Binder C150-UL CO₂ Incubator

Maintaining a clean, stable incubation environment is essential for successful mammalian cell culture, tissue engineering, and pharmaceutical research. The Binder C150-UL CO₂ Incubator is engineered to deliver precise temperature regulation, accurate carbon dioxide control, and outstanding contamination prevention through a combination of dry-heat sterilization technology, infrared CO₂ sensing, and a seamless stainless steel chamber. Featuring a 5.5 cubic foot (150 L) chamber, an air-jacket heating system, a 180°C overnight hot-air sterilization cycle, and a drift-free infrared CO₂ sensor, the C150-UL provides dependable environmental control for research and production laboratories alike.

Designed for laboratories that prioritize reproducibility and simplified maintenance, the Binder C150-UL combines rapid environmental recovery with an interior specifically engineered for easy cleaning. Its weldless, deep-drawn stainless steel chamber eliminates seams and inaccessible corners where contaminants can accumulate, while the tightly sealing inner glass door and integrated shelf support system further contribute to a clean incubation environment. Purchasing a refurbished Binder C150-UL CO₂ Incubator from American Instrument Exchange provides laboratories with premium cell culture performance at a substantial savings compared to purchasing new equipment.


Binder C150-UL CO₂ Incubator Key Features

  • 150 L (5.5 cu. ft.) chamber capacity

  • Temperature range: Ambient +7°C to 50°C

  • Air-jacket heating system

  • CO₂ control range: 0–20%

  • Drift-free infrared (IR) CO₂ sensor

  • 180°C overnight hot-air sterilization cycle

  • Weldless deep-drawn stainless steel chamber

  • Integrated shelf support system

  • Tightly sealing inner glass door

  • Three perforated stainless steel shelves

  • Microprocessor temperature and CO₂ controller

  • LED digital display

  • Automatic diagnostic system

  • Alarm relay contact for remote monitoring

  • 115V electrical operation

  • 90-day warranty from American Instrument Exchange


Designed for Reliable Mammalian Cell Culture

The Binder C150-UL is designed to provide a contamination-resistant environment for sensitive mammalian cell culture applications. Its air-jacket heating system delivers stable temperature control while allowing rapid recovery after routine door openings, helping maintain consistent environmental conditions throughout the workday. The drift-free infrared CO₂ sensor provides highly accurate carbon dioxide measurement without the calibration drift commonly associated with older sensing technologies, allowing researchers to maintain stable culture conditions over extended incubation periods.

One of the defining features of the C150-UL is its 180°C hot-air sterilization cycle, which allows the entire chamber to be decontaminated overnight without chemical disinfectants or extensive manual cleaning. Combined with the seamless stainless steel interior, integrated shelf supports, and smooth interior surfaces, the sterilization cycle helps reduce contamination risks while simplifying routine maintenance for busy cell culture laboratories.


Common Applications

The Binder C150-UL CO₂ Incubator is commonly used for:

  • Mammalian cell culture

  • Stem cell research

  • Primary cell culture

  • Hybridoma production

  • CHO and HEK293 cell cultivation

  • Monoclonal antibody development

  • Cancer biology

  • Tissue engineering

  • Regenerative medicine

  • Pharmaceutical research

  • Cell therapy research

  • Biotechnology process development

The Binder C150-UL is frequently incorporated into complete cell culture workflows. Many laboratories pair this incubator with biosafety cabinets for sterile media preparation and cell handling before incubation. Laboratory refrigerators are commonly used to store cell culture media, sera, antibiotics, and growth supplements, while laboratory freezers preserve working cell banks and biological reagents. Ultralow temperature freezers provide long-term storage for master cell lines and valuable research samples, and centrifuges are routinely used for harvesting cells, washing cultures, and preparing samples for downstream analysis.


Ideal Laboratory Environments

The Binder C150-UL is an excellent choice for biotechnology companies, pharmaceutical manufacturers, university research laboratories, hospital research facilities, regenerative medicine programs, clinical laboratories, contract research organizations, and cell therapy development laboratories. Its combination of infrared CO₂ sensing, dry-heat sterilization, and contamination-resistant chamber design makes it particularly well suited for laboratories where protecting valuable cell cultures is a daily priority.


Why Choose the Binder C150-UL CO₂ Incubator?

The Binder C150-UL combines precise environmental control with a chamber specifically engineered to simplify cleaning and reduce contamination risks. Its seamless stainless steel interior, drift-free infrared CO₂ sensing, and automated 180°C dry-heat sterilization cycle provide laboratories with dependable performance while minimizing maintenance requirements and supporting consistent experimental results.

Whether supporting routine mammalian cell culture, stem cell research, tissue engineering, or pharmaceutical development, the Binder C150-UL delivers the environmental stability, contamination control, and operational reliability required for modern cell culture laboratories.

