JULABO FT900 Immersion Cooler

Fully Tested & Warrantied*
Brand : Julabo
Product Code : SKU 1467Z CIRC
Title: $5100.00

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

JULABO FT900 Immersion Cooler

The JULABO FT900 Immersion Cooler is an ultra-low-temperature laboratory cooling system designed for rapid cooling of liquids and counter-cooling of heated circulating baths. Rather than pumping coolant through external equipment like a conventional recirculating chiller, the FT900 uses a long, flexible stainless-steel immersion probe that is placed directly into a compatible bath or vessel.

With a working temperature range extending from approximately -90°C to +30°C, the JULABO FT900 provides a convenient mechanical-refrigeration alternative to dry ice, liquid cooling water, and other expendable cooling methods. The two-stage refrigeration system maintains useful cooling capacity even at extremely low temperatures, making the FT900 particularly useful for chemistry, materials research, low-temperature experiments, and laboratory processes requiring rapid subambient cooling.

Available used and refurbished from American Instrument Exchange, this JULABO FT900 is inspected and tested for dependable laboratory operation. A 90-day warranty is included.

Key Features

  • -90°C to +30°C working temperature range

  • Flexible stainless-steel immersion cooling probe

  • 25.6 in. / 65 cm probe length

  • 0.6 in. / 1.5 cm probe diameter

  • Two-stage air-cooled refrigeration system

  • 300 W cooling capacity at +20°C

  • 240 W cooling capacity at -20°C

  • 200 W cooling capacity at -40°C

  • 70 W cooling capacity at -80°C

  • Designed for rapid direct cooling of liquids

  • Excellent for counter-cooling heated circulators

  • Mechanical alternative to dry ice cooling

  • Can reduce dependence on continuous tap-water cooling

  • No circulation pump or external fluid loop required

  • Compact, mobile design

  • Used, refurbished, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The JULABO FT900 differs substantially from a conventional refrigerated circulator or recirculating chiller.

Instead of cooling an internal reservoir and pumping heat-transfer fluid through an external circuit, the FT900 uses a flexible stainless-steel cooling probe connected directly to its refrigeration system. The probe is immersed in the liquid that needs to be cooled, providing direct heat removal without requiring a separate coolant circulation loop.

This design makes the FT900 particularly useful for adding refrigeration to an existing laboratory bath. A heated circulating bath can provide fluid agitation and precise temperature regulation while the FT900 supplies the refrigeration necessary to reach temperatures below ambient.

The FT900 can also be used for rapid cooling of compatible liquids in other laboratory vessels. Its two-stage refrigeration system allows operation to approximately -90°C, providing substantially greater low-temperature capability than most conventional refrigerated circulating baths.

The basic FT900 is a cooling device rather than a standalone precision temperature controller. Applications requiring tightly regulated bath temperature should pair the FT900 with appropriate temperature-control equipment or consider a temperature-controlled immersion cooler.

Key Specifications

Specification Details
Manufacturer JULABO
Model FT900
Equipment Type Immersion cooler / cold-finger cooler
Order Number 9650890
Working Temperature Range -90°C to +30°C
Cooling Capacity at +20°C 300 W
Cooling Capacity at +10°C 270 W
Cooling Capacity at 0°C 270 W
Cooling Capacity at -20°C 240 W
Cooling Capacity at -40°C 200 W
Cooling Capacity at -80°C 70 W
Refrigeration Two-stage, air-cooled
Refrigerants R404A and R23
Immersion Probe Flexible stainless steel
Probe Dimensions 25.6 in. L × 0.6 in. diameter / 65 × 1.5 cm
Ambient Operating Range +5°C to +35°C
Exterior Dimensions Approx. 15 in. W × 21.7 in. D × 23.6 in. H
Weight Approx. 110 lb / 50 kg
Available Electrical Configurations 115 V, 60 Hz or 230 V, 50/60 Hz
Warranty 90 days

Common Applications

The JULABO FT900 is designed for laboratory procedures requiring direct and rapid removal of heat from a liquid. Common applications include counter-cooling heated circulating baths, low-temperature chemistry, reaction cooling, cold-bath preparation, materials research, sample preparation, viscosity studies, condensation procedures, and general low-temperature laboratory experimentation.

The FT900 is particularly useful when a laboratory already has a heated circulator that provides good temperature control but lacks refrigeration. Placing the FT900 probe into the bath adds substantial cooling capability without replacing the existing circulator.

It can also serve as an alternative to dry ice for compatible procedures. Because the FT900 uses mechanical refrigeration, laboratories can repeatedly perform low-temperature cooling without purchasing, transporting, handling, and replenishing dry ice for every experiment.

For applications traditionally cooled with continuously flowing tap water, an immersion cooler can also reduce water consumption.

Ideal Laboratory Types

The JULABO FT900 is well suited for chemistry laboratories, pharmaceutical research facilities, biotechnology laboratories, materials-science groups, process-development laboratories, industrial R&D facilities, academic research laboratories, and other environments performing low-temperature experiments.

Organic and synthetic chemistry laboratories may find the FT900 particularly useful for reaction cooling and low-temperature bath preparation.

The system can also be valuable in shared research facilities because the flexible probe allows the same refrigeration unit to be used with different compatible baths and experimental vessels rather than dedicating the refrigeration system to one permanent circulation loop.

Temperature Control & Cooling Performance

The JULABO FT900 has a working temperature range of approximately -90°C to +30°C.

Cooling capacity varies considerably with operating temperature. The system provides approximately 300 W at +20°C, 270 W at +10°C and 0°C, 240 W at -20°C, 200 W at -40°C, and 70 W at -80°C.

This cooling curve is important when evaluating the FT900 for an application. Although the unit can reach extremely low temperatures, its ability to remove a continuous external heat load decreases as the bath approaches the lower end of its operating range.

