The Electro-Tech Systems Model 518 Controlled Environment Chamber is a precision laboratory glove box designed for testing, handling, fabrication, and storage of materials under controlled temperature and relative humidity conditions. Manufactured by Electro-Tech Systems (ETS), the Model 518 combines an airtight acrylic enclosure with automatic temperature and humidity regulation, allowing researchers to perform sensitive procedures without exposing materials to uncontrolled laboratory conditions.
The ETS Model 518 provides a relative humidity control range of 5% to 98% RH at laboratory ambient temperature, with manufacturer-specified stability of approximately ±0.5% RH. Temperature can be controlled from 0°C to 50°C, with stability of approximately ±0.5°C under appropriate operating conditions.
The chamber uses separate automatic control systems for temperature and humidity. Ultrasonic humidification increases moisture, desiccant-based dehumidification removes moisture, an electric heater raises temperature, and a liquid carbon dioxide cooling system provides cooling when properly connected to an external CO₂ supply.
Two glove ports allow users to manipulate materials within the controlled environment. The approximately 13-cubic-foot working chamber provides substantial space for laboratory instruments, test specimens, electronics, packaging materials, and other humidity- or temperature-sensitive products.
Unlike hypoxia chambers designed to regulate oxygen and CO₂ for biological research, the Model 518 is primarily intended for environmental testing and material conditioning. Its combination of humidity and temperature control makes it especially useful for electronics research, electrostatic testing, materials science, pharmaceutical research, packaging evaluation, and quality-control applications.
This Electro-Tech Systems Model 518 is used and refurbished by American Instrument Exchange. The unit is inspected, tested, and cleaned before shipment and includes a 90-day warranty.
Electro-Tech Systems Model 518 Controlled Environment Chamber
Integrated temperature and relative humidity control
Approximately 13 cubic feet of usable chamber space
Relative humidity range of 5–98% RH at laboratory ambient temperature
Humidity stability of approximately ±0.5% RH
Temperature range of 0–50°C
Temperature stability of approximately ±0.5°C
Two glove ports for material handling
Clear and white acrylic chamber construction
ETS Model 514 automatic humidity controller
ETS Model 513A automatic temperature controller
Ultrasonic humidification system
Desiccant-based dehumidification
Electric heating system
Liquid CO₂ cooling capability
Internal circulation fan
Integrated chamber lighting
Side access door
Cable and tubing access
Used and refurbished by American Instrument Exchange
90-day warranty included
Many laboratory and industrial processes are sensitive to changes in temperature and relative humidity.
Moisture can affect electrical resistance, electrostatic charge accumulation, material dimensions, chemical stability, surface properties, packaging performance, and other characteristics.
Temperature changes can also influence material behavior, instrument performance, and experimental results.
The Electro-Tech Systems Model 518 provides a controlled environment in which these variables can be adjusted and maintained independently.
Its airtight acrylic enclosure reduces the influence of surrounding room conditions, while integrated controllers automatically respond to changes in the chamber environment.
Two glove ports allow operators to manipulate samples and equipment without routinely opening the chamber and disturbing the selected environmental conditions.
The ETS Model 518 is suitable for humidity-sensitive materials testing, electrostatic research, electronic component evaluation, printed circuit board research, packaging studies, pharmaceutical material conditioning, polymer testing, adhesive research, coating evaluation, moisture-sensitive sample handling, environmental quality control, and other applications requiring controlled temperature and humidity.
It may also support laboratory procedures in which samples must be manipulated under defined environmental conditions rather than simply stored in a temperature- or humidity-controlled cabinet.
The Model 518 is well suited to electronics laboratories, materials science facilities, pharmaceutical research laboratories, industrial quality-control departments, packaging development laboratories, polymer research groups, academic research institutions, semiconductor research facilities, electrostatics laboratories, and manufacturing R&D departments.
