Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Jeio Tech ISF-7100 incubator shaker

Fully Tested & Warrantied*
Brand : Jeio
Product Code : SKU 4814AA SHAKER
Title: $5600.00

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Jeio Tech ISF-7100 Incubated Orbital Shaker

The Jeio Tech ISF-7100 is a high-capacity incubated orbital shaker designed for microbial culture, protein expression, cell culture research, extraction, solubility studies, and other laboratory applications requiring controlled temperature and continuous agitation. Combining a large shaking platform with temperatures from ambient +5°C to 80°C and orbital speeds from 30 to 500 rpm, the ISF-7100 provides a controlled environment for demanding culture and mixing applications.

Available used and refurbished from American Instrument Exchange, this Jeio Tech ISF-7100 is inspected, cleaned, and tested prior to shipment. AIE verifies both shaking operation and temperature performance and includes a 90-day warranty.

Key Features

  • High-capacity incubated orbital shaker

  • Temperature range from ambient +5°C to 80°C

  • 30–500 rpm shaking range

  • 25.4 mm / 1-inch orbital motion

  • Large 29.7 × 20.5-inch platform

  • Microprocessor PID temperature control

  • Brushless motor and triple-cam drive system

  • Touchscreen LCD control interface

  • Timer adjustable from 1 minute to 999 hours, 59 minutes

  • Viewing window and interior LED illumination

  • Smooth-start and smooth-stop operation

  • Automatic restart following a power interruption

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Jeio Tech ISF-7100 combines incubation and orbital shaking within a large floor-standing system, eliminating the need to place a separate shaker inside an environmental chamber. The enclosed chamber maintains elevated temperatures while the orbital platform provides controlled agitation for flasks and other laboratory vessels.

A microprocessor PID control system manages chamber temperature, while the shaker's brushless motor and triple-cam drive system are designed to provide smooth, high-torque operation under substantial loads. The combination makes the ISF-7100 particularly useful for extended culture experiments where stable temperature and continuous shaking are both important.

The touchscreen LCD provides access to operating parameters through an icon-based interface. A viewing window in the inclined lid and internal LED lighting allow researchers to observe samples while minimizing unnecessary chamber opening.

Key Specifications

Specification Details
Manufacturer Jeio Tech
Model ISF-7100
Series 7000 Series
Equipment Type Incubated orbital shaker
Temperature Range Ambient +5°C to 80°C
Temperature Control Microprocessor PID
Speed Range 30–500 rpm
Orbit 25.4 mm / 1 in.
Platform Dimensions 29.7"W × 20.5"D
Timer 1 min. to 999 hr. 59 min.
Interior Dimensions 35.2"W × 25"D × 18.9"H
Exterior Dimensions 44.3"W × 33.6"D × 40.8"H
Display / Controls Touchscreen LCD
Motor Brushless
Drive System Triple-cam
Electrical Requirements Verify specific unit with American Instrument Exchange
Condition Used / Refurbished
Warranty 90 days from American Instrument Exchange

Platform dimensions do not establish the number or size of vessels that can be accommodated. Practical capacity depends on the platform and accessories installed on the individual shaker, including clamps, racks, custom fixtures, vessel geometry, load distribution, and required clearance.

Common Applications

The Jeio Tech ISF-7100 is well suited for bacterial and yeast culture, recombinant protein expression, plasmid preparation, microbial growth studies, media optimization, extraction procedures, solubility studies, hybridization, strain development, and other laboratory processes requiring simultaneous temperature control and orbital agitation.

The ability to operate at temperatures substantially above ambient also makes the ISF-7100 useful for workflows requiring controlled warm incubation combined with continuous mixing.

Ideal Laboratory Types

The ISF-7100 is appropriate for biotechnology and pharmaceutical laboratories, microbiology facilities, molecular biology groups, protein-expression laboratories, fermentation and process-development groups, academic research laboratories, university core facilities, food and beverage research laboratories, and industrial research or quality-control environments.

Its large platform and floor-standing construction make it particularly suitable for laboratories requiring greater throughput than is practical with a small benchtop incubated shaker.

Temperature Control & Orbital Shaking Performance

The Jeio Tech ISF-7100 combines temperatures from ambient +5°C to 80°C with orbital shaking speeds from 30 to 500 rpm. Microprocessor PID control is used to regulate chamber temperature, providing the controlled environment needed for reproducible incubation and culture workflows.

A 25.4 mm, or 1-inch, orbit provides substantial liquid movement for microbial culture and general laboratory mixing. As with any orbital shaker, actual mixing and oxygen-transfer characteristics depend not only on rpm but also on orbit diameter, vessel geometry, working volume, platform arrangement, and the properties of the liquid being processed.

