Labconco Purifier Logic 4’ Class II, Type B2
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
Shipping
All products ship from our 30,000 sq. ft. Haverhill, MA warehouse
The Labconco Purifier Logic 4’ Class II Type B2 biosafety cabinet is designed to provide personnel, product, and environmental protection for laboratory procedures requiring total exhaust containment and contamination-controlled airflow. Commonly used for microbiology, cell culture, pharmaceutical preparation, antineoplastic drug preparation, and biological research workflows, this refurbished Labconco Type B2 biosafety cabinet is appropriate for laboratories requiring a fully exhausted cabinet configuration.
At American Instrument Exchange, each biosafety cabinet is inspected and tested by our technicians prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.
The Labconco Purifier Logic 4’ Class II Type B2 biosafety cabinet is a total exhaust biological safety cabinet designed for laboratory environments requiring contamination control, sterile airflow, operator protection, and full exhaust of cabinet air through a properly connected facility exhaust system. Unlike Class II Type A2 biosafety cabinets, which recirculate a portion of filtered air back into the laboratory, Type B2 cabinets exhaust 100% of cabinet air to the outside through a dedicated exhaust connection.
This cabinet configuration is commonly used for laboratory procedures involving hazardous particulates, biological materials, antineoplastic drug preparation, and applications where a total exhaust airflow design is required by laboratory protocols or facility safety standards.
Labconco Purifier Logic cabinets are widely used in biotechnology, pharmaceutical, clinical, hospital, academic, and government research laboratories because of their ergonomic design, airflow control systems, and laboratory-focused containment performance. Features may include stainless steel interior surfaces, angled sash design, airflow monitoring, bright interior lighting, and ergonomic workspace configuration depending on the specific unit.
Because this is a Type B2 biosafety cabinet, buyers should confirm exhaust compatibility, facility ductwork requirements, and certification requirements before installation.
The Labconco Purifier Logic 4’ Type B2 biosafety cabinet is commonly used for laboratory procedures requiring sterile airflow, biological containment, and total exhaust operation. Typical applications include microbiology workflows, cell culture procedures, tissue culture applications, biological sample handling, pharmaceutical preparation, antineoplastic drug preparation, and work with agents requiring Biosafety Level 1, 2, or 3 containment when used in an appropriate laboratory setting.
This cabinet may also be appropriate for laboratories working with materials or procedures where recirculation is not desired and total exhaust through a dedicated building exhaust system is required.
This biosafety cabinet may be suitable for pharmaceutical laboratories, hospital pharmacies, oncology preparation areas, biotechnology laboratories, academic research institutions, clinical laboratories, government research facilities, and cleanroom or containment-focused laboratory environments.
Its Type B2 total exhaust configuration makes it especially relevant for facilities that require a fully exhausted biosafety cabinet for certain pharmaceutical, biological, or contamination-sensitive workflows.
|
Specification |
Details |
|
Manufacturer |
Labconco |
|
Model |
Purifier Logic 0883FFF / Catalog No. 3461001 |
|
Cabinet Class |
Class II Type B2 |
|
Nominal Width |
4 ft |
|
Exhaust Configuration |
100% exhausted air / total exhaust |
|
Sash Opening |
8 in |
|
Exterior Dimensions |
54.31” W × 31.21” D × 61.4” H |
|
Interior Worksurface Dimensions |
48.5” W × 17.59” D × 29.2” H |
|
Electrical Requirements |
115V, 60 Hz |
|
Included Accessories |
New HEPA filters |
|
Warranty |
90-day warranty |
|
Condition |
Refurbished |
American Instrument Exchange has extensive experience refurbishing used biosafety cabinets for laboratory and cleanroom environments.
Each biosafety cabinet is inspected by our technicians to verify proper blower operation, control functionality, airflow performance, lighting operation, cabinet integrity, and overall system condition prior to shipment. Unless otherwise specified, new HEPA filters are installed at our facility before delivery.
Testing procedures include major elements associated with biosafety cabinet certification to help support certification readiness upon installation at your facility. Because this is a Type B2 total exhaust cabinet, final installation should include confirmation of exhaust connection, airflow performance, and certification by qualified field technicians.
Certification Readiness
Biosafety cabinets should be certified by qualified field technicians after installation and before laboratory use. This is especially important for Class II Type B2 biosafety cabinets because they must be connected to an appropriate exhaust system and verified for proper inflow, downflow, and exhaust performance.
American Instrument Exchange performs functional testing prior to shipment to support certification readiness upon arrival. Buyers should confirm facility compatibility, electrical requirements, exhaust requirements, airflow specifications, and certification standards prior to installation.
Certification services are available through our affiliate company, https://www.aielaboratoryservices.com, which provides biosafety cabinet certification, testing, and field service support.
Certification requirements may vary depending on laboratory protocols, facility standards, cabinet installation, and application requirements.
Shipping and Installation Considerations
Biosafety cabinets are oversized laboratory instruments that may require special handling during transportation, delivery, and installation. Buyers should confirm laboratory access dimensions, doorway clearances, electrical compatibility, exhaust ducting requirements, and final cabinet placement before shipment.
Because this Labconco Purifier Logic is a Class II Type B2 total exhaust cabinet, installation should be coordinated with facility engineering, safety personnel, or a qualified biosafety cabinet service provider to verify ductwork compatibility and certification requirements.
Depending on the installation environment, liftgate delivery, inside delivery services, rigging assistance, or coordinated facility access may be recommended.
This unit is a Class II Type B2 biosafety cabinet. Type B2 cabinets are total exhaust cabinets designed to exhaust 100% of cabinet air through an appropriate facility exhaust system.
Total exhaust means that the cabinet exhausts all air from the cabinet rather than recirculating a portion of filtered air back into the laboratory. This configuration requires connection to a properly designed exhaust system.
This is a 4-foot biosafety cabinet with exterior dimensions of approximately 54.31” W × 31.21” D × 61.4” H and interior dimensions of approximately 48.5” W × 17.59” D × 29.2” H.
Typical applications include microbiology workflows, cell culture procedures, biological sample handling, pharmaceutical preparation, antineoplastic drug preparation, and work requiring BSL-1, BSL-2, or BSL-3 containment in an appropriate laboratory setting.
Yes. Unless otherwise specified, new HEPA filters are installed by American Instrument Exchange technicians prior to shipment.
Yes. As a Class II Type B2 total exhaust biosafety cabinet, this unit must be connected to an appropriate facility exhaust system and certified after installation.
Yes. A 90-day warranty from American Instrument Exchange is included.
The cabinet is tested prior to shipment to support certification readiness upon installation. Final certification should be completed by qualified field technicians after installation and exhaust connection.
Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.
Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Yes – please see our repair services page for more information.