Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Labconco Purifier 3980301 Class 1 Safety Enclosure

Fully Tested & Warrantied*
Brand : Labconco
Product Code : SKU 2864U HOOD
Size: $1850.00
Color: 08-18-2023

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Labconco Purifier 3980301 Class I Safety Enclosure

The Labconco Purifier 3980301 Class I Safety Enclosure is a compact personnel-protection enclosure designed for laboratory procedures involving biological agents, aerosols, powders, and other materials where operator containment is required but product protection is not. Available used and refurbished from American Instrument Exchange, this 3-foot enclosure provides an economical alternative to a Class II biosafety cabinet for applications that do not require HEPA-filtered supply air or protection of the material being handled.

Unlike a conventional chemical fume hood, the Purifier 3980301 uses controlled inward airflow and HEPA-filtered exhaust to help contain airborne particulates and aerosols generated inside the work area. The enclosure is designed for a nominal inflow velocity of 75 to 105 fpm and incorporates multiple airflow-management features to promote effective containment while maintaining a compact benchtop footprint.

Measuring approximately 35.75" W × 28.64" D × 37.05" H, the Purifier 3980301 is particularly useful for laboratories that need localized personnel protection without dedicating the space required for a full-size biosafety cabinet.

Key Features

  • Used and refurbished Labconco Purifier Class I Safety Enclosure

  • Catalog/model number 3980301

  • Compact 3-foot benchtop configuration

  • Provides personnel protection without product protection

  • Designed for applications involving agents requiring Biosafety Level 1, 2, or 3 containment when Class I protection is appropriate

  • Nominal inflow velocity of 75 to 105 fpm

  • Designed for HEPA-filtered exhaust

  • Built-in variable-speed blower system

  • Ergonomic air foil with Clean-Sweep airflow openings

  • Zone-perforated rear baffle and side-entry air foils

  • Hinged tempered safety-glass sash

  • 9.44" nominal working sash opening

  • 115V, 60 Hz electrical requirements

  • 90-day warranty included from American Instrument Exchange

Class I Personnel Protection

The most important distinction when selecting the Labconco Purifier 3980301 is understanding what a Class I enclosure is designed to protect. Air is drawn inward through the front opening, helping prevent aerosols and airborne contaminants generated within the enclosure from escaping toward the operator.

Contaminated air is then drawn through the enclosure's exhaust filtration system before discharge. This airflow arrangement provides personnel and environmental protection for appropriate applications but does not provide product protection because unfiltered room air enters directly through the front opening.

For laboratories that need to protect personnel from an aerosol-generating process but do not need to maintain a sterile work area around the sample, a Class I enclosure can provide a practical alternative to a more complex Class II biosafety cabinet.

Common Applications

The Purifier 3980301 can be used for laboratory procedures capable of generating aerosols, particulates, or other airborne contaminants when Class I containment is appropriate. Applications may include microbiological procedures, sample preparation, tissue processing, small-scale biological research, powder handling, equipment manipulation, and other procedures where personnel protection is more important than protecting the sample from room air.

Its relatively small footprint also makes the enclosure useful for laboratories that need to isolate a specific procedure without installing a larger biosafety cabinet.

Application suitability should always be determined through an appropriate laboratory risk assessment based on the materials and procedures being performed.

Compact Benchtop Containment

At approximately 35.75 inches wide, the Labconco 3980301 provides localized containment without consuming the floor space required by a conventional freestanding biosafety cabinet or full-size laboratory hood. This makes it especially useful in crowded research laboratories, specialty testing areas, and facilities adding containment to an existing laboratory layout.

The enclosure measures approximately 28.64 inches deep and 37.05 inches high, allowing it to be positioned on an appropriate laboratory work surface or supporting base.

Its compact dimensions can also make the 3980301 attractive when a laboratory needs several dedicated containment stations for different procedures rather than one large centralized enclosure.

Airflow and Containment Design

Labconco designed the Purifier enclosure around controlled inward airflow. An ergonomic front air foil incorporates Clean-Sweep airflow openings, while side-entry air foils, an upper dilution air supply, an upper containment sash foil, and a zone-perforated rear baffle help direct air through the work area.

The enclosure is designed to operate at a nominal inflow velocity between 75 and 105 fpm. A built-in variable-speed blower allows airflow to be adjusted as required for the enclosure and installed filtration configuration.

These airflow features are particularly important during procedures that may generate aerosols or particulates, where maintaining effective inward airflow at the front opening helps reduce operator exposure.

Hinged Sash and Work Area Access

The Purifier 3980301 incorporates a tempered safety-glass front sash with a nominal 9.44-inch working opening. The angled sash provides visibility into the enclosure while maintaining the controlled opening required for normal operation.

