Inotech Steri 250 Dry Bead Sterilizer
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Laboratories performing micro-dissection, animal research, microbiology, tissue preparation, and other procedures involving reusable metal instruments often need a fast way to treat instrument tips between procedures. The Inotech Steri 250 Dry Glass Bead Sterilizer provides rapid high-temperature treatment in a compact benchtop system, allowing compatible metal instruments to be processed without an open flame, chemical disinfectant bath, or conventional autoclave cycle.
Available from American Instrument Exchange, the Inotech Steri 250 maintains a bath of heated glass beads at approximately 250°C (482°F). Clean, dry metal instruments are inserted into the heated bead well, with manufacturer instructions specifying treatment for at least 10 seconds. Its compact footprint, deep instrument well, and simple operation make the Steri 250 particularly useful for laboratories working with forceps, scissors, tweezers, blades, spatulas, and other small to medium-sized heat-resistant instruments.
This used Inotech Steri 250 has been reconditioned, inspected, and tested by American Instrument Exchange and includes a 90-day warranty.
Compact benchtop dry glass bead sterilizer
Operating temperature of approximately 250°C (482°F)
Rapid treatment of clean, dry metal instruments in approximately 10 seconds
1.6-inch diameter × 3.2-inch deep stainless steel bead well
Suitable for small and medium-sized metal instruments
Chrome-nickel steel well and lid
Rust-resistant aluminum exterior housing
Approximately 18-minute heat-up time to operating temperature
No plumbing, external steam, gases, or open flame required
Small footprint for placement near laboratory procedure areas
Reconditioned, inspected, and tested by American Instrument Exchange
Includes a 90-day warranty
The Inotech Steri 250 is a compact dry heat glass bead sterilizer designed for rapid treatment of small and medium-sized metal laboratory instruments. Rather than processing an entire load with pressurized steam, the Steri 250 maintains a stainless steel container filled with glass beads at approximately 250°C. Heat stored within the beads transfers rapidly to the portion of a compatible instrument inserted into the well.
The Steri 250 is especially useful for workflows in which forceps, scissors, tweezers, blades, spatulas, or similar instruments may need to be treated repeatedly during the course of laboratory work. Once the unit reaches operating temperature, clean and dry instruments can be inserted directly into the glass beads rather than waiting for a conventional steam sterilizer cycle.
Compared with smaller bead sterilizers intended primarily for fine instrument tips, the Steri 250 provides a relatively deep 8 cm (3.2-inch) treatment chamber. This allows users to insert a larger portion of many small and medium-length instruments into the heated beads while retaining the compact footprint expected from a benchtop unit.
The system is intentionally simple. The glass beads remain heated as long as the sterilizer is switched on, providing an immediately available treatment station for repeated procedures. No water supply, drainage, compressed gas, or external steam connection is required.
This makes the Steri 250 particularly useful as a point-of-use complement to a laboratory's primary sterilization equipment. An autoclave may still be used for full instrument sets, glassware, media, waste, and other compatible loads, while the bead sterilizer provides rapid treatment of appropriate metal instruments during laboratory procedures.
Treatment of laboratory forceps and tweezers
Micro-dissection instrument processing
Treatment of small scissors and blades
Animal research and surgical procedure support
Tissue preparation and manipulation
Neuroscience and physiology research
Treatment of spatulas and other small metal tools
Microbiology laboratory workflows
Academic research and teaching laboratories
Rapid point-of-use treatment of compatible metal instruments
The Inotech Steri 250 is particularly well suited for research environments in which small metal instruments are used repeatedly throughout a procedure. Animal research facilities, neuroscience laboratories, physiology departments, anatomy laboratories, and tissue-preparation areas may benefit from keeping a bead sterilizer close to the procedural workspace.
Micro-dissection work often requires fine forceps, scissors, blades, and other instruments that may need repeated treatment without substantially interrupting the experiment. A glass bead sterilizer provides a convenient point-of-use option because the unit remains at operating temperature after warm-up and is immediately available when another instrument must be processed.
The Steri 250 can also be useful in microbiology and general research laboratories that work with small metal tools but do not want an open flame at the bench. Eliminating Bunsen burners or alcohol flames can be advantageous in areas containing flammable materials or where open flames are otherwise discouraged.
Because of its very small footprint, the Steri 250 can be positioned near microscopes, animal procedure stations, tissue-processing areas, or other workspaces without consuming the amount of bench space required by a conventional benchtop autoclave.
