Electro-Tech Systems Model 518 Temperature and Humidity Controlled Glove Box

Fully Tested & Warrantied*
Brand : Integra
Product Code : SKU 2722 GLOVE BOX
Title: $6300.00

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Electro-Tech Systems Model 518 Temperature and Humidity Controlled Glove Box – Used and Refurbished

The Electro-Tech Systems Model 518 Controlled Environment Chamber is a precision laboratory glove box designed for testing, handling, fabrication, and storage of materials under controlled temperature and relative humidity conditions. Manufactured by Electro-Tech Systems (ETS), the Model 518 combines an airtight acrylic enclosure with automatic temperature and humidity regulation, allowing researchers to perform sensitive procedures without exposing materials to uncontrolled laboratory conditions.

The ETS Model 518 provides a relative humidity control range of 5% to 98% RH at laboratory ambient temperature, with manufacturer-specified stability of approximately ±0.5% RH. Temperature can be controlled from 0°C to 50°C, with stability of approximately ±0.5°C under appropriate operating conditions.

The chamber uses separate automatic control systems for temperature and humidity. Ultrasonic humidification increases moisture, desiccant-based dehumidification removes moisture, an electric heater raises temperature, and a liquid carbon dioxide cooling system provides cooling when properly connected to an external CO₂ supply.

Two glove ports allow users to manipulate materials within the controlled environment. The approximately 13-cubic-foot working chamber provides substantial space for laboratory instruments, test specimens, electronics, packaging materials, and other humidity- or temperature-sensitive products.

Unlike hypoxia chambers designed to regulate oxygen and CO₂ for biological research, the Model 518 is primarily intended for environmental testing and material conditioning. Its combination of humidity and temperature control makes it especially useful for electronics research, electrostatic testing, materials science, pharmaceutical research, packaging evaluation, and quality-control applications.

This Electro-Tech Systems Model 518 is used and refurbished by American Instrument Exchange. The unit is inspected, tested, and cleaned before shipment and includes a 90-day warranty.

Key Features

  • Electro-Tech Systems Model 518 Controlled Environment Chamber

  • Integrated temperature and relative humidity control

  • Approximately 13 cubic feet of usable chamber space

  • Relative humidity range of 5–98% RH at laboratory ambient temperature

  • Humidity stability of approximately ±0.5% RH

  • Temperature range of 0–50°C

  • Temperature stability of approximately ±0.5°C

  • Two glove ports for material handling

  • Clear and white acrylic chamber construction

  • ETS Model 514 automatic humidity controller

  • ETS Model 513A automatic temperature controller

  • Ultrasonic humidification system

  • Desiccant-based dehumidification

  • Electric heating system

  • Liquid CO₂ cooling capability

  • Internal circulation fan

  • Integrated chamber lighting

  • Side access door

  • Cable and tubing access

  • Used and refurbished by American Instrument Exchange

  • 90-day warranty included

Overview

Many laboratory and industrial processes are sensitive to changes in temperature and relative humidity.

Moisture can affect electrical resistance, electrostatic charge accumulation, material dimensions, chemical stability, surface properties, packaging performance, and other characteristics.

Temperature changes can also influence material behavior, instrument performance, and experimental results.

The Electro-Tech Systems Model 518 provides a controlled environment in which these variables can be adjusted and maintained independently.

Its airtight acrylic enclosure reduces the influence of surrounding room conditions, while integrated controllers automatically respond to changes in the chamber environment.

Two glove ports allow operators to manipulate samples and equipment without routinely opening the chamber and disturbing the selected environmental conditions.

Common Applications

The ETS Model 518 is suitable for humidity-sensitive materials testing, electrostatic research, electronic component evaluation, printed circuit board research, packaging studies, pharmaceutical material conditioning, polymer testing, adhesive research, coating evaluation, moisture-sensitive sample handling, environmental quality control, and other applications requiring controlled temperature and humidity.

It may also support laboratory procedures in which samples must be manipulated under defined environmental conditions rather than simply stored in a temperature- or humidity-controlled cabinet.

