All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Caron 6026 Reach-In CO₂ Incubator with Condensate Recirculating System CRSY102-1
Large-scale cell culture laboratories require more than simply increased incubation capacity—they also need dependable environmental control that minimizes maintenance while supporting continuous operation. The Caron 6026 Reach-In CO₂ Incubator combines a 25 cubic foot (708 L) chamber, precise temperature regulation, infrared CO₂ sensing, active humidity control, and the CRSY102-1 Condensate Recirculating System to create a highly efficient incubation platform for biotechnology, pharmaceutical, and research laboratories. Designed for high-volume mammalian cell culture, the 6026 delivers stable incubation conditions while simplifying water management for facilities with demanding production schedules.
One of the defining features of this system is the included CRSY102-1 Condensate Recirculating System. Rather than relying on an external deionized water supply, the CRSY102-1 filters incoming water, captures condensate produced during normal incubator operation, and recirculates it back into the chamber's active humidity system. This approach helps reduce water consumption, minimizes maintenance, and makes installation easier in laboratories that lack dedicated DI water systems or floor drains. Combined with a heated triple-pane glass door, infrared CO₂ sensor, RTD temperature sensing, adjustable sliding shelves, and active humidity control to 95% RH, the Caron 6026 remains an excellent solution for large-capacity cell culture workflows.
Caron 6026 Key Features
25 cu. ft. (708 L) chamber capacity
Temperature range: 5°C to 60°C
Active humidity control to 95% RH
Infrared (IR) CO₂ sensor
CO₂ control range: 0%–20%
Included CRSY102-1 Condensate Recirculating System
Heated triple-pane glass door
RTD temperature sensor
Adjustable sliding stainless steel shelves
Interior electrical outlet and utility access ports
Air intake filtration system
Locking digital control panel with audible alarms
115V electrical operation
90-day warranty from American Instrument Exchange
Designed for High-Capacity Cell Culture with Simplified Water Management
The Caron 6026 is engineered for laboratories performing high-volume mammalian cell culture where environmental consistency and operational efficiency are equally important. Its reach-in configuration provides substantially more usable incubation space than conventional benchtop CO₂ incubators, allowing researchers to incubate large numbers of flasks, culture plates, and production vessels within a single chamber. Direct heat temperature regulation, infrared CO₂ monitoring, and active humidity control work together to maintain the stable conditions required for sensitive cell culture applications.
The included CRSY102-1 Condensate Recirculating System distinguishes this incubator from many other large-capacity models. The external unit continuously filters incoming water, captures condensate produced inside the incubator, and recycles it through the humidity system. This closed-loop approach helps maintain a reliable supply of clean water while reducing waste and simplifying installation in laboratories that do not have dedicated deionized water plumbing. The result is consistent humidity control with reduced operator intervention and lower long-term maintenance requirements.
Common Applications
The Caron 6026 is commonly used for:
Large-scale mammalian cell culture
Monoclonal antibody production
Vaccine research and manufacturing
Cell therapy development
Regenerative medicine
Recombinant protein expression
Bioprocess development
Pharmaceutical research
Long-term cell expansion
Translational medicine
Contract research and manufacturing
High-throughput biotechnology workflows
The 6026 is frequently installed alongside biosafety cabinets used for aseptic cell culture, while laboratory refrigerators store media and reagents. Laboratory freezers and ultralow-temperature freezers preserve master and working cell banks, and centrifuges support routine harvesting, washing, and downstream processing of cultured cells.
Ideal Laboratory Environments
The Caron 6026 is an excellent choice for biotechnology companies, pharmaceutical manufacturers, contract research organizations, university core laboratories, vaccine development facilities, regenerative medicine programs, and industrial research laboratories requiring high-capacity incubation with dependable humidity management. The integrated condensate recirculating system is particularly valuable for facilities seeking to simplify water supply requirements while maintaining consistent environmental performance.
Why Choose the Caron 6026?
The Caron 6026 combines large-capacity incubation with an innovative water management system that helps simplify installation and reduce maintenance. Its actively controlled humidity, infrared CO₂ sensing, heated triple-pane observation door, and integrated CRSY102-1 Condensate Recirculating System provide dependable environmental control for laboratories performing demanding cell culture workflows.