The Inotech Steri 250 uses high-temperature glass beads as a heat-transfer medium. After approximately 18 minutes of warm-up, the bead container reaches roughly 250°C (482°F) and maintains that temperature while the unit remains switched on.
Clean, dry metal instruments are inserted into the heated glass beads as deeply as appropriate. Manufacturer instructions specify treatment for at least 10 seconds for compatible instruments. The surrounding glass beads provide broad contact with the inserted metal surface, allowing heat to transfer rapidly to the instrument.
This process differs significantly from conventional steam autoclaving. An autoclave exposes an entire load to saturated steam under controlled temperature, pressure, and time conditions. The Steri 250 applies localized dry heat only to the portion of an instrument placed within the heated beads.
Although equipment of this type is commonly marketed as a "glass bead sterilizer," laboratories should follow their own institutional procedures and applicable regulations when determining whether bead treatment satisfies a particular sterilization or decontamination requirement. A short bead-treatment cycle should not automatically be considered interchangeable with a validated steam autoclave cycle.
The Steri 250 uses a cylindrical stainless steel bead container measuring approximately 4 cm in diameter by 8 cm deep, or about 1.6 inches in diameter by 3.2 inches deep. The chamber is designed for insertion of individual small or medium-sized metal instruments rather than batches of laboratory supplies.
The deeper well distinguishes the Steri 250 from very small micro-instrument bead sterilizers. Forceps, scissors, blades, tweezers, and other compatible instruments can be inserted several centimeters into the heated beads, allowing the working portion of the instrument to receive direct high-temperature exposure.
Once operating temperature is reached, multiple instruments can be processed sequentially without waiting for the unit to reheat between each item under normal use. This can make the Steri 250 useful in repetitive research workflows where instrument turnaround needs to occur in seconds.
The unit is not designed for glassware, culture media, liquids, wrapped instrument packs, biohazardous waste, plastic components, or other materials typically handled by a steam autoclave. For most laboratories, a dry bead sterilizer therefore serves as supplemental sterilization or decontamination equipment rather than replacing the facility's primary autoclave.
The Inotech Steri 250 is best suited for laboratories whose primary requirement is rapid treatment of small and medium-sized heat-resistant metal instruments. Its 3.2-inch-deep well provides useful instrument insertion depth while the compact exterior dimensions make it easy to integrate into an existing procedure station.
Laboratories should consider both instrument dimensions and materials before selecting a glass bead sterilizer. Only the portion of the instrument placed into the beads is exposed directly to the treatment temperature, and the instrument must be capable of tolerating approximately 250°C without damage.
Heat-sensitive handles, plastic components, coatings, adhesives, electronic components, and other temperature-sensitive materials may make some instruments unsuitable for bead treatment. Instruments should also be clean and dry before being placed into the glass beads.
A conventional laboratory autoclave remains the more appropriate solution when entire instrument sets, culture media, liquids, glassware, waste, or larger laboratory loads must be sterilized. A bead sterilizer is instead optimized for rapid point-of-use treatment of compatible instruments.
For laboratories already equipped with an autoclave, the Steri 250 can complement centralized sterilization by providing convenient instrument treatment directly at the workbench. American Instrument Exchange can help customers compare glass bead sterilizers, dry sterilizers, and laboratory autoclaves based on the materials and workflows they need to support.
| Specification | Details |
|---|---|
| Manufacturer / Brand | Inotech / Steri |
| Model | Steri 250 |
| Equipment Type | Dry glass bead sterilizer |
| Heating Method | Electrically heated glass bead bath |
| Operating Temperature | 250°C (482°F) |
| Temperature Stability | Approximately ±5% |
| Typical Treatment Time | At least 10 seconds for compatible clean, dry instruments |
| Heat-Up Time | Approximately 18 minutes |
| Sterilizing Well Dimensions | 4 cm diameter × 8 cm deep (1.6 in diameter × 3.2 in deep) |
| Exterior Dimensions | Approximately 12.5 cm W × 14 cm D × 14.5 cm H (4.9 × 5.5 × 5.7 in) |
| Well Material | Rust-resistant chrome-nickel/stainless steel |
| Lid Material | Rust-resistant chrome-nickel/stainless steel |
| Exterior Case Material | Rust-resistant aluminum |
| Glass Bead Capacity | Approximately 150 g (5.3 oz) |
| Electrical Configurations | Manufactured in 110/120 V and 220/240 V versions; verify individual unit |
| Power Consumption | Approximately 90 W |
| Plumbing Requirements | None |
| External Steam Required | No |
| Net Weight | Approximately 1.4 kg (3.1 lb) |
| Installation Type | Benchtop |
| Condition | Used / reconditioned |
| Warranty | 90 days |
Specifications have been compiled from American Instrument Exchange product information and available Steri 250 technical documentation. Individual units were manufactured in different electrical configurations, so voltage, accessories, glass beads, and other specifications should be confirmed against the equipment data plate and available unit before purchase.