Ideal Laboratory Types

The Model 518 is well suited to electronics laboratories, materials science facilities, pharmaceutical research laboratories, industrial quality-control departments, packaging development laboratories, polymer research groups, academic research institutions, semiconductor research facilities, electrostatics laboratories, and manufacturing R&D departments.

Its combination of controlled humidity, temperature regulation, and glove-port access makes it particularly useful for applications where maintaining environmental conditions during handling is important.

Key Specifications

Specification Details
Manufacturer Electro-Tech Systems (ETS)
Model 518
AIE Inventory Number 2722
Equipment Type Temperature and Humidity Controlled Glove Box
Chamber Capacity Approximately 13 cu ft
Exterior Dimensions 47"W × 25.5"D × 22"H
Interior Dimensions Approximately 39"W × 22.5"D × 21–22"H
Relative Humidity Range 5–98% RH at Laboratory Ambient
Humidity Stability Approximately ±0.5% RH
Temperature Range 0–50°C
Temperature Stability Approximately ±0.5°C
Humidity Controller ETS Model 514
Temperature Controller ETS Model 513A
Humidification Ultrasonic
Dehumidification Desiccant System
Heating 500 W Electric Heater
Cooling Liquid CO₂ Expansion System
Chamber Construction Clear and White Acrylic
Glove Access Two Ports
Internal Circulation Fan
Chamber Lighting 15 W Fluorescent
Access Side Door and Cable/Tubing Port
Condition Used / Refurbished
Warranty 90 Days from American Instrument Exchange

Precision Relative Humidity Control

The Model 518 is designed to maintain controlled humidity across a broad range.

Electro-Tech Systems specifies a relative humidity range of 5% to 98% at laboratory ambient temperature, with stability of approximately ±0.5% RH under appropriate conditions.

This allows researchers to evaluate materials under both dry and high-humidity environments.

Humidity can influence electrical properties, dimensional stability, moisture absorption, surface conductivity, adhesive performance, and many other material characteristics.

The ability to establish a selected humidity level helps researchers reduce environmental variability between tests.

ETS Model 514 Humidity Controller

The Model 518 incorporates an ETS Model 514 automatic humidity controller.

The controller measures chamber humidity and compares the actual reading with the selected setpoint.

Its display provides humidity readings and setpoint information, while the control system activates humidification or dehumidification equipment as required.

The controller offers 0.1% RH display resolution, allowing precise adjustment and observation of chamber conditions.

Ultrasonic Humidification

When humidity must be increased, the Model 518 uses an ultrasonic humidification system.

Ultrasonic humidification generates a fine water mist that is introduced into the chamber environment.

The automatic humidity controller activates the humidifier when relative humidity falls below the selected level.

This provides a means of establishing elevated humidity conditions for materials testing and environmental conditioning.

Water quality and humidifier maintenance should follow the manufacturer's recommendations to minimize mineral deposits and contamination.

Desiccant-Based Dehumidification

Low-humidity operation is achieved using a desiccant-based dehumidification system.

Desiccant removes moisture from the chamber atmosphere, allowing the system to establish dry conditions without relying solely on continuous gas purging.

This is useful for moisture-sensitive electronics, polymers, packaging materials, and other specimens requiring reduced relative humidity.

Desiccant condition and regeneration or replacement requirements should be evaluated as part of routine maintenance.

Automatic Temperature Control

The Model 518 also incorporates an independent temperature-control system.

Electro-Tech Systems specifies a temperature range of 0°C to 50°C, with stability of approximately ±0.5°C under appropriate conditions.

Temperature regulation allows researchers to evaluate material behavior under controlled thermal conditions while simultaneously monitoring relative humidity.

The actual achievable temperature range depends on ambient laboratory conditions and the installed heating and cooling systems.

ETS Model 513A Temperature Controller

The ETS Model 513A provides automatic temperature regulation.

It compares measured chamber temperature with the selected setpoint and activates heating or cooling as required.

