The AirClean Systems AC23238 is a compact, vented rotary evaporator enclosure designed to provide localized containment for solvent vapors and chemical fumes generated during laboratory evaporation procedures. Available used and refurbished from American Instrument Exchange, this AirClean 200 Series workstation offers a dedicated enclosure for rotary evaporators and related laboratory equipment without occupying the space required for a conventional full-size chemical fume hood.
Designed for compatibility with rotary evaporators from manufacturers such as Büchi and Heidolph, the AC23238 features a two-tier front access system, removable front panel, and 4-inch exhaust duct collar. Its compact 32" W × 24" D × 42" H configuration makes it particularly attractive for laboratories requiring chemical vapor containment in areas with limited bench space.
Unlike ductless AirClean enclosures that use activated carbon filtration to recirculate air, this AC23238 is configured for connection to an external exhaust system. The blower motor is not included and must be supplied separately as part of an appropriately designed laboratory ventilation system.
Used and refurbished AirClean Systems AC23238 rotary evaporator enclosure
AirClean 200 Series laboratory workstation
Compact 32-inch-wide enclosure
Designed for rotary evaporator containment
Suitable for selected Büchi and Heidolph rotary evaporator configurations
Exterior dimensions of 32" W × 24" D × 42" H
4-inch exhaust duct collar
Two-tier front access door system
Lower access doors measuring 16.25 inches high
Upper access doors measuring 10.25 inches high
Removable front panel secured with four thumb screws
Convenient access for rotary evaporator installation and maintenance
Designed for connection to an external laboratory exhaust system
External blower motor required and not included
Refurbished and inspected by American Instrument Exchange
90-day warranty included
The AirClean Systems AC23238 provides a specialized containment workspace for laboratories using rotary evaporators and other equipment involved in solvent evaporation.
Rotary evaporators are widely used in chemistry, pharmaceutical research, environmental testing, and analytical laboratories to concentrate samples and recover solvents under reduced pressure.
Although these instruments typically incorporate condensers and receiving flasks to collect evaporated solvents, chemical vapors may still escape during operation, flask changes, equipment adjustments, and solvent collection.
The AC23238 provides an enclosure around the rotary evaporator, allowing an appropriately designed exhaust system to capture and remove these vapors from the immediate laboratory environment.
Its relatively compact footprint makes it useful for laboratories that want a dedicated rotary evaporation workstation while preserving larger chemical fume hoods for other procedures.
One of the distinguishing characteristics of the AirClean 200 Series rotary evaporator enclosure is its equipment-focused design.
The AC23238 is intended to accommodate rotary evaporators, including selected instruments manufactured by Büchi and Heidolph.
Its interior configuration provides space for the major components of a typical rotary evaporator assembly, including the rotating evaporation flask, condenser, receiving flask, and associated support equipment.
The enclosure's front access arrangement allows operators to interact with the instrument while keeping much of the equipment surrounded by the containment structure.
Because rotary evaporators vary in height, condenser orientation, flask capacity, and accessory configuration, laboratories should verify the actual dimensions of their instrument before purchasing the enclosure.
Compatibility with a particular Büchi or Heidolph model should not be assumed solely from the manufacturer name.
The AC23238 incorporates a distinctive two-tier front door arrangement designed to provide convenient access to enclosed equipment.
The lower doors measure approximately 16.25 inches high, while the upper doors measure approximately 10.25 inches high.
This configuration allows operators to access different portions of a rotary evaporator assembly without necessarily removing the entire front panel.
For example, the lower section can facilitate access to evaporation flasks, collection vessels, and lower equipment components, while the upper section provides access to condensers, connections, and other elevated parts of the apparatus.
This design can be especially convenient for procedures requiring frequent sample changes or adjustments to the rotary evaporator.
During operation, the doors should be positioned according to the airflow requirements established for the complete exhaust system.
In addition to its two-tier doors, the AirClean AC23238 features a removable front panel secured with four thumb screws.
This allows the entire front section to be removed when greater access is required for installing, positioning, or servicing laboratory equipment.
The removable panel is particularly useful when loading a rotary evaporator with a tall condenser, complex glassware arrangement, or other components that may be difficult to maneuver through the normal door openings.
It can also simplify cleaning and maintenance by providing more direct access to the enclosure interior.
The front panel must be properly reinstalled before the enclosure is used for procedures requiring chemical vapor containment.
The AirClean AC23238 is equipped with a 4-inch exhaust duct collar for connection to an external laboratory ventilation system.