Binder C150-UL CO₂ Incubator Performance and Environmental Stability

The Binder C150-UL CO₂ Incubator is designed to provide the stable environmental conditions required for consistent mammalian cell culture and other sensitive biological applications. Its air-jacket heating system delivers excellent temperature uniformity throughout the chamber while allowing rapid recovery following routine door openings. The drift-free infrared (IR) CO₂ sensor continuously monitors carbon dioxide concentration with high accuracy, helping maintain optimal culture conditions without the frequent recalibration often associated with thermal conductivity sensors.

A defining feature of the C150-UL is its integrated 180°C hot-air sterilization cycle, which allows the entire chamber to be decontaminated overnight without the use of chemical disinfectants. The seamless deep-drawn stainless steel interior, integrated shelf support system, and tightly sealing inner glass door further reduce contamination risks by eliminating difficult-to-clean crevices and minimizing unnecessary air exchange. Together, these features provide a clean, stable incubation environment that supports reliable long-term cell culture performance.


Binder C150-UL Typical Cell Types and Laboratory Applications

The Binder C150-UL supports a wide variety of mammalian cell culture applications in biotechnology, pharmaceutical, clinical, and academic laboratories. Typical cell types include CHO cells, HEK293 cells, Vero cells, BHK cells, fibroblasts, epithelial cells, stem cells, primary mammalian cells, hybridomas, and numerous other anchorage-dependent or suspension cell lines requiring controlled CO₂ incubation.

Researchers commonly utilize the C150-UL for monoclonal antibody development, recombinant protein expression, cancer biology, regenerative medicine, tissue engineering, vaccine research, cell therapy development, pharmaceutical discovery, toxicology studies, microbiological research, and routine expansion of laboratory cell cultures.


Binder C150-UL CO₂ Incubator Specifications

Specification Details
Manufacturer Binder
Model C150-UL
Equipment Type CO₂ Incubator
Chamber Capacity 150 L (5.5 cu. ft.)
Temperature Range Ambient +7°C to 50°C
CO₂ Control Range 0–20%
Heating System Air Jacket
CO₂ Sensor Drift-Free Infrared (IR)
Sterilization Cycle 180°C Hot-Air Sterilization
Chamber Construction Deep-Drawn Stainless Steel
Interior Door Tightly Sealing Safety Glass
Shelves Three Perforated Stainless Steel Shelves
Controller Microprocessor Digital Controller
Display LED Digital Display
Alarm System Visual, Audible, and Remote Alarm Relay
Electrical Requirements 115V

Specifications are compiled from manufacturer literature and American Instrument Exchange product information. Specifications may vary depending on production year and installed options. Please verify chamber dimensions, electrical requirements, and included accessories prior to purchase.


Binder C150-UL CO₂ Incubator Frequently Asked Questions

What makes the Binder C150-UL different from many other CO₂ incubators?

The C150-UL combines an air-jacket heating system, a drift-free infrared CO₂ sensor, and an automated 180°C dry-heat sterilization cycle with a seamless stainless steel chamber, providing excellent contamination control and reliable environmental stability for sensitive cell culture work.

Why is an infrared CO₂ sensor beneficial?

Infrared sensors provide highly accurate carbon dioxide measurement with minimal long-term drift. This reduces the need for frequent recalibration while helping maintain stable culture conditions throughout extended incubation periods.

What is the purpose of the 180°C sterilization cycle?

The integrated hot-air sterilization cycle heats the chamber to 180°C, effectively reducing biological contamination without requiring chemical disinfectants. This simplifies routine maintenance and helps protect valuable cell cultures.

What types of cell cultures can be grown in the C150-UL?

The incubator is suitable for a wide variety of mammalian cell lines, including CHO, HEK293, Vero, BHK, hybridomas, stem cells, fibroblasts, primary cells, and numerous other research and production cell cultures.

Which laboratories commonly use the Binder C150-UL?

The C150-UL is widely used in biotechnology companies, pharmaceutical manufacturers, academic research laboratories, clinical research facilities, regenerative medicine programs, cell therapy laboratories, and contract research organizations.

Is this incubator suitable for long-term cell culture studies?

Yes. Its stable temperature regulation, precise CO₂ control, contamination-resistant chamber design, and automated sterilization cycle make it well suited for both routine culture work and long-term biological research.

Why purchase a refurbished Binder C150-UL CO₂ Incubator from American Instrument Exchange?

A refurbished Binder C150-UL CO₂ Incubator from American Instrument Exchange provides laboratories with dependable cell culture performance at a substantial savings compared to purchasing new equipment. Featuring a 150-liter chamber, air-jacket heating, a drift-free infrared CO₂ sensor, an automated 180°C dry-heat sterilization cycle, and a seamless stainless steel interior, the C150-UL is an excellent choice for biotechnology, pharmaceutical, academic, and clinical laboratories. Every unit is thoroughly inspected and tested prior to shipment and includes a 90-day warranty for added confidence.