For loading equipment or accessing the interior for cleaning, the sash can be hinged upward to provide a substantially larger opening. This makes it easier to position instruments, containers, and other laboratory equipment within the work area without compromising the smaller opening used during normal operation.

Ideal Laboratory Environments

The Labconco Purifier 3980301 is well suited for microbiology laboratories, biotechnology research facilities, pharmaceutical laboratories, university research laboratories, hospital and clinical research facilities, environmental laboratories, industrial laboratories, and other facilities that require compact personnel containment.

It can be particularly valuable where the process requires protection of the operator and surrounding environment but does not require protection of the sample from ambient laboratory air.

Key Specifications

Specification Details
Manufacturer Labconco
Product Line Purifier
Model / Catalog Number 3980301
Enclosure Type Class I Safety Enclosure
Nominal Width 3 feet
Exterior Dimensions 35.75" W × 28.64" D × 37.05" H
Personnel Protection Yes
Product Protection No
Nominal Inflow Velocity 75–105 fpm
Exhaust Volume Approximately 165–230 CFM
Nominal Sash Opening 9.44"
Sash Hinged tempered safety glass
Blower Built-in variable-speed blower
Electrical 115V, 60 Hz
Weight Approximately 160 lb
Filter HEPA exhaust filtration configuration; verify included filter with AIE
Condition Used and refurbished
Warranty 90 days

Refurbishment and Testing

This Labconco Purifier 3980301 is inspected and refurbished by American Instrument Exchange prior to shipment. Technicians inspect the enclosure, sash, blower system, lighting, airflow components, and other operating features as applicable to the individual unit.

Because proper containment depends on airflow performance and the condition and installation of the exhaust filtration system, laboratories should verify the required filtration and certification procedures for their application before placing the enclosure into service.

Please confirm the filter configuration included with the specific unit before purchase.

Choosing a Class I Enclosure vs. a Class II Biosafety Cabinet

A Class I safety enclosure and a Class II biosafety cabinet serve different purposes. The Labconco Purifier 3980301 is designed primarily to protect personnel and the surrounding environment. Because room air enters the enclosure through the front opening, the sample itself is not protected from contaminants present in the laboratory.

A Class II biosafety cabinet adds HEPA-filtered supply air to provide product protection in addition to personnel and environmental protection. Laboratories performing sterile cell culture, aseptic manipulations, or other procedures where sample protection is essential should generally consider an appropriate Class II biosafety cabinet instead.

For procedures where personnel containment is required but product sterility is not, the Class I design can provide a simpler and more compact solution.

Why Buy a Refurbished Laboratory Safety Enclosure from American Instrument Exchange?

Purchasing a refurbished Class I enclosure can allow laboratories to add dedicated containment capacity without the cost of purchasing a new biosafety cabinet when the application does not require Class II protection.

American Instrument Exchange refurbishes and tests used laboratory equipment before shipment and can help customers compare Class I enclosures, biosafety cabinets, chemical fume hoods, and other containment equipment based on the intended application.

The Labconco Purifier 3980301 is backed by a 90-day warranty from American Instrument Exchange.

Frequently Asked Questions

Is the Labconco 3980301 a chemical fume hood?

No. Although its enclosure design resembles a small laboratory hood, the Purifier 3980301 is a Class I safety enclosure designed around particulate and biological containment. It should not automatically be substituted for a chemical fume hood intended to handle hazardous chemical vapors.

Does the Labconco Purifier 3980301 protect the sample?

No. The Class I airflow design provides personnel and environmental protection but does not provide product protection. Room air enters through the front opening and passes through the work area.

What is the difference between this enclosure and a Class II biosafety cabinet?

A Class II biosafety cabinet provides personnel, environmental, and product protection through a combination of inward airflow and HEPA-filtered supply air. The Class I Purifier is intended for applications where personnel containment is required but product protection is unnecessary.

Does the Labconco 3980301 have a built-in blower?

Yes. The 3980301 configuration incorporates a variable-speed blower as part of its airflow system.

Does this enclosure include a HEPA filter?

The Purifier Class I enclosure is designed for HEPA-filtered exhaust; however, the currently listed American Instrument Exchange unit specifies that filters are not included. Buyers should confirm the filtration supplied with the individual unit before purchase.

What applications are appropriate for a Class I safety enclosure?

Class I enclosures can be appropriate for aerosol-generating biological procedures, particulate handling, sample preparation, and other processes where personnel protection is required but product protection is not. The laboratory should perform a risk assessment to determine whether Class I containment is appropriate for the specific procedure.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.