This independent control arrangement allows temperature to be managed separately from relative humidity, although the two environmental variables remain physically interdependent.

Electric Heating System

The Model 518 uses a 500-watt electric heater to raise chamber temperature.

The heating element is positioned behind an internal aluminum panel.

A thermal safety switch provides protection against excessive temperature.

This system allows the chamber to maintain elevated temperatures for appropriate materials testing and conditioning procedures.

Liquid CO₂ Cooling

One of the more unusual features of the Model 518 is its cooling system.

Rather than relying on a conventional compressor-based refrigeration circuit, the chamber uses expansion of liquid carbon dioxide to produce cooling.

The original manufacturer documentation specifies a liquid CO₂ cylinder equipped with a dip tube and an appropriate high-pressure connection.

When cooling is required, the controller opens a solenoid valve, allowing liquid CO₂ to expand into gas and produce a cooling effect.

The liquid CO₂ supply and associated equipment must be properly installed and handled according to applicable gas-safety procedures.

Temperature and Humidity Interaction

Temperature and relative humidity are closely related.

Changing chamber temperature affects relative humidity even when the amount of water vapor present remains unchanged.

The Model 518 therefore uses separate control systems that work together to maintain selected conditions.

However, the full advertised temperature and humidity ranges should not be interpreted as simultaneously achievable at every combination.

Electric heating can reduce relative humidity, while the dry CO₂ gas used for cooling can limit the maximum humidity achievable during cooling.

Researchers should verify that their intended temperature and humidity combination is within the practical operating capabilities of the chamber.

Low-Humidity Testing

Low-humidity environments can be useful when studying moisture-sensitive electronic components, materials, packaging, and other products.

Reducing humidity may help researchers investigate drying behavior, material stability, electrical insulation properties, and other environmental responses.

The Model 518 provides a controlled alternative to exposing samples to changing laboratory humidity.

High-Humidity Testing

Elevated humidity conditions can be useful for evaluating moisture absorption, packaging performance, polymer behavior, coating properties, and other characteristics.

The ultrasonic humidification system allows the chamber to establish high relative humidity conditions when operating temperature and other environmental factors permit.

The chamber should not automatically be considered a validated environmental aging or accelerated-life-testing system without application-specific qualification.

Electrostatic Research

Humidity can strongly influence electrostatic charge accumulation and dissipation.

Dry environments may allow static charge to persist, while higher humidity can change the surface conductivity of many materials.

The Model 518 allows researchers to investigate these effects under controlled environmental conditions.

The standard acrylic enclosure should not automatically be assumed to have specialized electrostatic-dissipative construction unless that option is verified.

Electronics and Semiconductor Research

Electronic components and assemblies may be sensitive to humidity and temperature during handling, fabrication, testing, or storage.

The Model 518 provides a controlled environment for investigating these effects.

Potential applications include component evaluation, insulation testing, electrostatic behavior, materials characterization, and research involving moisture-sensitive assemblies.

Its glove-port access allows operators to handle specimens without immediately exposing them to uncontrolled room conditions.

Packaging and Materials Testing

Packaging materials can absorb moisture, change dimensions, or exhibit different barrier and mechanical properties under changing environmental conditions.

The Model 518 allows researchers to condition specimens at selected temperature and humidity levels.

This can support packaging development, polymer research, adhesive evaluation, and quality-control investigations.

Pharmaceutical and Chemical Research

Moisture and temperature can affect pharmaceutical powders, excipients, packaging materials, and other research samples.

The Model 518 may support appropriate non-hazardous material conditioning and testing under controlled environmental conditions.

However, the chamber should not be assumed to provide hazardous-powder containment, chemical-vapor protection, or pharmaceutical aseptic conditions.

Applications involving hazardous materials require separate evaluation of the chamber's suitability.

Two Glove Ports

Two glove ports allow operators to manipulate materials inside the chamber without opening the side access door.

This is especially useful when the environmental conditions must remain stable during a procedure.

Opening a chamber door can introduce room air and disrupt humidity and temperature.