Its combination of controlled humidity, temperature regulation, and glove-port access makes it particularly useful for applications where maintaining environmental conditions during handling is important.
| Specification | Details |
|---|---|
| Manufacturer | Electro-Tech Systems (ETS) |
| Model | 518 |
| AIE Inventory Number | 2722 |
| Equipment Type | Temperature and Humidity Controlled Glove Box |
| Chamber Capacity | Approximately 13 cu ft |
| Exterior Dimensions | 47"W × 25.5"D × 22"H |
| Interior Dimensions | Approximately 39"W × 22.5"D × 21–22"H |
| Relative Humidity Range | 5–98% RH at Laboratory Ambient |
| Humidity Stability | Approximately ±0.5% RH |
| Temperature Range | 0–50°C |
| Temperature Stability | Approximately ±0.5°C |
| Humidity Controller | ETS Model 514 |
| Temperature Controller | ETS Model 513A |
| Humidification | Ultrasonic |
| Dehumidification | Desiccant System |
| Heating | 500 W Electric Heater |
| Cooling | Liquid CO₂ Expansion System |
| Chamber Construction | Clear and White Acrylic |
| Glove Access | Two Ports |
| Internal Circulation | Fan |
| Chamber Lighting | 15 W Fluorescent |
| Access | Side Door and Cable/Tubing Port |
| Condition | Used / Refurbished |
| Warranty | 90 Days from American Instrument Exchange |
The Model 518 is designed to maintain controlled humidity across a broad range.
Electro-Tech Systems specifies a relative humidity range of 5% to 98% at laboratory ambient temperature, with stability of approximately ±0.5% RH under appropriate conditions.
This allows researchers to evaluate materials under both dry and high-humidity environments.
Humidity can influence electrical properties, dimensional stability, moisture absorption, surface conductivity, adhesive performance, and many other material characteristics.
The ability to establish a selected humidity level helps researchers reduce environmental variability between tests.
The Model 518 incorporates an ETS Model 514 automatic humidity controller.
The controller measures chamber humidity and compares the actual reading with the selected setpoint.
Its display provides humidity readings and setpoint information, while the control system activates humidification or dehumidification equipment as required.
The controller offers 0.1% RH display resolution, allowing precise adjustment and observation of chamber conditions.
When humidity must be increased, the Model 518 uses an ultrasonic humidification system.
Ultrasonic humidification generates a fine water mist that is introduced into the chamber environment.
The automatic humidity controller activates the humidifier when relative humidity falls below the selected level.
This provides a means of establishing elevated humidity conditions for materials testing and environmental conditioning.
Water quality and humidifier maintenance should follow the manufacturer's recommendations to minimize mineral deposits and contamination.
Low-humidity operation is achieved using a desiccant-based dehumidification system.
Desiccant removes moisture from the chamber atmosphere, allowing the system to establish dry conditions without relying solely on continuous gas purging.
This is useful for moisture-sensitive electronics, polymers, packaging materials, and other specimens requiring reduced relative humidity.
Desiccant condition and regeneration or replacement requirements should be evaluated as part of routine maintenance.
The Model 518 also incorporates an independent temperature-control system.
Electro-Tech Systems specifies a temperature range of 0°C to 50°C, with stability of approximately ±0.5°C under appropriate conditions.
Temperature regulation allows researchers to evaluate material behavior under controlled thermal conditions while simultaneously monitoring relative humidity.
The actual achievable temperature range depends on ambient laboratory conditions and the installed heating and cooling systems.
The ETS Model 513A provides automatic temperature regulation.
It compares measured chamber temperature with the selected setpoint and activates heating or cooling as required.
This independent control arrangement allows temperature to be managed separately from relative humidity, although the two environmental variables remain physically interdependent.
The Model 518 uses a 500-watt electric heater to raise chamber temperature.
The heating element is positioned behind an internal aluminum panel.
A thermal safety switch provides protection against excessive temperature.
This system allows the chamber to maintain elevated temperatures for appropriate materials testing and conditioning procedures.
One of the more unusual features of the Model 518 is its cooling system.
Rather than relying on a conventional compressor-based refrigeration circuit, the chamber uses expansion of liquid carbon dioxide to produce cooling.
The original manufacturer documentation specifies a liquid CO₂ cylinder equipped with a dip tube and an appropriate high-pressure connection.
When cooling is required, the controller opens a solenoid valve, allowing liquid CO₂ to expand into gas and produce a cooling effect.
The liquid CO₂ supply and associated equipment must be properly installed and handled according to applicable gas-safety procedures.
Temperature and relative humidity are closely related.
Changing chamber temperature affects relative humidity even when the amount of water vapor present remains unchanged.
The Model 518 therefore uses separate control systems that work together to maintain selected conditions.
However, the full advertised temperature and humidity ranges should not be interpreted as simultaneously achievable at every combination.
Electric heating can reduce relative humidity, while the dry CO₂ gas used for cooling can limit the maximum humidity achievable during cooling.
Researchers should verify that their intended temperature and humidity combination is within the practical operating capabilities of the chamber.
