Inotech Steri 250 Dry Bead Sterilizer

Fully Tested & Warrantied*
Brand : Almedica
Product Code : SKU 0549B A-CLAVE
Style: $250.00

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Inotech Steri 250 Dry Glass Bead Sterilizer

Laboratories performing micro-dissection, animal research, microbiology, tissue preparation, and other procedures involving reusable metal instruments often need a fast way to treat instrument tips between procedures. The Inotech Steri 250 Dry Glass Bead Sterilizer provides rapid high-temperature treatment in a compact benchtop system, allowing compatible metal instruments to be processed without an open flame, chemical disinfectant bath, or conventional autoclave cycle.

Available from American Instrument Exchange, the Inotech Steri 250 maintains a bath of heated glass beads at approximately 250°C (482°F). Clean, dry metal instruments are inserted into the heated bead well, with manufacturer instructions specifying treatment for at least 10 seconds. Its compact footprint, deep instrument well, and simple operation make the Steri 250 particularly useful for laboratories working with forceps, scissors, tweezers, blades, spatulas, and other small to medium-sized heat-resistant instruments.

This used Inotech Steri 250 has been reconditioned, inspected, and tested by American Instrument Exchange and includes a 90-day warranty.

Inotech Steri 250 Key Features

  • Compact benchtop dry glass bead sterilizer

  • Operating temperature of approximately 250°C (482°F)

  • Rapid treatment of clean, dry metal instruments in approximately 10 seconds

  • 1.6-inch diameter × 3.2-inch deep stainless steel bead well

  • Suitable for small and medium-sized metal instruments

  • Chrome-nickel steel well and lid

  • Rust-resistant aluminum exterior housing

  • Approximately 18-minute heat-up time to operating temperature

  • No plumbing, external steam, gases, or open flame required

  • Small footprint for placement near laboratory procedure areas

  • Reconditioned, inspected, and tested by American Instrument Exchange

  • Includes a 90-day warranty

Overview

The Inotech Steri 250 is a compact dry heat glass bead sterilizer designed for rapid treatment of small and medium-sized metal laboratory instruments. Rather than processing an entire load with pressurized steam, the Steri 250 maintains a stainless steel container filled with glass beads at approximately 250°C. Heat stored within the beads transfers rapidly to the portion of a compatible instrument inserted into the well.

The Steri 250 is especially useful for workflows in which forceps, scissors, tweezers, blades, spatulas, or similar instruments may need to be treated repeatedly during the course of laboratory work. Once the unit reaches operating temperature, clean and dry instruments can be inserted directly into the glass beads rather than waiting for a conventional steam sterilizer cycle.

Compared with smaller bead sterilizers intended primarily for fine instrument tips, the Steri 250 provides a relatively deep 8 cm (3.2-inch) treatment chamber. This allows users to insert a larger portion of many small and medium-length instruments into the heated beads while retaining the compact footprint expected from a benchtop unit.

The system is intentionally simple. The glass beads remain heated as long as the sterilizer is switched on, providing an immediately available treatment station for repeated procedures. No water supply, drainage, compressed gas, or external steam connection is required.

This makes the Steri 250 particularly useful as a point-of-use complement to a laboratory's primary sterilization equipment. An autoclave may still be used for full instrument sets, glassware, media, waste, and other compatible loads, while the bead sterilizer provides rapid treatment of appropriate metal instruments during laboratory procedures.

Inotech Steri 250 Common Applications

  • Treatment of laboratory forceps and tweezers

  • Micro-dissection instrument processing

  • Treatment of small scissors and blades

  • Animal research and surgical procedure support

  • Tissue preparation and manipulation

  • Neuroscience and physiology research

  • Treatment of spatulas and other small metal tools

  • Microbiology laboratory workflows

  • Academic research and teaching laboratories

  • Rapid point-of-use treatment of compatible metal instruments

Inotech Steri 250 Ideal Laboratory Environments

The Inotech Steri 250 is particularly well suited for research environments in which small metal instruments are used repeatedly throughout a procedure. Animal research facilities, neuroscience laboratories, physiology departments, anatomy laboratories, and tissue-preparation areas may benefit from keeping a bead sterilizer close to the procedural workspace.

Micro-dissection work often requires fine forceps, scissors, blades, and other instruments that may need repeated treatment without substantially interrupting the experiment. A glass bead sterilizer provides a convenient point-of-use option because the unit remains at operating temperature after warm-up and is immediately available when another instrument must be processed.

The Steri 250 can also be useful in microbiology and general research laboratories that work with small metal tools but do not want an open flame at the bench. Eliminating Bunsen burners or alcohol flames can be advantageous in areas containing flammable materials or where open flames are otherwise discouraged.