Glove-port access reduces the need for these interruptions.

The condition and inclusion of gloves and sleeves should be confirmed for the individual AIE unit.

Large Acrylic Working Chamber

The Model 518 provides approximately 13 cubic feet of usable working space.

The chamber is constructed from clear and white acrylic, allowing users to observe equipment and specimens during testing.

Its generous interior accommodates a range of instruments, test fixtures, sample holders, and other laboratory materials.

Equipment placement should preserve airflow and avoid obstructing the temperature and humidity sensors.

Side Access Door

A side access door provides a convenient method for introducing or removing equipment and specimens.

This is useful when items are too large or awkward to transfer through the glove ports.

After opening the door, the chamber may require time to return to the selected temperature and humidity conditions.

Cable and Tubing Access

The Model 518 includes an access opening for routing cables and tubing into the controlled environment.

This allows compatible instruments, sensors, and test equipment to operate inside the chamber while remaining connected to external equipment.

Connections should be properly sealed to minimize uncontrolled air exchange.

Internal Air Circulation

An internal circulation fan helps distribute conditioned air throughout the chamber.

Air movement promotes more consistent temperature and humidity conditions around specimens and instruments.

Large equipment or densely packed samples should be positioned to avoid unnecessary obstruction of circulation.

Integrated Lighting

The Model 518 includes a 15-watt fluorescent chamber light.

Interior illumination improves visibility when handling samples or adjusting instruments through the glove ports.

The lighting system can be controlled independently from the environmental regulation functions.

Model 518 vs. Conventional Laboratory Glove Box

A conventional glove box may provide only a physical barrier between materials and the surrounding room.

The ETS Model 518 adds automatic control of both temperature and relative humidity.

This makes it an environmental testing chamber rather than simply a sealed enclosure.

Its principal advantage is the ability to handle specimens while maintaining defined atmospheric moisture and temperature conditions.

Model 518 vs. Nitrogen Dry Box

A nitrogen dry box typically relies on dry gas purging to reduce oxygen and moisture.

The Model 518 instead uses automatic humidity regulation, including both humidification and dehumidification.

It can establish dry conditions or deliberately elevated humidity levels.

It is not primarily designed to maintain an inert atmosphere or precisely regulate oxygen concentration.

Model 518 vs. Hypoxia Chamber

Hypoxia chambers such as the Coy and Plas-Labs systems are designed primarily to regulate oxygen concentration for biological research.

The ETS Model 518 is designed around temperature and humidity.

It should not be represented as an oxygen-controlled cell-culture workstation or a substitute for a tri-gas incubator.

Model 518 vs. Environmental Test Chamber

A conventional environmental test chamber may provide temperature and humidity control but often requires opening a door to manipulate specimens.

The Model 518 adds glove-port access.

This allows researchers to perform appropriate procedures while the samples remain inside the controlled environment.

Its operating range and configuration should still be compared with the requirements of the intended testing protocol.

Not a Biosafety Cabinet or Hazardous-Drug Isolator

The ETS Model 518 is not a Class II biological safety cabinet or a pharmaceutical containment isolator.

Its acrylic enclosure and environmental controls do not establish validated protection against infectious aerosols, hazardous powders, or chemical vapors.

The chamber should be selected for appropriate environmental control applications rather than assumed to provide specialized biological or chemical containment.

Refurbishment and Testing by American Instrument Exchange

American Instrument Exchange inspects and tests used controlled-environment chambers before shipment.

For the ETS Model 518, technicians evaluate the acrylic enclosure, access door, glove ports, seals, humidity controller, temperature controller, humidification and dehumidification systems, heater, cooling components, circulation fan, lighting, electrical systems, and other installed equipment.

Temperature and humidity control functions are tested to evaluate their response to selected operating conditions.

The chamber is inspected for cracks, damaged seals, and other physical defects.

Accessible interior and exterior surfaces are thoroughly cleaned before shipment.

Why Buy a Refurbished ETS Model 518?