Whether supporting pilot production, bioprocess development, vaccine research, or routine expansion of mammalian cell cultures, the Caron 6026 delivers the environmental stability, capacity, and operational efficiency required for modern life science laboratories.
Performance and Environmental Stability
The Caron 6026 Reach-In CO₂ Incubator is engineered to provide stable environmental conditions throughout its large 25 cubic foot chamber, making it well suited for laboratories performing high-volume mammalian cell culture and production-scale research. Direct heat temperature regulation and forced-air circulation promote excellent temperature uniformity across the chamber, helping ensure that culture vessels on every shelf experience consistent incubation conditions. Rapid environmental recovery following routine door openings minimizes fluctuations that could affect sensitive cell cultures or long-term research projects.
An integrated non-dispersive infrared (IR) CO₂ sensor continuously monitors chamber carbon dioxide concentration, providing accurate long-term control with minimal calibration drift. Because infrared sensing is unaffected by elevated humidity, the system maintains dependable CO₂ regulation even during prolonged high-humidity operation. Stable carbon dioxide levels help maintain media pH and create the consistent environmental conditions required for reproducible mammalian cell culture.
The Caron 6026 also incorporates active humidity control capable of maintaining relative humidity levels approaching 95% without relying on a conventional standing water pan inside the chamber. Instead, humidity is generated as needed, reducing standing water that can contribute to contamination or increase routine cleaning requirements.
A distinguishing feature of this particular system is the included CRSY102-1 Condensate Recirculating System. During normal incubator operation, condensate is collected, filtered, and recirculated back into the humidity generation system, reducing overall water consumption while minimizing dependence on dedicated deionized water plumbing. For laboratories without readily available DI water infrastructure or floor drains, this closed-loop design simplifies installation and helps maintain a consistent supply of clean water for humidity generation with reduced operator intervention.
Typical Cell Types and Laboratory Applications
The Caron 6026 supports a wide variety of mammalian cell culture applications performed in biotechnology, pharmaceutical, and translational research laboratories. Common cell types include CHO cells, HEK293 cells, Vero cells, hybridomas, fibroblasts, epithelial cells, mesenchymal stem cells, induced pluripotent stem cells (iPSCs), primary mammalian cells, insect cells, and numerous adherent and suspension cultures requiring tightly controlled incubation environments.
Typical laboratory applications include monoclonal antibody production, recombinant protein expression, vaccine development, regenerative medicine, cell therapy manufacturing, tissue engineering, process development, scale-up studies, pharmaceutical research, toxicology testing, gene therapy research, and routine expansion of production cell cultures. The spacious reach-in chamber accommodates large quantities of flasks, roller bottles, cell factories, and other culture vessels used in high-throughput laboratory workflows.
Caron 6026 Reach-In CO₂ Incubator Specifications
Specification
Details
Manufacturer
Caron
Model
6026
Equipment Type
Reach-In CO₂ Incubator
Chamber Capacity
25 cu. ft. (Approximately 708 L)
Exterior Dimensions
Approximately 38" W × 39" D × 72" H
Interior Dimensions
Approximately 32" W × 30" D × 46" H
Weight
Approximately 600 lbs
Temperature Range
5°C to 60°C
CO₂ Control Range
0%–20%
Humidity Range
Up to 95% RH
CO₂ Sensor
Infrared (IR)
Temperature Sensor
RTD
Heating System
Direct Heat
Humidity System
Active Water Injection
Water Management
CRSY102-1 Condensate Recirculating System
Door Design
Heated Triple-Pane Glass
Shelves
Adjustable Sliding Stainless Steel Shelves
Electrical Requirements
115V, 60 Hz
Specifications are compiled from manufacturer literature and American Instrument Exchange product information. Specifications may vary depending on production year and installed options. Please verify chamber dimensions, electrical requirements, gas requirements, shelf configuration, and included accessories prior to purchase.
Frequently Asked Questions
What is the purpose of the CRSY102-1 Condensate Recirculating System?