Because of its very small footprint, the Steri 250 can be positioned near microscopes, animal procedure stations, tissue-processing areas, or other workspaces without consuming the amount of bench space required by a conventional benchtop autoclave.

Dry Glass Bead Heat Treatment

The Inotech Steri 250 uses high-temperature glass beads as a heat-transfer medium. After approximately 18 minutes of warm-up, the bead container reaches roughly 250°C (482°F) and maintains that temperature while the unit remains switched on.

Clean, dry metal instruments are inserted into the heated glass beads as deeply as appropriate. Manufacturer instructions specify treatment for at least 10 seconds for compatible instruments. The surrounding glass beads provide broad contact with the inserted metal surface, allowing heat to transfer rapidly to the instrument.

This process differs significantly from conventional steam autoclaving. An autoclave exposes an entire load to saturated steam under controlled temperature, pressure, and time conditions. The Steri 250 applies localized dry heat only to the portion of an instrument placed within the heated beads.

Although equipment of this type is commonly marketed as a "glass bead sterilizer," laboratories should follow their own institutional procedures and applicable regulations when determining whether bead treatment satisfies a particular sterilization or decontamination requirement. A short bead-treatment cycle should not automatically be considered interchangeable with a validated steam autoclave cycle.

Sterilizing Well Capacity and Laboratory Workflow

The Steri 250 uses a cylindrical stainless steel bead container measuring approximately 4 cm in diameter by 8 cm deep, or about 1.6 inches in diameter by 3.2 inches deep. The chamber is designed for insertion of individual small or medium-sized metal instruments rather than batches of laboratory supplies.

The deeper well distinguishes the Steri 250 from very small micro-instrument bead sterilizers. Forceps, scissors, blades, tweezers, and other compatible instruments can be inserted several centimeters into the heated beads, allowing the working portion of the instrument to receive direct high-temperature exposure.

Once operating temperature is reached, multiple instruments can be processed sequentially without waiting for the unit to reheat between each item under normal use. This can make the Steri 250 useful in repetitive research workflows where instrument turnaround needs to occur in seconds.

The unit is not designed for glassware, culture media, liquids, wrapped instrument packs, biohazardous waste, plastic components, or other materials typically handled by a steam autoclave. For most laboratories, a dry bead sterilizer therefore serves as supplemental sterilization or decontamination equipment rather than replacing the facility's primary autoclave.

Choosing the Right Laboratory Sterilization Equipment

The Inotech Steri 250 is best suited for laboratories whose primary requirement is rapid treatment of small and medium-sized heat-resistant metal instruments. Its 3.2-inch-deep well provides useful instrument insertion depth while the compact exterior dimensions make it easy to integrate into an existing procedure station.

Laboratories should consider both instrument dimensions and materials before selecting a glass bead sterilizer. Only the portion of the instrument placed into the beads is exposed directly to the treatment temperature, and the instrument must be capable of tolerating approximately 250°C without damage.

Heat-sensitive handles, plastic components, coatings, adhesives, electronic components, and other temperature-sensitive materials may make some instruments unsuitable for bead treatment. Instruments should also be clean and dry before being placed into the glass beads.

A conventional laboratory autoclave remains the more appropriate solution when entire instrument sets, culture media, liquids, glassware, waste, or larger laboratory loads must be sterilized. A bead sterilizer is instead optimized for rapid point-of-use treatment of compatible instruments.

For laboratories already equipped with an autoclave, the Steri 250 can complement centralized sterilization by providing convenient instrument treatment directly at the workbench. American Instrument Exchange can help customers compare glass bead sterilizers, dry sterilizers, and laboratory autoclaves based on the materials and workflows they need to support.

Inotech Steri 250 Key Specifications

Specification Details
Manufacturer / Brand Inotech / Steri
Model Steri 250
Equipment Type Dry glass bead sterilizer
Heating Method Electrically heated glass bead bath
Operating Temperature 250°C (482°F)
Temperature Stability Approximately ±5%
Typical Treatment Time At least 10 seconds for compatible clean, dry instruments
Heat-Up Time Approximately 18 minutes
Sterilizing Well Dimensions 4 cm diameter × 8 cm deep (1.6 in diameter × 3.2 in deep)
Exterior Dimensions Approximately 12.5 cm W × 14 cm D × 14.5 cm H (4.9 × 5.5 × 5.7 in)
Well Material Rust-resistant chrome-nickel/stainless steel
Lid Material Rust-resistant chrome-nickel/stainless steel
Exterior Case Material Rust-resistant aluminum
Glass Bead Capacity Approximately 150 g (5.3 oz)
Electrical Configurations Manufactured in 110/120 V and 220/240 V versions; verify individual unit
Power Consumption Approximately 90 W
Plumbing Requirements None
External Steam Required No
Net Weight Approximately 1.4 kg (3.1 lb)
Installation Type Benchtop
Condition Used / reconditioned
Warranty 90 days

Specifications have been compiled from American Instrument Exchange product information and available Steri 250 technical documentation. Individual units were manufactured in different electrical configurations, so voltage, accessories, glass beads, and other specifications should be confirmed against the equipment data plate and available unit before purchase.