When paired with an appropriately sized blower and ductwork, the enclosure can draw room air inward through the access openings and carry chemical vapors toward the exhaust connection.
This arrangement helps prevent solvent vapors generated during rotary evaporation from accumulating around the operator or spreading into the surrounding laboratory.
Because the AC23238 is configured for external exhaust, its operation does not depend on recirculating chemical vapors through an activated carbon filtration system.
However, the enclosure does not include a blower motor. A suitable exhaust source must be selected and installed before the unit is placed into service.
Blower selection should account for the required containment airflow, duct length, elbows, static pressure, and the chemical hazards associated with the intended procedures.
Measuring 32 inches wide, 24 inches deep, and 42 inches high, the AC23238 provides a compact alternative to larger laboratory fume hoods.
The relatively narrow width makes it suitable for laboratories where bench space is limited or where a dedicated rotary evaporation workstation must be added to an existing equipment layout.
Its 42-inch height provides additional vertical space compared with many general-purpose benchtop enclosures.
The compact configuration may also help laboratories organize rotary evaporation procedures in a designated area rather than moving equipment between different fume hoods.
Before installation, the supporting surface should be evaluated for the combined weight of the enclosure, rotary evaporator, glassware, and accessories.
The AirClean AC23238 is intended primarily for rotary evaporation and related solvent-handling procedures.
Typical applications include solvent removal from chemical samples, sample concentration, organic synthesis preparation, pharmaceutical research, extraction solvent recovery, chromatography sample preparation, and environmental sample processing.
The enclosure may also be appropriate for certain other laboratory instruments that require localized chemical vapor exhaust, provided the equipment fits within the enclosure and the ventilation system is suitable for the intended hazards.
The compatibility of the enclosure with any procedure should be evaluated based on the chemicals involved, quantities handled, and required containment performance.
The AC23238 is particularly well suited for organic chemistry laboratories, pharmaceutical research and development facilities, analytical chemistry laboratories, biotechnology research facilities, environmental testing laboratories, university chemistry departments, and industrial quality control laboratories.
It may be especially useful for facilities that perform rotary evaporation regularly and want to dedicate a smaller enclosure to those procedures rather than occupying a larger conventional chemical fume hood.
| Specification | Details |
|---|---|
| Manufacturer | AirClean Systems |
| Product Line | 200 Series |
| Model | AC23238 |
| AIE Product Code | 1696E HOOD |
| Product Type | Vented Rotary Evaporator Enclosure |
| Primary Application | Rotary evaporator containment |
| Nominal Width | 32 inches |
| Exterior Dimensions | 32" W × 24" D × 42" H |
| Exhaust Duct Collar | 4 inches |
| Ventilation Configuration | External exhaust |
| Front Access | Two-tier door system |
| Lower Door Height | 16.25 inches |
| Upper Door Height | 10.25 inches |
| Removable Front Panel | Yes |
| Front Panel Fasteners | Four thumb screws |
| Rotary Evaporator Compatibility | Selected Büchi and Heidolph models; verify fit |
| Blower Motor | Not included |
| External Exhaust System | Required |
| Built-In Carbon Filtration | Not specified for this vented configuration |
| Interior Dimensions | Confirm for individual unit |
| Electrical Requirements | Dependent on installed accessories |
| Condition | Used and reconditioned |
| Warranty | 90 days |
Proper installation is essential for safe operation of the AC23238.
The enclosure must be connected to a suitable external exhaust system using its 4-inch duct collar. The selected blower should provide adequate airflow through the enclosure while accounting for the resistance of the complete ductwork system.
AIE does not include a blower motor with this unit. Laboratories should coordinate blower selection and ventilation design with an experienced laboratory HVAC contractor or qualified ventilation specialist.
The exhaust system must also be suitable for the chemical vapors generated during the intended rotary evaporation procedures.
After installation, airflow and containment performance should be verified with the enclosure configured for normal operation.
The unit should not be used for hazardous solvent procedures until the complete ventilation system has been evaluated.
The AirClean AC23238 and a conventional chemical fume hood both provide a means of capturing chemical vapors when connected to appropriate exhaust systems, but they are designed for different laboratory workflows.
A conventional chemical fume hood provides a larger, general-purpose workspace for chemical preparation, reactions, dispensing, and other laboratory procedures.
The AC23238 is a specialized equipment enclosure designed primarily for rotary evaporators.
Its two-tier access doors and removable front panel are particularly useful for positioning and operating evaporation equipment.
