Eppendorf 5430R Refrigerated Centrifuge with S-24-11-AT Rotor

Fully Tested & Warrantied*
Brand : Eppendorf
Product Code : SKU 1268C CENTRI
Sold Out
⚠

Currently Unavailable

This item is temporarily out of stock. Please contact us for availability updates or explore similar alternatives below.

We Can Help You Find:

  • Similar equipment currently in stock
  • Alternative brands with comparable specifications
  • Refurbished units (fully tested & warrantied)

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Eppendorf 5430R Refrigerated Centrifuge with S-24-11-AT Swinging-Bucket Rotor

The Eppendorf 5430R Refrigerated Centrifuge with S-24-11-AT Rotor combines high-speed microcentrifugation, precise temperature control, and swinging-bucket rotor technology in a versatile benchtop instrument. Designed for molecular biology, biotechnology, genomics, proteomics, and general laboratory research, the Eppendorf 5430R centrifuge provides reliable performance for laboratories processing temperature-sensitive biological samples.

This particular Eppendorf 5430R is available used and refurbished from American Instrument Exchange and includes the Eppendorf S-24-11-AT aerosol-tight swinging-bucket rotor. The rotor accommodates 24 standard 1.5/2.0 mL microcentrifuge tubes and operates at speeds up to 12,700 RPM, generating centrifugal forces up to 16,049 × g.

Unlike conventional fixed-angle microcentrifuge rotors, the S-24-11-AT allows sample tubes to swing outward into a horizontal position during centrifugation. This design directs sedimentation toward the bottom of the tubes rather than along the outer tube wall, making it useful for procedures requiring consistent pellet positioning and efficient sample recovery.

The refrigerated 5430R platform supports 12 rotor configurations and can reach maximum speeds of 17,500 RPM and centrifugal forces of 30,130 × g with an appropriate high-speed rotor. Its temperature range of -11°C to +40°C helps laboratories maintain controlled conditions for sensitive proteins, enzymes, nucleic acids, and other biological materials.

American Instrument Exchange professionally inspects, cleans, and tests refurbished centrifuges before shipment. This unit includes a 90-day warranty.

Key Features

  • Includes Eppendorf S-24-11-AT swinging-bucket rotor

  • Aerosol-tight rotor design with QuickLock lid system

  • Capacity for 24 × 1.5/2.0 mL microcentrifuge tubes

  • Included rotor maximum speed of 12,700 RPM

  • Included rotor maximum RCF of 16,049 × g

  • Horizontal tube positioning during centrifugation

  • Maximum centrifuge platform speed of 17,500 RPM

  • Maximum platform RCF of 30,130 × g, rotor dependent

  • Refrigerated temperature range from -11°C to +40°C

  • FastTemp pre-cooling for temperature-sensitive samples

  • Automatic rotor recognition and imbalance detection

  • SOFT brake function for sensitive pellets

  • Stores up to 50 user-defined programs

  • Five direct-access program keys

  • Large backlit display

  • Compatible with 12 Eppendorf rotor configurations

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview of the Eppendorf 5430R

The Eppendorf 5430R was developed to bridge the gap between compact microcentrifuges and larger multipurpose laboratory centrifuges.

Traditional microcentrifuges are generally optimized for small-volume samples processed in fixed-angle rotors. Larger general-purpose centrifuges provide greater rotor flexibility but often require substantially more bench space.

The 5430R combines these capabilities in a refrigerated instrument that supports microcentrifuge tubes, conical tubes, PCR formats, microplates, and other laboratory vessels with appropriate rotor configurations.

With the included S-24-11-AT rotor, this particular centrifuge is configured for swinging-bucket microcentrifugation rather than conventional fixed-angle separation. This makes it particularly useful for laboratories requiring controlled sedimentation of small-volume samples while maintaining refrigerated operating conditions.

The instrument's programmable controls, automatic rotor recognition, and pre-cooling functions also make it suitable for shared laboratory environments where different researchers may require consistent operating parameters.

