Many laboratories need dependable frozen storage for reagents, standards, biological samples, and research materials without the expense or complexity of an ultra-low freezer. The Fisher Laboratory Freezer 13-986-247 provides reliable -12°C to -20°C storage in a spacious upright cabinet, making it an excellent solution for general laboratory applications where consistent subzero temperatures are essential. Its large interior, simple manual defrost design, and durable construction make it well suited for laboratories that value reliability and straightforward operation.
The Fisher 13-986-247 is an excellent choice for biotechnology companies, pharmaceutical manufacturers, hospitals, universities, environmental laboratories, quality control facilities, and industrial research laboratories storing enzymes, reagents, biological specimens, standards, and laboratory chemicals requiring frozen storage. Many laboratories also choose this style of freezer because manual-defrost cabinets eliminate the periodic warming cycles associated with automatic defrost systems, helping maintain more consistent sample temperatures.
Many laboratories pair a general-purpose laboratory freezer like the 13-986-247 with laboratory refrigerators for refrigerated materials, ultra-low freezers for long-term preservation, biosafety cabinets for sterile sample preparation, and centrifuges to create a complete laboratory cold storage workflow.
Approximately 20 cu. ft. capacity
Temperature range: -12°C to -20°C
Upright manual-defrost cabinet
Four fixed storage shelves
Mechanical temperature control
Solid insulated door
Heavy-duty laboratory construction
Manual defrost for stable storage temperatures
115V operation
Refurbished and performance tested by American Instrument Exchange
90-day warranty included
The Fisher 13-986-247 is designed for laboratories that require dependable frozen storage with minimal complexity. Unlike ultra-low freezers that operate at -80°C, this freezer is intended for everyday laboratory materials that require conventional frozen storage while offering lower operating costs and easier maintenance.
Its manual-defrost refrigeration system is particularly attractive for laboratories storing temperature-sensitive materials because it avoids the periodic warming cycles common in frost-free commercial freezers. The large upright cabinet provides organized storage using fixed shelves, allowing researchers to separate samples by project, department, or application while maintaining easy access throughout the workday.
The Fisher 13-986-247 is commonly used for storing:
Laboratory reagents
Biological samples
Enzymes
Protein samples
Research chemicals
Cell culture reagents
Diagnostic kits
Calibration standards
Environmental samples
Quality control materials
This freezer is well suited for:
Biotechnology companies
Pharmaceutical manufacturers
Academic research laboratories
Clinical laboratories
Hospitals
Environmental laboratories
Industrial research facilities
Quality control laboratories
Laboratories requiring dependable frozen storage without the expense of an ultra-low freezer will appreciate its combination of capacity, reliability, and simple operation.
Many research laboratories intentionally select manual-defrost freezers because they maintain more stable cabinet temperatures than automatic-defrost systems. Automatic defrost cycles periodically warm the evaporator to remove frost, while manual-defrost units avoid these temperature fluctuations, making them well suited for laboratories storing sensitive reagents, enzymes, proteins, and biological samples.
The Fisher 13-986-247 is commonly used to preserve:
Research reagents
Antibodies
Enzymes
Proteins
Laboratory chemicals
Cell culture media
Diagnostic materials
Biological specimens
Quality control samples
20 cu. ft.
-12°C to -20°C
Powder-coated steel exterior
Insulated cabinet
Solid insulated door
Four fixed storage shelves
Manual defrost
Mechanical temperature control
115V, 60 Hz
NEMA 5-15 plug
36" W × 32" D × 73" H
20" W × 27" D × 57" H
Approximately 200 lbs. (shipping)
Operating costs are lower than those of ultra-low freezers because the refrigeration system maintains conventional laboratory freezer temperatures rather than -80°C. Maintaining adequate condenser ventilation, periodically cleaning the condenser, and manually defrosting the cabinet when frost accumulates will help maximize refrigeration efficiency and extend equipment life.
Specifications compiled from Fisher manufacturer literature and American Instrument Exchange product information.
Every Fisher Laboratory Freezer 13-986-247 received by American Instrument Exchange undergoes a comprehensive inspection and temperature performance evaluation before shipment. Our technicians verify refrigeration performance, thermostat operation, compressor function, door gasket integrity, and cabinet condition. Temperature stability is confirmed using calibrated instrumentation, worn components are replaced as needed, and each freezer is thoroughly cleaned before delivery.
Laboratories building complete cold storage systems frequently purchase laboratory refrigerators, ultra-low freezers, biosafety cabinets, centrifuges, and cryogenic storage systems from American Instrument Exchange.
The Fisher 13-986-247 ships by freight from American Instrument Exchange. Before installation, laboratories should verify doorway clearances, available floor space, electrical service, and adequate ventilation around the condenser. Allow the cabinet to reach operating temperature before loading valuable samples to ensure optimal performance.
Is the Fisher 13-986-247 an ultra-low freezer?
No. This is a general-purpose laboratory freezer designed to operate between -12°C and -20°C, making it ideal for routine laboratory frozen storage.
Why would I choose a manual-defrost freezer?
Manual-defrost freezers avoid the warming cycles associated with automatic defrost systems, helping maintain more consistent storage temperatures for temperature-sensitive laboratory materials.
What types of materials are commonly stored in this freezer?
The freezer is commonly used for enzymes, proteins, laboratory reagents, biological specimens, research chemicals, diagnostic materials, and quality control samples.
How is the Fisher 13-986-247 tested before shipment?
Every refurbished Fisher 13-986-247 is inspected and temperature tested by American Instrument Exchange technicians to verify refrigeration performance, thermostat operation, compressor function, and overall cabinet condition before shipment.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.