The CRSY102-1 captures condensate generated during normal incubator operation, filters it, and recirculates it back into the humidity system. This closed-loop design helps reduce water consumption, simplifies humidity management, and minimizes dependence on an external deionized water supply.
Does the condensate recirculating system eliminate the need for deionized water?
The CRSY102-1 is designed to simplify water management by filtering incoming water and recycling condensate, making it an excellent solution for many laboratories that do not have dedicated deionized water infrastructure. Users should consult the manufacturer's recommendations for installation and water quality requirements specific to their application.
Why does the Caron 6026 use an infrared CO₂ sensor?
An infrared CO₂ sensor provides highly accurate carbon dioxide measurement with excellent long-term stability and is not affected by the high humidity levels maintained inside the chamber. This helps maintain consistent culture conditions with reduced calibration requirements.
What types of laboratories benefit most from this incubator?
The Caron 6026 is commonly used by biotechnology companies, pharmaceutical manufacturers, contract research organizations, university core laboratories, regenerative medicine facilities, vaccine development laboratories, and industrial research groups performing large-scale mammalian cell culture.
What types of culture vessels can be accommodated?
The spacious reach-in chamber is designed to accommodate large numbers of tissue culture flasks, roller bottles, multiwell plates, cell factories, and other production-scale culture vessels, depending on the installed shelving configuration.
Is the Caron 6026 appropriate for scale-up and pilot production?
Yes. Its large chamber capacity, active humidity control, infrared CO₂ monitoring, and condensate recirculating system make it well suited for laboratories transitioning from research-scale experiments to pilot production and other high-throughput cell culture operations.
Why purchase a refurbished Caron 6026 from American Instrument Exchange?
A refurbished Caron 6026 Reach-In CO₂ Incubator from American Instrument Exchange provides laboratories with production-scale incubation capacity while simplifying humidity and water management through the included CRSY102-1 Condensate Recirculating System. Featuring a 25 cubic foot chamber, infrared CO₂ sensing, active humidity control, direct heat temperature regulation, and a heated triple-pane glass door, the Caron 6026 is an excellent choice for biotechnology, pharmaceutical manufacturing, vaccine development, regenerative medicine, and other high-volume cell culture applications. Every unit is thoroughly inspected and tested prior to shipment and includes a 90-day warranty from American Instrument Exchange.
Click here to see a video of this environmental chamber on our YouTube channel.
Testing Procedures for Used and Refurbished Laboratory Incubators Ensure Quality and Stability Before Use
Used and refurbished laboratory incubators from American Instrument Exchange are thoroughly tested to ensure optimal performance and temperature stability with laboratory safety standards. Each unit undergoes a detailed inspection and functionality assessment to meet the needs of research, clinical, and industrial labs.
Why Testing Used Laboratory Incubators Is Essential
Before a laboratory incubator is reintroduced into any work environment, it must be tested for:
• Temperature uniformity and accuracy
• Airflow and humidity control (if applicable)
• Door seal integrity and insulation effectiveness
• Electrical and safety system compliance
Comprehensive testing reduces the risk of culture loss, contamination, and equipment failure—especially critical in applications involving cell culture, microbiology, pharmaceutical research, and diagnostics.
Our multi-point testing protocol for used and refurbished incubators ensures reliability, safety, and performance across all models and brands.
Key Testing Procedures for Refurbished and Used Laboratory Incubators
1. Initial Visual Inspection
• Check for cosmetic damage, corrosion, and wear to exterior surfaces, door hinges, and gasket seals
• Inspect power cord, wiring, and display panel for any defects or signs of tampering
• Confirm that shelves, chamber components, and internal fixtures are present and undamaged
2. Functional Testing
• Power on the incubator and verify all display indicators and alarms function correctly
• Test door latch and seal mechanisms for proper closure and insulation
• Run basic temperature cycles to ensure the unit maintains stability over time
3. Temperature Accuracy and Uniformity Tests
• Test internal sensors and controllers using temperature probes
• Measure temperature consistency at multiple chamber locations over several hours
• Confirm that programmable temperature settings respond accurately
4. Airflow and Humidity Control (if applicable)
• Test internal fan operation and airflow distribution
• For humidified incubators, inspect and test humidity reservoirs, sensors, and control systems
• Check for condensation buildup and confirm environmental stability
5. Electrical Safety and Compliance Checks
• Ensure all electrical components are properly grounded
• Perform insulation resistance and leakage current tests
• Verify compliance with current electrical safety standards for laboratory equipment
6. Final Quality Assurance Checklist
• Perform full cycle testing at various temperature setpoints
• Document performance benchmarks and results
All refurbished incubators from American Instrument Exchange are backed by our commitment to quality and precision. With our strict testing procedures, you can rely on your incubator to deliver dependable results from day one.