Common Applications

The Eppendorf 5430R with S-24-11-AT rotor is well suited for laboratory procedures requiring controlled sedimentation of small-volume biological samples.

Common applications include molecular biology research, DNA and RNA sample preparation, protein precipitation, enzyme preparation, cell lysate processing, microbiology research, biotechnology applications, pharmaceutical research, and general refrigerated microcentrifugation.

The swinging-bucket rotor is particularly useful for procedures where pellet location and recovery are important considerations. Refrigeration also makes the centrifuge suitable for protocols involving temperature-sensitive proteins, enzymes, nucleic acids, and other biological materials.

For laboratories performing repeated sample-preparation procedures, the 24-place capacity allows multiple samples to be processed simultaneously while maintaining consistent operating conditions.

Included S-24-11-AT Swinging-Bucket Rotor

This Eppendorf 5430R centrifuge includes the S-24-11-AT aerosol-tight swinging-bucket rotor, designed specifically for 24 standard 1.5/2.0 mL microcentrifuge tubes.

The rotor operates at a maximum speed of 12,700 RPM and generates centrifugal forces up to 16,049 × g.

During centrifugation, the rotor's tube holders swing outward until the tubes are positioned horizontally. This changes the direction of sedimentation compared with a fixed-angle rotor, allowing particles to collect toward the bottom of the vessel.

The S-24-11-AT incorporates Eppendorf's QuickLock rotor lid system, providing convenient access while maintaining an aerosol-tight configuration when the appropriate lid and sealing components are properly installed.

The rotor must always be operated with its designated lid.

Eppendorf specifies that the S-24-11-AT is intended exclusively for 1.5/2.0 mL reaction vessels. Spin columns, smaller tubes, and adapters for 0.2 mL, 0.4 mL, 0.5 mL, and 0.6 mL vessels are not approved for use with this rotor.

Laboratories requiring those sample formats should select another compatible Eppendorf rotor. Customers should verify all included rotor accessories before purchase.

Key Specifications

Specification Details
Manufacturer Eppendorf
Model 5430R
Condition Used / Refurbished
Centrifuge Type Refrigerated Crossover Microcentrifuge
Included Rotor S-24-11-AT Swinging-Bucket Rotor
Rotor Catalog Number 5427757007
Rotor Capacity 24 × 1.5/2.0 mL
Rotor Design Swinging-Bucket, Aerosol-Tight
Included Rotor Maximum Speed 12,700 RPM
Included Rotor Maximum RCF 16,049 × g
Maximum Platform Speed 17,500 RPM, rotor dependent
Maximum Platform RCF 30,130 × g, rotor dependent
Speed Range 100–17,500 RPM
Temperature Range -11°C to +40°C
Refrigeration CFC-Free
Compatible Rotor Configurations 12
User-Defined Programs Up to 50
Direct-Access Program Keys 5
Timer 30 Seconds to 99 Hours 59 Minutes, Plus Continuous Operation
SOFT Brake Yes
Rotor Recognition Automatic
Imbalance Detection Automatic
Dimensions 15.0"W × 25.2"D × 11.7"H
Height with Lid Open Approximately 24.8"
Weight Without Rotor Approximately 123.5 lb
Electrical Requirements 120V, 50/60 Hz
Maximum Power Consumption 1,050 W
Warranty 90 Days

Specifications compiled from Eppendorf manufacturer literature and technical documentation. Maximum speed and centrifugal force depend on the installed rotor.

Swinging-Bucket Centrifugation and Sample Recovery

The S-24-11-AT provides a different sedimentation geometry from the fixed-angle rotors commonly supplied with high-speed microcentrifuges.

In a fixed-angle rotor, particles typically sediment along the outer wall of the tube before collecting toward the bottom. This can produce a pellet extending along the side of the vessel.

With a swinging-bucket rotor, the tubes move into a horizontal position during operation, directing sedimentation toward the bottom of the tube.