The brushless motor and triple-cam drive system are designed for smooth operation under demanding loads. Smooth acceleration and deceleration help reduce abrupt vessel movement and the potential for spills during startup and shutdown.

The system can also respond to conditions such as excessive loads, unbalanced placement, vibration, or external disturbance by adjusting shaking operation to promote stable performance.

Platform, Flask & Vessel Compatibility

The ISF-7100 has a large platform measuring approximately 29.7 inches wide by 20.5 inches deep, providing substantial space for laboratory culture and mixing applications.

Practical vessel capacity, however, depends on the exact platform configuration supplied with the individual unit. Flask clamps, racks, custom fixtures, vessel diameter, vessel height, working volume, and load distribution can all significantly change the number and size of vessels that can be operated safely.

For that reason, American Instrument Exchange does not recommend assuming that published manufacturer flask counts will apply to every used ISF-7100. Customers planning to use specific Erlenmeyer flasks, Fernbach flasks, bottles, tubes, or other vessels should confirm the platform and installed accessories with AIE before purchase.

This is particularly important with larger incubated shakers, where a custom platform or nonstandard clamp arrangement can substantially alter real-world capacity.

Refurbishment & Testing

Used Jeio Tech ISF-7100 incubated shakers from American Instrument Exchange are inspected and tested prior to shipment. The shaking mechanism is operated for extended periods to verify reliable performance and operation at applicable speed setpoints.

Because the ISF-7100 is an incubated shaker, AIE also uses an external digital temperature probe to verify that the displayed chamber temperature corresponds appropriately with independently measured conditions.

Testing includes evaluation of the orbital drive, speed controls, temperature controls, timer, display, safety functions, and other applicable mechanical and electrical components. The unit is cleaned and cosmetically prepared as appropriate before shipment.

Customers with specific testing requirements are encouraged to discuss them with American Instrument Exchange prior to shipment. While AIE cannot reproduce every analytical or biological application, testing can be tailored to simulate typical operating conditions when practical.

Shipping & Installation

The Jeio Tech ISF-7100 is a large floor-standing laboratory instrument measuring approximately 44.3 inches wide by 33.6 inches deep by 40.8 inches high. Laboratories should confirm doorway, hallway, elevator, and final installation clearances before delivery.

The shaker should be positioned on a stable, level surface with sufficient clearance for ventilation and full opening of the chamber lid. Because vessel movement and load balance affect shaker performance, platforms and samples should be configured appropriately before operation.

Electrical requirements should be confirmed for the specific AIE unit before installation. American Instrument Exchange can provide additional information about the individual shaker's configuration and shipping requirements before purchase.

Related Equipment

Laboratories using the Jeio Tech ISF-7100 may also require incubators, CO2 incubators, centrifuges, laboratory refrigerators, laboratory freezers, ultra-low freezers, water baths, and balances. American Instrument Exchange supplies used and refurbished laboratory equipment for biotechnology, pharmaceutical, academic, clinical, and industrial research laboratories.

Frequently Asked Questions

What type of shaker is the Jeio Tech ISF-7100?

The ISF-7100 is a floor-standing incubated orbital shaker. It combines controlled heating with orbital agitation in a single enclosed laboratory system.

What is the temperature range of the ISF-7100?

The ISF-7100 operates from approximately ambient +5°C to 80°C.

Does the ISF-7100 provide refrigeration?

No. This configuration is an incubated shaker designed for operation above ambient temperature. Applications requiring controlled temperatures below ambient require a refrigerated shaker.

What is the shaking speed range?

The ISF-7100 operates from 30 to 500 rpm.

What is the orbit diameter?

The ISF-7100 uses a 25.4 mm, or 1-inch, orbital motion.

How large is the shaking platform?

The platform measures approximately 29.7 inches wide by 20.5 inches deep.

How many flasks can the ISF-7100 hold?

Actual flask capacity depends on the installed platform, clamps or racks, flask dimensions, working volume, load distribution, and available chamber clearance. Because used units can have different platform configurations, customers should confirm the specific AIE unit rather than relying on a theoretical manufacturer flask count.

Can the ISF-7100 be used for microbial culture?

Yes. Its combination of controlled heating, orbital agitation, large platform area, and broad speed range makes the ISF-7100 well suited to many bacterial, yeast, protein-expression, and other microbial culture applications.

How does American Instrument Exchange test an incubated shaker?

AIE tests the shaking mechanism over extended operation and verifies applicable speed setpoints. For incubated models, an external digital temperature probe is also used to check the accuracy of the displayed chamber temperature.

Does this Jeio Tech ISF-7100 include a warranty?

Yes. This used and refurbished Jeio Tech ISF-7100 includes a 90-day warranty from American Instrument Exchange.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.