Repair and Refurbishment Protocol for Used Laboratory Incubators Performance and Quality from American Instrument Exchange
At American Instrument Exchange, every used laboratory incubator we sell goes through a repair and refurbishment protocol. Whether it’s a standard, CO₂, or refrigerated incubator, our goal is to restore each unit to laboratory-level performance—ensuring temperature accuracy, environmental stability, and long-term reliability in your lab.
Why Choose a Refurbished Laboratory Incubator from American Instrument Exchange?
• Fully tested for performance and safety
• Backed by a warranty
• Cost-effective alternative to new equipment
• Environmentally sustainable through reuse and restoration
• Refurbished by expert technicians with decades of lab equipment experience
Step-by-Step Refurbishment Protocol
Every incubator at American Instrument Exchange follows this comprehensive, multi-stage process:
1. Initial Intake & Inspection
• Visual inspection for cosmetic wear, corrosion, dents, or broken components
• Mechanical assessment of door hinges, gaskets, seals, and chamber components
• Document any missing parts or issues requiring repair or replacement
2. Cleaning and Decontamination
• Thorough internal and external cleaning using non-abrasive solutions
• Decontamination/cleaning of surfaces to remove biological, chemical, or particulate residue
• Cleaning of removable parts (e.g., shelves, trays, etc.)
3. Mechanical and Electrical Repair
• Repair or replacement of worn mechanical components such as door latches, fans, hinges, and seals
• Evaluation and repair of control panels, switches, thermostats, and displays
• Inspection and testing of wiring, fuses, relays, and power supplies
4. Environmental Control System Assessment
• For CO₂ incubators: CO₂ sensors, regulators, and gas delivery systems are tested
• For refrigerated incubators: compressors, condensers, and cooling systems are evaluated for performance and leaks
• Fan motors and airflow systems are tested to ensure uniform environmental conditions
5. Temperature and Sensor Testing
• All temperature sensors and controllers are tested using thermometers/probes
• Uniformity and accuracy tested at multiple chamber locations
• For humidified or CO₂ incubators, humidity and CO₂ stability are verified
6. Safety System Testing
• Test of over-temperature protection systems and alarms
• Evaluation of door sensors, safety interlocks, and power failure recovery
7. Final Quality Control and Documentation
• Full performance test run over 24 hours
• Validation of setpoints for temperature, CO₂ (if applicable), and humidity (if applicable)
• Final inspection and cleaning before packaging
• Complete service report
Trust the Experts at American Instrument Exchange
With over 50 years in the lab equipment industry, American Instrument Exchange is a trusted source for high-quality refurbished laboratory incubators. Our proven refurbishment protocol ensures every unit is reliable, accurate, and ready to meet the demands of your lab from day one.
Warranty Information
All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full. American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,
Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”
Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.
Return & Cancellation Policy
American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted.
Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.
Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.
Ongoing and Extended Support Options
American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.
For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.
For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.
Yes, all equipment from American Instrument Exchange comes with a warranty. Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
How do you test and recondition the equipment?
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality. We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
How do products ship from American Instrument Exchange?
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
Return and order cancellation policy
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Are discounts available for educational or non-profit institutions, or for bulk purchases?
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
How does your price matching policy work?
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Can I see the equipment in person before committing to a purchase?
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Can I ship products that I purchased elsewhere to American Instrument for repair?
Yes – please see our repair services page for more information.