This can be advantageous for procedures where laboratories want more predictable pellet positioning, particularly when recovering supernatant or handling delicate biological material.

For laboratories processing 24 microcentrifuge tubes at a time, the S-24-11-AT provides a useful combination of sample capacity, high centrifugal force, and controlled sedimentation geometry.

Eppendorf 5430R centrifuge Refrigeration and Temperature Stability

The Eppendorf 5430R provides an adjustable temperature range from -11°C to +40°C, allowing laboratories to select operating conditions appropriate for their samples.

High-speed centrifugation generates heat, and temperature increases can affect sensitive biological materials. The 5430R refrigeration system helps maintain controlled chamber conditions during centrifugation.

Its FastTemp function allows the instrument to be pre-cooled before samples are loaded, reducing unnecessary exposure of temperature-sensitive materials to ambient conditions.

The centrifuge also supports FastTemp pro programming, allowing laboratories to schedule pre-cooling around routine operating requirements.

These capabilities are particularly useful for laboratories performing repeated sample-preparation procedures involving proteins, enzymes, nucleic acids, and other biological materials.

Actual sample temperature depends on rotor selection, operating speed, sample load, ambient conditions, and other operating parameters.

Rotor Compatibility and Additional Applications

Although this particular Eppendorf 5430R includes the S-24-11-AT swinging-bucket rotor, the centrifuge supports 12 compatible rotor configurations.

Additional rotor options allow laboratories to process standard microcentrifuge tubes, Eppendorf 5.0 mL tubes, 15 mL and 50 mL conical tubes, PCR tubes and strips, cryotubes, spin columns, and microplates.

With an appropriate high-speed fixed-angle rotor, the centrifuge can reach its maximum platform performance of 17,500 RPM and 30,130 × g.

This versatility allows the 5430R to serve multiple laboratory functions without requiring separate centrifuges for every sample format.

For laboratories that initially require swinging-bucket microtube processing, the ability to add compatible rotors later can extend the instrument's usefulness as research requirements change.

Additional rotors and adapters are not included unless specifically listed. Customers should verify included rotors and accessories before purchase.

Power Requirements and Shipping

The Eppendorf 5430R operates on 120V, 50/60 Hz electrical service, making it suitable for installation in many U.S. laboratory environments.

The centrifuge measures approximately 15.0 inches wide × 25.2 inches deep × 11.7 inches high and weighs approximately 123.5 pounds without a rotor.

Approximately 24.8 inches of vertical clearance is required with the centrifuge lid fully open.

The instrument should be positioned on a sturdy, level laboratory bench with adequate ventilation clearance to support refrigeration performance.

American Instrument Exchange prepares centrifuges for secure shipment, with appropriate protection for the rotor chamber, drive assembly, refrigeration components, controls, and other sensitive parts.

Refurbished Eppendorf Centrifuges from American Instrument Exchange

American Instrument Exchange technicians inspect and test refurbished centrifuges before shipment to verify proper mechanical and electrical operation.

Testing includes evaluation of the drive motor, spindle and bearing condition, rotating assembly balance, braking, electronic controls, lid safety mechanisms, rotor recognition, and overall operating performance.

Because the Eppendorf 5430R is refrigerated, technicians also evaluate the cooling system to verify that the instrument reaches and maintains appropriate operating temperatures.

The included S-24-11-AT rotor is inspected for structural integrity, wear, corrosion, and proper operation. The rotor and centrifuge are tested together as a complete system.

The instrument is thoroughly cleaned and prepared for shipment after testing.

This refurbished Eppendorf 5430R includes a 90-day warranty from American Instrument Exchange.

Service and Support

American Instrument Exchange and AIE Laboratory Services provide diagnostic evaluation, preventative maintenance, and repair support for centrifuges and other laboratory equipment.

