurbished Laboratory Centrifuges

Ensure Quality, Accuracy, and Compliance Before Deployment

Used and refurbished laboratory centrifuges from American Instrument Exchange undergo testing procedures to ensure they meet the performance, safety, and compliance standards required in modern laboratories.

Why Testing Used Laboratory Centrifuges Is Essential

Before a centrifuge is reintroduced into a lab environment, it must be tested for:

  • Mechanical integrity
  • Rotor balance and speed accuracy
  • Safety system functionality
  • Electrical compliance

Proper testing helps extend equipment lifespan, reduce downtime, and ensure safety in high-stakes lab environments such as clinical diagnostics, biotechnology, and research applications.

Our structured testing protocol for used and refurbished centrifuges ensures equipment safety, accuracy, and longevity.

Key Testing Procedures for Refurbished and Used Centrifuges

1. Initial Visual Inspection

  • Check for signs of wear, corrosion, or damage to housing, lid, and control panels
  • Inspect power cords, plugs, and connectors for fraying or exposed wiring
  • Confirm that the rotor and accessories are compatible and undamaged

2. Functional Testing

  • Power up the centrifuge and confirm successful boot-up of digital or analog displays
  • Test lid lock and emergency stop mechanisms
  • Run initial cycles at various speeds to check for abnormal noise or vibration

3. Rotor and Speed Verification

  • Test all programmable speed settings to confirm consistent acceleration and deceleration
  • Monitor temperature, vibration, and RPM consistency throughout the cycle
  • Balance testing ensures smooth operation and prevents wear on internal components

4. Electrical Safety and Grounding Tests

  • Verify that all electrical components are properly grounded and shielded

5. Temperature Control (if applicable)

  • For refrigerated centrifuges, test cooling function to ensure temperature stability within set ranges
  • Check refrigerant levels and inspect for compressor noise or failure

6. Final Quality Assurance Checklist

  • Conduct a full run-through using the user interface
  • Document all test results

Repair and Refurbishment Protocol for Used Laboratory Centrifuges

Certified Quality from American Instrument Exchange

At American Instrument Exchange, we follow a meticulous repair and refurbishment protocol to ensure that every used laboratory centrifuge we sell. We strive for reliable performance and long-term durability—providing labs with exceptional value on high-quality pre-owned centrifuges.

Why Choose a Refurbished Centrifuge from American Instrument Exchange?

  • Fully tested
  • Backed by warranty and performance guarantee
  • Cost-effective alternative to new lab equipment
  • Environmentally responsible through equipment reuse
  • Supported by expert technicians with decades of experience

Step-by-Step Refurbishment Protocol

Every used centrifuge at American Instrument Exchange goes through the following comprehensive repair and refurbishment process:

1. Initial Intake & Inspection

  • Our technicians perform a complete visual and mechanical inspection
  • Evaluation of hinges, seals, gaskets, and electrical components
  • Any physical damage, missing parts, or wear is documented for repair

2. Cleaning and decontamination

  • Full internal and external cleaning using non-abrasive, disinfectant-safe products
  • Biological or chemical residue is decontaminated/cleaned

3. Mechanical & Electrical Repairs

  • Damaged or worn parts (e.g., drive motors, lid latches, rotor buckets) are replaced or repaired
  • Electrical components, sensors, and fuses are tested and replaced as needed
  • Wiring is inspected for integrity and safety per industry standards

4. Rotor & Accessory Evaluation

  • All rotors, buckets, and adapters are inspected for cracks, corrosion, and balance
  • Non-conforming components are replaced with OEM or equivalent alternatives

5. Performance Testing

  • Rotor speed (RPM), acceleration, and deceleration are verified
  • Refrigerated centrifuges undergo temperature stability testing across set ranges

6. Safety System Verification

  • Lid lock and interlock systems are tested for proper function
  • Emergency stop and imbalance detection systems are verified
  • Electrical safety and grounding tests are conducted

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the industry, American Instrument Exchange is a trusted name for refurbished lab equipment. Our centrifuge refurbishment protocol reflects our commitment to quality, safety, and customer satisfaction.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.