CLICK HERE to see the Binder C150-UL on our YouTube channel

Testing Procedures for Used and Refurbished Laboratory Incubators
Ensure Quality and Stability Before Use

Used and refurbished laboratory incubators from American Instrument Exchange are thoroughly tested to ensure optimal performance and temperature stability with laboratory safety standards. Each unit undergoes a detailed inspection and functionality assessment to meet the needs of research, clinical, and industrial labs.

Why Testing Used Laboratory Incubators Is Essential

Before a laboratory incubator is reintroduced into any work environment, it must be tested for:
• Temperature uniformity and accuracy
• Airflow and humidity control (if applicable)
• Door seal integrity and insulation effectiveness
• Electrical and safety system compliance

Comprehensive testing reduces the risk of culture loss, contamination, and equipment failure—especially critical in applications involving cell culture, microbiology, pharmaceutical research, and diagnostics.

Our multi-point testing protocol for used and refurbished incubators ensures reliability, safety, and performance across all models and brands.

Key Testing Procedures for Refurbished and Used Laboratory Incubators

1. Initial Visual Inspection
• Check for cosmetic damage, corrosion, and wear to exterior surfaces, door hinges, and gasket seals
• Inspect power cord, wiring, and display panel for any defects or signs of tampering
• Confirm that shelves, chamber components, and internal fixtures are present and undamaged

2. Functional Testing
• Power on the incubator and verify all display indicators and alarms function correctly
• Test door latch and seal mechanisms for proper closure and insulation
• Run basic temperature cycles to ensure the unit maintains stability over time

3. Temperature Accuracy and Uniformity Tests
• Test internal sensors and controllers using temperature probes
• Measure temperature consistency at multiple chamber locations over several hours
• Confirm that programmable temperature settings respond accurately

4. Airflow and Humidity Control (if applicable)
• Test internal fan operation and airflow distribution
• For humidified incubators, inspect and test humidity reservoirs, sensors, and control systems
• Check for condensation buildup and confirm environmental stability

5. Electrical Safety and Compliance Checks
• Ensure all electrical components are properly grounded
• Perform insulation resistance and leakage current tests
• Verify compliance with current electrical safety standards for laboratory equipment

6. Final Quality Assurance Checklist
• Perform full cycle testing at various temperature setpoints
• Document performance benchmarks and results

All refurbished incubators from American Instrument Exchange are backed by our commitment to quality and precision. With our strict testing procedures, you can rely on your incubator to deliver dependable results from day one.

Repair and Refurbishment Protocol for Used Laboratory Incubators
Performance and Quality from American Instrument Exchange

At American Instrument Exchange, every used laboratory incubator we sell goes through a repair and refurbishment protocol. Whether it’s a standard, CO₂, or refrigerated incubator, our goal is to restore each unit to laboratory-level performance—ensuring temperature accuracy, environmental stability, and long-term reliability in your lab.

Why Choose a Refurbished Laboratory Incubator from American Instrument Exchange?

• Fully tested for performance and safety
• Backed by a warranty
• Cost-effective alternative to new equipment
• Environmentally sustainable through reuse and restoration
• Refurbished by expert technicians with decades of lab equipment experience

Step-by-Step Refurbishment Protocol

Every incubator at American Instrument Exchange follows this comprehensive, multi-stage process:

1. Initial Intake & Inspection
• Visual inspection for cosmetic wear, corrosion, dents, or broken components
• Mechanical assessment of door hinges, gaskets, seals, and chamber components
• Document any missing parts or issues requiring repair or replacement

2. Cleaning and Decontamination
• Thorough internal and external cleaning using non-abrasive solutions
• Decontamination/cleaning of surfaces to remove biological, chemical, or particulate residue
• Cleaning of removable parts (e.g., shelves, trays, etc.)

3. Mechanical and Electrical Repair
• Repair or replacement of worn mechanical components such as door latches, fans, hinges, and seals
• Evaluation and repair of control panels, switches, thermostats, and displays
• Inspection and testing of wiring, fuses, relays, and power supplies

4. Environmental Control System Assessment
• For CO₂ incubators: CO₂ sensors, regulators, and gas delivery systems are tested
• For refrigerated incubators: compressors, condensers, and cooling systems are evaluated for performance and leaks
• Fan motors and airflow systems are tested to ensure uniform environmental conditions

5. Temperature and Sensor Testing
• All temperature sensors and controllers are tested using thermometers/probes
• Uniformity and accuracy tested at multiple chamber locations
• For humidified or CO₂ incubators, humidity and CO₂ stability are verified

6. Safety System Testing
• Test of over-temperature protection systems and alarms
• Evaluation of door sensors, safety interlocks, and power failure recovery

7. Final Quality Control and Documentation
• Full performance test run over 24 hours
• Validation of setpoints for temperature, CO₂ (if applicable), and humidity (if applicable)
• Final inspection and cleaning before packaging
• Complete service report

Trust the Experts at American Instrument Exchange

With over 50 years in the lab equipment industry, American Instrument Exchange is a trusted source for high-quality refurbished laboratory incubators. Our proven refurbishment protocol ensures every unit is reliable, accurate, and ready to meet the demands of your lab from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.