For an Eppendorf 5430R, service evaluation may include the motor, spindle assembly, bearings, braking system, refrigeration components, temperature sensors, rotor recognition, electronic controls, and lid safety mechanisms.

Our technicians can help laboratories determine whether repair or replacement with another refurbished centrifuge is the more economical solution.

Related Laboratory Equipment

American Instrument Exchange offers a broad selection of used and refurbished laboratory centrifuges, including Eppendorf microcentrifuges, refrigerated benchtop centrifuges, general-purpose centrifuges, and high-speed floor-model systems.

Laboratories performing molecular biology, biotechnology, and cell culture research may also be interested in our selection of laboratory incubators, laboratory freezers and ultra-low freezers, and biosafety cabinets.

Eppendorf 5430R with S-24-11-AT Rotor Frequently Asked Questions

What rotor is included with this Eppendorf 5430R?

This particular centrifuge includes the Eppendorf S-24-11-AT aerosol-tight swinging-bucket rotor, designed for 24 standard 1.5/2.0 mL microcentrifuge tubes.

What is the maximum speed of the S-24-11-AT rotor?

The S-24-11-AT operates at speeds up to 12,700 RPM and generates centrifugal forces up to 16,049 × g.

Is the S-24-11-AT a fixed-angle or swinging-bucket rotor?

The S-24-11-AT is a swinging-bucket rotor. Its tube holders move into a horizontal position during centrifugation, allowing sedimentation toward the bottom of the tubes.

Is the S-24-11-AT rotor aerosol-tight?

Yes. The S-24-11-AT incorporates an aerosol-tight rotor lid system when the correct lid and sealing components are installed and maintained according to Eppendorf instructions.

Can the S-24-11-AT process spin columns?

No. Eppendorf specifies that spin columns are not approved for use with this rotor. Laboratories processing spin columns should select an appropriate compatible fixed-angle rotor.

Can the S-24-11-AT accommodate smaller microtubes with adapters?

No. The S-24-11-AT is designed exclusively for 1.5/2.0 mL reaction vessels. Adapters for smaller tube sizes are not approved for this rotor.

What is the advantage of a swinging-bucket microtube rotor?

A swinging-bucket rotor positions tubes horizontally during centrifugation, directing sedimentation toward the bottom of the vessel. This can be useful for applications where consistent pellet positioning and sample recovery are important.

What temperature range does the Eppendorf 5430R provide?

The centrifuge offers an adjustable temperature range from -11°C to +40°C. Actual sample temperature depends on operating conditions and rotor selection.

Why is the centrifuge rated for 30,130 × g if the included rotor only reaches 16,049 × g?

The 30,130 × g specification represents the maximum capability of the centrifuge platform with an appropriate high-speed rotor. The included S-24-11-AT is designed for swinging-bucket microtube processing and therefore operates at a lower maximum centrifugal force.

Can the Eppendorf 5430R accommodate 15 mL and 50 mL conical tubes?

Yes. With an appropriate compatible rotor, such as the F-35-6-30, the 5430R can process 15 mL and 50 mL conical tubes. The included S-24-11-AT rotor is designed only for 1.5/2.0 mL tubes.

How does the Eppendorf 5430R compare with the non-refrigerated 5430?

The primary difference is refrigeration. The 5430R provides controlled temperatures from -11°C to +40°C, while the non-refrigerated 5430 is smaller, lighter, and intended for applications that do not require active cooling. Both platforms support a broad selection of compatible rotors.

Why purchase a refurbished Eppendorf 5430R?

A professionally tested refurbished Eppendorf 5430R can provide versatile refrigerated centrifugation at a lower acquisition cost than a new instrument. With the included S-24-11-AT rotor, it is particularly well suited for laboratories requiring high-speed swinging-bucket microtube processing and controlled sample temperatures.

Testing Procedures for Used and Refurbished Laboratory Centrifuges

Ensure Quality, Accuracy, and Compliance Before Deployment

Used and refurbished laboratory centrifuges from American Instrument Exchange undergo testing procedures to ensure they meet the performance, safety, and compliance standards required in modern laboratories.

