The Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator is a high-performance laboratory temperature control system designed for precise heating and cooling of laboratory baths and external circulation applications. With an ultra-wide operating temperature range of -90°C to +100°C, a powerful pressure/suction circulation pump, and exceptional temperature stability, the FP89-HL/TK is ideal for demanding applications in pharmaceutical research, materials science, analytical chemistry, cryogenic testing, and industrial process development. This refurbished Julabo FP89-HL/TK from American Instrument Exchange offers a cost-effective alternative to new equipment while delivering the precision, reliability, and long-term performance for which Julabo ultra-low refrigerated circulators are known. Based on the HighTech platform, the FP89-HL/TK is designed for both internal bath temperature control and closed-loop external circulation of laboratory equipment.
Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator Key Features
-
Julabo FP89-HL/TK ultra-low refrigerated heating circulator
-
Operating temperature range from -90°C to +100°C
-
High-performance cascade refrigeration system
-
Stainless steel insulated bath reservoir
-
Pressure/suction circulation pump for internal or external applications
-
Temperature stability of ±0.05°C
-
PID microprocessor temperature controller
-
Powerful refrigeration for rapid cool-down
-
Digital multi-function display
-
Adjustable pump pressure and flow
-
RS-232 communication interface
-
Low-liquid level and over-temperature safety protection
-
Refurbished and tested by American Instrument Exchange
-
90-day warranty included from American Instrument Exchange
Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator Overview
The Julabo FP89-HL/TK is engineered for laboratories requiring highly accurate temperature control across an exceptionally wide operating range. Its cascade refrigeration system allows temperatures approaching -90°C while maintaining excellent stability for both bath and external circulation applications. The powerful pressure/suction pump delivers reliable circulation to jacketed reactors, calorimeters, condensers, viscometers, adsorption analyzers, and other laboratory equipment requiring precise thermal regulation. Julabo's PID temperature control continuously adjusts heating and refrigeration output to minimize temperature fluctuations during changing process loads, making the FP89-HL/TK well suited for both research and production environments.
Common Applications for the Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator
The FP89-HL/TK is commonly used for cryogenic materials testing, adsorption analysis, pharmaceutical process development, chemical synthesis, reactor temperature control, polymer research, aerospace materials testing, environmental simulation, semiconductor research, calibration laboratories, and analytical chemistry. Its ultra-low temperature capability makes it particularly valuable for applications requiring stable sub-zero temperature control that cannot be achieved with conventional refrigerated circulators.
Ideal Lab Types for the Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator
This ultra-low refrigerated circulator is well suited for pharmaceutical manufacturers, biotechnology companies, university research laboratories, analytical chemistry laboratories, materials science laboratories, petrochemical laboratories, cryogenic testing facilities, government research institutions, and industrial R&D departments. Laboratories utilizing jacketed glass reactors, adsorption analyzers, calorimeters, rheometers, viscometers, and environmental testing equipment frequently incorporate ultra-low refrigerated circulators into advanced temperature-controlled workflows.
Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator Key Specifications
| Specification |
Details |
| Manufacturer |
Julabo |
| Model |
FP89-HL/TK |
| Equipment Type |
Ultra-Low Refrigerated Heating Circulator |
| Temperature Range |
-90°C to +100°C |
| Temperature Stability |
±0.05°C |
| Bath Capacity |
5.5-8.0 Liters |
| Heating Capacity |
1.3 kW |
| Cooling System |
Cascade Refrigeration |
| Pump Type |
Pressure/Suction Circulation Pump |
| Pump Flow Rate |
Up to 22 L/min |
| Maximum Pump Pressure |
0.9 bar |
| Controller |
PID Microprocessor |
| Display |
Digital Multi-Display |
| Communications |
RS-232 |
| Bath Opening |
130 × 150 mm (5.1" × 5.9") |
| Overall Dimensions |
Approximately 21.7" W × 24.0" D × 36.2" H |
| Weight |
Approximately 267 lbs (121 kg) |
| Electrical Requirements |
230V, 60 Hz |
| Condition |
Refurbished |
Specifications compiled from Julabo manufacturer literature, distributor technical references, and American Instrument Exchange product information.
Refurbishment and Testing Process
At American Instrument Exchange, each refurbished refrigerated circulator is inspected and evaluated by our technicians prior to shipment. Testing procedures may include verification of refrigeration performance, heater operation, circulation pump performance, temperature stability, controller functionality, display operation, alarm systems, electrical safety testing, and overall operational evaluation. Whenever practical, the unit is operated through both heating and cooling cycles to verify proper performance throughout its operating range. Components showing excessive wear are serviced or replaced as needed to help ensure dependable laboratory performance. Final cleaning and inspection are completed before packaging and shipment.
Shipping and Installation Considerations
The Julabo FP89-HL/TK should be installed on a stable laboratory floor with adequate ventilation around the refrigeration system. Buyers should verify electrical compatibility before installation and use only Julabo-approved low-temperature heat transfer fluids suitable for ultra-low temperature operation. When used for external circulation, insulated tubing is recommended to maximize temperature stability and reduce heat loss. Because of the unit's size and weight, shipment is made via freight, and appropriate material-handling equipment should be available during installation.
Related Laboratory Equipment
Laboratories purchasing ultra-low refrigerated circulators often also require jacketed glass reactors, rotary evaporators, laboratory chillers, analytical balances, water baths, freeze dryers, centrifuges, and laboratory freezers. American Instrument Exchange offers a wide selection of refurbished laboratory equipment to support pharmaceutical development, analytical chemistry, biotechnology research, cryogenic testing, and industrial laboratory applications.
Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator Frequently Asked Questions
Can the Julabo FP89-HL/TK control the temperature of external laboratory equipment?
Yes. The FP89-HL/TK includes a powerful pressure/suction circulation pump designed for closed-loop temperature control of jacketed reactors, calorimeters, adsorption analyzers, condensers, and other external laboratory systems.
What is the lowest operating temperature?
The FP89-HL/TK is capable of maintaining temperatures as low as -90°C, making it suitable for demanding cryogenic laboratory applications.
Can the circulator both heat and cool?
Yes. The integrated refrigeration system and electric heater allow the FP89-HL/TK to provide continuous temperature control from -90°C to +100°C without changing equipment.
What types of laboratories commonly use the FP89-HL/TK?
The FP89-HL/TK is widely used in pharmaceutical research, materials science, cryogenic testing, adsorption analysis, analytical chemistry, semiconductor research, and advanced industrial process development where precise ultra-low temperature control is required.
What warranty is included?
This refurbished Julabo FP89-HL/TK Ultra-Low Refrigerated Heating Circulator includes a 90-day warranty from American Instrument Exchange.