Installation and Operating Requirements

The Inotech Steri 250 requires very little installation compared with a conventional laboratory autoclave. The system needs a stable benchtop location and an electrical outlet matching the voltage shown on the individual unit's data plate. It does not require plumbing, drainage, an external steam connection, compressed air, or gas service.

The sterilizer should be filled only with clean, dry glass beads appropriate for the equipment. Published instructions specify filling the container to approximately 2 mm below the rim. Liquids or other materials should not be placed into the bead container.

After the system is switched on, approximately 18 minutes should be allowed for the bead bath to reach its normal operating temperature of 250°C. Because the beads, well, and surrounding components become extremely hot, operators should avoid direct contact and follow appropriate burn-prevention procedures.

Instruments should be cleaned and dried before treatment. Residual biological material may interfere with heat transfer and effective processing, while introducing moisture or contamination into the bead bath may adversely affect operation.

Why Buy a Used Inotech Steri 250 from American Instrument Exchange?

A used Inotech Steri 250 provides laboratories with an economical way to add rapid point-of-use instrument treatment without purchasing another full-size sterilization system. The simple heating design, compact footprint, and lack of plumbing requirements make dry bead sterilizers relatively easy to integrate into existing research spaces.

American Instrument Exchange reconditions, inspects, and tests used laboratory equipment before shipment to verify proper operation. This Steri 250 includes a 90-day warranty.

American Instrument Exchange also supplies conventional laboratory autoclaves and other sterilization equipment for facilities that need to process larger loads, as well as complementary equipment including biosafety cabinets, microscopes, incubators, laboratory ovens, centrifuges, refrigerators, freezers, and other research instruments.

Customers can contact American Instrument Exchange to confirm the available Steri 250's condition, electrical configuration, accessories, glass beads, shipping availability, and suitability for their intended application.

Frequently Asked Questions

What is the operating temperature of the Inotech Steri 250?

The Steri 250 maintains its glass bead bath at approximately 250°C, or 482°F, once the unit has reached operating temperature.

How long should instruments remain in the Steri 250?

Published operating instructions specify inserting compatible clean and dry instruments into the heated beads for at least 10 seconds. Laboratories should follow their own approved procedures for the particular instruments and application.

What size instruments can the Steri 250 accommodate?

The bead well measures approximately 4 cm in diameter by 8 cm deep, or 1.6 inches in diameter by 3.2 inches deep. It is intended primarily for small and medium-sized metal instruments such as forceps, tweezers, scissors, blades, and spatulas.

How long does the Steri 250 take to heat up?

The system typically requires approximately 18 minutes to reach its normal operating temperature of 250°C.

Is the Steri 250 the same as an autoclave?

No. An autoclave uses pressurized saturated steam to process entire loads. The Steri 250 uses localized high-temperature dry heat from glass beads to treat the portion of a compatible instrument inserted into the well.

Can the Steri 250 replace a laboratory autoclave?

Not for most laboratories. A steam autoclave is generally required for media, glassware, liquids, waste, wrapped instruments, and larger loads. The Steri 250 is better suited as a complementary system for rapid point-of-use treatment of small metal instruments.

Can plastic instruments be placed in the Steri 250?

Only materials capable of tolerating approximately 250°C should be placed into the heated bead bath. Heat-sensitive plastics, coatings, adhesives, and other components may be damaged and should not be used unless their compatibility has been confirmed.

What are the exterior dimensions of the Steri 250?

The unit measures approximately 4.9 inches wide × 5.5 inches deep × 5.7 inches high, making it small enough for placement near many laboratory procedure stations.

Does the Inotech Steri 250 require plumbing?

No. The unit is electrically heated and does not require water, drainage, external steam, or other plumbing connections.

What electrical service does the Steri 250 require?

The Steri 250 was manufactured in both 110/120 V and 220/240 V versions. Customers should confirm the electrical data plate on the specific unit offered by American Instrument Exchange before purchase.

Does this Inotech Steri 250 include a warranty?

Unless otherwise specified, this reconditioned Steri 250 includes a 90-day warranty from American Instrument Exchange.

Does American Instrument Exchange also sell steam autoclaves?

Yes. American Instrument Exchange supplies used and refurbished laboratory autoclaves as well as new Tuttnauer autoclaves for laboratories requiring steam sterilization of glassware, media, instruments, waste, liquids, and other compatible materials.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.