Why Testing Used Laboratory Centrifuges Is Essential

Before a centrifuge is reintroduced into a lab environment, it must be tested for:

  • Mechanical integrity
  • Rotor balance and speed accuracy
  • Safety system functionality
  • Electrical compliance

Proper testing helps extend equipment lifespan, reduce downtime, and ensure safety in high-stakes lab environments such as clinical diagnostics, biotechnology, and research applications.

Our structured testing protocol for used and refurbished centrifuges ensures equipment safety, accuracy, and longevity.

Key Testing Procedures for Refurbished and Used Centrifuges

1. Initial Visual Inspection

  • Check for signs of wear, corrosion, or damage to housing, lid, and control panels
  • Inspect power cords, plugs, and connectors for fraying or exposed wiring
  • Confirm that the rotor and accessories are compatible and undamaged

2. Functional Testing

  • Power up the centrifuge and confirm successful boot-up of digital or analog displays
  • Test lid lock and emergency stop mechanisms
  • Run initial cycles at various speeds to check for abnormal noise or vibration

3. Rotor and Speed Verification

  • Test all programmable speed settings to confirm consistent acceleration and deceleration
  • Monitor temperature, vibration, and RPM consistency throughout the cycle
  • Balance testing ensures smooth operation and prevents wear on internal components

4. Electrical Safety and Grounding Tests

  • Verify that all electrical components are properly grounded and shielded

5. Temperature Control (if applicable)

  • For refrigerated centrifuges, test cooling function to ensure temperature stability within set ranges
  • Check refrigerant levels and inspect for compressor noise or failure

6. Final Quality Assurance Checklist

  • Conduct a full run-through using the user interface
  • Document all test results

Repair and Refurbishment Protocol for Used Laboratory Centrifuges

Certified Quality from American Instrument Exchange

At American Instrument Exchange, we follow a meticulous repair and refurbishment protocol to ensure that every used laboratory centrifuge we sell. We strive for reliable performance and long-term durability—providing labs with exceptional value on high-quality pre-owned centrifuges.

Why Choose a Refurbished Centrifuge from American Instrument Exchange?

  • Fully tested
  • Backed by warranty and performance guarantee
  • Cost-effective alternative to new lab equipment
  • Environmentally responsible through equipment reuse
  • Supported by expert technicians with decades of experience

Step-by-Step Refurbishment Protocol

Every used centrifuge at American Instrument Exchange goes through the following comprehensive repair and refurbishment process:

1. Initial Intake & Inspection

  • Our technicians perform a complete visual and mechanical inspection
  • Evaluation of hinges, seals, gaskets, and electrical components
  • Any physical damage, missing parts, or wear is documented for repair

2. Cleaning and decontamination

  • Full internal and external cleaning using non-abrasive, disinfectant-safe products
  • Biological or chemical residue is decontaminated/cleaned

3. Mechanical & Electrical Repairs

  • Damaged or worn parts (e.g., drive motors, lid latches, rotor buckets) are replaced or repaired
  • Electrical components, sensors, and fuses are tested and replaced as needed
  • Wiring is inspected for integrity and safety per industry standards

4. Rotor & Accessory Evaluation

  • All rotors, buckets, and adapters are inspected for cracks, corrosion, and balance
  • Non-conforming components are replaced with OEM or equivalent alternatives

5. Performance Testing

  • Rotor speed (RPM), acceleration, and deceleration are verified
  • Refrigerated centrifuges undergo temperature stability testing across set ranges

6. Safety System Verification

  • Lid lock and interlock systems are tested for proper function
  • Emergency stop and imbalance detection systems are verified
  • Electrical safety and grounding tests are conducted

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the industry, American Instrument Exchange is a trusted name for refurbished lab equipment. Our centrifuge refurbishment protocol reflects our commitment to quality, safety, and customer satisfaction.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.