The ETS Model 518 combines precision temperature and humidity control with the convenience of a glove-access laboratory enclosure.

For laboratories conducting environmental materials testing, electronics research, packaging evaluation, or humidity-sensitive experiments, purchasing a refurbished Model 518 can provide substantial cost savings compared with acquiring a new controlled-environment system.

Its integrated design provides both heating and cooling, humidification and dehumidification, automatic control, and a large working chamber.

American Instrument Exchange tests and cleans the system before shipment and includes a 90-day warranty.

Shipping and Installation

The Model 518 measures approximately 47 inches wide × 25.5 inches deep × 22 inches high.

Before purchase, customers should confirm sufficient bench or stand space, electrical service, access for the side door, and room for the external equipment required by the installed environmental-control systems.

Cooling requires an appropriate liquid CO₂ supply with a dip-tube cylinder and suitable high-pressure connection.

The system should be installed in a properly ventilated laboratory with appropriate compressed-gas safety precautions.

The chamber's temperature and humidity performance should be verified under the intended operating conditions before critical testing begins.

Related Equipment

Laboratories using an Electro-Tech Systems Model 518 may also require environmental test chambers, laboratory ovens, desiccators, analytical balances, precision balances, laboratory refrigerators, laboratory freezers, incubators, glove boxes, vacuum ovens, and other equipment supporting controlled-environment research and materials testing.

American Instrument Exchange supplies used and refurbished environmental chambers, glove boxes, laboratory balances, incubators, ovens, cold-storage equipment, and other laboratory instruments for industrial, pharmaceutical, biotechnology, academic, and research laboratories.

Electro-Tech Systems Model 518 FAQs

What is the Electro-Tech Systems Model 518?

The ETS Model 518 is an airtight acrylic glove box with integrated automatic temperature and relative humidity control.

What is the humidity range?

The manufacturer specifies 5–98% relative humidity at laboratory ambient temperature.

How stable is the humidity control?

The manufacturer specifies approximately ±0.5% RH stability under appropriate operating conditions.

What is the temperature range?

The chamber is designed for temperature control from 0°C to 50°C.

How stable is temperature control?

The manufacturer specifies approximately ±0.5°C temperature stability.

Can the chamber maintain 98% RH at 0°C?

Not necessarily. The maximum achievable humidity depends on the selected temperature and operating conditions. Heating and liquid CO₂ cooling can limit the humidity range.

How does the Model 518 increase humidity?

It uses an ultrasonic humidification system controlled by the ETS Model 514 humidity controller.

How does it reduce humidity?

It uses a desiccant-based dehumidification system.

How does the chamber heat?

A 500-watt electric heater provides heating.

How does the chamber cool?

Cooling is produced through expansion of liquid carbon dioxide supplied from an appropriate external cylinder.

Does the cooling system require a CO₂ cylinder?

Yes. The original system uses a liquid CO₂ supply, with a dip-tube cylinder and suitable high-pressure connections.

What is the chamber capacity?

The Model 518 provides approximately 13 cubic feet of usable chamber space.

What are the exterior dimensions?

The chamber measures approximately 47"W × 25.5"D × 22"H.

Does it have glove ports?

Yes. The Model 518 has two glove ports for handling materials within the controlled environment.

Is the chamber suitable for electronics research?

Yes. Temperature and humidity control can support research into electronic components, electrostatic behavior, insulation properties, and moisture-sensitive materials.

Can it be used for packaging studies?

Yes. The chamber can support appropriate humidity and temperature conditioning of packaging materials and related specimens.

Is the Model 518 an oxygen-control glove box?

No. Its primary environmental controls regulate temperature and relative humidity, not oxygen concentration.

Is it a biosafety cabinet?

No. The Model 518 should not be substituted for a biological safety cabinet when biological containment is required.

Is this Electro-Tech Systems Model 518 refurbished?

Yes. This unit is used and refurbished by American Instrument Exchange.

Does it include a warranty?

Yes. American Instrument Exchange includes a 90-day warranty with this refurbished ETS Model 518.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.