Forma 3033 CO2 SteriCult 200

Sorry, this unit has just been sold. Please contact us for alternatives.

Item: 3172 INC

FULLY TESTED & WARRANTIED*


All products ship from our 30,000 sq. ft. Haverhill, MA warehouse


Contact Us

Call 978-521-2221
to request information & pricing for item 3172 INC

90-Day Warranty

American Instrument Exchange
Contact us for all your used lab equipment needs

1023 Western Ave.
Haverhill, MA 01832

Phone: 978-521-2221
Fax: 978-521-8822

Email: info@americaninstrument.com

Shipping Policy

Thermo Stericult 3033

  • Single 10.5 cubic foot chamber
  • Temperature range: ambient +4°C to 45°C
  • CO2 range: 0 – 20%
  • 90 day warranty

The Thermo Forma Steri-Cult CO2 3033 Incubator uses HEPA filtered, vertical laminar airflow techniques and a filtered external water supply to minimize contamination and desiccation of cultures. The Thermo Forma 3033 has an innovative humidity supply system located outside the chamber that provides rapid RH recovery. The humidity system is not a vapor generator and has no immersible heater to burn out or to cause scaling. Water reservoir for the humidity system is easily filled by way of a port on the outside of the unit. Humidity control is user-selectable above ambient for total control over chamber conditions.

Most of our equipment is used and reconditioned. We test CO2 incubators using a calibrated digital chart recorder to verify the accuracy of temperature controls and readouts, as well as using a Fyrite indicator to measure CO2 levels in the chamber. We replace any hardware or parts as is necessary and clean all incubators thoroughly prior to shipment.

SPECIFICATIONS

Temperature

Control . . . . . . . . . . . . . . . ±0.1C

Range . . . . . . . . . . . . . . . . 4C above ambient to 45C (113F)

Sensor . . . . . . . . . . . . . . . . Platinum

Controller . . . . . . . . . . . . . Microprocessor

Setpoint . . . . . . . . . . . . . . . Digital

Display . . . . . . . . . . . . . . . Digital LCD

Readability . . . . . . . . . . . . 0.1C

Setability . . . . . . . . . . . . . . 0.1C

Uniformity. . . . . . . . . . . . . ±0.3C @ 37C (98.6F)

Temperature Alarm

Sensor . . . . . . . . . . . . . . . . Platinum

Controller . . . . . . . . . . . . . Independent analog (high and low alarm)

Setpoint . . . . . . . . . . . . . . . Digital with screwdriver adjust

Display . . . . . . . . . . . . . . . Audible/visual

Readability . . . . . . . . . . . . 0.1C

Setability . . . . . . . . . . . . . . 0.1C

CO2

Control . . . . . . . . . . . . . . . Better than ±0.1%

CO2 Range. . . . . . . . . . . . . 0-20%

Calibration. . . . . . . . . . . . . Auto-zero

Inlet Pressure. . . . . . . . . . . 10 PSIG (0.7 bar)

Filter . . . . . . . . . . . . . . . . . 0.2 micron, disposable

Sensor . . . . . . . . . . . . . . . . IR

Controller . . . . . . . . . . . . . Microprocessor

Setpoint . . . . . . . . . . . . . . . Digital

Display . . . . . . . . . . . . . . . Digital LCD

Readability . . . . . . . . . . . . 0.1%

Setability . . . . . . . . . . . . . . 0.1%

Alarm Differential . . . . . . . ±1.0% (nominal) for approximately and Delay 30 minutes

Controlled RH

RH . . . . . . . . . . . . . . . . . . Ambient to >95% RH @37C (98.6F)

Humidity Control . . . . . . . ±2.0%

Sensor . . . . . . . . . . . . . . . . Platinum

Controller . . . . . . . . . . . . . Microprocessor

Setpoint . . . . . . . . . . . . . . . Digital

Display . . . . . . . . . . . . . . . Digital LCD

Readability . . . . . . . . . . . . 0.1%

Setability . . . . . . . . . . . . . . 0.1%

Humidity Reservoir . . . . . . 1.0 gal. (3.8 liters)