For example, an application requiring 150 W of continuous heat removal at -80°C would exceed the FT900's approximately 70 W cooling capacity at that temperature even though -80°C is within the unit's nominal working range.

The FT900 itself should also not be confused with a temperature-regulated bath circulator. The basic FT900 supplies refrigeration through its immersion probe but does not independently maintain the surrounding bath at a programmed temperature setpoint. Precise temperature regulation requires appropriate complementary temperature-control equipment.

Immersion Probe & Cooling Performance

Instead of a conventional circulation pump, the JULABO FT900 transfers cooling directly through a flexible stainless-steel immersion probe.

The probe measures approximately 25.6 inches, or 65 cm, long and approximately 0.6 inch, or 1.5 cm, in diameter. Its flexible design allows the probe to be positioned within compatible laboratory baths and vessels.

Direct immersion eliminates the need to connect coolant supply and return hoses between the FT900 and the process. This simplifies setup and can make it easier to use one cooling system with multiple laboratory baths.

Adequate fluid circulation or agitation within the receiving bath is still important. Movement of the bath fluid improves heat transfer away from the immersion probe and promotes more uniform temperature throughout the vessel.

Care should also be taken to select a bath fluid appropriate for the intended temperature. Extremely low-temperature applications require fluids that remain sufficiently fluid and thermally effective at the target operating temperature.

Refurbishment & Testing

This used JULABO FT900 Immersion Cooler is refurbished and tested by American Instrument Exchange before shipment. Our technicians inspect the two-stage refrigeration system, compressors, condenser, flexible immersion probe, refrigerant circuit, electrical components, controls, housing, and associated safety systems.

Temperature-controlled equipment is tested using NIST-traceable probes and data loggers. The FT900 is operated under simulated laboratory conditions to evaluate temperature pull-down, refrigeration performance, probe cooling, and overall system operation.

The flexible probe is inspected for physical condition and the refrigeration system is evaluated for reliable operation before shipment.

Customers requiring the FT900 for a specific low-temperature procedure are encouraged to provide the target temperature, bath fluid, approximate bath volume, and expected heat load. When practical, American Instrument Exchange can incorporate customer-requested operating conditions into final testing.

A 90-day warranty is included with this refurbished JULABO immersion cooler.

Choosing the Right Immersion Cooler or Circulator

The JULABO FT900 is particularly appropriate when very low temperatures are required but a conventional refrigerated bath or recirculating chiller is unnecessary or impractical.

Its -90°C lower operating range provides substantially greater low-temperature capability than many standard refrigerated bath circulators. The flexible probe also makes it easy to add refrigeration to an existing compatible bath.

The FT900 is especially attractive for laboratories currently using dry ice or continuous cooling water. Mechanical refrigeration can provide a more convenient and repeatable source of cooling while reducing dependence on consumable cooling materials.

However, the FT900 is not a direct replacement for every refrigerated circulator. It does not provide its own process-fluid circulation pump or standalone precision bath-temperature regulation.

Applications requiring a self-contained reservoir, active circulation, programmable temperature control, or external closed-loop fluid connections may be better served by a conventional refrigerated/heated circulator or recirculating chiller.

American Instrument Exchange can help compare available immersion coolers and laboratory circulators based on minimum temperature, cooling capacity, bath size, temperature-control requirements, and intended application.

Related Equipment

American Instrument Exchange stocks a range of laboratory circulators, including JULABO immersion coolers, refrigerated/heated bath circulators, recirculating chillers, and process temperature-control systems. Laboratories using the FT900 may also want to compare available laboratory water baths, reactors and fermenters, evaporators and extractors, and other refurbished laboratory equipment.

JULABO FT900 Frequently Asked Questions

What is the temperature range of the JULABO FT900?

The FT900 has a working temperature range of approximately -90°C to +30°C.

How much cooling capacity does the FT900 provide?

Cooling capacity depends on temperature. The FT900 provides approximately 300 W at +20°C, 240 W at -20°C, 200 W at -40°C, and 70 W at -80°C.

Is the JULABO FT900 a recirculating chiller?

No. The FT900 is an immersion cooler. Instead of pumping coolant through an external loop, it uses a flexible stainless-steel probe that is placed directly into the liquid being cooled.

Can the FT900 be used with a heated circulating bath?

Yes. Counter-cooling heated circulators is one of the FT900's primary applications. The circulator can provide bath agitation, heating, and temperature control while the FT900 provides refrigeration.

Can the FT900 replace dry ice?

For many compatible laboratory cooling procedures, it can provide a reusable mechanical-refrigeration alternative to dry ice. Whether it is appropriate depends on the required temperature, bath volume, fluid, and heat load.

Does the FT900 regulate temperature automatically?

The basic FT900 provides refrigeration but does not independently regulate the receiving bath to a programmed temperature setpoint. Temperature-controlled applications require appropriate complementary controls. JULABO also produced related immersion-cooler models with integrated temperature-control capability.

What type of cooling probe does the FT900 use?

The FT900 uses a flexible stainless-steel immersion probe approximately 25.6 inches long and 0.6 inch in diameter.

What refrigerants are used in the FT900?

The two-stage refrigeration system uses R404A and R23 refrigerants.

Is the FT900 suitable for -80°C applications?

Yes, provided the application's heat load is appropriate. The FT900 still supplies approximately 70 W of cooling capacity at -80°C, so heat load and bath conditions should be evaluated before use.

Does this refurbished JULABO FT900 include a warranty?

Yes. This used JULABO FT900 is refurbished and tested by American Instrument Exchange and includes a 90-day warranty.

Want to view a video of this unit? Click Here to see the Julabo FT900 on the American Instrument Exchange YouTube channel.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.