Low-humidity environments can be useful when studying moisture-sensitive electronic components, materials, packaging, and other products.
Reducing humidity may help researchers investigate drying behavior, material stability, electrical insulation properties, and other environmental responses.
The Model 518 provides a controlled alternative to exposing samples to changing laboratory humidity.
Elevated humidity conditions can be useful for evaluating moisture absorption, packaging performance, polymer behavior, coating properties, and other characteristics.
The ultrasonic humidification system allows the chamber to establish high relative humidity conditions when operating temperature and other environmental factors permit.
The chamber should not automatically be considered a validated environmental aging or accelerated-life-testing system without application-specific qualification.
Humidity can strongly influence electrostatic charge accumulation and dissipation.
Dry environments may allow static charge to persist, while higher humidity can change the surface conductivity of many materials.
The Model 518 allows researchers to investigate these effects under controlled environmental conditions.
The standard acrylic enclosure should not automatically be assumed to have specialized electrostatic-dissipative construction unless that option is verified.
Electronic components and assemblies may be sensitive to humidity and temperature during handling, fabrication, testing, or storage.
The Model 518 provides a controlled environment for investigating these effects.
Potential applications include component evaluation, insulation testing, electrostatic behavior, materials characterization, and research involving moisture-sensitive assemblies.
Its glove-port access allows operators to handle specimens without immediately exposing them to uncontrolled room conditions.
Packaging materials can absorb moisture, change dimensions, or exhibit different barrier and mechanical properties under changing environmental conditions.
The Model 518 allows researchers to condition specimens at selected temperature and humidity levels.
This can support packaging development, polymer research, adhesive evaluation, and quality-control investigations.
Moisture and temperature can affect pharmaceutical powders, excipients, packaging materials, and other research samples.
The Model 518 may support appropriate non-hazardous material conditioning and testing under controlled environmental conditions.
However, the chamber should not be assumed to provide hazardous-powder containment, chemical-vapor protection, or pharmaceutical aseptic conditions.
Applications involving hazardous materials require separate evaluation of the chamber's suitability.
Two glove ports allow operators to manipulate materials inside the chamber without opening the side access door.
This is especially useful when the environmental conditions must remain stable during a procedure.
Opening a chamber door can introduce room air and disrupt humidity and temperature.
Glove-port access reduces the need for these interruptions.
The condition and inclusion of gloves and sleeves should be confirmed for the individual AIE unit.
The Model 518 provides approximately 13 cubic feet of usable working space.
The chamber is constructed from clear and white acrylic, allowing users to observe equipment and specimens during testing.
Its generous interior accommodates a range of instruments, test fixtures, sample holders, and other laboratory materials.
Equipment placement should preserve airflow and avoid obstructing the temperature and humidity sensors.
A side access door provides a convenient method for introducing or removing equipment and specimens.
This is useful when items are too large or awkward to transfer through the glove ports.
After opening the door, the chamber may require time to return to the selected temperature and humidity conditions.
The Model 518 includes an access opening for routing cables and tubing into the controlled environment.
This allows compatible instruments, sensors, and test equipment to operate inside the chamber while remaining connected to external equipment.
Connections should be properly sealed to minimize uncontrolled air exchange.
An internal circulation fan helps distribute conditioned air throughout the chamber.
Air movement promotes more consistent temperature and humidity conditions around specimens and instruments.
Large equipment or densely packed samples should be positioned to avoid unnecessary obstruction of circulation.
The Model 518 includes a 15-watt fluorescent chamber light.
Interior illumination improves visibility when handling samples or adjusting instruments through the glove ports.
The lighting system can be controlled independently from the environmental regulation functions.
A conventional glove box may provide only a physical barrier between materials and the surrounding room.
The ETS Model 518 adds automatic control of both temperature and relative humidity.
This makes it an environmental testing chamber rather than simply a sealed enclosure.
Its principal advantage is the ability to handle specimens while maintaining defined atmospheric moisture and temperature conditions.
A nitrogen dry box typically relies on dry gas purging to reduce oxygen and moisture.
The Model 518 instead uses automatic humidity regulation, including both humidification and dehumidification.
It can establish dry conditions or deliberately elevated humidity levels.
It is not primarily designed to maintain an inert atmosphere or precisely regulate oxygen concentration.
Hypoxia chambers such as the Coy and Plas-Labs systems are designed primarily to regulate oxygen concentration for biological research.
The ETS Model 518 is designed around temperature and humidity.