The Inotech Steri 250 requires very little installation compared with a conventional laboratory autoclave. The system needs a stable benchtop location and an electrical outlet matching the voltage shown on the individual unit's data plate. It does not require plumbing, drainage, an external steam connection, compressed air, or gas service.
The sterilizer should be filled only with clean, dry glass beads appropriate for the equipment. Published instructions specify filling the container to approximately 2 mm below the rim. Liquids or other materials should not be placed into the bead container.
After the system is switched on, approximately 18 minutes should be allowed for the bead bath to reach its normal operating temperature of 250°C. Because the beads, well, and surrounding components become extremely hot, operators should avoid direct contact and follow appropriate burn-prevention procedures.
Instruments should be cleaned and dried before treatment. Residual biological material may interfere with heat transfer and effective processing, while introducing moisture or contamination into the bead bath may adversely affect operation.
A used Inotech Steri 250 provides laboratories with an economical way to add rapid point-of-use instrument treatment without purchasing another full-size sterilization system. The simple heating design, compact footprint, and lack of plumbing requirements make dry bead sterilizers relatively easy to integrate into existing research spaces.
American Instrument Exchange reconditions, inspects, and tests used laboratory equipment before shipment to verify proper operation. This Steri 250 includes a 90-day warranty.
American Instrument Exchange also supplies conventional laboratory autoclaves and other sterilization equipment for facilities that need to process larger loads, as well as complementary equipment including biosafety cabinets, microscopes, incubators, laboratory ovens, centrifuges, refrigerators, freezers, and other research instruments.
Customers can contact American Instrument Exchange to confirm the available Steri 250's condition, electrical configuration, accessories, glass beads, shipping availability, and suitability for their intended application.
The Steri 250 maintains its glass bead bath at approximately 250°C, or 482°F, once the unit has reached operating temperature.
Published operating instructions specify inserting compatible clean and dry instruments into the heated beads for at least 10 seconds. Laboratories should follow their own approved procedures for the particular instruments and application.
The bead well measures approximately 4 cm in diameter by 8 cm deep, or 1.6 inches in diameter by 3.2 inches deep. It is intended primarily for small and medium-sized metal instruments such as forceps, tweezers, scissors, blades, and spatulas.
The system typically requires approximately 18 minutes to reach its normal operating temperature of 250°C.
No. An autoclave uses pressurized saturated steam to process entire loads. The Steri 250 uses localized high-temperature dry heat from glass beads to treat the portion of a compatible instrument inserted into the well.
Not for most laboratories. A steam autoclave is generally required for media, glassware, liquids, waste, wrapped instruments, and larger loads. The Steri 250 is better suited as a complementary system for rapid point-of-use treatment of small metal instruments.
Only materials capable of tolerating approximately 250°C should be placed into the heated bead bath. Heat-sensitive plastics, coatings, adhesives, and other components may be damaged and should not be used unless their compatibility has been confirmed.
The unit measures approximately 4.9 inches wide × 5.5 inches deep × 5.7 inches high, making it small enough for placement near many laboratory procedure stations.
No. The unit is electrically heated and does not require water, drainage, external steam, or other plumbing connections.
The Steri 250 was manufactured in both 110/120 V and 220/240 V versions. Customers should confirm the electrical data plate on the specific unit offered by American Instrument Exchange before purchase.
Unless otherwise specified, this reconditioned Steri 250 includes a 90-day warranty from American Instrument Exchange.
Yes. American Instrument Exchange supplies used and refurbished laboratory autoclaves as well as new Tuttnauer autoclaves for laboratories requiring steam sterilization of glassware, media, instruments, waste, liquids, and other compatible materials.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.