For laboratories that routinely use rotary evaporators, a dedicated enclosure can help preserve conventional fume hood space for other procedures while providing an equipment-focused workstation.
AirClean Systems also manufactures ductless rotary evaporator enclosures that use activated carbon filtration and integrated blowers to return treated air to the laboratory.
The AC23238 offered by American Instrument Exchange is configured differently. It includes a 4-inch exhaust duct collar and requires an external blower.
This distinction is important when planning installation.
A ductless enclosure may be appropriate for selected chemical applications when the installed filtration media is compatible with the solvents being handled.
An externally exhausted enclosure such as the AC23238 can be preferable where building ventilation is available or where the chemical hazards make recirculating filtration unsuitable.
The correct system should be selected based on the laboratory's chemical inventory, ventilation infrastructure, and operating requirements.
This AirClean Systems AC23238 is used and reconditioned by American Instrument Exchange.
Our technicians inspect the enclosure's structural condition, access doors, removable front panel, exhaust connection, and other applicable components. The unit is cleaned and prepared for shipment following the refurbishment process.
Because the AC23238 requires an external exhaust source, final airflow performance cannot be established independently of the installed ventilation system.
Appropriate airflow and containment testing should therefore be completed after the enclosure is connected to the laboratory's selected blower and ductwork.
The compact dimensions of the AC23238 make it a practical option for laboratories with limited space.
Before purchase, laboratories should verify available bench space, overhead clearance, rotary evaporator dimensions, and access to the required exhaust connection.
The enclosure should be installed on a stable supporting surface capable of accommodating the weight of the enclosure and the equipment placed inside it.
American Instrument Exchange can provide additional information and photographs of the individual unit to help customers evaluate compatibility with their laboratory equipment.
American Instrument Exchange offers a broad selection of refurbished chemical fume hoods and laboratory ventilation enclosures for facilities requiring chemical vapor containment.
For complete evaporation workflows, AIE also supplies rotary evaporators and related evaporation equipment, vacuum pumps, and recirculating chillers and circulators.
Selecting compatible equipment can help laboratories establish efficient solvent evaporation and recovery workstations.
Purchasing a refurbished AirClean Systems AC23238 provides laboratories with a cost-effective way to add dedicated rotary evaporator containment without purchasing an entirely new equipment enclosure.
Its compact 32-inch width, two-tier access doors, removable front panel, and external exhaust configuration make it particularly attractive for laboratories performing frequent solvent evaporation procedures.
American Instrument Exchange specializes in used and refurbished laboratory equipment, helping research, pharmaceutical, industrial, and educational laboratories obtain equipment at a lower cost than purchasing new.
This AirClean AC23238 includes a 90-day warranty from American Instrument Exchange.
The AC23238 is a vented laboratory enclosure designed primarily for rotary evaporators. It provides a contained workspace that can be connected to an external exhaust system to capture solvent vapors generated during evaporation procedures.
No. The AC23238 offered by American Instrument Exchange does not include a blower motor. A compatible external exhaust blower is required.
No. This particular AC23238 is configured with a 4-inch exhaust duct collar for connection to an external ventilation system. It should not be confused with AirClean's ductless rotary evaporator enclosures.
The enclosure measures 32 inches wide, 24 inches deep, and 42 inches high externally.
The AirClean 200 Series enclosure is designed for compatibility with selected Büchi rotary evaporators. Buyers should verify the dimensions of their specific instrument, condenser, and accessories before purchase.
Yes, the enclosure family is intended for use with selected Heidolph rotary evaporators. Compatibility with an individual model depends on the equipment's dimensions and configuration.
The AC23238 incorporates separate upper and lower door sections. The lower doors are approximately 16.25 inches high, while the upper doors are approximately 10.25 inches high, providing access to different portions of the enclosed equipment.
Yes. The front panel is secured with four thumb screws and can be removed to facilitate equipment installation, cleaning, and maintenance.
The enclosure includes a 4-inch exhaust duct collar. The complete exhaust system must be designed to provide appropriate airflow and containment performance.
Yes, provided the external exhaust system is suitable for the chemicals being handled and the complete installation provides adequate containment. Chemical compatibility and ventilation requirements should be evaluated before use.
Yes. Because the enclosure depends on an external blower and ductwork, airflow and containment performance should be verified after installation before the unit is used for hazardous chemical procedures.
Yes. The AirClean AC23238 includes a 90-day warranty from American Instrument Exchange.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.