It should not be represented as an oxygen-controlled cell-culture workstation or a substitute for a tri-gas incubator.
A conventional environmental test chamber may provide temperature and humidity control but often requires opening a door to manipulate specimens.
The Model 518 adds glove-port access.
This allows researchers to perform appropriate procedures while the samples remain inside the controlled environment.
Its operating range and configuration should still be compared with the requirements of the intended testing protocol.
The ETS Model 518 is not a Class II biological safety cabinet or a pharmaceutical containment isolator.
Its acrylic enclosure and environmental controls do not establish validated protection against infectious aerosols, hazardous powders, or chemical vapors.
The chamber should be selected for appropriate environmental control applications rather than assumed to provide specialized biological or chemical containment.
American Instrument Exchange inspects and tests used controlled-environment chambers before shipment.
For the ETS Model 518, technicians evaluate the acrylic enclosure, access door, glove ports, seals, humidity controller, temperature controller, humidification and dehumidification systems, heater, cooling components, circulation fan, lighting, electrical systems, and other installed equipment.
Temperature and humidity control functions are tested to evaluate their response to selected operating conditions.
The chamber is inspected for cracks, damaged seals, and other physical defects.
Accessible interior and exterior surfaces are thoroughly cleaned before shipment.
The ETS Model 518 combines precision temperature and humidity control with the convenience of a glove-access laboratory enclosure.
For laboratories conducting environmental materials testing, electronics research, packaging evaluation, or humidity-sensitive experiments, purchasing a refurbished Model 518 can provide substantial cost savings compared with acquiring a new controlled-environment system.
Its integrated design provides both heating and cooling, humidification and dehumidification, automatic control, and a large working chamber.
American Instrument Exchange tests and cleans the system before shipment and includes a 90-day warranty.
The Model 518 measures approximately 47 inches wide × 25.5 inches deep × 22 inches high.
Before purchase, customers should confirm sufficient bench or stand space, electrical service, access for the side door, and room for the external equipment required by the installed environmental-control systems.
Cooling requires an appropriate liquid CO₂ supply with a dip-tube cylinder and suitable high-pressure connection.
The system should be installed in a properly ventilated laboratory with appropriate compressed-gas safety precautions.
The chamber's temperature and humidity performance should be verified under the intended operating conditions before critical testing begins.
Laboratories using an Electro-Tech Systems Model 518 may also require environmental test chambers, laboratory ovens, desiccators, analytical balances, precision balances, laboratory refrigerators, laboratory freezers, incubators, glove boxes, vacuum ovens, and other equipment supporting controlled-environment research and materials testing.
American Instrument Exchange supplies used and refurbished environmental chambers, glove boxes, laboratory balances, incubators, ovens, cold-storage equipment, and other laboratory instruments for industrial, pharmaceutical, biotechnology, academic, and research laboratories.
The ETS Model 518 is an airtight acrylic glove box with integrated automatic temperature and relative humidity control.
The manufacturer specifies 5–98% relative humidity at laboratory ambient temperature.
The manufacturer specifies approximately ±0.5% RH stability under appropriate operating conditions.
The chamber is designed for temperature control from 0°C to 50°C.
The manufacturer specifies approximately ±0.5°C temperature stability.
Not necessarily. The maximum achievable humidity depends on the selected temperature and operating conditions. Heating and liquid CO₂ cooling can limit the humidity range.
It uses an ultrasonic humidification system controlled by the ETS Model 514 humidity controller.
It uses a desiccant-based dehumidification system.
A 500-watt electric heater provides heating.
Cooling is produced through expansion of liquid carbon dioxide supplied from an appropriate external cylinder.
Yes. The original system uses a liquid CO₂ supply, with a dip-tube cylinder and suitable high-pressure connections.
The Model 518 provides approximately 13 cubic feet of usable chamber space.
The chamber measures approximately 47"W × 25.5"D × 22"H.
Yes. The Model 518 has two glove ports for handling materials within the controlled environment.
Yes. Temperature and humidity control can support research into electronic components, electrostatic behavior, insulation properties, and moisture-sensitive materials.
Yes. The chamber can support appropriate humidity and temperature conditioning of packaging materials and related specimens.
No. Its primary environmental controls regulate temperature and relative humidity, not oxygen concentration.
No. The Model 518 should not be substituted for a biological safety cabinet when biological containment is required.
Yes. This unit is used and refurbished by American Instrument Exchange.
Yes. American Instrument Exchange includes a 90-day warranty with this refurbished ETS Model 518.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.